Run-in with chemical additive protects gear surface

Run-in treatment provides a protective coating on turbopump gear surfaces so that they are capable of operation under marginal conditions in mineral oil and diester lubricants. This treatment protects highly loaded gears during relatively short-term operation.

Hartman, M. A.↗

Changes Found on Run-In and Scuffed Surfaces of Steel Chrome Plate, and Cast Iron

A study was made of run-in and scuffed steel, chrome-plate, and cast-iron surfaces. X-ray and electron diffraction techniques, micro-hardness determinations, and microscopy were used. Surface changes varied and were found to include three classes: chemical reaction, hardening, and crystallite-size alteration. The principal chemical reactions were oxidation and carburization.

IRON, CAST - WEAR RESISTANCE↗

Cyclic Run-In of Interlocking Metasurfaces

Interlocking metasurfaces were mechanically latched and unlatched for 500 cycles in order to see how they break-in with use. Different surface manufacture conditions were used in this work. Various characterization criteria were used to identify differences.

Garber, Kevin Wayne [Sandia National Laboratories ↗

Correlation of asperity contact-time fraction with elastohydrodynamic film thickness in a 20-millimeter-bore ball bearing

Elastohydrodynamic film thicknesses and asperity contact-time fractions were measured for a 20 mm bore ball bearing by using the capacitance and conductance techniques. The bearing was thrust loaded to 90, 445, and 778 N. The corresponding maximum stresses on the inner race were 1.28, 2.09, and 2.45 GPa. The test speed ranged from 400 to 15,000 rpm. The test bearing was mist lubricated with a MIL-L-23699A turbine oil. The temperature was 27 C. The experimental results were correlated to give the percent film (no-contact-time fraction) as a function of measured film thickness. Measurements were made for three test series that represented the test bearing in various conditions of run-in. The measurements show that the percent film changes with bearing run-in time. The experimental results agreed well with theoretical predictions based on surface trace analysis for a new bearing. For the run-in state, they agreed with previously reported experimental results. The results show that asperity contact existed at a film thickness-roughness ratio lambda of 6.0 or less for a new bearing. After run-in, no asperity contact occurred at a lambda of 3.5 or greater.

Coy, J. J.↗

Parameter Study of the Running-In Process for the Generic Pebble Bed Reactor (GPBR200)

The run-in period of a pebble bed reactor is complex and difficult to model given significant heterogeneity in core composition, power, and temperature. While it is understood that the initial composition of the core should eventually result in the same equilibrium core composition, the approach to equilibrium can vary significantly depending on factors such as start-up fuel enrichment and power ramp rate. To explore this, a high-fidelity model of the General Pebble Bed Reactor was used to vary power ramp schemes and start-up core compositions. It was found that both the initial core composition and power ramp rate had a significant impact on the flow rate of pebbles during early time steps, with higher ramp rates and low enrichment resulting in non-physical flow rates. Power ramp rate alone was found to dictated maximum pebble power peaking observed during the run-in process, with higher ramp rates resulting in greater peak pebble powers. Start-up fuel enrichment and power ramp were found to both impact total fuel consumption, although the impact of start-up fuel enrichment was generally secondary to ramp rate.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

The synergistic effects of slip ring-brush design and materials

The design, fabrication, and testing of four power slip rings for synchronous orbit application are considered. Environmental and instrumentation systems necessary for monitoring electrical noise, friction, and brush wear in air and at less than 5 X 10 to the minus 8th power torr were developed. Composite brushes consisting of silver-molybdenum disulfide-graphite and silver-niobium diselenide-graphite were employed on rings of coin silver and rhodium plate. These four contact combinations were tested during ambient condition run-in at 150 and a humidity sequence at 0.1. The first nine months of a two year vacuum test performed at 0.1 rpm were completed.

Lewis, N. E.↗

Friction, wear and noise of slip ring and brush contacts for synchronous satellite use.

A program is being conducted for testing of slip rings for synchronous orbit application. Instrumentation systems necessary for monitoring electrical noise, friction, and brush wear at atmospheric pressure and at less than 50 ntorr have been developed. A multiplex scheme necessary for the simultaneous recording of brush displacement, friction, and electrical noise has also been developed. Composite brushes consisting of silver-molybdenum disulfide-graphite and silver-niobium diselenide-graphite have been employed on rings of coin silver and rhodium plate. Four contact combinations have been tested during an ambient condition run-in at 150 rpm and a humidity sequence at 0.1 rpm. The first six months of the two year vacuum test at 0.1 rpm have been completed. Electrical noise, friction and brush wear data recorded during these periods have been analyzed.

Lewis, N. E.↗

Asperity interactions in EHD contacts

Infrared temperature measurements, ferrographic analysis, and surface profilimetry were used to monitor asperity interactions in a sliding EHD point contact. The contact temperature and surface profile signals obtained both before and after a run-in period are compared in the frequency domain by means of a Fourier analyzer. The interaction of surface asperities is accompanied by the presence of a high frequency component in the infrared signal. It is also shown that only a relatively narrow band of wavelengths of the surface profile spectrum are relevant in the interaction process.

Nagaraj, H. S.↗

Lubrication and failure mechanisms of molybdenum disulfide films. 2: Effect of substrate roughness

An optical microscope was used to study the lubrication and failure mechanisms of rubbed MoS2 films applied to three substrate surface finishes; polished, sanded, and sandblasted as a function of sliding distance. The lubrication mechanism was the plastic flow of thin films of MoS2 between flat plateaus on the rider and on the metallic substrate. If the substrate was rough, flat plateaus were created during run-in and the MoS2 flowed across them. Wear life was extended by increasing surface roughness since valleys in the roughened substrate served as reservoirs for MoS2 and as deposit sites for wear debris. In moist air the failure mechanism was the transformation of metallic colored MoS2 films to a black, powdery material that was found by X-ray diffraction to be alpha iron, MoO3, and possibly FeMoO3. In dry argon the failure mechanism was the gradual depletion of MoS2 from the contact region by transverse flow, and the wear debris on the track at failure was alpha iron, residual MoS2, and possibly FeS.

Fusaro, R. L.↗

Graphite-fiber-reinforced polyimide liners of various compositions in plain spherical bearings

Composites made of graphite-fiber-reinforced polyimide (GFRPI) with a fiber-resin ratio (by weight) of about 1 were evaluated as molded outer-race liners in plain spherical bearings. Several compositions were examined: two types of polyimide (addition and condensation polymers), two types of graphite fiber (high and low modulus) and four powder additives (CdO, CdI2, (CF1.1)n, and MoS2). Friction and wear were measured during oscillation at 25, 200, and 315 C. It is shown that all compositions provided good lubrication in dry air, that neither type of polyimide or graphite fiber nor the additives gave a clear advantage, and that wear rates were always higher during run-in, before conditions stabilized. It is concluded that GFRPI composites are self-lubricating under all but the most extreme moisture-free conditions at 25 C. The additives are helpful only with very high loads or extremely dry environments.

Sliney, H. E.↗

Mechanisms of graphite fluoride /CFx/n lubrication

Friction, wear and wear life results were compared with optical microscope observations as a function of sliding distance for graphite fluoride rubbed films applied to three surface finishes - polished, sanded and sandblasted. The lubricating process consisted of the plastic flow of thin films of graphite fluoride between flat areas on the rider and on the metallic substrate. If the substrate was rough, flat areas were created during run-in, and the graphite fluoride (CFx)n flowed across them. Wear life was enhanced by restricting radial (or transverse) flow of the graphite fluoride from the contact region by increasing surface roughness. Valleys in the roughened substrate surface served as a reservoir for graphite fluoride and as a deposit site for wear debris. Failure resulted from the gradual depletion of graphite fluoride from the contact region with the subsequent formation of powdery metallic debris that covered both rider and disk surfaces

Fusaro, R. L.↗

Steady-state wear and friction in boundary lubrication studies

A friction and wear study was made at 20 C to obtain improved reproducibility and reliability in boundary lubrication testing. Ester-base and C-ether-base fluids were used to lubricate a pure iron rider in sliding contact with a rotating M-50 steel disk in a friction and wear apparatus. Conditions included loads of 1/2 and 1 kg and sliding velocities of 3.6 to 18.2 m/min in a dry air atmosphere and stepwise time intervals from 1 to 250 min for wear measurements. The wear rate results were compared with those from previous studies where a single 25 min test period was used. Satisfactory test conditions for studying friction and wear in boundary lubrication for this apparatus were found to be 1 kg load; sliding velocities of 7.1 to 9.1 m/min (50 rpm disk speed); and use of a time stepwise test procedure. Highly reproducible steady-state wear rates and steady-state friction coefficients were determined under boundary conditions. Wear rates and coefficients of friction were constant following initially high values during run-in periods.

Loomis, W. R.↗

Evaluation of boundary lubricants using steady-state wear and friction

A friction and wear study was made at 20 C to establish operating limits and procedures for obtaining improved reproducibility and reliability in boundary lubrication testing. Ester base and C-other base fluids were used to lubricate a pure iron rider in sliding contact with a rotating M-50 steel disk in a pin-on-disk apparatus. Results of a parametric study with varying loads and speeds slowed that satisfactory test conditions for studying the direction and wear characteristics in the boundary lubrication regime with this test device were found to be 1 kilogram load; 7 to 9 meters-per-minute (50 rpm) surface speed; dry air test atmosphere (less than 100 ppm H2O); and use of a time stepwise procedure for measuring wear. Highly reproducible steady-state wear rates resulted from the two fluid studies which had a linearity of about 99 percent after initially higher wear rates and friction coefficients during run-in periods of 20 to 40 minutes.

Loomis, W. R.↗

Effect of substrate surface finish on the lubrication and failure mechanisms of molybdenum disulfide films

An optical microscope was used to study the lubrication and failure mechanisms of rubbed (burnished) MoS2 films applied to three substrate surface finishes - polished, sanded, and sandblasted - as a function of sliding distance. The lubrication mechanism was the plastic flow of thin films of MoS2 between flat plateaus on the rider and on the metallic substrate. If the substrate was rough, flat plateaus were created during 'run-in' and the MoS2 flowed across them. Wear life was extended by increasing surface roughness since valleys in the roughened substrate served as reservoirs for MoS2 and a deposit site for wear debris. In moist air, the failure mechanism was the transformation of metallic-colored MoS2 films to a black, powdery material that was found by X-ray diffraction to consist primarily of alpha-iron and MoO3 powders. In dry argon, the failure mechanism was the gradual depletion of the MoS2 film from the contact region by transverse flow. Analysis of the wear debris on the wear track at failure showed it consisted mainly of alpha-iron and some residual MoS2. No molybdenum oxides were found.

Fusaro, R. L.↗

Effect of gamma irradiation on the friction and wear of ultrahigh molecular weight polyethylene

The effect of sterilization gamma irradiation on the friction and wear properties of ultrahigh molecular weight polyethylene (UHMWPE) sliding against stainless steel 316L in dry air at 23 C is investigated, the results to be used in the development of artificial joints which are to surgically replace diseased human joints. A pin-on-disk sliding friction apparatus is used, a constant sliding speed in the range 0.061-0.27 m/s is maintained, a normal load of 1 kgf is applied with dead weight, and the irradiation dose levels are: 0, 2.5, and 5.0 Mrad. Wear and friction data and conditions for each of the ten tests are summarized, and include: (1) wear volume as a function of the sliding distance for the irradiation levels, (2) incremental wear rate, and (3) coefficient of friction as a function of the sliding distance. It is shown that (1) the friction and wear properties of UHMWPE are not significantly changed by the irradiation doses of 2.5 and 5.0 Mrad, (2) the irradiation increases the amount of insoluble gel as well as the amount of low molecular weight material, and (3) after run-in the wear rate is either steady or gradually decreases as a function of the sliding distance.

Jones, W. R.↗

Tribological measurements on a Charnley-type artificial hip joint

A total hip simulator was used to determine the friction and wear properties of Charnley-type (316L stainless steel balls and sterile ultrahigh molecular weight polyethylene cups) hip prostheses. Three different sets of specimens were tested to 395,000, 101,500 and 233,000 walking cycles, respectively. All tests were run unlubricated, at ambient conditions (22 to 26 C, 30 to 50 percent relative humidity), at 30 walking cycles per minute, under a dynamic load simulating walking. Polyethylene cup wear rates ranged from 1.4 to 39 ten billions cu m which corresponds to dimensional losses of 4.0 to 11 microns per year. Although these wear rates are lower than those obtained from other hip simulators and from in vivo X-ray measurements, they are comparable when taking run-in and plastic deformation into account. Maximum tangential friction forces ranged from 93 to 129 N under variable load (267 to 3090 N range) and from 93 to 143 N under a static load of 3090 N. A portion of one test 250,000 walking cycles) run under dry air ( 1 percent relative humidity) yielded a wear rate almost 6 times greater than that obtained under wet air ( 70 percent relative humidity) conditions.

Jones, W. R., Jr.↗

Temperature Effects in Elastohydrodynamically Lubricated Contacts

This paper gives an overview of our current understanding of thermal phenomena in elastohydrodynamic contacts and suggests some avenues for fruitful research in the next decade. Typical measured temperatures are presented for representative conditions and ranges of operating parameters. Temperatures can range from bulk ambient temperature to several hundred degrees centigrade in fully separated elastohydrodynamic films. Although attention in the past decade has been on the full film for the purposes of understanding film thickness and traction phenomena, the more interesting conditions are in the mixed elastohydrodynamic films. These mixed conditions are both common in tribological systems and they are the conditions that border on unsuccessful run-in and failure of the elastohydrodynamic contact. In mixed film conditions local hotspots can have temperatures of the order of 1888 C which cause increased reactivity of the surfaces with surrounding materials as well as changes of the surface physical properties so important to the operation of concentrated contacts. An additional area discussed is that of the bulk system thermal transients which occur in tribological systems. These transients are frequently long in duration and have a direct bearing on the elastohydrodynamic film thickness and traction.

Ward O Winer↗