Search NASA⌕ Search

SEARCH · Search NASA

Results for “safe laser beam propagation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Optical nanofiber testbeds for benchmarking membrane-waveguide photonic integrated circuit platforms toward on-chip quantum inertial sensing

Recent advances in cold atom interferometry with optical and magnetic atom guides have set the stage for quantum inertial sensors capable of operating in dynamic environments. In this work, we present three key innovations—evanescent-field (EF) atom guides, optical nanofiber testbeds, and membrane-waveguide photonic integrated circuit (PIC) platforms—to advance EF-guided atom interferometry. First, we demonstrate EF atom guides on optical nanofiber testbeds, which serve as performance benchmarks for our membrane-waveguide PIC platforms. Second, we achieve low-power (⁠ ~ 5 mW) guiding of freely moving, laser-cooled 133 Cs atoms in two-color, traveling-wave EF optical dipole traps at the novel, heat-efficient magic wavelengths of 793 and 937 nm (i.e., “793/937-nm EF atom guides”). Concurrently, we design and fabricate membrane-waveguide PIC platforms for these EF atom guides; in our prior work, we showed that these structures safely accommodate 4–6 times the required optical trap power under vacuum and enable dense cold atom generation via magneto-optical trapping in the vicinity of the optical wavguide for efficient loading. Third, we verify preserved atomic coherence via microwave fields and EF-coupled Doppler-free Raman beams; to our knowledge, this is the first report of coherence fringes driven by co-propagating EF-coupled Raman beams with only 150 nW of total optical power. By providing a direct comparison between optical nanofiber testbeds and membrane-waveguide PIC platforms, our results lay critical groundwork for the on-chip realization of EF-guided atom interferometry and the development of fully integrated, compact, lightweight, and low-power quantum accelerometers and gyroscopes.

Orozco, Adrian [Sandia National Laboratories (SNL-↗

3013 Baseline Inner Container Report: Description, Imaging, and Analysis

This report presents consolidated findings from three microscopy studies of baseline Bagless Transfer Containers (BTCs), which are the inner containers used in DOE Standard 3013-compliant plutonium storage packages. The studies were conducted by Los Alamos National Laboratory (LANL), Savannah River National Laboratory (SRNL), and DNV, a subcontractor specializing in corrosion science. The baseline BTCs examined had not been exposed to corrosive environments, serving as control samples for comparison with destructively examined (DE) containers. Additionally, the Background section provides an overview of the BTC design, including manufacturing methods, material properties, and container configurations that may influence corrosion behavior. The primary objective of the LANL and SRNL studies was to establish reference characteristics of BTCs to distinguish manufacturing artifacts from corrosion-induced features observed in DE containers. Both laboratories used advanced microscopy techniques, including Wide Area Microscopy (WAMS), Laser Confocal Microscopy (LCM), Scanning Electron Microscopy (SEM), and Focused Ion Beam (FIB), to reveal that most surface anomalies were shallow and attributable to flow-forming processes, not corrosion. Subsurface impurities, identified as non-metallic inclusions, were also observed. DNV’s investigation focused on characterizing the mechanical and chemical properties of the BTC material to support crack growth modeling. Their findings indicate higher hardness and strength but reduced ductility—consistent with flow-formed 304L stainless steel and a higher-than-expected martensite content, in contrast to manufacturer claims. Ongoing and future studies, including Electron Backscatter Diffraction (EBSD), aim to further understand the microstructural factors influencing crack initiation and propagation. The combined studies provide a crucial baseline for distinguishing corrosion effects in DE containers, contributing to the safe and reliable long-term storage of plutonium-bearing materials.

36 MATERIALS SCIENCE↗

Electromechanical response of piezoelectric thin films subjected to large strain

The use of piezoelectric thin sensors, when subjected to large static strain levels in ultrasonic applications is reported in this paper. A novel flipped beam bending method is proposed to induce static strain level nearing twice the incipient yield strain in the beam material (~0.39%). First, the effect of static large strain on ultrasonic guided wave propagation in the beam was studied using the velocity measurements obtained from a laser Doppler vibrometer. Next, the ultrasonic response of thin sensors is studied under compressive and tensile static strain (±0.72%) with the sensors symmetrically bonded on the lower and upper surfaces, and at the same axial location. The ultrasonic guided wave response to varying levels of static strain is recorded at different center frequencies (50–400 kHz) of the narrow banded ultrasonic excitation. As a case study, the variation of the ultrasonic guided wave response of polyvinylidene difluoride (PVDF) thin sensors with center frequencies at different static strain levels was analyzed and compared with that of lead zirconate titanate (PZT) thin sensors. PZT sensors show a higher variation of sensing performance with strain when compared to PVDF sensors. Apart from static strain, the possible effects on the change in performance of sensors, such as the change in the capacitance is discussed. The characterization method provides a reusable beam arrangement to study the ultrasonic sensor performance at large static strain levels. Characterization at large strain level allows the development of fail-safe sensors even under large strain and permanent plastic deformation of structure on which they are bonded, allowing accurate ultrasonic structural health monitoring even in the presence of damage progression. Piezopolymer sensor like PVDF are least susceptible to static strain due to large yield strain and low modulus and can serve as fail-safe sensors under large strain.

Rathod, Vivek↗

Standoff Detection of Chemical Plumes Using Swept-ECQCL Remote Detection Technology: Results from EMRTC Complex Terrain Dual Tracer Experiment

As part of the Complex Terrain Dual Tracer Experiments performed in support of the LYNM program, a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) remote detection system was deployed to measure chemical plume propagation with high temporal resolution. The swept-ECQCL remote detection technology was initially developed at PNNL, and is now under further development at Opticslah, LLC under SBIR funding from DOE (DOE SBIR Phase I Project DE-SC0019855, Remote Detection Technologies, Program Manager Chris Ramos). The swept-ECQCL technology provides a single-frequency infrared laser source which is rapidly scanned over a large wavelength range to measure the infrared absorption of gases, liquids, or solids. Analysis of the measured infrared absorption spectrum is used to detect, identify, and quantify the chemical species which are present. While most previous laser-based techniques used small wavelength tuning ranges to measure only a few isolated spectral lines of a few species, the swept-ECQCL provides the large tuning range needed to measure multiple species simultaneously, and to detect broad absorption features from large molecules or condensed phase materials. In addition, the swept-ECQCL systems have high enough spectral resolution and sensitivity to measure narrow lines of small molecules and determine isotope ratios. The remote detection system for gas plumes is based on the swept-ECQCL technology, and consists of a swept-ECQCL source, infrared detector, control electronics, and beam transmitting and alignment optics. The remote detection system directs the infrared output of the swept-ECQCL to a target retro reflector typically located at ~10-10,000 m distance. The swept-ECQCL wavelength is varied continuously over a large wavelength range (>1000 nm) at rates up to 1000 Hz. The swept ECQCL light reflected from the remote target is collected and focused onto an infrared photodetector. By measuring the detector signal continuously as the swept-ECQCL wavelength is varied, a time-series of absorption spectra are measured for the gases along the beam line of-sight. Based on analysis and fitting of the measured absorption spectra, the time-dependent chemical concentrations of species are determined. Multiple species and mixtures can be detected simultaneously, for all species with absorption features above the sensor noise floor. The sensor output is thus a continuous, high-speed record of identified chemicals along with their concentrations and isotope ratios of interest. The high-speed operation enables low-noise operation in conditions of atmospheric turbulence and allows tracking of fluctuating concentrations in transient chemical plumes as needed for reliable remote detection applications. All components operate with minimal cooling requirements and no cryogens are needed. In addition, the output infrared light is invisible with an intensity below the maximum permissible exposure (MPE) threshold of 100 mW/cm2 for these infrared wavelengths and thus eye safe. The measurement concept for plume detection using the swept-ECQCL remote detection system is as follows. The ECQCL beam is directed toward a remote retro-reflector, which reflects the beam back to the ECQCL system where it is focused onto an infrared photodetector. The line-of-sight from the ECQCL system to the retro-reflector defines the measurement path. The detected infrared signal is recorded continuously and detects the absorption of molecular species along the measurement path. Before a plume release, the system measures absorption from atmospheric constituents, which in this LWIR band consist primarily of lines from H 2 O and CO 2 , with additional weaker absorption from N 2 O, NH 3 , and O 3 possibly contributing. The system then measures any changes in absorption due to the tracer compounds when they enter the measurement path. The shape of absorption features is used to distinguish and identify the different tracer compounds, and the strength of the absorption is used to determine the path-integrated concentration – also called the column density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗