Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample damage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Soft sample deformation, damage and induced electromechanical property changes in contact- and tapping-mode atomic force microscopy

Probe-induced soft sample damage in atomic force microscopy (AFM), as well as the resulting alteration of local mechanical and electrical properties of the material are explored, specifically comparing contact-mode and intermittent-contact-mode imaging methods. In our experiments, performed on conductive polymer films, induced changes are present in contact-mode imaging while they are negligible or absent in tapping-mode imaging. Here, to understand this result, a viscoelastic parameter extraction is performed, which suggests that permanent sample deformation can readily occur for tip-sample interactions with a duration on the timescale of contact-mode interactions. Using the extracted viscoelastic parameters, a dynamic AFM simulation is conducted, which suggests that the material responds more elastically with reduced or absent sample damage in tapping-mode AFM, due to the higher rate of mechanical deformation and shorter timescales.

42 ENGINEERING↗

Probing soft X-ray induced photoreduction of a model Mn-complex at cryogenic conditions

Soft X-ray absorption spectroscopy of first row transition elements at their respective L -edges provides important information about the oxidation and spin states of the metal centers. However, the associated sample damage in radiation-sensitive samples substantially alters the electronic and chemical structures of redox-active metal centers. Here, we measure the soft X-ray spectrum of the model Mn III (acac) 3 complex containing a redox-active Mn III metal center in an octahedral environment with a superconducting transition-edge sensor detector. To reduce the secondary damage resulting primarily from the diffusion of radicals and electrons, the spectra are collected at 30 K and 80 K on solid samples. Starting from the first scan, we detect the contribution of X-ray induced sample damage leading to a change in the Mn II intensity. However, at low temperatures, particularly at 30 K, we do not observe a gradual increase in the radiation damage with successive scans with the X-ray beam at the same spot. At our estimated dose of 90 kGy, we find 62% of Mn III (acac) 3 is still intact at 30 K. However, at room temperature, we see a gradual increase in radiation damage with increasing numbers of scans at the same spot, which is consistent with the possibility of increased diffusion rates of secondary radicals and electrons as noted in other studies.

L-edge spectroscopy↗

Lattice response to ambient self-irradiation of δ-phase 239 Pu-Ga alloys exposed to cryogenic temperatures

Self-irradiation in plutonium is a continuous process that introduces radiation damage ranging from point defects to nanoscale radiation damage as well as decay daughter product impurities that require to be accommodated by the host material. These changes are affecting the structure and properties of the material by lattice swelling, mechanical strengthening, and other alterations. X-ray diffraction and dilatometry studies have shown that the room temperature self-irradiation of δ-phase Pu-Ga alloys (2 and 7 at%Ga) results in swelling of the lattice that saturates after 0.1–0.2 displacement per atom (dpa) of accumulated lattice damage. Here, for a better understanding of these self- irradiation processes, defect accumulation and damage evolution, this time-of-flight neutron diffraction study investigates the impact of ambient self-irradiation effects on the structural evolution of δ-phase 239 Pu-Ga alloys exposed to cryogenic temperatures (<120 K), associated with a varied history of storage time and thermal treatments. Two key behaviors were observed in the lattice evolution after exposure to cryogenic temperatures with respect to room-temperature accumulated self-irradiation damage. Samples with no self- irradiation damage accumulation under ambient conditions showed swelling of the lattice at the end of the measurement, while samples that accumulated significant self-irradiation damage under ambient conditions showed only a partial recovery of the lattice parameter value upon completion of the measurements (cooling followed by heating back to room temperature). Possible causes of the behavior are proposed, and their associated effects are discussed.

36 MATERIALS SCIENCE↗

High-Resolution Imaging of Cellulose Organization in Cell Walls by Field Emission Scanning Electron Microscopy

Field emission scanning electron microscopy (FESEM) is a powerful tool for analyzing surface structures of biological and nonbiological samples. However, when it is used to study fine structures of nanometer-sized microfibrils of epidermal cell walls, one often encounters tremendous challenges to acquire clear and undistorted images because of two major issues: (1) Preparation of samples suitable for high resolution imaging; due to the delicateness of some plant materials, such as onion epidermal cell walls, many things can happen during sample processing, which subsequently result in damaged samples or introduce artifacts. (2) Difficulties to acquire clear images of samples which are electron-beam sensitive and prone to charging artifacts at magnifications over 100,000×. In this chapter we described detailed procedures for sample preparation and conditions for high-resolution FESEM imaging of onion epidermal cell walls. Lastly, the methods can be readily adapted for other wall materials.

59 BASIC BIOLOGICAL SCIENCES↗

D retention and depth profile behavior for single crystal tungsten with high temperature neutron irradiation

Single crystalline W (tungsten) samples irradiated at 633, 963 and 1073 K by neutrons to a damage level of 0.1 dpa were exposed to a high-flux D (deuterium) plasma at 673, 873 and 973 K, respectively, in TPE (Tritium Plasma Experiment) at INL (Idaho National Laboratory). Deuterium desorption was analyzed by TDS (Thermal Desorption Spectroscopy), and D depth profiles were determined by NRA (Nuclear Reaction Analysis) at SNL (Sandia National Laboratories). HIDT (Hydrogen Isotope Diffusion and Trapping) simulation code was applied to evaluate D behavior for neutron-damaged W at higher temperature. The D retention at depths up to 3 f.tm for the neutron-damaged sample at 673 K was two orders of magnitude larger than that for undamaged tungsten, and its D desorption spectrum had a single broad stage at around 900 K. As the neutron irradiation/plasma exposure temperature increased, D retention was largely reduced, and the desorption temperature was increased to higher temperatures above 1100 K. The D depth profiles by NRA also showed D migration toward bulk by higher temperature irradiation, compared to undamaged W. The HIDT simulation indicated that the major binding energy of D was changed from 1.43 eV to 2.07 eV at higher neutron irradiation and plasma exposure temperatures, suggesting that some vacancies and small vacancy clusters would aggregate to form larger voids, or depopulation of weak traps at high D plasma exposure temperatures. It can be said that more stable trapping sites played dominant roles in the D retention at higher neutron irradiation and plasma exposure temperature. The binding energy by HIDT simulation was almost consistent with the reported value by TMAP, but the consideration of not only total D retention measured by TDS but also D depth profile by NRA led to the more accurate D behavior in neutron-damaged W.

36 MATERIALS SCIENCE↗

Effect of X-ray free-electron laser-induced shockwaves on haemoglobin microcrystals delivered in a liquid jet

X-ray free-electron lasers (XFELs) enable obtaining novel insights in structural biology. The recently available MHz repetition rate XFELs allow full data sets to be collected in shorter time and can also decrease sample consumption. However, the microsecond spacing of MHz XFEL pulses raises new challenges, including possible sample damage induced by shock waves that are launched by preceding pulses in the sample-carrying jet. We explored this matter with an X-ray-pump/X-ray-probe experiment employing haemoglobin microcrystals transported via a liquid jet into the XFEL beam. Diffraction data were collected using a shock-wave-free single-pulse scheme as well as the dual-pulse pump-probe scheme. The latter, relative to the former, reveals significant degradation of crystal hit rate, diffraction resolution and data quality. Crystal structures extracted from the two data sets also differ. Since our pump-probe attributes were chosen to emulate EuXFEL operation at its 4.5 MHz maximum pulse rate, this prompts concern about such data collection.

59 BASIC BIOLOGICAL SCIENCES↗

Deuterium retention in MeV ion-irradiated beryllium

Beryllium, as the material of choice for the ITER first wall, will be subject to high energy neutrons during the operation of the fusion device. Such irradiation will create displacement damage in the crystal lattice, which is known to influence hydrogen isotope retention, e.g. in iron and tungsten. Here in our study, we irradiated beryllium samples with high-energy oxygen ions up to various dpa levels (0.01 dpa, 0.1 dpa, and 1 dpa) and subsequently exposed the samples to deuterium plasma at 370 K and 573 K. The amount of retained deuterium was measured by thermal desorption spectroscopy and nuclear reaction analysis and was found to decrease by about 18% in the samples damaged up to 0.1 dpa compared to the undamaged ones. Further damaging up to 1 dpa did not show any additional effects on deuterium retention. Transmission electron microscopy was used to check for the existence of bubbles after plasma exposure.

36 MATERIALS SCIENCE↗

Acoustic-based monitoring and machine learning of component status for microreactor applications

This report provides a description and assessment of recent efforts to couple acoustic-based experimental measurements and characterization with machine learning models in order to enhance structural health monitoring capabilities for nuclear microreactors. With resilient embedded sensors in development by others supported by programs funded by the US Department of Energy’s Office of Nuclear Energy, the work described herein builds upon ongoing efforts to improve non-destructive testing technology that relates measured acoustic signatures to component stresses and/or structural defects, using a combination of new experimental measurements and machine learning architectures. The experimental procedure remained similar to that developed for the previous year’s demonstration of damage detection by the authors, with the same damaged sample tested under similar applied stress conditions. Notably, a new mounting fixture was designed and implemented to improve measurement consistency and a more sophisticated laser Doppler vibrometer was employed to make high-fidelity vibration measurements. Two nominally identical sets of training data were collected for each experimental setup to better understand the repeatability of the experiment and to better test the generality of trained neural network models. Additionally, we obtained new high-quality 3D mode shapes of the damaged test article at various stress and excitation levels, providing greater insights into the physical response of the sample during testing. Previously, we demonstrated that a machine learning model based on a convolutional neural network can predict structural details of an artificially introduced interface (intact, rough cut, smooth cut), and the applied torque level. In this study, we have transitioned to graph-based neural network architectures to better develop and test a flexible framework that is more suitable to being transferred away from controlled benchtop experiments and into more applied settings where less-structured data inputs may be expected. In general, performance testing of a graph neural network on frequency-domain representations of the data indicates strong and consistent identification of test conditions for datasets recorded on damaged components. With goals of predicting damage location and other changing experimental conditions using limited datasets, predictive models using a graph neural network architecture correctly predicted the applied torque level with an accuracy of 85% using only a single measurement point and predicted within one torque level in 95% of test windows. Predictions of damage location had limited success due to the symmetry and minimal number of the damage scenarios presented during model training. Results were ambiguous as to whether the model could detect the location of the artificial damage, or if it was instead learning the location of a given measurement point on the part and subsequently detecting which points were closest to the location of the damage. This finding will be factored into upcoming planned work on damaged graphite components, where new experimental tests with a larger number and variety of damage scenarios are expected to provide improved validation of recent developments in monitoring methodology.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Gas Transport in the Insensitive High Explosive PBX 9502

Small-scale laboratory experiments were performed to analyze gas transport mechanics in PBX 9502, an insensitive high explosive (IHE) composition. Two independent investigations are reported here. First, gas permeametry and dynamic pycnometry techniques were used to measure the molecular flow (Knudsen) coefficient and the internally interconnected void fraction of pristine and thermally damaged samples in two uniaxial pressing orientations. The permeability of PBX 9502 was found to be unmeasurably low (of the same order of magnitude as PTFE) with gas transport being diffusion-dominated. Secondly, a pressure vessel experiment was developed to measure quasi-static and dynamic gas generation as the explosive was heated to self-ignition (cookoff). The gas generation results and the permeability/diffusivity findings provide evidence that PBX 9502 remains impermeable until seconds prior to self-ignition. At ignition, internal void-pressure drives macro-scale cracking and the sample becomes uniformly incorporated in the following deconsolidating deflagration. These results are discussed within the context of previous observations of pressure-dependent cookoff behavior of PBX 9502 and provide a more complete description of thermal damage evolution in this explosive composition.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Damage-free X-ray spectroscopy characterization of oxide thin films

Thin polymer or oxide films are ubiquitous components in many devices, including membranes for filtration or electrodes in electrochemical energy storage. High energy electron or x-ray probes for microscopy and spectroscopy are useful to characterize and understand these materials. However, irreversible damage by the probe radiation remains a challenge. Here, we show that graphene serves as an x-ray and electron transparent substrate that substantially reduces radiation damage of an oxide thin film. We demonstrate this using highly focused x-ray beams, which show that compared to oxide thin films supported on a substrate, graphene-supported regions show minimal changes in the x-ray spectra as a function of x-ray dose. Further, these results pave the way for the development of experimental setups that allow for long exposure time measurements with limited sample damage and substrate-directed radiation patterning.

36 MATERIALS SCIENCE↗

Assessment of simulated and observed cavitation-induced erosion damage in Spallation Neutron Source target vessels

Cavitation-induced erosion damage in different Spallation Neutron Source (SNS) target designs are simulated using explicit finite element–based techniques and compared with observations of erosion in targets after operation. The efficacy of the previously developed method, called saturation time, was evaluated using erosion-damaged samples from new target designs. A new metric called maximum bubble size was implemented under the rationale that larger cavitation bubbles will collapse more intensely. The maximum cavitation bubble size over 1 ms of simulated time was calculated based on the Rayleigh–Plesset equation for each element integration point and presented as a contour map at the vessel surface for assessing with erosion observations. SNS targets are now operated with helium gas injection to reduce cavitation damage. A simulation method using a material model for the mixture of mercury and gas bubbles was recently developed and used to account for the effect of small gas bubbles on the structural response of the target vessel. Furthermore, this work compares the new method's results with observed cavitation damage. Maps of the calculated maximum bubble size for targets operated with and without gas injection were compared with photographs of erosion damage observed in SNS targets. The patterns in maximum bubble size maps correlated well with observations of erosion patterns in target vessels after service. Advantages and challenges of the maximum bubble size simulation technique are provided, and differences between results from the previous and the newly proposed metric are discussed.

Jiang, Hao↗

Quantitative Electron Beam‐Single Atom Interactions Enabled by Sub‐20‐pm Precision Targeting

The ability to probe and control matter at the picometer scale is essential for advancing quantum and energy technologies. Scanning transmission electron microscopy offers powerful capabilities for materials analysis and modification, but sample damage, drift, and scan distortions hinder single atom analysis and deterministic manipulation. Materials analysis and modification via electron–solid interactions can be transformed by precise delivery of electrons to a specified atomic location, maintaining the beam position despite drift, and minimizing collateral dose. Here a fast, low-dose, sub-20-pm precision electron beam positioning technique is developed, “atomic lock-on,” (ALO), which offers the ability to position the beam on a specific atomic column without previously irradiating that column. This technique is used to lock onto a single selected atomic location to repeatedly measure its weak electron energy loss signal despite sample drift. Moreover, electron beam-matter interactions in single atomic events are measured with μ s time resolution. This enables observation of single-atom dynamics, such as atomic bistability, revealing partially bonded atomic configurations and recapture phenomena. This opens prospects for using electron microscopy for high-precision measurements and deterministic control of matter for quantum technologies.

2D materials↗

In vitro investigation of protein assembly by combined microscopy and infrared spectroscopy at the nanometer scale

The nanoscale structure and dynamics of proteins on surfaces has been extensively studied using various imaging techniques, such as transmission electron microscopy and atomic force microscopy (AFM) in liquid environments. These powerful imaging techniques, however, can potentially damage or perturb delicate biological material and do not provide chemical information, which prevents a fundamental understanding of the dynamic processes underlying their evolution under physiological conditions. Here, we use a platform developed in our laboratory that enables acquisition of infrared (IR) spectroscopy and AFM images of biological material in physiological liquids with nanometer resolution in a cell closed by atomically thin graphene membranes transparent to IR photons. In this work, we studied the self-assembly process of S-layer proteins at the graphene-aqueous solution interface. The graphene acts also as the membrane separating the solution containing the proteins and Ca 2+ ions from the AFM tip, thus eliminating sample damage and contamination effects. The formation of S-layer protein lattices and their structural evolution was monitored by AFM and by recording the amide I and II IR absorption bands, which reveal the noncovalent interaction between proteins and their response to the environment, including ionic strength and solvation. Our measurement platform opens unique opportunities to study biological material and soft materials in general.

59 BASIC BIOLOGICAL SCIENCES↗

Thermoresponsive polymer assemblies via variable temperature liquid-phase transmission electron microscopy and small angle X-ray scattering

Abstract Herein, phase transitions of a class of thermally-responsive polymers, namely a homopolymer, diblock, and triblock copolymer, were studied to gain mechanistic insight into nanoscale assembly dynamics via variable temperature liquid-cell transmission electron microscopy (VT-LCTEM) correlated with variable temperature small angle X-ray scattering (VT-SAXS). We study thermoresponsive poly(diethylene glycol methyl ether methacrylate) (PDEGMA)-based block copolymers and mitigate sample damage by screening electron flux and solvent conditions during LCTEM and by evaluating polymer survival via post-mortem matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI-IMS). Our multimodal approach, utilizing VT-LCTEM with MS validation and VT-SAXS, is generalizable across polymeric systems and can be used to directly image solvated nanoscale structures and thermally-induced transitions. Our strategy of correlating VT-SAXS with VT-LCTEM provided direct insight into transient nanoscale intermediates formed during the thermally-triggered morphological transformation of a PDEGMA-based triblock. Notably, we observed the temperature-triggered formation and slow relaxation of core-shell particles with complex microphase separation in the core by both VT-SAXS and VT-LCTEM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sub-10 second fly-scan nano-tomography using machine learning

Abstract X-ray computed tomography is a versatile technique for 3D structure characterization. However, conventional reconstruction algorithms require that the sample not change throughout the scan, and the timescale of sample dynamics must be longer than the data acquisition time to fulfill the stable sample requirement. Meanwhile, concerns about X-ray-induced parasite reaction and sample damage have driven research efforts to reduce beam dosage. Here, we report a machine-learning-based image processing method that can significantly reduce data acquisition time and X-ray dose, outperforming conventional approaches like Filtered-Back Projection, maximum-likelihood, and model-based maximum-a-posteriori probability. Applying machine learning, we achieve ultrafast nano-tomography with sub-10 second data acquisition time and sub-50 nm pixel resolution in a transmission X-ray microscope. We apply our algorithm to study dynamic morphology changes in a lithium-ion battery cathode under a heating rate of 50 o C min −1 , revealing crack self-healing during thermal annealing. The proposed method can be applied to various tomography modalities.

36 MATERIALS SCIENCE↗

Fluorescence intensity correlation imaging with high spatial resolution and elemental contrast using intense x-ray pulses

We theoretically investigate the fluorescence intensity correlation (FIC) of Ar clusters and Mo-doped iron oxide nanoparticles subjected to intense, femtosecond, and sub-femtosecond x-ray free-electron laser pulses for high-resolution and elemental contrast imaging. We present the FIC of Kα and Kαh emission in Ar clusters and discuss the impact of sample damage on retrieving high-resolution structural information and compare the obtained structural information with those from the coherent diffractive imaging (CDI) approach. We found that, while sub-femtosecond pulses will substantially benefit the CDI approach, few-femtosecond pulses may be sufficient for achieving high-resolution information with the FIC. Furthermore, we show that the fluorescence intensity correlation computed from the fluorescence of the Mo atoms in Mo-doped iron oxide nanoparticles can be used to image dopant distributions in the nonresonant regime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗