Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Mercury Concentrations in the Two-Toed Amphiuma ( Amphiuma means ) and the Lesser Siren ( Siren intermedia ): Validating Non-lethal Sampling Methods in Southeastern Aquatic Salamanders

The global decline of amphibians is a major conservation issue. Many stressors are recognized for this decline including exposure to environmental contaminants. Mercury (Hg) is an environmental contaminant that bioaccumulates in wildlife and can cause a variety of negative impacts across taxa, including amphibians. Amphiuma and Siren spp. can comprise a large portion of biomass within their respective ecosystems, and thus, likely serve as important predators or prey in wetland communities. However, due to their cryptic nature, little is known about their ecology, diet, and accumulation potential. Here, we sought to validate a non-lethal sampling method to quantify total mercury (THg) in two enigmatic species of aquatic salamanders: the two-toed amphiuma (Amphiuma means) and the lesser siren (Siren intermedia). We examined relationships between THg content in lethal (whole-body) and non-lethal (tail clip) samples. Tail clips were significant predictors of whole body THg (all p < 0.001), explaining 84-89% of variation in whole body THg. Average whole-body THg (mg/kg did not significantly differ between the two species (p = 0.97), and overall, they had similar whole body THg content (LESI = 0.330 ± 0.04, n = 18; AMME = 0.333 ± 0.07, n = 11). To our knowledge, these data represent the first reported Hg burdens in A. means and S. intermedia.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Estimation of the sugar cane cultivated area from LANDSAT images using the two phase sampling method

A two phase sampling method and the optimal sampling segment dimensions for the estimation of sugar cane cultivated area were developed. This technique employs visual interpretations of LANDSAT images and panchromatic aerial photographs considered as the ground truth. The estimates, as a mean value of 100 simulated samples, represent 99.3% of the true value with a CV of approximately 1%; the relative efficiency of the two phase design was 157% when compared with a one phase aerial photographs sample.

Parada, N. D. J.↗

Adjoint Klein-Nishina Sampling Methods: Efficiency, Speed and Applications

Three new rejection sampling methods for generating samples from the adjoint Klein-Nishina cross section are discussed: the two-branch rejection sampling procedure, the three-branch linear rejection sampling procedure and the three-branch inverse rejection sampling procedure. These methods have all been implemented in the Framework for REsearch in Nuclear ScIence and Engineering (FRENSIE). The efficiency and sample generation rate of each of these methods are evaluated to characterize the methods and to make recommendations regarding their use. The use of these methods in realistic transport simulations is also evaluated by incorporating a scattering function into the sampling process. Furthermore, the results of an infinite medium problem are presented to verify that the sampling procedure can be used in an adjoint Monte Carlo simulation to generate results that are in agreement with an equivalent forward simulation.

97 MATHEMATICS AND COMPUTING↗

Quantitative comparison of adaptive sampling methods for protein dynamics

Adaptive sampling methods, often used in combination with Markov state models, are becoming increasingly popular for speeding up rare events in simulation such as molecular dynamics (MD) without biasing the system dynamics. Several adaptive sampling strategies have been proposed, but it is not clear which methods perform better for different physical systems. Here, we present a systematic evaluation of selected adaptive sampling strategies on a wide selection of fast folding proteins. The adaptive sampling strategies were emulated using models constructed on already existing MD trajectories. We provide theoretical limits for the sampling speed-up and compare the performance of different strategies with and without using some a priori knowledge of the system. The results show that for different goals, different adaptive sampling strategies are optimal. In order to sample slow dynamical processes such as protein folding without a priori knowledge of the system, a strategy based on the identification of a set of metastable regions is consistently the most efficient, while a strategy based on the identification of microstates performs better if the goal is to explore newer regions of the conformational space. Interestingly, the maximum speed-up achievable for the adaptive sampling of slow processes increases for proteins with longer folding times, encouraging the application of these methods for the characterization of slower processes, beyond the fast-folding proteins considered here.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Subspace-Inclusive Sampling Method for the Computational Design of Compositionally Graded Alloys

Abstract Compositionally graded alloys, a subclass of functionally graded materials (FGMs), utilize localized variations in composition with a single metal part to achieve higher performance than traditional single material parts. In previous work [Kirk, T., Galvan, E., Malak, R., and Arroyave, R., 2018, “Computational Design of Gradient Paths in Additively Manufactured Functionally Graded Materials,” J. Mech. Des., 140, p. 111410. 10.1115/1.4040816], the authors presented a computational design methodology that avoids common issues which limit a gradient alloy’s feasibility, such as deleterious phases, and optimizes for performance objectives. However, the previous methodology only samples the interior of a composition space, meaning designed gradients must include all elements in the space throughout the gradient. Because even small amounts of additional alloying elements can introduce new deleterious phases, this characteristic often neglects potentially simpler solutions to otherwise unsolvable problems and, consequently, discourages the addition of new elements to the state space. The present work improves upon the previous methodology by introducing a sampling method that includes subspaces with fewer elements in the design search. The new method samples within an artificially expanded form of the state space and projects samples outside the true region to the nearest true subspace. This method is evaluated first by observing the sample distribution in each subspace of a 3D, 4D, and 5D state space. Next, a parametric study in a synthetic 3D problem compares the performance of the new sampling scheme to the previous methodology. Lastly, the updated methodology is applied to design a gradient from stainless steel to equiatomic NiTi that has practical uses such as embedded shape memory actuation and for which the previous methodology fails to find a feasible path.

Engineering↗

Rietveld analysis using powder diffraction data with anomalous scattering effect obtained by focused beam flat sample method

Focused-beam flat-sample method (FFM) is a new trial for synchrotron powder diffraction method, which is a combination of beam focusing optics, flat shape powder sample and area detectors. The method has advantages for X-ray diffraction experiments applying anomalous scattering effect (anomalous diffraction), because of 1. Absorption correction without approximation, 2. High intensity X-rays of focused incident beams and high signal noise ratio of diffracted X-rays 3. Rapid data collection with area detectors. We applied the FFM to anomalous diffraction experiments and collected synchrotron X-ray powder diffraction data of CoFe{sub 2}O{sub 4} (inverse spinel structure) using X-rays near Fe K absorption edge, which can distinguish Co and Fe by anomalous scattering effect. We conducted Rietveld analyses with the obtained powder diffraction data and successfully determined the distribution of Co and Fe ions in CoFe{sub 2}O{sub 4} crystal structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluation of surface sampling method performance for Bacillus Spores on clean and dirty outdoor surfaces.

Recovery of Bacillus atrophaeous spores from grime-treated and clean surfaces was measured in a controlled chamber study to assess sampling method performance. Outdoor surfaces investigated by wipe and vacuum sampling methods included stainless steel, glass, marble and concrete. Bacillus atrophaeous spores were used as a surrogate for Bacillus anthracis spores in this study designed to assess whether grime-coated surfaces significantly affected surface sampling method performance when compared to clean surfaces. A series of chamber tests were carried out in which known amounts of spores were allowed to gravitationally settle onto both clean and dirty surfaces. Reference coupons were co-located with test coupons in all chamber experiments to provide a quantitative measure of initial surface concentrations of spores on all surfaces, thereby allowing sampling recovery calculations. Results from these tests, carried out under both low and high humidity conditions, show that spore recovery from grime-coated surfaces is the same as or better than spore recovery from clean surfaces. Statistically significant differences between method performance for grime-coated and clean surfaces were observed in only about half of the chamber tests conducted.

36 MATERIALS SCIENCE↗

A multi-threshold sampling method for TOF PET signal processing

As an approach to realizing all-digital data acquisition for positron emission tomography (PET), we have previously proposed and studied a multithreshold sampling method to generate samples of a PET event waveform with respect to a few user-defined amplitudes. In this sampling scheme, one can extract both the energy and timing information for an event. In this paper, we report our prototype implementation of this sampling method and the performance results obtained with this prototype. The prototype consists of two multi-threshold discriminator boards and a time-to-digital converter (TDC) board. Each of the multi-threshold discriminator boards takes one input and provides up to 8 threshold levels, which can be defined by users, for sampling the input signal. The TDC board employs the CERN HPTDC chip that determines the digitized times of the leading and falling edges of the discriminator output pulses. We connect our prototype electronics to the outputs of two Hamamatsu R9800 photomultiplier tubes (PMTs) that are individually coupled to a 6.25 x 6.25 x 25mm{sup 3} LSO crystal. By analyzing waveform samples generated by using four thresholds, we obtain a coincidence timing resolution of about 340 ps and an {approx}18% energy resolution at 511 keV. We are also able to estimate the decay-time constant from the resulting samples and obtain a mean value of 44 ns with an {approx}9 ns FWHM. In comparison, using digitized waveforms obtained at a 20 GSps sampling rate for the same LSO/PMT modules we obtain {approx}300 ps coincidence timing resolution, {approx}14% energy resolution at 511 keV, and {approx}5 ns FWHM for the estimated decay-time constant. Details of the results on the timing and energy resolutions by using the multi-threshold method indicate that it is a promising approach for implementing digital PET data acquisition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PySAGES: flexible, advanced sampling methods accelerated with GPUs

Abstract Molecular simulations are an important tool for research in physics, chemistry, and biology. The capabilities of simulations can be greatly expanded by providing access to advanced sampling methods and techniques that permit calculation of the relevant underlying free energy landscapes. In this sense, software that can be seamlessly adapted to a broad range of complex systems is essential. Building on past efforts to provide open-source community-supported software for advanced sampling, we introduce PySAGES, a Python implementation of the Software Suite for Advanced General Ensemble Simulations (SSAGES) that provides full GPU support for massively parallel applications of enhanced sampling methods such as adaptive biasing forces, harmonic bias, or forward flux sampling in the context of molecular dynamics simulations. By providing an intuitive interface that facilitates the management of a system’s configuration, the inclusion of new collective variables, and the implementation of sophisticated free energy-based sampling methods, the PySAGES library serves as a general platform for the development and implementation of emerging simulation techniques. The capabilities, core features, and computational performance of this tool are demonstrated with clear and concise examples pertaining to different classes of molecular systems. We anticipate that PySAGES will provide the scientific community with a robust and easily accessible platform to accelerate simulations, improve sampling, and enable facile estimation of free energies for a wide range of materials and processes.

Chemistry↗

A New On-the-Fly Sampling Method for Incoherent Inelastic Thermal Neutron Scattering Data in MCNP6

At thermal energies, the scattering of neutrons in a system is complicated by the comparable velocities of the neutron and target, resulting in competing upscattering and downscattering events. The neutron wavelength is also similar in size to the target's interatomic spacing making the scattering process a quantum mechanical problem. Because of the complicated nature of scattering at low energies, the thermal data files in ACE format used in continuous-energy Monte Carlo codes are quite large { on the order of megabytes for a single temperature and material. In this paper, a new storage and sampling method is introduced that is orders of magnitude less in size and is used to sample scattering parameters at any temperature on-the-fly. In addition to the reduction in storage, the need to pre-generate thermal scattering data tables at fine temperatures has been eliminated. This is advantageous for multiphysics simulations which may involve temperatures not known in advance. A new module was written for MCNP6 that bypasses the current S(α,β) table lookup in favor of the new format. The new on-the-fly sampling method was tested for graphite for two benchmark problems at ten temperatures: 1) an eigenvalue test with a fuel compact of uranium oxycarbide fuel homogenized into a graphite matrix, 2) a surface current test with a \broomstick" problem with a monoenergetic point source. The largest eigenvalue difference was 152pcm for T= 1200K. For the temperatures and incident energies chosen for the broomstick problem, the secondary neutron spectrum showed good agreement with the traditional S(α,β) sampling method. These preliminary results show that sampling thermal scattering data on-the-fly is a viable option to eliminate both the storage burden of keeping thermal data at discrete temperatures and the need to know temperatures before simulation runtime.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ALARA ASSESSMENT OF SETTLER SLUDGE SAMPLING METHODS

The purpose of this assessment is to compare underwater and above water settler sludge sampling methods to determine if the added cost for underwater sampling for the sole purpose of worker dose reductions is justified. Initial planning for sludge sampling included container, settler and knock-out-pot (KOP) sampling. Due to the significantly higher dose consequence of KOP sludge, a decision was made to sample KOP underwater to achieve worker dose reductions. Additionally, initial plans were to utilize the underwater sampling apparatus for settler sludge. Since there are no longer plans to sample KOP sludge, the decision for underwater sampling for settler sludge needs to be revisited. The present sampling plan calls for spending an estimated $2,500,000 to design and construct a new underwater sampling system (per A21 C-PL-001 RevOE). This evaluation will compare and contrast the present method of above water sampling to the underwater method that is planned by the Sludge Treatment Project (STP) and determine if settler samples can be taken using the existing sampling cart (with potentially minor modifications) while maintaining doses to workers As Low As Reasonably Achievable (ALARA) and eliminate the need for costly redesigns, testing and personnel retraining.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Foldamer architectures of triazine-based sequence-defined polymers investigated with molecular dynamics simulations and enhanced sampling methods

Triazine-based sequence-defined polymers have recently been developed that are biomimetic and robust (Grate \latin{et al.} Angewandte Chemie 2016). In molecular dynamics (MD) simulations, the triazine polymers were shown to form linear nanorod foldamers through hydrogen bonding and $\pi$-$\pi$ interactions. The nanorod foldamers have motifs resembling those of DNA, $\alpha$-helices, and $\beta$-sheets, and have potential to be useful building blocks for new macromolecules and materials. To understand the formation of nanorod foldamers, we investigate how linker structures in the middle of the triazine polymers lead to folding using MD simulations. We found that a variety of linkers can participate in folding, but that specific linker structures are more favorable than others, depending on the polymer length. Folding of hexamers into well-defined nanorod foldamers was most favorable with pentanediamine and \emph{ortho}-xylenediamine linkers in the center of the polymers. Foldamers with \emph{ortho}-xylenediamine linkers in the center were investigated for longer polymers, i.e., octamers and decamers, using two different enhanced sampling methods, since regular MD simulations had failed to show any folding for these longer polymers. In particular, the recently developed concurrent adaptive sampling (CAS) algorithm (Ahn \latin{et al.} J. Chem. Phys. 2017) and replica exchange molecular dynamics (REMD) were used. We found that the two enhanced sampling methods did lead to the observation of foldamers, and that REMD revealed new foldamer architectures where \emph{cis}-\emph{trans} isomerizations had occurred. Foldamer formation, diversity, and the strengths and limitations of simulation techniques are discussed. These findings provide new insights into the diversity of foldamer architectures for a new type of biomimetic synthetic polymer.

Foldamers, Nanorods, Free energy landscapes, Molec↗

Measurement of vapor phase mercury emissions at coal-fired power plants using regular and speciating sorbent traps with in-stack and out-of-stack sampling methods

A systematic investigation of sorbent-trap sampling, which is a method that uses paired sorbent traps to measure total vapor phase mercury (Hg), was carried out at two coal-fired power plants. The objective of the study was to evaluate the effects (if any) on data quality when the following aspects of the sorbent trap method are varied: (a) sorbent trap configuration; (b) sampling time; and (c) analytical technique. Also, the performance of a speciating sorbent trap (i.e., a trap capable of separating elemental Hg from oxidized Hg), was evaluated by direct comparison against the Ontario Hydro (OH) reference method. Flue gas samples were taken using both 'regular' and modified sorbent trap measurement systems. Both short-term (1.5 h) and long-term (18 h to 10 days) samples were collected. The in-stack and out-of-stack sampling methods produced satisfactory relative accuracy results for both the short-term and long-term testing. For the short-term tests, the in-stack sampling results compared more favorably to the OH method than did the out-of-stack results. The relative deviation between the paired traps was considerably higher for the short-term out-of-stack tests than for the long-term tests. A one-way analysis of variance (ANOVA), showed a statistically significant difference (p < 0.1) between the direct combustion and wet-chemistry analytical methods used in the study; the results from the direct combustion method were consistently higher than the wet-chemistry results. The evaluation of the speciating mercury sorbent trap demonstrated that the trap is capable of providing reasonably accurate total mercury concentrations and speciation data that are somewhat comparable to data obtained with the OH method. 5 refs., 4 figs., 8 tabs.

01 COAL, LIGNITE, AND PEAT↗

A flexible importance sampling method for integrating subgrid processes

Numerical models of weather and climate need to compute grid-box-averaged rates of physical processes such as microphysics. These averages are computed by integrating subgrid variability over a grid box. For this reason, an important aspect of atmospheric modeling is spatial integration over subgrid scales. The needed integrals can be estimated by Monte Carlo integration. Monte Carlo integration is simple and general but requires many evaluations of the physical process rate. To reduce the number of function evaluations, this paper describes a new, flexible method of importance sampling. It divides the domain of integration into eight categories, such as the portion that contains both precipitation and cloud, or the portion that contains precipitation but no cloud. It then allows the modeler to prescribe the density of sample points within each of the eight categories. The new method is incorporated into the Subgrid Importance Latin Hypercube Sampler (SILHS). The resulting method is tested on drizzling cumulus and stratocumulus cases. In the cumulus case, the sampling error can be considerably reduced by drawing more sample points from the region of rain evaporation.

54 ENVIRONMENTAL SCIENCES↗

Chord length sampling method for analyzing VHTR unit cells in continuous energy simulations

The chord length sampling method (CLS) is studied in the continuous energy simulations by applying it to analyzing two types of Very High Temperature Gas-cooled Reactor (VHTR) unit cells: the fuel compact cell in the prismatic type VHTR and the fuel pebble cell in the pebble-bed type VHTR. Infinite multiplication factors of the unit cells are calculated by the CLS and compared to the benchmark simulations at different volume packing fractions from 5% to 30%. It is shown that the accuracy of the CLS is affected by the boundary effect, which is induced by the CLS procedure itself and results in a reduction in the total volume packing fraction of the fuel particles. To mitigate the boundary effect, three correction schemes based on the research of 1) Murata et al. 2) Ji and Martin 3) Griesheimer et al. are used to improve the accuracy by applying a corrected value of the volume packing fraction to the CLS. These corrected values are calculated based on 1) a simple linear relationship, 2) an iterative self-consistent simulation correction method, and 3) a theoretically derived non-linear relationship, respectively. The CLS simulation using the corrected volume packing fraction shows excellent improvements in the infinite multiplication factors for the VHTR unit cells. Ji and Martin's self-consistent correction method shows the best improvement. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Field Degassing as a New Sampling Method for 14 C Analyses in Old Groundwater

Radiocarbon ( 14 C) activity in groundwater can be used to determine subsurface residence time up to ~40 kyr, providing crucial information on dynamic properties of groundwater and on paleoclimate. However, commonly applied sampling methods for dissolved inorganic carbon (DIC- 14 C) are prone to low level of modern atmospheric contamination, resulting in underestimation of groundwater ages that cluster around 30–40 kyr. We extract CO 2 gas from groundwater using a device originally developed for studies of noble gas radionuclides. Carbon is collected in the gas phase, eliminating the possibility of fostering microbial activities and aqueous chemical reactions during sample storage. This method collects CO 2 - 14 C and radiokrypton ( 81 Kr and 85 Kr) samples simultaneously. The presence of any shorter-lived 85 Kr is used to evaluate the degree of atmospheric contamination during sampling or mixing of young groundwater. Most groundwater samples showed lower CO 2 - 14 C activities than those of DIC- 14 C, presumably due to the absence of atmospheric contamination. Samples with 81 Kr age exceeding 150 kyr have no detectable CO 2 - 14 C except where mixing sources of young groundwater is suspected. Furthermore these field data serve as confirmations for the reliability of the newly presented sample collection and CO 2 - 14 C method, and for the outstanding roles of radiokrypton isotopes in characterizing old groundwater.

54 ENVIRONMENTAL SCIENCES↗

Development of a phonon-based sampling method for thermal neutron scattering data

Simulations of reactor systems require access to accurate nuclear data. For many systems, thermal neutron scattering data can have large effects on the eigenvalue and neutron flux distributions. Inelastic thermal neutron scattering can excite or de-excite vibrational, rotational, and translational modes in a material, so thermal scattering evaluations are often obtained by summing over the number of phonons created/destroyed by a scattering event. In recent years, the thermal scattering cross sections and angular distributions have greatly improved in accuracy, but the format in which this data is delivered to simulation codes has remained virtually unchanged. Thermal scattering data is typically either compiled into large tables and sorted by incoming neutron energy, outgoing neutron energy, scattering angle, and material temperature, or represented as cumulative distribution functions of momentum exchange or energy exchange. Either method can be quite memory intensive when fine bins are used. In an effort to decrease the amount of space that processed thermal scattering data requires, an alternate format is proposed. The phonon-based sampling method introduced here can sample the number of phonons excited for each collision, the change in neutron energy, and the scattering angle while avoiding pre-computed angular bins and limiting the amount of data that is dependent on incoming energy. Through this method, the generation and storage of large interpolation tables is avoided, which could have benefits in both memory storage and accuracy. While the initial implementation of this method is slower than current alternatives, it is significantly more resistant to grid coarseness errors and has good potential for improvement. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗