Search NASA⌕ Search

SEARCH · Search NASA

Results for “sapphire optics & windows”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Sapphire advanced mitigation process: wet etch to expose sub-surface damage and increase laser damage resistance and mechanical strength

In this study, a novel, to the best of our knowledge, method of wet chemical etching of sapphire workpieces (such as optics, wafers, windows, and cones), called the sapphire advanced mitigation process (or sapphire AMP), has been developed that exposes sub-surface mechanical damage created during the optical fabrication process and significantly enhances the surface laser damage resistance (> 2×) and mechanical strength (up to ~ 2.6×). Sapphire AMP involves first treating the workpiece with a mixture of sulfuric and phosphoric acid ([H 2 SO 4 ]:[H 3 PO 4 ]= 1 : 3) at 220°C, followed with phosphoric acid at 160°C, then with sodium hydroxide base (NaOH) and surfactant at 40°C, and finally with a high-pressure deionized water spray rinse. Sapphire AMP has been demonstrated on both A- and C-plane sapphire workpieces. The mechanism of this etch process involves the reaction of the sapphire (Al 2 O 3 ) surface with sulfuric acid (H 2 SO 4 ) forming aluminum sulfate [Al2(SO4)3], which has low solubility. The high phosphoric acid content in the first and second steps of sapphire AMP results in the efficient conversion of Al 2 (SO 4 ) 3 to aluminum phosphate (AlPO 4 ), which is very soluble, greatly reducing reaction product redeposition on the workpiece surface. Sapphire AMP is shown to expose sub-surface mechanical damage on the sapphire surface created during the grinding and polishing processes, whose etched morphology has either isotropic or anisotropic evolution depending on the nature of the initial surface damage. Sapphire AMP was also designed to remove the key known surface, laser absorbing precursors (namely, foreign chemical impurities, the fracture surface layer of preexisting sub-surface damage, and reaction product or foreign species redeposition or precipitation). Static and sliding indention induced surface microfractures on sapphire are shown after sapphire AMP to have a significant decrease in the fast photoluminescence intensity (a known metric for measuring the degree of laser damaging absorbing precursors). In addition, the onset of laser damage (at 351 nm 3 ns) on sapphire AMP treated workpieces was shown to increase in fluence from ~ 4 to >9.5J/cm 2 . Finally, biaxial ball-on-ring mechanical tests on sapphire disks showed an increase in the failure stress from 340 MPa (with pre-existing 28 µm flaws) to ~ 900MPa after sapphire AMP, which is attributed to the blunting of the surface microfractures.

36 MATERIALS SCIENCE↗

An all-digital associated particle imaging system for the 3D determination of isotopic distributions

Associated particle imaging (API) is a non-destructive nuclear technique for the 3D determination of isotopic distributions. By detecting the alpha particle associated with the emitted neutron in the deuterium–tritium fusion reaction with a position- and time-resolving detector, the direction of the 14.1 MeV neutron and its time of emission can be determined. Employing this method, isotope characteristic gamma rays emitted in inelastic neutron scattering events can be correlated with the neutron interaction location. Here, an API system consisting of a sealed-type neutron generator, gamma detectors, and a position-sensitive alpha detector was designed, constructed, and characterized. The system was tested with common soil elements and shown to be sensitive to 12 C, 16 O, 28 Si, 27 Al, and 56 Fe. New aspects of our approach are the use of a yttrium–aluminum–perovskite scintillator, using a sapphire window instead of a fiber-optic faceplate for light transport to the photomultiplier, and the all-digital data acquisition system. We present a description of the system with simulations and experimental results that show a position resolution on the alpha detector of 1 mm, a depth resolution using a LaBr 3 detector of 6.2 cm, and an angular resolution of 4.5°. Additionally, we present single-element gamma response measurements for the elements mentioned above together with a comparison to Monte Carlo simulations (MCNP6).

47 OTHER INSTRUMENTATION↗

Passively pumped, polycrystalline ceramic high and ultra-high vacuum chambers

A sealed, passively pumped, polycrystalline ceramic vacuum chamber and method for fabricating the chamber are disclosed. The body of the vacuum chamber is made from a polycrystalline ceramic, for example, alumina. The vacuum chamber includes one or more windows made from a transparent ceramic, for example, sapphire, to accommodate optical access, while remaining amorphous-glass free to minimize or eliminate helium permeation. The vacuum chamber components are joined via laser welding or furnace brazing and the completed chamber is bakeable at temperatures up to 400° C. The vacuum chamber can operate at high or ultra-high vacuum pressures for an extended period through the use of one or more getter-based pumps. The vacuum chamber may include one or more atomic sources depending upon the application.

Walker, Charles A.↗

Investigation of warm dense matter by combining static and dynamic compression

Shock-compressing material samples that are precompressed with diamond-anvil cells (DACs) enables benchmarking equation of state measurements over a wide range of high-pressure conditions, in particular, warm dense matter relevant to planetary science, astrophysics, and inertial confinement fusion. These targets provide optical access to the shocked sample, so optical velocity interferometry and pyrometry are typical diagnostics. We present a scaling for the coupling of the laser drive to the shock pressure in DACs based on over 150 prior experiments that can be used to design future experiments. For initial static pressures ≤ 5 GPa, using a sapphire window mitigates the effect of photoionization compared to diamond windows and allows the measurement of shock pressures up to 1 TPa with optical diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Visualization of Two-phase Flow Maldistribution in Brazed Plate Heat Exchangers

Brazed plate heat exchangers (BPHEs) are widely used in refrigeration and HVAC applications, but are susceptible to two-phase flow maldistribution especially when operated as evaporators. Existing visualization approaches are either limited to idealized conditions or suffer from poor optical transparency. This paper presents a novel visualization method in which one edge of a BPHE, parallel to the refrigerant inlet or outlet port, is removed by wire electrical discharge machining and replaced with a flat, transparent plate. The planar geometry allows the use of optically and infrared (IR)-transparent materials, enabling both high-speed videography and IR thermography of the two-phase flow at the channel entrances and exits. Preliminary tests with R134a and R1234ze(Z) at saturation temperatures between 5 °C and 15 °C demonstrate that distinct two-phase flow patterns in the inlet header can be clearly identified and differentiated under realistic operating conditions. Potentials of optical flow analysis of high-speed videos are shown to provide objective, quantitative indicators for flow regime characterization and comparison. IR imaging of the outlet port reveals non-uniform temperature distributions at the channel exits, providing independent evidence of maldistribution across the channel stack. Limitations of IR temperature accuracy due to the spectral properties of the sapphire window are discussed, and directions for improvement are identified.

Hausherr, Carsten [Technical University of Berlin ↗