HyspIRI High-Temperature Saturation Study

As part of the precursor activities for the HyspIRI mission, a small team was assembled to determine the optimum saturation level for the mid-infrared (4-?m) channel, which is dedicated to the measurement of hot targets. Examples of hot targets include wildland fires and active lava flows. This determination took into account both the temperature expected for the natural phenomena and the expected performance of the mid-infrared channel as well as its overlap with the other channels in the thermal infrared (7.5-12 ?m) designed to measure the temperature of lower temperature targets. Based on this work, the hot target saturation group recommends a saturation temperature of 1200 K for the mid-infrared channel. The saturation temperature of 1200 K represents a good compromise between the prevention of saturation and sensitivity to ambient temperature.

saturation↗

Experimental Investigation of Heat Pipe Startup Under Reflux Mode

In the absence of body forces such as gravity, a heat pipe will start as soon as its evaporator temperature reaches the saturation temperature. If the heat pipe operates under a reflux mode in ground testing, the liquid puddle will fill the entire cross sectional area of the evaporator. Under this condition, the heat pipe may not start when the evaporator temperature reaches the saturation temperature. Instead, a superheat is required in order for the liquid to vaporize through nucleate boiling. The amount of superheat depends on several factors such as the roughness of the heat pipe internal surface and the gravity head. This paper describes an experimental investigation of the effect of gravity pressure head on the startup of a heat pipe under reflux mode. In this study, a heat pipe with internal axial grooves was placed in a vertical position with different tilt angles relative to the horizontal plane. Heat was applied to the evaporator at the bottom and cooling was provided to the condenser at the top. The liquid-flooded evaporator was divided into seven segments along the axial direction, and an electrical heater was attached to each evaporator segment. Heat was applied to individual heaters in various combinations and sequences. Other test variables included the condenser sink temperature and tilt angle. Test results show that as long as an individual evaporator segment was flooded with liquid initially, a superheat was required to vaporize the liquid in that segment. The amount of superheat required for liquid vaporization was a function of gravity pressure head imposed on that evaporator segment and the initial temperature of the heat pipe. The most efficient and effective way to start the heat pipe was to apply a heat load with a high heat flux to the lowest segment of the evaporator.

Thermal Control Systems↗

Development of a Flow Stabilization Algorithm Enabling Measurement of Low Oxygen Concentrations in Liquid Sodium

To enhance the automated control of the plugging meter (PM) and thereby enhance detection fidelity in ultralow oxygen environments [≤1 parts per million by weight (wppm)], a novel proportional derivative controller has been implemented with conventional PM hardware. This ramp sign stabilized flow (RSSF) controller manipulates the sign (heating or cooling direction) at a fixed rate, enabling precise temperature adjustment around the saturation temperature of the bulk sodium. This adjustment helps maintain flow stability in a partially formed sodium oxide plug, thus greatly reducing the temperature amplitude in the plugging cycle and promoting simple and accurate oxygen determinations in addition to an increased sampling rate. Rather than relying on the subjective nature of indexing the time when the flow rate changes due to the plugging or unplugging onset to the PM temperature, a running average of the correlated oxygen concentration with time over multiple plugging events can provide oxygen readings ranging from an absolute uncertainty of 500 wppb in real time to less than 50 wppb for a 24-h sampling window. Finally, the RSSF controller was tested at 508 ± 7 wppb with measured oxygen of 542 ± 179 wppb, further reducing the variance between the saturation temperature and the plugging temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary Thermal-Hydraulic Analysis of the UTA–2 Subcritical Linear Accelerator–Driven System

The National Nuclear Security Administration’s mission includes establishing a reliable supply of 99 Mo without highly enriched uranium. Oak Ridge National Laboratory (ORNL) supports this objective through collaborative research and development with industrial partners. Niowave Inc., a current partner, is currently designing a subcritical linear accelerator-driven system (ADS) and preparing for the US Nuclear Regulatory Commission’s licensing process. Niowave’s system has the potential to efficiently supply medical radioisotopes. The technology includes a superconducting electron accelerator and a pile of both natural and low-enriched uranium (LEU) targets. The process fissions uranium and many valuable isotopes can then be extracted from the targets. Niowave is currently iterating through conceptual and detailed design processes for several system sizes. This report discusses UTA–2, which is at the demonstration stage. UTA–2 will validate numerical modeling results with experimental measurements before progressing to the detailed design of UTA–3, the commercial-sized ADS. The thermal-hydraulic behavior of the UTA–2 core design was numerically investigated using STAR-CCM+, as described in this report. STAR-CCM+, a state-of-the-art computational fluid dynamics (CFD) software that was commercially developed by Siemens, has an extensive user base and a set of validation studies. It is also compliant with the American Society of Mechanical Engineers’ Nuclear Quality Assurance 1 standard. Three cases are investigated in this report. Case 1 quantified the temperature field within the UTA–2 assembly and water tank using only conduction as the method of thermal energy transport. This simplified approach was overly conservative and yielded wetted cladding temperatures above the coolant saturation temperature. In this case, the maximum temperature of the wetted cladding surface of the highest power rod exceeded the saturation temperature of water by 63.8°C. Because of the overly conservative approach taken in Case 1 and its negative subcooled margin, buoyancy-driven natural circulation flow physics were implemented in Case 2. Adding coolant motion significantly distributed the thermal energy of the system through convective heat transfer. This relatively small amount of convective heat transfer significantly reduced system temperatures and increased the subcooled margin from –63.8 to 61.3°C. This margin confirmed that no boiling was expected during normal operation of UTA–2 at 230 W. Case 3 had no additional physics models but considered an overpower event during which the power of each LEU and natural uranium rod was at its respective peak values. This resulted in a study with the total assembly power equal to 176% of the nominal power of 230 W considered in Cases 1 and 2. The resulting natural circulation flows were slightly enhanced. The subcooled margin decreased slightly to 46.3°C, which is still a significant margin to local boiling of the water within the tank. This margin confirmed that no boiling was expected during an abnormal operation of UTA–2 at 406 W.

07 ISOTOPE AND RADIATION SOURCES↗

Recovering Residual Xenon Propellant for an Ion Propulsion System

Future nuclear-powered Ion-Propulsion- System-propelled spacecraft such as Jupiter Icy Moon Orbiter (JIMO) will carry more than 10,000 kg of xenon propellant. Typically, a small percentage of this propellant cannot be used towards the end of the mission because of the pressure drop requirements for maintaining flow. For large missions such as JIMO, this could easily translate to over 250 kg of unusable xenon. A proposed system, the Xenon Recovery System (XRS), for recovering almost all of the xenon remaining in the tank, would include a cryopump in the form of a condenser/evaporator that would be alternatively cooled by a radiator, then heated electrically. When the pressure of the xenon in the tank falls below 0.7 MPa (100 psia), the previously isolated XRS will be brought online and the gas from the tank would enter the cryopump that is initially cooled to a temperature below saturation temperature of xenon. This causes xenon liquefaction and further cryopumping from the tank till the cryopump is full of liquid xenon. At this point, the cryopump is heated electrically by small heaters (70 to 80 W) to evaporate the liquid that is collected as high-pressure gas (<7 MPa; 1,000 psia) in an intermediate accumulator. Check valves between the tank and the XRS prevent the reverse flow of xenon during the heating cycle. The accumulator serves as the high-pressure source of xenon gas to the Xenon Feed System (XFS) downstream of the XRS. This cycle is repeated till almost all the xenon is recovered. Currently, this system is being baselined for JIMO.

Ganapathi, Gani↗

Loop Heat Pipe Transient Behavior Using Heat Source Temperature for Set Point Control with Thermoelectric Converter on Reservoir

The LHP operating temperature is governed by the saturation temperature of its reservoir. Controlling the reservoir saturation temperature is commonly done by cold biasing the reservoir and using electrical heaters to provide the required control power. With this method, the loop operating temperature can be controlled within 0.5K or better. However, because the thermal resistance that exists between the heat source and the LHP evaporator, the heat source temperature will vary with its heat output even if the LHP operating temperature is kept constant. Since maintaining a constant heat source temperature is of most interest, a question often raised is whether the heat source temperature can be used for LHP set point temperature control. A test program with a miniature LHP was carried out to investigate the effects on the LHP operation when the control temperature sensor was placed on the heat source instead of the reservoir. In these tests, the LHP reservoir was cold-biased and was heated by a control heater. Test results show that it was feasible to use the heat source temperature for feedback control of the LHP operation. In particular, when a thermoelectric converter was used as the reservoir control heater, the heat source temperature could be maintained within a tight range using a proportional-integral-derivative or on/off control algorithm. Moreover, because the TEC could provide both heating and cooling to the reservoir, temperature oscillations during fast transients such as loop startup could be eliminated or substantially reduced when compared to using an electrical heater as the control heater.

Ku, Jentung↗

Loop Heat Pipe Operation Using Heat Source Temperature for Set Point Control

The LHP operating temperature is governed by the saturation temperature of its reservoir. Controlling the reservoir saturation temperature is commonly accomplished by cold biasing the reservoir and using electrical heaters to provide the required control power. Using this method, the loop operating temperature can be controlled within +/- 0.5K. However, because of the thermal resistance that exists between the heat source and the LHP evaporator, the heat source temperature will vary with its heat output even if LHP operating temperature is kept constant. Since maintaining a constant heat source temperature is of most interest, a question often raised is whether the heat source temperature can be used for LHP set point temperature control. A test program with a miniature LHP has been carried out to investigate the effects on the LHP operation when the control temperature sensor is placed on the heat source instead of the reservoir. In these tests, the LHP reservoir is cold-biased and is heated by a control heater. Tests results show that it is feasible to use the heat source temperature for feedback control of the LHP operation. Using this method, the heat source temperature can be maintained within a tight range for moderate and high powers. At low powers, however, temperature oscillations may occur due to interactions among the reservoir control heater power, the heat source mass, and the heat output from the heat source. In addition, the heat source temperature could temporarily deviate from its set point during fast thermal transients. The implication is that more sophisticated feedback control algorithms need to be implemented for LHP transient operation when the heat source temperature is used for feedback control.

Ku, Jentung↗

Enhanced pool boiling heat transfer using novel inverted trapezoid microgroove structures

Pool boiling heat transfer improvements with enhanced surfaces have been extensively studied for various hydrofluorocarbon (HFC) refrigerants. However, there is a limited number of studies in the open literature that focus on the pool boiling heat transfer characteristics of hydrofluoroolefin (HFO) refrigerants on enhanced surfaces. This study aims to address this gap by analyzing the pool boiling behavior of HFO refrigerants, specifically R1234yf and R1234ze(E). Experiments were conducted on both plain surfaces and novel inverted trapezoid microgroove structures. Further, the experimental results indicate that the microgroove structures can improve heat transfer coefficients by up to 80% compared to plain surfaces. Additionally, the performance of R1234yf and R1234ze(E) was compared to that of R134. It was observed that R1234yf exhibited comparable performance to R134a, while R1234ze(E) showed slightly lower performance. To assess the influence of saturation temperature on pool boiling heat transfer, tests were conducted at different saturation temperatures of 15℃, 25℃, and 35℃. The findings revealed that the pool boiling heat transfer coefficient increases with rising saturation temperature.

42 ENGINEERING↗

Simple Heat Pipe Model

This is a simple model designed to run fast but still maintain the key physics and feedback mechanisms of a heat pipe. First, the capillary pressure is a function of the liquid working fluid volume fraction. Second, the boiling and condensation are based on the saturation temperature that is based on the heat pipe pressure. When the pressure goes up, the saturation temperature goes up and the vapor rains on the wick. When the pressure goes down, the saturation temperature goes down and the liquid in the entire wick boils. This is how the heat pipe adjusts to stay robust under different temperatures and heat fluxes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Reliability of Copper Inverse Opal Surfaces for Extreme-Heat-Flux Micro-Coolers in Low-Global-Warming-Potential Refrigerant R-1233zd Pool Boiling Experiments

This presentation provides a brief snapshot of the InterPACK paper InterPACK2023-113781. The paper explores copper inverse opal (CIO) surface reliability in pool boiling experiments in water and a new, low-global-warming-potential (GWP = 1) hydrofluoroolefin (HFO) refrigerant R-1233zd. The CIO-based structure is intended to develop enhanced two-phase heat transfer surfaces for extreme-heat-flux (approximately 1 kW/cm2) micro-coolers. In this study, a limited number of pool boiling experiments were performed using water and HFO-1233zd fluid, and the reliability of the CIO-based surfaces was evaluated. Critical heat flux (CHF) values in HFO-1233zd at 40 Degrees Celsius to 45 Degrees Celsius saturation temperatures and the corresponding saturation pressures were also measured. The CHF values with the refrigerant are significantly lower compared to those with water, but the refrigerant allows for a wider usable temperature range in the end application of the micro-coolers and is not limited to data centers with controlled ambient conditions. Reliability experiments with CIO surface samples - involving pool boiling with water on the CIO surfaces for approximately 48 hours and with HFO-1233zd for 144 hours - showed no structural degradation of the enhanced surface or any significant performance drop in heat transfer coefficients. The CIO surface samples in water were oxidized, most likely due to the presence of air in water and in the experimental vessel.

critical heat flux↗

Liquid metal boiling inception

An experimental study of the inception of boiling in potassium in forced convection is reported. The boiler consisted of a 0.19-inch inside diameter, niobium-1% zirconium boiler tube approximately six feet long. Heating was accomplished by direct electrical tube wall conduction. Experiments were performed with both all-liquid fill and two-phase fill startup sequences and with a range of flow rates, saturation temperatures, inert gas levels, and fill liquid temperatures. Superheat of the liquid above the equilibrium saturation temperature was observed in all the experiments. Incipient boiling liquid superheat ranged from a few degrees to several hundred. Comparisons of these data with other data and with several analytical treatments are presented.

Sabin, C. M.↗

Superconducting phase transitions in disordered NbTiN films

Suppression of superconductivity in disordered systems is a fundamental problem of condensed matter physics. Here we investigate superconducting niobium-titanium-nitride (Nb 1-x Ti x N) thin films grown by the atomic layer deposition (ALD) with slightly different growth process parameters. We observe a smooth crossover from the disorder-driven superconductor-normal metal transition (SMT) to the superconductor-insulator transition (SIT) via the intermediate Bose metal state detected by the low-temperature saturation of the temperature dependence of the sheet resistance. We demonstrate that the SIT via the intervening Bose metal state occurs if the sheet resistance of the film in the maximum, R max prior to the superconducting drop of R(T), exceeds R q = h/4e 2 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modeling Droplet Heat and Mass Transfer during Spray Bar Pressure Control of the Multipurpose Hydrogen Test Bed (MHTB) Tank in Normal Gravity

A CFD model for simulating pressure control in cryogenic storage tanks through the injection of a subcooled liquid into the ullage is presented and applied to the 1g MHTB spray bar cooling experiments. An Eulerian-Lagrangian approach is utilized to track the spray droplets and capture the interaction between the discrete droplets and the continuous ullage phase. The spray model is coupled with the VOF model by performing particle tracking in the ullage, removing particles from the ullage when they reach the interface, and then adding their contributions to the liquid. A new model for calculating the droplet-ullage heat and mass transfer is developed. In this model, a droplet is allowed to warm up to the saturation temperature corresponding to the ullage vapor pressure, after which it evaporates while remaining at the saturation temperature. The droplet model is validated against the results of the MHTB spray-bar cooling experiments with 50% and 90% tank fill ratios. The predictions of the present T-sat based model are compared with those of a previously developed kinetic-based droplet mass transfer model. The predictions of the two models regarding the evolving tank pressure and temperature distributions, as well as the droplets' trajectories and temperatures, are examined and compared in detail. Finally, the ullage pressure and local vapor and liquid temperature evolutions are validated against the corresponding data provided by the MHTB spray bar mixing experiment.

mass transfer↗

Capillary Pumped Loop 3 Flight Experiment Overview

The Capillary Pumped Loop 3 (CAPL 3) Experiment is a follow on to the CAPL 1 and CAPL 2 experiments which flew on STS-60 (2/94) and STS-69 (9/95), respectively. CAPL 3 is tentatively scheduled to fly on the Space Shuttle in late 2000 as part of the Hitchhiker Experiments Advancing Technology (HEAT) payload. The experiment is a joint Naval Research Laboratory (NRL)/Goddard Space Flight Center (GSFC) payload which will meet technology objectives for both the Department of Defense and NASA. The primary objective of CAPL 3 is to demonstrate in space a multiple evaporator capillary pumped loop system, capable of reliable start-up, reliable continuous operation, and at least 50% heat load sharing with hardware for a deployable radiator. CAPL 3 is a full scale CPL system with four parallel capillary evaporators. The loop also contains a capillary starter pump, 8 parallel direct condensation condensers with associated flow regulators, a back pressure regulator, a two-phase reservoir, and various headers and transport tubing. A variable conductance heat pipe is located between one of the evaporators and the experiment radiator to provide a cooling source for the demonstration of heat load sharing. The experiment has an operating power range of 100 W to approximately 1400 W. The experiment ammonia charge will cause it to transition to a fixed conductance mode of operation if the radiator usage reaches 85%. Ambient functional tests have been performed on the experiment. Tests performed included start-up, low power, power cycles, high power, heat load sharing, variable/fixed conductance transition, saturation temperature changes, and pressure primes while the system was operating. The majority of the testing was performed at an ammonia saturation temperature of 30C, but a few tests were done at temperatures above and below this. The testing was highly successful. Details of the tests performed and a discussion of the results will be given in the presentation.

Ottenstein, Laura↗

Modeling Self-Pressurization and Spray Bar Pressure Control of A Cryogenic Storage Tank in Normal Gravity

This paper presents computational fluid dynamics (CFD) models for simulating self-pressurization and spray-bar pressure control processes in a large-scale liquid hydrogen storage tank under normal gravity conditions. For self-pressurization, the model employs the kinetics-based Schrage equation alongside the volume-of-fluid (VOF) method to account for interfacial mass transfer. The CFD predictions of pressure and temperature are compared with experimental data from the Multipurpose Hydrogen Test Bed (MHTB) experiment, and the predicted interfacial mass transfer rates are also presented. A CFD model simulating pressure control using a spray bar has also been developed. An Eulerian-Lagrangian approach models the interactions between discrete droplets and the continuous ullage (vapor) phase. The spray model is coupled with the VOF method by tracking droplets in the ullage and removing them when they reach the liquid interface. The T-sat model calculates droplet-ullage heat and mass transfer, where droplets warm up to the saturation temperature corresponding to the ullage vapor pressure before evaporating while remaining at the saturation temperature. The evolution of tank pressure, vapor temperature, and liquid temperature predicted by the CFD model is validated against data from the MHTB spray-bar mixing experiment. Overall, the CFD models agree with experimental data, demonstrating their capability to simulate self-pressurization and pressure control processes in large-scale cryogenic storage tanks. These models can be valuable tools for designing and optimizing cryogenic fluid management systems in future applications.

Computational Fluid Dynamics↗