Search NASA⌕ Search

SEARCH · Search NASA

Results for “saturation temperature indicator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of a Flow Stabilization Algorithm Enabling Measurement of Low Oxygen Concentrations in Liquid Sodium

To enhance the automated control of the plugging meter (PM) and thereby enhance detection fidelity in ultralow oxygen environments [≤1 parts per million by weight (wppm)], a novel proportional derivative controller has been implemented with conventional PM hardware. This ramp sign stabilized flow (RSSF) controller manipulates the sign (heating or cooling direction) at a fixed rate, enabling precise temperature adjustment around the saturation temperature of the bulk sodium. This adjustment helps maintain flow stability in a partially formed sodium oxide plug, thus greatly reducing the temperature amplitude in the plugging cycle and promoting simple and accurate oxygen determinations in addition to an increased sampling rate. Rather than relying on the subjective nature of indexing the time when the flow rate changes due to the plugging or unplugging onset to the PM temperature, a running average of the correlated oxygen concentration with time over multiple plugging events can provide oxygen readings ranging from an absolute uncertainty of 500 wppb in real time to less than 50 wppb for a 24-h sampling window. Finally, the RSSF controller was tested at 508 ± 7 wppb with measured oxygen of 542 ± 179 wppb, further reducing the variance between the saturation temperature and the plugging temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of the operating characteristics of the SSME LOX turbopump pump-end bearing

A bearing/shaft model of the SSME LOX turbopump was developed using the SHABERTH bearing/shaft math modeling computer code. A previously developed bearing/shaft thermal model of the SSME LOX turbopump turbine and bearing was used in conjunction with SHABERTH to evaluate the thermomechanical operating characteristics of the LOX turbopump end bearings. Results show that for the two unmounted diametrical clearances evaluated (4.0 mils and 6.3 mils), the inboard pump end bearing supports about 81% of the isolator load for the small clearance and 77% of the isolator load for the larger clearance. Bearing clearance changes due to thermal effects were 40% for the 4.0 mil diametrical clearance case and 19% for the 6.3 mil clearance case evaluated. The thermal analysis included evaluation of bearing temperatures for a subcooled case and a saturated case. Results indicate that no drastic temperature change occurred between the two cases. Since the rolling element and race surfaces of the subcooled case were at temperatures sufficiently high enough to be vapor blanketed, exceeding saturation temperature at the bearing inlet did not increase surface temperatures greatly.

New, L. S.↗

Performance of Convection-Permitting and Convection-Parameterized Models in Reproducing the Extreme Precipitation Intensity Relationship with Surface Conditions

Here, this study investigates the warm-season extreme precipitation–temperature scaling relationship in CONUS404, a convection-permitting (4 km) Weather Research and Forecasting (WRF) Model simulation over the conterminous United States for the past four decades, and compares it with the WRF-Thermodynamic Global Warming (WRF-TGW) historical simulation at a coarser resolution (12 km) using parameterized convection. We also analyze the NCEP stage IV and NASA Integrated Multi-satellitE Retrievals for the Global Precipitation Measurement (IMERG) datasets as observational benchmarks. We examine how extreme precipitation intensity (EPI) varies with temperature and saturation deficit over representative regions based on hourly data. The stage IV and IMERG data show a similar pattern of EPI variation with temperature and saturation deficit, except that the EPI peak is lower in IMERG than in stage IV. Under dry and hot conditions, EPI decreases too rapidly with elevated saturation deficit in both CONUS404 and WRF-TGW compared to observations, but the performance of CONUS404 is superior to WRF-TGW. When the near-surface atmosphere is saturated or close to saturated, both CONUS404 and WRF-TGW produce higher peak values of EPI relative to the observational references; IMERG exhibits scaling rates close to the Clausius–Clapeyron (C–C) relationship, while CONUS404, WRF-TGW, and stage IV all demonstrate super-C–C scaling behaviors. Despite marked warming over the past four decades, in both CONUS404 and WRF-TGW, the scaling relationship between EPI and temperature in a saturated atmosphere remains stable and robust. This indicates a strong potential for the EPI–temperature scaling rate under saturation to be used as an emergent constraint in reducing uncertainties of future extreme precipitation projection.

Atmosphere↗

Assessing carbon storage capacity and saturation across six central US grasslands using data–model integration

Abstract. Future global changes will impact carbon (C) fluxes and pools in most terrestrial ecosystems and the feedback of terrestrial carbon cycling to atmospheric CO2. Determining the vulnerability of C in ecosystems to future environmental change is thus vital for targeted land management and policy. The C capacity of an ecosystem is a function of its C inputs (e.g., net primary productivity – NPP) and how long C remains in the system before being respired back to the atmosphere. The proportion of C capacity currently stored by an ecosystem (i.e., its C saturation) provides information about the potential for long-term C pools to be altered by environmental and land management regimes. We estimated C capacity, C saturation, NPP, and ecosystem C residence time in six US grasslands spanning temperature and precipitation gradients by integrating high temporal resolution C pool and flux data with a process-based C model. As expected, NPP across grasslands was strongly correlated with mean annual precipitation (MAP), yet C residence time was not related to MAP or mean annual temperature (MAT). We link soil temperature, soil moisture, and inherent C turnover rates (potentially due to microbial function and tissue quality) as determinants of carbon residence time. Overall, we found that intermediates between extremes in moisture and temperature had low C saturation, indicating that C in these grasslands may trend upwards and be buffered against global change impacts. Hot and dry grasslands had greatest C saturation due to both small C inputs through NPP and high C turnover rates during soil moisture conditions favorable for microbial activity. Additionally, leaching of soil C during monsoon events may lead to C loss. C saturation was also high in tallgrass prairie due to frequent fire that reduced inputs of aboveground plant material. Accordingly, we suggest that both hot, dry ecosystems and those frequently disturbed should be subject to careful land management and policy decisions to prevent losses of C stored in these systems.

58 GEOSCIENCES↗

A study of planetary meteorology

Inversion techniques are applied to the few earth based observations of the Jovian emission spectrum to obtain directly the profiles of atmospheric temperature and ammonia abundance. The temperature profile is characterized by a definite tropopause region with a temperature of about 115K and a stratospheric region in which the temperature slowly increases with altitude. The derived ammonia profile indicates the presence of a saturated ammonia layer with a base temperature of approximately 14OK. The concept is described deducing the temperature and constituent profile of a planetary atmosphere from orbiter measurements of the planet's IR limb radiance profile. Analysis of the weighting functions for the Martian atmosphere indicates that a limb radiance profile in the 15 micron CO2 band can be used to determine the Martian atmospheric temperature profile from 20 to 60 km.

Ohring, G.↗

Final Technical Report Wireless Microsensors System for Monitoring Deep Subsurface Operations

This final technical report describes the main findings of the project Wireless Microsensors System for Monitoring Deep Subsurface Operations (FE0031850). The project was part of the U.S. Department of Energy National Energy Technology Laboratory FOA 1998 program to develop new sensor systems for direct observation of parameters associated with CO2 injection and to provide data collection without being disruptive to operations. The overall DOE program was aimed at developing and validating innovative transformational sensor systems, amenable for integration with autonomous intelligent monitoring systems, that are capable of being deployed within the casing annulus and do not have casing perforation or wires/cables in the annulus for installation, power supply, or data transmission needs. Project accomplishments included 1) design and fabrication of a wireless downhole sensor system to monitor parameters for CO2 storage, 2) field testing of the sensor system in two legacy oil & gas wells, and 3) development of an analysis approach that validates the measurements and demonstrates the application of the technology to depict CO2 movement in the subsurface. The project leveraged new sensor technologies along with specialized wellbore telemetry, deployment, and analysis methods designed to address the challenges and risks related to CO2 storage in the subsurface. Results from field testing were a mixture of successes and challenges. The temperature sensor rings, installation procedures in legacy oil & gas wells, wireless powering demonstration, automated data collection, and material compatibility were successful. The wireless data transfer through cement to the wellhead via the sensor relays was not functional beyond the first relay. Consequently, work in the last year of the project included some additional testing of data transmission through different materials along with modeling and analysis of field data for CO2 monitoring applications. This work suggested there are options like polymer cements and open hole annuli that may allow point-to-point transmission along the borehole. The techno-economic analysis suggests that the sensor system is ~40% less expensive than fiber optic distributed temperature system. Modeling of CO2 storage applications suggests temperature can provide an indicator of CO2 saturation but would be best combined with pressure sensors.

47 OTHER INSTRUMENTATION↗

The Distribution, Composition, and Particle Properties of Mars Mesospheric Aerosols: an Analysis of CRISM Visible/near-IR Limb Spectra with Context from Near-Coincident MCS and MARCI Observations

The Compact Reconnaissance Imaging Spectral Mapper (CRISM) onboard the Mars Reconnaissance Orbiter (MRO) obtains pole-to-pole observations (i.e., full MRO orbits) of vertical profiles for visible/near-IR spectra (λ=0.4–4.0 μm), which are ideally suited to identifying the composition and particle sizes of Mars ice and dust aerosols over 50–100 km altitudes in the Mars mesosphere. Within the coverage limitations of the CRISM limb data set, a distinct compositional dichotomy is found in Mars mesospheric ice aerosols. CO2 ice clouds appear during the aphelion period of Mars orbit (Solar Longitudes, Ls∼0–160°) at low latitudes (∼20S–10N) over specific longitude regions (Meridiani, Valles Marineris) and at typical altitudes of 55–75 km. Apart from faint water ice hazes below 55 km, mesospheric H2O ice clouds are primarily restricted to the perihelion orbital range (Ls∼160 – 350°) at northern and southern mid-to-low latitudes with less apparent longitudinal dependences. Mars mesospheric CO2 clouds are presented in CRISM spectra with a surprisingly large range of particle sizes (cross section weighted radii, Reff=0.3 to 2.2 μm). The smaller particle sizes (Reff ≤1 μm) appear concentrated near the spatial (latitude and altitude) boundaries of their global occurrences. CRISM spectra of mesospheric CO2 clouds also show evidence of iridescence, indicating very narrow particle size distributions (effective variance, Veff∼0.03) and so very abrupt CO2 cloud nucleation. Furthermore, these clouds are sometimes accompanied by altitude coincident peaks in 1.27 μm O2 dayglow, which indicates very dry, cold regions of formation. Mesospheric water ice clouds generally exhibit small particle sizes (Reff=0.1–0.3 μm), although larger particle sizes (Reff=0.4–0.7 μm) appear infrequently. On average, water ice cloud particle sizes decrease with altitude over 50–80 km in the perihelion mesosphere. Water ice mass appears similar in clouds over a large range of observed cloud particle sizes, with particle number densities increasing to ∼10 cm−3 for Reff=0.2 μm. Near coincident Mars Climate Sounder (MCS) temperature and aerosol profile measurements for a subset of CRISM mesospheric aerosol measurements indicate near saturation (H2O and CO2) conditions for ice clouds and distinct mesospheric temperature increases associated with mesospheric dust loading. Dayside (3 pm) mesospheric CO2 clouds with larger particle sizes (Reff ≥0.5 μm) scatter surface infrared emission in MCS limb infrared radiances, as well as solar irradiance in the MCS solar band channel. Scattering of surface infrared emission is most strikingly presented in nighttime (3 am) MCS observations at 55–60 km altitudes, indicating extensive mesospheric nighttime CO2 clouds with considerably larger particle sizes (Reff∼7 μm). Mesospheric CO2 ice clouds present cirrus-like waveforms over extensive latitude and longitude regions (10°×10°), as revealed in coincident Mars Color Imager (MARCI) nadir imaging. Solar tides, gravity waves, and the large orbital variation of the extended thermal structure of the Mars atmosphere influence all of these behaviors. Mesospheric dust aerosols appear infrequently over the non-global (planet encircling) dust storm era of the CRISM limb data set (2009–2016), and exhibit smaller particle sizes (Reff=0.2–0.7 μm) relative to dust in the lower atmosphere. One isolated case of an aphelion (Ls=96°) mesospheric dust layer with large dust particle sizes (Reff ∼2 μm) over Syria Planum may reflect high altitude, non-local transport of dust over elevated regions.

Clancy, Todd R.↗

The distribution, composition, and particle properties of Mars mesospheric aerosols: An analysis of CRISM visible/near-IR limb spectra with context from near-coincident MCS and MARCI observations

The Compact Reconnaissance Imaging Spectral Mapper (CRISM) onboard the Mars Reconnaissance Orbiter (MRO) obtains pole-to-pole observations (i.e., full MRO orbits) of vertical profiles for visible/near-IR spectra (λ= 0.4–4.0 μm), which are ideally suited to identifying the composition and particle sizes of Mars ice and dust aerosols over 50–100 km altitudes in the Mars mesosphere. Within the coverage limitations of the CRISM limb data set, a distinct compositional dichotomy is found in Mars mesospheric ice aerosols. CO2 ice clouds appear during the aphelion period of Mars orbit (Solar Longitudes, L(s )∼ 0–160°) at low latitudes (∼20S–10N) over specific longitude regions (Meridiani, Valles Marineris) and at typical altitudes of 55–75 km. Apart from faint water ice hazes below 55 km, mesospheric H2O ice clouds are primarily restricted to the perihelion orbital range (L(s)∼160 – 350°) at northern and southern mid-to-low latitudes with less apparent longitudinal dependences. Mars mesospheric CO2 clouds are presented in CRISM spectra with a surprisingly large range of particle sizes (cross section weighted radii, R(eff) = 0.3 to 2.2 μm). The smaller particle sizes (R(eff) ≤1 μm) appear concentrated near the spatial (latitude and altitude) boundaries of their global occurrences. CRISM spectra of mesospheric CO2 clouds also show evidence of iridescence, indicating very narrow particle size distributions (effective variance, V(eff) ∼ 0.03) and so very abrupt CO2 cloud nucleation. Furthermore, these clouds are sometimes accompanied by altitude coincident peaks in 1.27 μm O2 dayglow, which indicates very dry, cold regions of formation. Mesospheric water ice clouds generally exhibit small particle sizes (R(eff) = 0.1–0.3 μm), although larger particle sizes (R(eff) = 0.4–0.7 μm) appear infrequently. On average, water ice cloud particle sizes decrease with altitude over 50–80 km in the perihelion mesosphere. Water ice mass appears similar in clouds over a large range of observed cloud particle sizes, with particle number densities increasing to ∼10 per cu. cm for R(eff) = 0.2 μm. Near coincident Mars Climate Sounder (MCS) temperature and aerosol profile measurements for a subset of CRISM mesospheric aerosol measurements indicate near saturation (H2O and CO2) conditions for ice clouds and distinct mesospheric temperature increases associated with mesospheric dust loading. Dayside (3 pm) mesospheric CO2 clouds with larger particle sizes (R(eff) ≥0.5 μm) scatter surface infrared emission in MCS limb infrared radiances, as well as solar irradiance in the MCS solar band channel. Scattering of surface infrared emission is most strikingly presented in nighttime (3 am) MCS observations at 55–60 km altitudes, indicating extensive mesospheric nighttime CO2 clouds with considerably larger particle sizes (R(eff)∼7 μm). Mesospheric CO2 ice clouds present cirrus-like waveforms over extensive latitude and longitude regions (10°×10°), as revealed in coincident Mars Color Imager (MARCI) nadir imaging. Solar tides, gravity waves, and the large orbital variation of the extended thermal structure of the Mars atmosphere influence all of these behaviors. Mesospheric dust aerosols appear infrequently over the non-global (planet encircling) dust storm era of the CRISM limb data set (2009–2016), and exhibit smaller particle sizes (R(eff) = 0.2–0.7 μm) relative to dust in the lower atmosphere. One isolated case of an aphelion (L(s) = 96°) mesospheric dust layer with large dust particle sizes (R(eff) ∼2 μm) over Syria Planum may reflect high altitude, non-local transport of dust over elevated regions.

R. Todd Clancy↗

Development and Utility of a Four-Channel Scanner for Wildland Fire Research and Applications

The Airborne Infrared Disaster Assessment System (AIRDAS) is a four-channel scanner designed and built at NASA-Ames for the specific task of supporting research and applications on fire impacts on terrestrial and atmospheric processes and also of serving as a vital instrument in the assessment of natural and man-induced disasters. The system has been flown on numerous airframes including the Navajo, King-Air, C0130, and Lear Jet 310 and a 206. The system includes a configuration composed of a 386 PC computer workstation, a non-linear detector amplifier, a sixteen-bit digitizer, dichroic filters, and Exabyte 8500 5Gb Tape output, VHS tape output, a Rockwell GPS and a 2-axis gyro. The AIRDAS system collects digital data in four wavelength regions, which can be filtered: band 1 (0.61-0.68 microns), band 2 (1.57-1.7 microns), band 3 (3.6-5.5 microns), and band 4 (5.5-13.0 microns), an FOV of 108 degrees, an IFOV of 2.62 mrads, and a digitized swath width of 720 pixels. The inclusion of the non-linear detector amplifier allows for the accurate measurement of emitted temperature from fires and hot spots. Lab testing of the scanner has indicated temperature assessments of 800 C without detector saturation. This has advantages over previous systems which were designed for thermal measurement of earth background temperatures, and were ill-equipped for accurate determination of high intensity conditions. The scanner has been flown successfully on data collection missions since 1992 in the western US as well as Brazil. These and other research and applications responses will be presented along with an assessment of future directions with the system.a

Ambrosia, Vincent G.↗

Electronic band structure and magnetism of CoFeV 0.5 Mn 0.5 Si

Half-metallic Heusler alloys have attracted significant attention due to their potential application in spin-transport-based devices. We have synthesized one such alloy, CoFeV 0.5 Mn 0.5 Si, using arc melting and high-vacuum annealing at 600 °C for 24 hours. First principles calculation indicates that CoFeV 0.5 Mn 0.5 Si shows a nearly half-metallic band structure with a degree of spin polarization of about 93%. In addition, this value can be enhanced by the application of tensile strain. The room temperature x-ray diffraction patterns are indexed with the cubic crystal structure without secondary phases. The annealed sample shows ferromagnetic order with the Curie temperature well above room temperature ( T c = 657 K) and a saturation magnetization of about 92 emu/g. Our results indicate that CoFeV 0.5 Mn 0.5 Si has a potential for room temperature spin-transport-based devices.

36 MATERIALS SCIENCE↗

Physical Processes Controlling the Distribution of Relative Humidity in the Tropical Tropopause Layer over the Pacific

The distribution of relative humidity with respect to ice (RHI) in the Boreal wintertime Tropical Tropopause Layer (TTL - about 14-19 km) over the Pacific is examined with the extensive dataset of measurements from the NASA Airborne Tropical TRopopause EXperiment (ATTREX). Multiple deployments of the Global Hawk during ATTREX provided hundreds of vertical profiles spanning the Pacific with accurate measurements of temperature, pressure, water vapor concentration, ozone concentration, and cloud properties. We also compare the measured RHI distributions with results from a transport and microphysical model driven by meteorological analysis fields. Notable features in the distribution of RHI versus temperature and longitude include (1) the common occurrence of RHI values near ice saturation over the western Pacific in the lower TTL (temperatures greater than 200 K) and in airmasses with low ozone concentrations indicating recent detrainment from deep convection; (2) low RHI values in the lower TTL over the eastern Pacific where deep convection is infrequent; (3) RHI values following a constant H2O mixing ratio in the upper TTL (temperatures below about 195 degrees Kelvin), particularly for samples with ozone mixing ratios greater than about 50-100 parts-per-billion-volume indicating mixtures of tropospheric and stratospheric air, and (4) RHI values typically near ice saturation in the coldest airmasses sampled (temperatures less than about 190 degrees Kelvin). We find that the typically saturated air in the lower TTL over the western Pacific is largely driven by the frequent occurrence of deep convection in this region. The nearly-constant water vapor mixing ratios in the upper TTL result from the combination of slow ascent (resulting in long residence times) and wave-driven temperature variability on a range of time scales (resulting in most air parcels having experienced low temperature and dehydration).

ozone↗

On the relationship between precipitation extreme and local temperature over eastern China based on convection permitting simulations: roles of different moisture processes and precipitation types

The Clausius–Clapeyron (CC) scaling, which indicates a roughly 7% increase in saturated water vapor per 1 °C increase in temperature, can serve as a strong constraint linking the intensity of precipitation extremes and local temperature. However, the relationship between precipitation extreme and local temperature (referred to as the PE-T relationship) does not always follow the CC scaling and is highly dependent on climate regimes. In this study, we investigated the impacts of different moisture processes and precipitation types on the PE-T relationship over eastern China during the summertime based on convection-permitting model simulations. Consistent with observations, the simulated intensity of precipitation extremes increases with temperature at a rate close to CC (double-CC) scaling below (above) 20 °C. When the temperature exceeds 25 °C, precipitation intensity starts to drop. Precipitation extremes are mainly contributed by the stratiform, MCS (i.e., mesoscale convective system) convective, and non-MCS convective precipitation at low (< 20 °C), medium (20–25 °C), and high (> 25 °C) temperatures, respectively, suggesting that the double-CC scaling occurs when convective types become dominant, while the negative scaling at high temperatures is attributed to the reduced horizontal scale of convection. Corresponding to the reduced intensity of precipitation at high temperatures, there are stronger divergence and subsidence in the low-level atmosphere, which is probably caused by the net cooling associated with the enhanced melting and evaporation of falling hydrometeors due to the lower relative humidity in the low-level atmosphere. Overall, our findings contribute to a deeper understanding of the temperature dependence of precipitation extremes in eastern China.

54 ENVIRONMENTAL SCIENCES↗

Mechanical Property Evaluation of CuNb Composites Manufactured with High-Pressure Torsion

Copper is under consideration as the optimum material for both high heat flux applications and high pulsed magnets. One challenge is that copper has low strength which is problematic to deployment in these applications. One solution is to alloy copper with BCC elements to improve its mechanical properties. However, the limited solubility of the BCC elements in copper requires high deformation processes to be used in order to manufacture these 3D composites. Here, high energy ball milling combined with high pressure torsion was used to manufacture 3D Cu-Nb composites. After the consolidation the mechanical properties of the composites were measured using micro- and nanohardness testing at room and elevated temperature. The results indicated that after 10 turns during the high-pressure torsion consolidation, the mechanical properties of the composites were completely saturated displaying uniform properties across the manufactured disk. Performing the high pressure torsion at temperature further improved consolidation of the disk. The high temperature nanoindentation also indicated a change in the deformation mechanism between 200 and 500 ºC.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Growth and characterization of La 0.67 Sr 0.33 MnO 3 /YBa 2 Cu 3 O 7- δ bilayers

Understanding the interplay of ferromagnets and superconductors requires high quality interfaces. To this end, we have fabricated heterostructures of the cuprate superconductor YBa2Cu3O7-δ (YBCO) with the metallic ferromagnet La0.67Sr0.33MnO3 (LSMO) via pulsed laser deposition on SrTiO3 (STO) (001) and (LaAlO3)0.3(Sr2TaAlO6)0.7 (LSAT) (001) substrates. By varying the YBCO thickness from 1.7-13.6 nm while keeping the LSMO thickness at 12 nm, we have studied the interplay between ferromagnetism and superconductivity in the in-plane transport and magnetic properties of the bilayers. X-ray reflectivity data indicate the presence of a 2-3 nm thick interfacial layer between the LSMO and YBCO layers in all heterostructures. In-plane transport measurements exhibit suppression of the superconducting transition temperature from bulk YBCO values. Magnetometry measurements indicate high LSMO saturation magnetization values for samples grown on STO substrates and even higher (bulk-like) magnetization for bilayers grown on LSAT substrates. Together these results indicate that the interdiffused layer is largely attributed to a modified YBCO layer.

36 MATERIALS SCIENCE↗

Microscopic study of the impurity effect in the kagome superconductor La⁢(Ru 1–x ⁢Fe x ) 3 ⁢Si 2

Here, we report on the effect of magnetic impurities on the microscopic superconducting (SC) properties of the kagome-lattice superconductor La⁢(Ru 1–x Fe x ) 3 ⁢Si 2 using muon spin relaxation/rotation. A strong suppression of the superconducting critical temperature T c , the SC volume fraction, and the superfluid density was observed. We further find a correlation between the superfluid density and T c which is considered a hallmark feature of unconventional superconductivity. Most remarkably, measurements of the temperature-dependent magnetic penetration depth λ reveal a change in the low-temperature behavior from exponential saturation to a linear increase, which indicates that Fe doping introduces nodes in the superconducting gap structure at concentrations as low as x=0.015. Our results point to a rare example of unconventional superconductivity in the correlated kagome lattice and accessible tunability of the superconducting gap structure, offering new insights into the microscopic mechanisms involved in superconducting order.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Technique for direct measurement of magnetic entropy of solids: Results for dysprosium titanium oxide

A measurement technique was devised which permits direct observation of the magnetic entropy of solids as a function of applied magnetic field. Measurements were made of the magnetic entropy, in the temperature range 2 to 20 K, of polycrystalline samples of dysprosium titanium oxide (Dy2Ti2O7) to determine its suitability for use as the working substance of a magnetic refrigerator. Magnetization measurements were also made at 4.2 K and below to provide additional information on the nature of the compound. The measurements indicated that crystalline electric fields perturbed the ground state of the dysprosium ions, removed the 16-fold degeneracy predicted by Hund's rules, and left only a twofold degeneracy in its place. A positive, temperature independent contribution to the magnetization was observed in the saturation region, which indicated that the doublet ground-state wave function was perturbed by a nearby unpopulated upper energy level.

Flood, D. J.↗

Stable Stratification for Solar Ponds

Stable density gradient forms in pond saturated with disodium phosphate (DSP). Volume of DSP saturated water tends to develop temperature and density layers. Since tests indicate thermal and density gradients remain in equilibrium at heat removal rates of 60 percent or more of heat input rate, pond containing DSP would be suitable for collecting solar energy and transferring it to heat exchanger for practical use.

Mehta, G. D.↗

Formation of a Tropopause Cirrus Layer Observed over Florida during CRYSTAL-FACE

On July 13, 2002 a widespread, subvisible tropopause cirrus layer occurred over the Florida region. This cloud was observed in great detail with the NASA Cirrus Regional Study of Tropical Anvils and Cirrus Layers-Florida Area Cirrus Experiment (CRYSTAL-FACE) instrumentation, including in situ measurements with the WB-57 aircraft. In this paper, we use the 13 July cloud as a case study to evaluate the physical processes controlling the formation and evolution of tropopause cirrus layers. Microphysics measurements indicate that ice crystal diameters in the cloud layer ranged from about 7 to 50 microns, and the peak number mode was about 10-25 microns. In situ water vapor and temperature measurements in the cloud indicated supersaturation with respect to ice throughout, with ice saturation ratios as large as 1.8. Even when the ice surface area density was as high as about 500 sq microns/cu cm, ice supersaturations of 20-30% were observed. Trajectory analysis shows that the air sampled near the tropopause on this day generally came from the north and cooled considerably during the previous few days. Examination of infrared satellite imagery along air parcel back trajectories from the WB-57 flight track indicates that the tropopause cloud layer formation was, in general, not simply left over ice from recently generated anvil cirrus. Simulations of cloud formation using time-height curtains of temperature along the trajectory paths show that the cloud could have formed in situ near the tropopause as the air was advected into the south Florida region and cooled to unusually low temperatures. If we assume a high threshold for ice nucleation via homogeneous freezing of aqueous sulfate aerosols, the model reproduces the observed cloud structure, ice crystal size distributions, and ice supersaturation statistics. Inclusion of observed gravity wave temperature perturbations in the simulations is essential to reproduce the observed cloud properties. Without waves, crystal number densities are too low, crystal sizes are too large, and the crystals fall out too fast, leaving very little cloud persisting at the end of the simulations. In the cloud simulations, coincidence of high supersaturations and high surface areas can be produced by either recent nucleation or sedimentation of crystals into supersaturated layers. The agreement between model results and observed supersaturations is improved somewhat if we assume that the steady state relative humidity within cirrus at T<200 K is enhanced by about 30%. The WB-57 measurements and the model results suggest that the cloud layer irreversibly dehydrated air near the tropopause.

Jensen, Eric↗