Search NASA⌕ Search

SEARCH · Search NASA

Results for “scan_rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Scan rate converter for tape recording and playback of TV pictures

Magnetic tape recording and playback equipment converts television pictures, both black and white and color, from one scan rate to another. The equipment indexes color picture frames for retrieval electronically and can be used as a document storage and retrieval medium that is compatible with hard-copy printout machines.

Holt, N. I.↗

Wide-field reflective scanning optical systems

Catoptric optical scanning system provides relatively fast line-scan rate for two-dimensional coverage. Rapid scan rates require low focal ratios between components and smallest possible masses. System is relatively free from monochromatic defects and chromatic aberrations.

Abel, I. R.↗

Ultrasonic simulation of MSBLS multipath fading for orbiter landing configuration

The on-shuttle antenna pattern of the MSBLS receiver, and the azimuth and elevation beamwidths were simulated by their corresponding ultrasonic transducer beams. The scanning rate for the azimuth and elevation beams was 1.75 degrees/second. The results were adjusted for full-scale maximum sinusoidal scan rates of 691 and 377 deg/sec for AZ and EL respectively. The rain drops were simulated by air bubbles, with a similar size distribution, in water. The rain volume was created along a part of the propagation path, and not on the runway, because it was found difficult to avoid an accumulation of bubbles on the runway surface and surroundings simulated by the model surface. Multipath fading from the ground, and its possible degrading effect on the orbiter received beam shape and the associated landing guidance parameters is discussed.

Hayre, H. S.↗

New electron microscope employs new video display technique

Video display system for a scanning electron microscope provides slow scanning rates, a self-generated color gradient technique, and allows leisurely viewing of several hours. It also enables the viewing of areas where selected energy regions contribute relatively few electrons, and the changing of specimen position and magnification without adjustments.

Brookshier, W. K.↗

Multiple target tracking and target attitude determination with a scanning laser radar

A scanning laser radar that can acquire and track single or multiple targets has recently been developed. Scan patterns have been designed for acquisition and tracking of one or more targets using a narrow laser beam. A synchronously scanned transmitter-receiver is used to acquire and track targets anywhere in a 376 x 376 element raster covering a 30 x 30 deg field. All scan patterns are electronically programmed, and the system automatically acquires and tracks the target or targets without the aid of an operator. The maximum tracking rate is 1.0 deg/sec (10.0 deg/sec) when used with a 1 kHz (10 kHz) scan rate. The estimated free space range against passive cooperative targets (corner cube reflectors) is 30 nautical miles. The laser radar has an accuracy of 10 cm (range) and 0.05 deg (angle). The developmental system is relatively small (1.5 cu ft), lightweight (60 lbs) and low-power-consuming (60 W).

Flom, T.↗

The Viking Mars lander camera

The 7.3 kg cameras for the 1976 Viking Mars expedition feature an array of 12 silicon photodiodes, including six spectral bands for color and near-infrared imaging with an angular resolution of 0.12 deg and four focus steps for broadband imaging, with an improved angular resolution of 0.04 deg. The field of view in elevation ranges from 40 deg above to 60 deg below the horizon, and in azimuth ranges to 342.5 deg. The cameras are mounted 0.8 m apart to provide a stereo view of the area accessible to a surface sampler for biological and chemical investigations. The scanning rates are synchronized to the lander data transmission rates of 16000 bits per sec to the Viking orbiters as relay stations and 250 bits per sec directly to earth. However, image data can also be stored on a lander tape recorder. About 10 million bits of image data will be transmitted during most days of the 60-day-long mission planned for each lander.

Huck, F. O.↗

Electrical characterization of GaAs single crystal in direct support of M555 flight experiment

The exploration of several nondestructive methods of electrical characterization of semiconductor single crystals was carried out during the period ending May 1974. Two methods of obtaining the microwave skin depth, one for the mapping flat surfaces and the other for analyzing the whole surface of small single crystal wafers, were developed to the stage of working laboratory procedures. The preliminary 35 GHz data characterizing the two types of space-related single crystal surfaces, flat slices of gallium arsenide and small wafers of germanium selenide, are discussed. A third method of nondestructive mapping of donor impurity density in semiconductor surfaces by scanning with a light beam was developed for GaAs; its testing indicates reasonable precision at reasonable scan rates for GaAs surfaces at room temperature.

Castle, J. G.↗

Electrical characterization of GaAs single crystal in direct support of M555 flight experiment

An exploration of several nondestructive methods of electrical characterization of semiconductor single crystals was carried out. Two methods of obtaining the microwave skin depth, one for mapping flat surfaces and the other for analyzing the whole surface of small single crystal wafers, were developed to the stage of working laboratory procedures. The preliminary 35 GHz data characterizing the two types of space related single crystal surfaces, flat slices of gallium arsenide and small wafers of germanium selenide, are discussed. A third method of nondestructive mapping of donor impurity density in semiconductor surfaces by scanning with a light beam was developed for GaAs; its testing indicates reasonable precision at reasonable scan rates for GaAs surfaces at room temperature.

Castle, J. G.↗

A microprocessor controlled pressure scanning system

A microprocessor-based controller and data logger for pressure scanning systems is described. The microcomputer positions and manages data from as many as four 48-port electro-mechanical pressure scanners. The maximum scanning rate is 80 pressure measurements per second (20 ports per second on each of four scanners). The system features on-line calibration, position-directed data storage, and once-per-scan display in engineering units of data from a selected port. The system is designed to be interfaced to a facility computer through a shared memory. System hardware and software are described. Factors affecting measurement error in this type of system are also discussed.

Anderson, R. C.↗

A coherent light scanner for optical processing of large format transparencies

A laser scanner is discussed in which the scanning beam is random-access addressable and perpendicular to the image input plane and the irradiance of the scanned beam is controlled so that a constant average irradiance is maintained after passage through the image plane. The scanner's optical system and design are described, and its performance is evaluated. It is noted that with this scanner, data in the form of large-format transparencies can be processed without the expense, space, maintenance, and precautions attendant to the operation of a high-power laser with large-aperture collimating optics. It is shown that the scanned format as well as the diameter of the scanning beam may be increased by simple design modifications and that higher scan rates can be achieved at the expense of resolution by employing acousto-optic deflectors with different relay optics.

Callen, W. R.↗

Passive microwave mapping of ice thickness

Basic calculations are presented for evaluating the feasibility of a scanning microwave radiometer system for mapping the thickness of lake ice. An analytical model for the apparent brightness temperature as a function of ice thickness has been developed, and elaborated to include such variables as galactic and atmospheric noise, aspect angle, polarization, temperature gradient in the ice, the presence of transition layers such as snow, slush, and water, increased loss due to air inclusions in the ice layer, and the presence of multiple ice thicknesses within the antenna footprint. It was found that brightness temperature measurements at six or seven frequencies in the range of 0.4 to 0.7 GHz were required to obtain unambiquous thickness estimates. A number of data processing methods were examined. The effects of antenna beamwidth, scanning rate, receiver bandwidth, noise figure, and integration time were studied.

Apinis, J. J.↗

A photon counting array photometer using an intensified charge coupled device

An array photometer which uses an intensified charge coupled device was developed. This system, the University of Maryland Array Photometer (UMAP), has the ability to discriminate single photoelectron events in real time at a 4 Megahertz rate. The photosensor uses an S-20 photocathode and a Fairchild CCD202 with a 100 by 100 array of separate individual channels. The overall system has demonstrated a noise level which permits single photoelectron discrimination, a scan rate of 400 frames per second, a very linear response, and very low lag. The UMAP system has a very large dynamic range exceeding 10,000 in the photon counting mode. A special technique to extend the dynamic range to 1,000,000 was described. The performance parameters of this system, both in the laboratory and on the telescope were cited. Data from these observations were discussed to illustrate the system sensitivity, which is basically limited by the pixel size in the array, rather than the electrooptics.

Currie, D. G.↗

A photon counting array photometer

The operation and performance of an array photometer with the ability to discriminate on single photoelectrons are discussed. The system consists of a 100 by 100 array of channels which count single photoelectrons. The photosensor is an Intensified Charge Coupled Device using a Fairchild CCD201 which was fabricated by the Electronic Vision Company. This system has demonstrated a noise level which permits single photoelectron discrimination, high scan rate (400 frames/sec), and low lag. The UMAP system has been successfully operated in the photon counting mode on a 36-inch telescope and on a 48-inch telescope. Data from these observations illustrate the system sensitivity and the spacial resolution which is better defined by the size of an individual pixel element on the CCD.

Currie, D. G.↗

A microprocessor controlled pressure scanning system

A microprocessor-based controller and data logger for pressure scanning systems is described. The microcomputer positions and manages data from as many as four 48-port electro-mechanical pressure scanners. The maximum scanning rate is 80 pressure measurements per second (20 ports per second on each of four scanners). The system features on-line calibration, position-directed data storage, and once-per-scan display in engineering units of data from a selected port. The system is designed to be interfaced to a facility computer through a shared memory. System hardware and software are described. Factors affecting measurement error in this type of system are also discussed.

Anderson, R. C.↗

Space Shuttle Proximity Operation Sensor Study

The performance of the Kuband radar was analyzed in detail, and the performance was updated and summarized. In so doing, two different radar design philosophies were described, and the corresponding differences in losses were enumerated. The resulting design margins were determined for both design philosophies and for both the designated and nondesignated range modes of operation. In some cases, the design margin was about zero, and in other cases it was significantly less than zero. With the point of view described above, the recommended solution is to allow more scan time but at the present scan rate. With no other changes in the present configuration, the radar met design detection specifications for all design philosophies at a range of 11.3 nautical miles.

Weber, C. L.↗

Conical scan tracking system employing a large antenna

A conical scan tracking system for tracking spacecraft and distant radio sources is described. The system detects small sinusoidal modulation in received power from a source that is off target with a frequency equal to a very low scan rate, an amplitude proportional to angular deviation of the source from the target, and a phase directly related to the direction the source is off target. The sinusoid is digitally correlated with inphase and out-of-phase scan sinusoids to obtain azimuth/elevation and hour angle/declination signals which are digitally integrated over exactly one scan period to obtain correction signals for an antenna pointing subsystem.

Ohlson, J. E.↗