Search NASA⌕ Search

SEARCH · Search NASA

Results for “scanning electron microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Resolving the Electron Plume within a Scanning Electron Microscope

Scanning electron microscopy (SEM), a century-old technique, is today a ubiquitous method of imaging the surface of nanostructures. However, most SEM detectors simply count the number of secondary electrons from a material of interest, and thereby overlook the rich material information contained within them. Here, by simple modifications to a standard SEM tool, we resolve the momentum and energy information on secondary electrons by directly imaging the electron plume generated by the electron beam of the SEM. Leveraging these spectroscopic imaging capabilities, our technique is able to image lateral electric fields across a prototypical silicon p–n junctions and to distinguish differently doped regions, even when buried beyond depths typically accessible by SEM. Intriguingly, the subsurface sensitivity of this technique reveals unexpectedly strong surface band bending within nominally passivated semiconductor structures, providing useful insights for complex layered component designs, in which interfacial dynamics dictate device operation. Further, these capabilities for noninvasive, multimodal probing of complicated electronic components are crucial in today’s electronic manufacturing but is largely inaccessible even with sophisticated techniques. These results show that seemingly simple SEM can be extended to probe complex and useful material properties.

36 MATERIALS SCIENCE↗

Development of an in situ ion irradiation scanning electron microscope

An in situ ion irradiation scanning electron microscope (I 3 SEM) has been developed, installed, and integrated into the Ion Beam Laboratory at Sandia National Laboratories. The I 3 SEM facility combines a field emission, variable pressure, scanning electron microscope, a 6 MV tandem accelerator, high flux low energy ion source, an 808 nm-wavelength laser, and multiple stages to control the thermal and mechanical state of the sample observed. The facility advances real-time understanding of materials evolution under combined environments at the mesoscale. As highlighted in multiple examples, this unique combination of tools is optimized for studying mesoscale material response in overlapping extreme environments, allowing for simultaneous ion irradiation, implantation, laser bombardment, conductive heating, cooling, and mechanical deformation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantification of grain boundary effects on the geometrically necessary dislocation density evolution and strain hardening of polycrystalline Mg 4Al using in situ tensile testing in scanning electron microscope and HR-EBSD

In situ tensile testing in a scanning electron microscope (SEM) in conjunction with high-resolution electron backscatter diffraction (HR-EBSD) under load was used to characterize the evolution of geometrically necessary dislocation (GND) densities at individual grain boundaries as a function of applied strain in a polycrystalline Mg—4Al alloy. The increase in GND density was investigated at plastic strains of 0 %, 0.6 %, 2.2 %, 3.3 % from the area including 76 grains and correlated with (i) geometric compatibility between slip systems across grain boundaries, and (ii) plastic incompatibility. We develop expressions for the grain boundary GND density evolution as a function of plastic strain and plastic incompatibility, from which uniaxial tensile stress-strain response of polycrystalline Mg—4Al are computed and compared with experimental measurement. The findings in this study contribute to understanding the mechanisms governing the strain hardening response of single-phase polycrystalline alloys and more reliable prediction of mechanical behaviors in diverse microstructures.

Geometrically necessary dislocations↗

Preparing Lamellae from Vitreous Biological Samples using a Dual-Beam Scanning Electron Microscope for Cryo-Electron Tomography

Presented here is a protocol for preparing cryo-lamellae from plunge-frozen grids of Plasmodium falciparum-infected human erythrocytes, which could easily be adapted for other biological samples. The basic principles for preparing samples, milling, and viewing lamellae are common to all instruments and the protocol can be followed as a general guide to on-grid cryo-lamella preparation for cryo-electron microscopy (cryoEM) and cryo-electron tomography (cryoET). Electron microscopy grids supporting the cells are plunge-frozen into liquid nitrogen-cooled liquid ethane using a manual or automated plunge freezer, then screened on a light microscope equipped with a cryo-stage. Frozen grids are transferred into a cryo-scanning electron microscope equipped with a focused ion beam (cryoFIB-SEM). Grids are routinely sputter coated prior to milling, which aids dispersal of charge build-up during milling. Alternatively, an e-beam rotary coater can be used to apply a layer of carbon-platinum to the grids, the exact thickness of which can be more precisely controlled. Once inside the cryoFIB-SEM an additional coating of an organoplatinum compound is applied to the surface of the grid via a gas injection system (GIS). This layer protects the front edge of the lamella as it is milled, the integrity of which is critical for achieving uniformly thin lamellae. Regions of interest are identified via SEM and milling is carried out in a step-wise fashion, reducing the current of the ion beam as the lamella reaches electron transparency, in order to avoid excessive heat generation. A grid with multiple lamellae is then transferred to a transmission electron microscope (TEM) under cryogenic conditions for tilt-series acquisition. A robust and contamination-free workflow for lamella preparation is an essential step for downstream techniques, including cellular cryoEM, cryoET, and sub-tomogram averaging. Development of these techniques, especially for lift-out and milling of high-pressure frozen samples, is of high-priority in the field.

59 BASIC BIOLOGICAL SCIENCES↗

Surface deposition of nanometer scale carbon structures on Bi 2 Sr 2 CaCu 2 O 8+δ using a low-cost scanning electron microscope

In this work, we investigate optically active nanostructures on Bi 2 Sr 2 CaCu 2 O 8+δ (BSCCO). The nanostructures are constructed from carbon nanocrystals formed using the electron beam of a scanning electron microscope to locally decompose residual hydrocarbons at the BSCCO surface. Atomic force microscopy is used to characterize the dimensions of these structures as a function of beam exposure time. This technique has been used to induce localized intercalation to form carbon nanoparticles up to tens of nanometers into a variety of 2D materials. Cross-sectional scanning transmission electron microscopy in BSCCO shows the presence of these carbon deposits on the surface, but there is no evidence they penetrate into the BSCCO substrate. Therefore, this technique is not suitable for localized intercalation in BSCCO, and it does have promise as a cost-effective approach to pattern nanometer scale etch stops.

2D materials↗

Nanoscale Three-Dimensional Imaging of Integrated Circuits Using a Scanning Electron Microscope and Transition-Edge Sensor Spectrometer

X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but it is difficult to implement due to the competing requirements of X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial resolution while addressing the limitations of conventional tomography tools. The instrument combines the electron beam of a scanning electron microscope (SEM) with the precise, broadband X-ray detection of a superconducting transition-edge sensor (TES) microcalorimeter. The electron beam generates a highly focused X-ray spot on a metal target held micrometers away from the sample of interest, while the TES spectrometer isolates target photons with a high signal-to-noise ratio. This combination of a focused X-ray spot, energy-resolved X-ray detection, and unique system geometry enables nanoscale, element-specific X-ray imaging in a compact footprint. The proof of concept for this approach to X-ray nanotomography is demonstrated by imaging 160 nm features in three dimensions in six layers of a Cu-SiO 2 integrated circuit, and a path toward finer resolution and enhanced imaging capabilities is discussed.

47 OTHER INSTRUMENTATION↗

X-ray diffraction and scanning electron microscope characterizations of the salt waste processing facility tank 101 and tank 104 solid samples

The “as-received” Salt Waste Processing Facility (SWPF) Tank 101 and two Tank 104 samples (pre-wash and washed solids) have been characterized using x-ray diffraction (XRD) and scanning electron microscope/energy dispersive x-ray (SEM/EDX) techniques to address the concerns for the existence of solids, which may interfere with the operational performance of the SWPF crossflow filtration process.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimal Geometry for Focused Ion Beam-Milled Samples for Direct-Pull Micro-Tensile Testing Performed In Situ in a Scanning Electron Microscope

A thorough procedure was developed to efficiently manufacture dogbone samples using focused ion beam (FIB) milling for micro-tensile testing. A Bruker PI 89 PicoIndenter, Billerica, MA, USA, was used as a case study, although the analysis and results are applicable to other micro-mechanical testing systems capable of mounting a standard, Ø12.7 mm × Ø3.2 mm pin, scanning electron microscopy (SEM) pin stub (Ted Pella, Redding, CA, USA). Nine dogbones were made from an Fe-45Cu alloy additively manufactured using powder-fed laser-directed energy deposition (DED-LB). Testing showed that fracture was confined to the gauge section for all dogbones and that the fracture mode, ductile vs. brittle, was entirely dependent on the grain orientation relative to the loading direction. The analysis showed that the measured plastic strain to failure can vary from >11% (optimal geometry) to <1% (non-optimal geometry) in micro-tensile testing of high-tensile-strength (>1 GPa) metallic materials. Subsequently, a finite element analysis (FEA) was conducted to identify the improved dogbone geometries. A total of ten thousand dogbone geometries were tested, and their dimensions were defined by a set of four adjustable parameters (corner radius, load surface angle, load surface length, and dogbone head length). The gauge width and gauge length were fixed to 4 µm and 10 µm, respectively. Three-dimensional surface plots of the stress concentration as a function of two parameters were used to identify the optimal ranges of parameter values. The addition of maximum width and length constraints, measuring 25 µm and 30 µm, respectively, allowed us to identify an optimal geometry at load surface angles of 30° and 45°. Their respective dimensions (corner radius, load surface length, and dogbone head length) are, in µm, 12, 6, and 7 and 10, 7, and 7. Testing these two optimal geometries with a range of gauge lengths from 4 to 20 µm showed that smaller gauge lengths only slightly reduced the detrimental stress concentration outside the gauge section. However, smaller gauge lengths will notably improve the FIB surface polishing step as tapering is reduced with smaller dogbone lengths.

Chemistry↗

Insights into Chemical Prelithiation of SiO x /Graphite Composite Anodes through Scanning Electron Microscope Imaging

Initial Coulombic efficiency (ICE) is critical for determining the energy density of lithium-ion batteries (LIBs) used for practical applications; however, it is typically disregarded in anode research. We used SiO x and graphite composite anodes for commercial lithium-ion batteries in our preliminary research to achieve a balance between ICE, capacity, and cycling life. ICE reached 88%; however, it needs further improvement for commercial applications. Prelithiation is a process that involves the introduction of extra lithium ions into LIBs during their manufacturing to enhance the overall performance of the LIBs. We applied a chemical prelithiation method on our SiO x /graphite composite anodes, which comprised 95 wt % of the active material mass loading on the electrode. The ICE increased from 88% to 98% using an aryllithium reagent impregnation method within 2 min of prelithiation. The anode’s specific capacity density, rate, and cycle performance also significantly improved. Scanning electron microscopy (SEM) imaging enhanced by an osmium tetroxide staining method indicated that the P-anode contained a stable solid electrolyte interface (SEI) layer after the prelithiation process and cycling electrochemical test. The P-anode’s stable charge differential peak over 500 cycles also showcases a robust artificial SEI layer that was generated by the prelithiation procedure. Here, this prelithiation process has significant potential for adoption in the LIB industry’s current electrode manufacturing process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of nitriding on mechanical and microstructural properties of Direct Metal Laser Sintered 17-4PH stainless steel

In this work, the effect of the nitriding process on microstructure and mechanical properties of additively manufactured (AM) 17-4PH stainless steel is investigated. The nitriding was performed at 530 °C, 560 °C, and 580 °C for 2 h. The nitriding process improves the hardness and surface roughness of the AM 17-4PH steel. Detailed microstructural characterizations of both as-built and nitride samples are performed using an optical microscope, scanning electron microscope (SEM) equipped with energy-dispersive X-ray spectroscopy (EDS), and X-ray diffraction technique. It reveals that the nitride layer thickness increases with nitriding temperature. A distinct transition layer between the substrate and nitride layer is observed in the 560 °C and 580 °C nitride samples. The nitriding process develops almost equiaxed grain microstructure with new secondary phase precipitates, whereas in the as-built material, the grains are primarily columnar along the AM process build direction. Specifically, the nitriding process introduces γ-Fe4N, ε-Fe3N, CrN, and Ni3N precipitates. The increase in Ni- and Cu-rich precipitates with the nitriding temperature explains the observed improvement in the hardness and surface roughness. Furthermore, the nitriding process does not alter the substrate's initial weak crystallographic texture.

17-4PH steel↗

Mineralogy and petrology of fine‐grained samples recovered from the asteroid (162173) Ryugu

Abstract Samples returned from the carbonaceous asteroid (162173) Ryugu by the Hayabusa2 mission revealed that Ryugu is composed of materials consistent with CI chondrites and some types of space weathering. We report detailed mineralogy of the fine‐grained Ryugu samples allocated to our “Sand” team and report additional space weathering features found on the grains. The dominant mineralogy is composed of a fine‐grained mixture of Mg‐rich saponite and serpentine, magnetite, pyrrhotite, pentlandite, dolomite, and Fe‐bearing magnesite. These grains have mineralogy comparable to that of CI chondrites, showing severe aqueous alteration but lacking ferrihydrite and sulfate. These results are similar to previous works on large Ryugu grains. In addition to the major minerals, we also find many minerals that are rare or have not been reported among CI chondrites. Accessory minerals identified are hydroxyapatite, Mg‐Na phosphate, olivine, low‐Ca pyroxene, Mg‐Al spinel, chromite, manganochromite, eskolaite, ilmenite, cubanite, polydymite, transjordanite, schreibersite, calcite, moissanite, and poorly crystalline phyllosilicate. We also show scanning transmission electron microscope and scanning electron microscope compositional maps and images of some space‐weathered grains and severely heated and melted grains. Although our mineralogical results are consistent with that of millimeter‐sized grains, the fine‐grained fraction is best suited to investigate impact‐induced space weathering.

Geochemistry & Geophysics↗

Cation Migration and LSCF/SDC Decomposition Related to Long-Term Operation Mode as Revealed by Electron Microscopy

This study utilized energy dispersive spectroscopy (EDS) in a scanning electron microscope (SEM) and a scanning transmission electron microscope (STEM) in order to track cation migration and related particle decomposition for air electrode components of solid oxide cells. The influence of a Sm-doped ceria (SDC) barrier layers was assessed for three operation modes (fuel cell, electrolysis, reversible) over long time periods (1000-1500 hours). Composition profiles across air electrode/electrolyte interfaces indicated negligible accumulation of La/Sr cations to the yttria-stabilized zirconia (YSZ) electrolyte during operation. Instead, air electrode particles composed of SDC and/or La-Sr-Co-Fe-oxides (LSCF) exhibited decomposition by Sr evaporation and Sm migration to LSCF particle edges.

Picard, Yoosuf↗