Search NASA⌕ Search

SEARCH · Search NASA

Results for “scanning mode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Hologic QDR 2000 whole-body scans: a comparison of three combinations of scan modes and analysis software

This study reports on the short-term in vivo precision and absolute measurements of three combinations of whole-body scan modes and analysis software using a Hologic QDR 2000 dual-energy X-ray densitometer. A group of 21 normal, healthy volunteers (11 male and 10 female) were scanned six times, receiving one pencil-beam and one array whole-body scan on three occasions approximately 1 week apart. The following combinations of scan modes and analysis software were used: pencil-beam scans analyzed with Hologic's standard whole-body software (PB scans); the same pencil-beam analyzed with Hologic's newer "enhanced" software (EPB scans); and array scans analyzed with the enhanced software (EA scans). Precision values (% coefficient of variation, %CV) were calculated for whole-body and regional bone mineral content (BMC), bone mineral density (BMD), fat mass, lean mass, %fat and total mass. In general, there was no significant difference among the three scan types with respect to short-term precision of BMD and only slight differences in the precision of BMC. Precision of BMC and BMD for all three scan types was excellent: < 1% CV for whole-body values, with most regional values in the 1%-2% range. Pencil-beam scans demonstrated significantly better soft tissue precision than did array scans. Precision errors for whole-body lean mass were: 0.9% (PB), 1.1% (EPB) and 1.9% (EA). Precision errors for whole-body fat mass were: 1.7% (PB), 2.4% (EPB) and 5.6% (EA). EPB precision errors were slightly higher than PB precision errors for lean, fat and %fat measurements of all regions except the head, although these differences were significant only for the fat and % fat of the arms and legs. In addition EPB precision values exhibited greater individual variability than PB precision values. Finally, absolute values of bone and soft tissue were compared among the three combinations of scan and analysis modes. BMC, BMD, fat mass, %fat and lean mass were significantly different between PB scans and either of the EPB or EA scans. Differences were as large as 20%-25% for certain regional fat and BMD measurements. Additional work may be needed to examine the relative accuracy of the scan mode/software combinations and to identify reasons for the differences in soft tissue precision with the array whole-body scan mode.

NASA Discipline Musculoskeletal↗

Scanning Mode Sensor for Detection of Flow Inhomogeneities

A scanning mode sensor and method is provided for detection of flow inhomogeneities such as shock. The field of use of this invention is ground test control and engine control during supersonic flight. Prior art measuring techniques include interferometry, Schlieren, and shadowgraph techniques. These techniques, however, have problems with light dissipation. The present method and sensor utilizes a pencil beam of energy which is passed through a transparent aperture in a flow inlet in a time-sequential manner so as to alter the energy beam. The altered beam or its effects are processed and can be studied to reveal information about flow through the inlet which can in turn be used for engine control.

Adamovsky, Grigory↗

Scanning Mode Sensor for Detection of Flow Inhomogeneities

A scanning mode sensor and method is provided for detection of flow inhomogeneities such as shock. The field of use of this invention is ground test control and engine control during supersonic flight. Prior art measuring techniques include interferometry. Schlieren, and shadowgraph techniques. These techniques. however, have problems with light dissipation. The present method and sensor utilizes a pencil beam of energy which is passed through a transparent aperture in a flow inlet in a time-sequential manner so as to alter the energy beam. The altered beam or its effects are processed and can be studied to reveal information about flow through the inlet which can in turn be used for engine control.

Adamovsky, Grigory↗

Inter-Calibrating CERES Instrument Fluxes Utilizing the CERES Instrument Geostationary Scan Mode Observations

The NASA Clouds and the Earth’s Radiant Energy System (CERES) project provides the scientific community observed top-of-atmosphere (TOA) fluxes to monitor the Earth’s energy imbalance and validate climate models. The CERES instruments onboard the Terra, Aqua, SNPP and NOAA-20 satellites need to be inter-calibrated to provide a continuous and consistent TOA flux record contained in the CERES Energy Balanced and Filled (EBAF) product. The SNPP and NOAA-20 satellites are positioned a half an orbit apart within the same sun-synchronous orbit (1:30 PM equatorial crossing time) thus preventing any direct time-matched observations. The CERES project designed the geostationary scan mode (GEOscan) to inter-calibrate the Geostationary Earth Radiation Budget (GERB) broadband measurement onboard the Meteosat 8-11 satellites. By rotating the orientation of the CERES instrument scan to match the angular configuration of the geostationary scan mode, the comparison of both angle and time matched observations suitable for inter-calibration is possible. To determine if the GEOscan mode is useful for inter-calibrating two CERES instruments placed in the same 16-day repeating orbit, the CERES project placed the Terra and Aqua CERES instruments in GEOscan mode once every 6 days over a rotation of five geostationary domains beginning in February 2023. The GEO imager narrowband to broadband derived radiances are used as transfer radiometers to compare the Terra and Aqua CERES observed radiances. Since both the Terra and Aqua CERES instruments are in GEOscan mode over the same GEO domain and day, the GEO imager calibration is expected to be consistent between the Terra and Aqua overpass times. Any GEO imager narrowband to broadband regional biases should be similar for the Terra and Aqua overpasses. The GEOscan mode Terra and Aqua CERES inter-calibration coefficients for both shortwave and longwave broadband radiances will be compared against the CERES instrument team’s coefficients to determine the viability of this approach. Improvements in the GEO imager narrowband to broadband approaches will also be investigated and verified within this framework.

Kyle Itterly↗

Scanning Mode Shock Position Sensor Invented and Demonstrated

A flow-visualizing system with a scanning optical beam offers greater advantages than the conventional approaches. In addition to a higher signal-to-noise ratio and lower source power, the scanning permits visualization of weak phenomena such as the scattering and diffraction of light on shocks. Scanning beam flow-visualization techniques were evaluated at the NASA Lewis Research Center for shock position sensing. In an effort to eliminate moving parts, a spectral scanning technique was invented and demonstrated.

Adamovsky, Grigory↗

Measurements of atmospheric nitric oxide from Nimbus 7 SBUV ultraviolet spectral scan data

Results are given of SBUV (solar backscattered ultraviolet instrument) measurements from Nimbus 7, when - one day per month - it is operated in a spectral scan mode, scanning from 160 nm to 400 nm in 0.2-nm steps. By measuring the intensity of a series of nitric oxide (NO) gamma band fluorescence features in this wavelength range, it has been possible to estimate the amount of NO in the upper stratosphere and mesosphere. The background of atmospherically scattered sunlight normally masks the much weaker NO gamma band emission, but these emission features are discriminated by subtracting a synthetic spectrum calculated for a model atmosphere that includes only Rayleigh scattering and absorption by ozone and oxygen. The resulting difference plot clearly reveals features resulting from processes not included in the simple model, such as NO gamma band emission. Nitric oxide is inferred by measuring the absolute intensity of various bands relative to the adjacent background and relating this intensity to total NO above an altitude determined by the backscattering contribution function for that band. NO observations near the solstice and at various latitudes are reported.

Mcpeters, R. D.↗

Wind Event Warning System

A method of detecting a wind event utilizing Doppler lidar includes causing a Doppler lidar unit to operate in a course scan mode in which a lidar beam is scanned along several directions. Line-of-sight wind speed measurements are generated at each direction and a derivative with respect to distance of the line-of-sight wind speed measurements is calculated at each of the directions. A predicted angular position of a wind event is determined, and the lidar unit may then operate in a fine scan mode in which only a limited sector is scanned. The potential wind event is then quantified utilizing data obtained using the fine scan mode.

Koch, Grady J.↗

Biomedical ultrasonoscope

The combination of a "C" mode scan electronics in a portable, battery powered biomedical ultrasonoscope having "A" and "M" mode scan electronics, the latter including a clock generator for generating clock pulses, a cathode ray tube having X, Y and Z axis inputs, a sweep generator connected between the clock generator and the X axis input of the cathode ray tube for generating a cathode ray sweep signal synchronized by the clock pulses, and a receiver adapted to be connected to the Z axis input of the cathode ray tube. The "C" mode scan electronics comprises a plurality of transducer elements arranged in a row and adapted to be positioned on the skin of the patient's body for converting a pulsed electrical signal to a pulsed ultrasonic signal, radiating the ultrasonic signal into the patient's body, picking up the echoes reflected from interfaces in the patient's body and converting the echoes to electrical signals; a plurality of transmitters, each transmitter being coupled to a respective transducer for transmitting a pulsed electrical signal thereto and for transmitting the converted electrical echo signals directly to the receiver, a sequencer connected between the clock generator and the plurality of transmitters and responsive to the clock pulses for firing the transmitters in cyclic order; and a staircase voltage generator connected between the clock generator and the Y axis input of the cathode ray tube for generating a staircase voltage having steps synchronized by the clock pulses.

Lee, R. D.↗

Infrared Transmission Spectroscopy of the Exoplanets HD 209458b and XO-1b Using the Wide Field Camera-3 on the Hubble Space Telescope

Exoplanetary transmission spectroscopy in the near-infrared using the Hubble Space Telescope (HST) NICMOS (Near Infrared Camera and Multi-Object Spectrometer) is currently ambiguous because different observational groups claim different results from the same data, depending on their analysis methodologies. Spatial scanning with HST/WFC3 (Wide Field Camera-3) provides an opportunity to resolve this ambiguity.We here report WFC3 spectroscopy of the giant planets HD 209458b and XO-1b in transit, using spatial scanning mode for maximum photon-collecting efficiency. We introduce an analysis technique that derives the exoplanetary transmission spectrum without the necessity of explicitly decorrelating instrumental effects, and achieves nearly photon-limited precision even at the high flux levels collected in spatial scan mode. Our errors are within 6 percent (XO-1) and 26 percent (HD 209458b) of the photon-limit at a resolving power of lambda divided by delta times lambda approximating 70, and are better than 0.01 percent per spectral channel. Both planets exhibit water absorption of approximately 200 ppm at the water peak near 1.38 m. Our result for XO-1b contradicts the much larger absorption derived from NICMOS spectroscopy. The weak water absorption we measure for HD209458b is reminiscent of the weakness of sodium absorption in the first transmission spectroscopy of an exoplanet atmosphere by Charbonneau et al. Model atmospheres having uniformly distributed extra opacity of 0.012 square centimeters per gram account approximately for both our water measurement and the sodium absorption. Our results for HD 209458b support the picture advocated by Pont et al. in which weak molecular absorptions are superposed on a transmission spectrum that is dominated by continuous opacity due to haze and or dust. However,the extra opacity needed for HD 209458b is grayer than for HD 189733b, with a weaker Rayleigh component.

planetary systems↗

Technical issues in focal plane development for terrestrial resource observations

Performance goals for solid-state detector arrays operating in the pushbroom scan mode for the high-resolution, high-accuracy remote sensing of earth resources from space are discussed and some of the focal plane and system trades involved are identified. Issues in the development of solid-state pushbroom arrays with radiometric calibration to 0.5% precision detector-to-detector over a dynamic range of 1000:1 are considered, with calibration, temporal stability and spectral response conditions noted. Factors influencing the geometric precision of satellite-borne pushbroom scan mode sensors are then examined, including satellite orbit track and attitude errors, and geometric and radiometric correlation between information in the various spectral bands. Approaches to the alignment of linear arrays of thousands of detectors are then discussed that take into account tradeoffs between fabrication and test complexity and ground processing requirements. Continuing science experiments are indicated as necessary to establish tolerances on performance goals.

Thompson, L. L.↗

The analysis of a rocket tomography measurement of the N2+3914A emission and N2 ionization rates in an auroral arc

Techniques were developed for recovering two-dimensional distributions of auroral volume emission rates from rocket photometer measurements made in a tomographic spin scan mode. These tomographic inversion procedures are based upon an algebraic reconstruction technique (ART) and utilize two different iterative relaxation techniques for solving the problems associated with noise in the observational data. One of the inversion algorithms is based upon a least squares method and the other on a maximum probability approach. The performance of the inversion algorithms, and the limitations of the rocket tomography technique, were critically assessed using various factors such as (1) statistical and non-statistical noise in the observational data, (2) rocket penetration of the auroral form, (3) background sources of emission, (4) smearing due to the photometer field of view, and (5) temporal variations in the auroral form. These tests show that the inversion procedures may be successfully applied to rocket observations made in medium intensity aurora with standard rocket photometer instruments. The inversion procedures have been used to recover two-dimensional distributions of auroral emission rates and ionization rates from an existing set of N2+3914A rocket photometer measurements which were made in a tomographic spin scan mode during the ARIES auroral campaign. The two-dimensional distributions of the 3914A volume emission rates recoverd from the inversion of the rocket data compare very well with the distributions that were inferred from ground-based measurements using triangulation-tomography techniques and the N2 ionization rates derived from the rocket tomography results are in very good agreement with the in situ particle measurements that were made during the flight. Three pre-prints describing the tomographic inversion techniques and the tomographic analysis of the ARIES rocket data are included as appendices.

Mcdade, Ian C.↗

Characterization of an advanced focal plane for multispectral linear array (MLA) application

It is pointed out that the MLA instrument represents the next generation in the Landsat series of earth resources satellites. The MLA sensor concept utilizes a pushbroom scan mode to eliminate electromechanical scan mirrors, and the lower reliabililty and higher power dissipation which accompany their employment. The pushbroom scanner makes use of a linear array which consists generally of thousands of detectors oriented perpendicular to the along-track direction of the satellite. Test techniques have been developed for the measurement of the module parameters which are critical to MLA focal plane performance. These measurements include the determination of infrared responsivity, linearity over the dynamic range, temporal noise, and fixed pattern effects on each detector element of each module tested. Tests related to spectral response, crosstalk, and spot scan profiles are also conducted. A description is provided of the test equipment involved.

King, P.↗

Limb-darkening models from along-track operation of the ERBE scanning radiometer

During January and August 1985, the scanning radiometers of the Earth Radiation Budget Experiment(ERBE) aboard the Earth Radiation Budget Satellite (ERBS) and the NOAA-9 satellite were operated in along-track scanning modes. Along-track scanning permits the study of many measurement problems. It provides the data for developing a limb-darkening model for a single site over a short period of time and also permits the indentification of the scene from data taken at smaller nadir angles. The earth-emitted radiation measured by the scanners has been analyzed to produce limb-darkening models for a variety of scene types. Limb-darkening models relate the radiance in any given direction to the radiant flux. The scene types were computed using measurements within 10 deg of zenith. The models have values near zenith of 1.02-1.09. The typical zenith values of the model are 1.06 for both day and night for ERBS, and for NOAA-9, 1.06 for day and 1.05 for night. Mean models are formed for the ERBS and NOAA-9 results and are found to differ less than 1%, the ERBS results being the higher. The models vary about 1% with latitude near zenith and agree with earlier models that were used to analyze ERBE data typically to 2%.

Smith, G. Louis↗

The UAH/NSSTC Advanced Radar for Meteorological and Operational Research (ARMOR)

The past four years have seen a marked enhancement in meteorological-radar infrastructure and radar-research capability at the University of Alabama-Huntsville (UAH) and National Space Science and Technology Center (NSSTC; a collaborative center supported by UAH, NASA-MSFC and USRA). This enhancement is due in part to the development of the ARMOR C-band dual-polarimetric radar facility (amongst other mobile radar facilities also discussed in this conference). The ARMOR radar, located at Huntsville International Airport, originated as a unique collaboration between university, government and broadcast meteorologists (the very first of its kind relative to concurrent operational, research and broadcast applications of dual-polarimetry). Contributions from each of these entities resulted in the upgrade of a surplus National Weather Service WSR-74C radar to a research-grade C-band polarimetric radar. The initial upgrade of the radar took place in late 2004 with WHNT-TV purchase and installation of a SIGMET (now Vaisala) Antenna Mounted Receiver (AMR), RVP8/RCP8 radar processor/antenna controller, new radome, and a new dual-polarimetric antenna feed. The AMR enabled simultaneous transmit and receive (STSR) capability and hence collection of dual-polarimetric moments. During the initial part of the AMR upgrade the original WSR74C antenna reflector and 250 kW magnetron-transmitter were used. In early 2005, a new 350 kW magnetron transmitter was purchased from Baron Services and installed. In October of 2006 a new high performance parabolic antenna and dual-pol feed (Seavey) were installed together with a new Orbit pedestal. ARMOR Radar control and data delivery are facilitated through the use of T-1 lines that run from the airport to both NSSTC and WHNT-TV in Huntsville. Under current operating protocols radar scanning and product development are completed at NSSTC, though meteorologists at WHNT-TV can also control the radar if desired. In its default scanning configuration the radar is operated 24/7 in an STSR polarimetric rain scan mode alternating with a surveillance scan on a 5-minute cycle; scans separated by 2.5 minutes. Every 2.5 minutes the raw data arrive at NSSTC where they are corrected in real time for attenuation and differential attenuation (using a constrained ZDR/Z-PHI approach) and new products are generated (e.g., rain maps, hydrometeor identification etc.). The raw and derived products are archived at NSSTC and also redistributed locally in real time over the network within NSSTC to the National Weather Service Forecast Office in Huntsville (collocated with NSSTC) for operational use. During periods of interesting weather the radar is often operated in full, sector, or RHI volume modes from NSSTC and coincident with UAH mobile radar or NWS NEXRAD radar platforms as needed.

Petersen, Walter A.↗

Laser absorption measurements of OH concentration and temperature in pulsed facilities

A laser absorption flow diagnostic application has been developed at the NASA Ames 16-inch Shock Tunnel for purposes of measuring the thermochemical state of OH in flow environments of interest. Research objectives include the investigation of high temperature, low pressure chemistry pertinent to scramjet combustors and high altitude flight. The system can be operated in either the fixed frequency mode or in the rapid wavelength scanning mode to measure species mole fraction and temperature. Emission diagnostics have been employed to determine shock tunnel flow quality and assist in the proper application of the diagnostic and its data interpretation. Rotational lines in the OH system were probed in the expanding facility nozzle flow, and time-resolved measurements of temperature and mole fraction are provided.

Cavolowsky, John A.↗

Spatial Characterization of PACE OCI ETU Using Time-Delay Mode

The OCI (Ocean Color Instrument) is the main sensor on the upcoming PACE (Plankton Aerosol Cloud ocean Ecosystem) mission. OCI has two hyperspectral CCD sensors covering 340nm to 885nm and 9 SWIR (Short Wave IR) bands from 940nm to 2260nm. SWIR bands have nominal 1km ground pixel size and CCD bands have native 1/8 km ground pixel size in diagnostic mode that will be aggregated into 1km pixels to improve SNR and meet the data rate constraints. OCI has a rotating telescope that is synchronized to the readout of the CCD and SWIR detectors. Full pre-launch system level testing for the OCI ETU (Engineering Test Unit) was completed in June 2021.With time-delayed scan mode, a sub-pixel level time-delay step is applied to the detector readout. This sub-pixel level time-delay step causes a sub-pixel level shift in the start of the data collection. After collecting time-delay step scans with different step sizes, a scan profile with sub-pixel resolution can be constructed. 1/8 and 1/4 of CCD pixel resolutions were achieved using this mode. In this paper, the OCI time-delayed scan mode will be described as well as how it was used to calculate OCI’s high spatial resolution PSF (Point Spread Function), IFOV (instantaneous Field of View), MTF (Modulation Transfer Function), and BBR (Band to Band Registration).

PACE↗

Minimum acquisition time detection

Two different methods of target detection when the return signal is contaminated with noise are discussed and compared. The first method uses Neyman-Pearson detection philosophy and selects the threshold level to give a desired false alarm probability. The maximum probability of false alarm is constrained by the target cross scan velocity component. The second method (minimum acquisition time detection), which is similar to the ideal observer, selects the threshold level to minimize the expected target acquisition time. The probabilities of false alarm and missed detection are selected so that the errors produced by these effects produce the minimum acquisition time. Three different scan techniques - linear, spiral and two-mode scan - are studied and compared.

Brock, H. I.↗