Search NASA⌕ Search

SEARCH · Search NASA

Results for “seal quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Leak test for solid oxide fuel cells and solid oxide electrolysis cells

A simple, fast, and economical alcohol penetration method for assessing the solid oxide cell to metal window frame seal in a typical planar design is presented. An alcohol such as ethanol or isopropanol is placed into the cavity of a cell sealed to the window frame. Within 3–5 min, one can determine if the glass seal is hermetic by visual observation along the seal edges on the side of the sealed frame. Cross bubbling and open circuit voltage methods for determining whether the seal failed or cracked at high temperature after final stack firing are also discussed.

25 ENERGY STORAGE↗

Williston Basin Resource Study for Commercial-Scale Subsurface Hydrogen Storage

The Energy & Environmental Research Center (EERC), in partnership with the U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL), the EERC’s State Energy Research Center (SERC), MPLX Operations LLC, and TC Energy Development Holdings Inc. (a subsidiary of TC Energy Corporation), studied the potential for subsurface hydrogen storage and recovery in the Williston Basin of western North Dakota. The project’s goal was to evaluate the feasibility of large-scale, secure geologic H 2 storage to support future hydrogen generation, storage, and use. This work included laboratory testing, H 2 –rock–fluid exposure experiments, literature reviews on H 2 embrittlement, and reservoir modeling and simulations. The study included an assessment of storage potential across three types of storage reservoirs using both reservoir simulation and DOE’s web-based tool SHASTA-HELP (Subsurface Hydrogen Assessment, Storage, and Technology Acceleration – Hydrogen Estimator for Logistical Planning), as well as investigation of potential H 2 production and markets for commercial-scale deployment. Building on prior EERC gas storage research, three storage options were selected for detailed evaluation: the Broom Creek Formation (a clastic saline reservoir), the Dickinson Lodgepole Mounds (DLM) complex (carbonate mud mound structures) of the Lodgepole Formation (an active oil and gas producing reservoir), and the Dunham Salt Interval of the Piper Formation (to be used for engineered salt cavern development). These targets were prioritized based on prior EERC research using datasets related to seal capacity, reservoir quality, mechanical integrity, and injectivity. Exposure tests on Broom Creek and DLM samples showed mineral dissolution and precipitation that increased brine salinity and altered reservoir rock surfaces. Although these results provide useful insight, they are limited by small sample sizes and short-term (30-day) exposure, requiring further study to assess long-term storage integrity. Salt formations were not tested because of their known nonreactivity and established mechanical stability. Results of reservoir simulations performed for a single site demonstrated that the Broom Creek Formation may be capable of receiving up to 42,000 tonnes of injected H 2 over 7 months via one well. H 2 recovery took place over 5 months, resulting in approximately 26,000 tonnes (~62% without cushion gas [CG]). This work suggests water production may be important and subsequent cycles of injection and production may perform more efficiently; however, significant site-specific work in the future is needed to assess actual reservoir performance of injection and withdrawal of H 2 storage. For oil reservoir potential, a multiple-well model was used to simulate injection of approximately 32,000 tonnes of H 2 into a single wellbore while simultaneously producing in place reservoir fluids from four offset wells to maintain reservoir pressure. The simulation results suggested a high recovery (~98%); in addition, cost advantages through existing infrastructure could be realized. Challenges in this reservoir include vi managing gas purity and leakage risks. In both scenarios, production of H 2 takes place in a single-well scenario with 10 cycles (7 months of injection and 5 months of production) over 10 years. Finally, the use of engineered caverns in the Dunhan Salt was evaluated, and the results suggest that while they have a smaller capacity (<1000 tonnes per cavern), they exhibit nearly complete gas recovery (>99%), fast response times, and low purity risk. While caverns in North Dakota may be smaller in capacity, fields can be developed in galleries to accommodate the volumetric needs and rapid turnaround times necessary to meet market demands. Geographic limitations and thin salt intervals in North Dakota may represent less total storage potential than salt domes elsewhere, but significant opportunities exist to expand this market for gas storage in North Dakota. A basinwide assessment was performed to estimate a first-of-its-kind value for H 2 storage on a large scale. DOE’s SHASTA-HELP, combined with EERC simulation work, was used to perform the assessment. Estimated H 2 storage potential varied widely for each formation type. The Broom Creek saline formation was estimated to have a storage potential of approximately 1.7–90.5 million tonnes (MMt). The DLM oil reservoirs were estimated to have 0.07–0.19 MMt of capacity. Notably, each of these estimates relies on significant assumptions regarding reservoir thickness, porosity, permeability, and CG needed for operation. Much research is needed to understand the true site-specific storage resource potential of each formation. Using the Dunham Salt Interval for cavern development may result in as much as 4.79 MMt (up to 2.87 MMt working gas) of H 2 storage potential. An important note for consideration is that the values presented here need significantly more geological characterization and engineering assessments prior to gaining confidence in performance. This will be a focal point for future research and development needs. The basinwide evaluation also indicated that North Dakota has significant H 2 generation potential, with estimates up to a possible 13 MMt annually, suggesting a substantial opportunity for H 2 market development and thus the need for commercial-scale H 2 storage to facilitate growth and resilience. Key Recommendations 1. Conduct detailed site characterization (3D seismic, well logs, core sampling) to reduce geologic uncertainty. 2. Perform techno-economic analyses incorporating market, regulatory, and incentive frameworks. 3. Investigate long-term interactions among H 2 , CGs, well materials, and formations to assess risks. 4. Develop pilot- and field-scale demonstrations to validate models and establish best practices.

03 NATURAL GAS↗

NSTX-U Machine Core Vacuum Seals Upgrade Design

The vacuum in the National Spherical Torus Experiment Upgrade (NSTX-U) is in the range of 2.66x10⁻⁶ Pa (2x 10⁻⁸ torr). To enhance vacuum seals and lower gas permeation in the NSTX-U and therefore ensuring operation safety and quality, the machine core vacuum seal design has been upgraded using double elastomeric seals and pumped interspaces (guard channels). In NSTX-U machine core, there are six major vacuum seals, including upper and lower vacuum vessel main flanges, upper and lower bellows flanges, and two in the ceramic isolation ring assembly that are mounted to the upper vacuum vessel main flange. The elastomeric seals are commercially available and customized fluorocarbon (Viton) O-rings. To ensure appropriate O-ring compression ratios for the vacuum seal, the O-ring grooves are customized with appropriate tolerances considering specific situations for each seal. In this upgrade, the vacuum in each interspace is designed to reach 13.33 Pa (0.1 torr), thus the overall pressure difference crossing each double O-ring seal is expected to be reduced by at least three orders of magnitude, and accordingly the overall rates of leakage and permeation will be lowered by three orders of magnitude. The corresponding pump-down times for each seal, at room temperature, are estimated at about 60 s. Additionally, the vacuum pumped interspaces will be able to function as a real-time leak monitor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of coherence of niobium-based resonators enabled by a fast-sealing microwave cavity

Resonators and qubits with a niobium (Nb) base metal layer achieve some of the highest coherence times in superconducting quantum devices. The performance of such devices is often limited by loss associated with two-level systems, which are found primarily at material surfaces and interfaces. The metal-air (MA) interface is a major contributor to device loss. In this work, we develop a fast-sealing microwave cavity that enables devices to be placed under vacuum within five minutes of oxide removal, thereby significantly reducing the MA interface loss compared to common device processing and packaging approaches. Using coplanar stripline resonators, we demonstrate that devices sealed in such a cavity exhibit internal quality factors exceeding one million at single-photon power. After re-exposure to air, the devices show downward resonance frequency shifts and quality factor degradations, quantitatively consistent with a model of Nb oxide regrowth. The fast-sealing microwave cavity provides a practical and consistent method to mitigate MA interface loss and sustain high coherence in Nb devices, and establishes a controlled platform for studying metal oxide regrowth kinetics and dielectric properties, the understanding of which is critical to achieving high coherence in superconducting quantum devices.

Zhang, C. [Waterloo U., IQC; Waterloo U.]↗

Spectral broadening and compression of picosecond pulses in air using a multi-pass cell

We report the spectral broadening and post-compression of picosecond pulses using a multi-pass cell (MPC) operating in air. A 2 m-long bi-concave cavity with 41 reflections and 96.4% transmission was designed and implemented, optimized for the compression of 5.5 ps, 4.5 mJ pulses from a Yb:YAG laser operating at 1030 nm. A 19.3-fold spectral broadening was obtained, increasing the bandwidth from 0.3 nm to 5.8 nm, which enabled pulse compression down to 547 fs with a symmetric temporal profile close to the transform limit. These results demonstrate the feasibility of using open-air MPCs for high-energy picosecond pulse post-compression, without the need for sealed chambers, while preserving high mode quality and transmission. Scaling to pulse higher energy is discussed.

Zaldivar Escola, F. [Univ. of Buenos Aires (Argent↗

NREL 25-cm2 High-Pressure Low-Temperature Electrolysis Cell Hardware (Open Source)

This data resource describes an open-source cell hardware that enables low temperature electrolysis (LTE) testing at elevated pressures. Existing commercial options have several downsides when it comes to R&D testing. They are often not designed for repeated reassembly, may not be able to accommodate porous transport layers with different thicknesses, and do not give state-of-the-art performance. Therefore, this hardware was developed specifically with LTE R&D in mind and its design is being made available to the global LTE community. This work was planned and funded by the U.S. Department of Energy's H2NEW consortium (https://h2new.energy.gov/). The hardware design package (.zip file) details the drawings, auxiliary materials, and procedures required to fabricate, assemble, and operate the National Renewable Energy Laboratory's (NREL's) high-pressure low-temperature electrolysis cells. While the hardware itself—end plates, current collectors, flow fields, bolts and washers, tube fittings—is always the same, the assembly and operating procedures may change depending on the active materials being tested, especially for the membrane. Material-specific assembly and operating procedures will be posted to the H2NEW website as they are developed and validated. Disclaimer: The documents and drawings included in this download package describe a design for a low temperature electrolysis hardware that is intended to comply with leak testing according to ASME B31.1. Safe operation at ambient and elevated pressures is the sole responsibility of the end user, which should be evaluated on a case-by-case basis for each individual cell. Factors affecting the sealing capability may depend on, for example, machining quality, cell assembly components, operating conditions, and operating history. Operation at pressure should only be performed on qualified test stands by qualified operators. NREL/ALLIANCE FOR SUSTAINABLE ENERGY, LLC/DOE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, AND MAKES NO WARRANTY AS TO THE ACCURACY, COMPLETENESS, OR USEFULNESS OF ANY INFORMATION PROVIDED HEREIN. USE OF THIS PACKAGE IS AT THE USER’S OWN RISK.

08 HYDROGEN↗

Application of reference-free natural background–oriented schlieren photography for visualizing leakage sites in building walls

Air leakage in buildings can cause health and comfort concerns for occupants and can contribute to mold growth on building materials, or in extreme conditions, rot of building materials. Unwanted air leakage through the building envelope also contributes to approximately 4 quadrillion Btu (1172 TWh) of energy consumption per year in the building sector in the United States. Locating and sealing leakage sites can improve the energy efficiency, comfort, air quality, and moisture durability of the building stock. Typical methods of finding leakage sites, such as infrared imaging and smoke tracing, rely on concurrent blower door operation, which can also measure the total leakage rate of the building. Smoke tracing can be disruptive to occupants, and infrared imaging and smoke tracing cannot measure the contribution of individual leaks to prioritize sealing efforts. Here, an optical fluid flow imaging technique, reference-free natural background–oriented schlieren imaging, was adapted to visualize air exfiltration. This is the first step in developing a method to noninvasively locate and measure exfiltration or infiltration sites so that sealing efforts can be prioritized. Experimental results of this technique are presented, demonstrating the method's applicability to visualizing exfiltration through three common building claddings in an outdoor environment. Key variables impacting the performance of this technique when applied to building leakage are also discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Production of a Sustainable Aviation Fuel Additive from Waste Polystyrene

Sustainable aviation fuels (SAFs) are an important lever to achieving net zero CO 2 emissions in aviation. Fuel quality standards limit the blend volume of nonpetroleum-based jet fuel such as synthetic paraffinic kerosene (SPK) in Jet A to 50 vol %. One reason for this limit is the limited seal-swelling ability of SPK. Ethylbenzene (EB) as an additive can improve the swelling propensity of SPK. In this study, EB was produced through polystyrene pyrolysis, hydrogenation, and separation. The thermal pyrolysis of polystyrene produced a styrene-rich pyrolyzate. The pyrolyzate was hydrogenated by using Pd/C to produce an EB-rich mixture that yielded a crude EB of ∼90% purity on distillation. The O-ring swelling ability of crude EB of ∼90% purity was tested as a 12 and 16 vol % blend with SPK. Results reveal that EB addition enhanced seal swelling, but a more refined EB grade would be preferable. The results provide a pathway to address the twin issues of plastic pollution and SPK property improvement.

99 GENERAL AND MISCELLANEOUS↗

Energy Savings With Acceptable Indoor Air Quality Through Improved Airflow Control in Residential Retrofits

The Partnership for Advanced Residential Retrofit (PARR) has been a U.S. Department of Energy (DOE) Building America team since 2009, with a primary focus on upgrading the performance of existing buildings to reduce energy loads. In this project, PARR’s work explored the integration of airflow-focused measures in residential retrofit homes with the goal to maximize energy savings while ensuring acceptable indoor air quality (IAQ) using a systems approach to controlling four contributing air streams: • Building air leakage (natural, uncontrolled infiltration), • Forced-air distribution system static pressure and airflow rate, • Distribution system duct leakage, and • Mechanical ventilation. This project addressed airflows in houses, their combined impact on energy use and IAQ, and the comparative effects of typical insulation and air sealing practices versus integrated system-level retrofits. Additionally, practical considerations for contractors taking either approach were addressed. Finally, the effects of supply ventilation and exhaust ventilation on IAQ were compared in occupied homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MIS Shelf-Life Final Report for Plutonium Oxide Item 1000089 (SSR136 and SSR136A) from Rocky Flats Peroxide Precipitation and Calcination Process

A plutonium dioxide material from the Material Identification and Surveillance (MIS) Program inventory has been studied to determine the gas generation and corrosion behavior in a storage environment. Sample 1000089 represents product-quality plutonium oxides produced in the Rocky Flats peroxide precipitation process currently stored in 3013 containers. This study followed over time the gas pressure and composition of a sample with nominally 0.5 wt% water in a sealed container with an internal volume scaled to 1/500th of the volume of a 3013 container. Gas compositions had been measured periodically over almost 13 years. The maximum observed gas pressure was 204 kPa and was related to a temperature excursion. The maximum observed gas pressure from gas generation was 126 kPa. The increase over the initial pressure of 86.7 kPa was due to the generation of hydrogen, oxygen, and nitrogen. Carbon dioxide, methane and carbon monoxide were minor components of the headspace gas. The material exhibited unusual behavior in that the atmosphere reached flammable levels of hydrogen and oxygen within the first 30 days and remained flammable for the duration of the experiment. It has been determined that the sample inside the reactor was a mixture of the AR material, material calcined at 800 °C, and material calcined at 950 °C. The experiment was terminated in 2012 and unloaded in 2016. A new reactor, SSR136A, was loaded with the original sample freshly calcined at 950 °C. The total pressure inside SSR136A remained close to the initial value of 93 kPa. The total pressure is composed of He (steady levels after the reloading) and hydrogen which is 10% of the reactor’s total pressure. Nitrogen and oxygen compose trace amounts of the reactor headspace. The internal components of SSR136 were inspected in 2021, five years after it was removed from the array. The inside surfaces of the inner bucket exposed to the original sample for 4,576 days had an etched appearance, and pit-like features were observed in the microscopic analysis. No corrosion was observed on the SSR136A inner bucket that held the freshly calcined sample that was exposed for 1,303 days.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Challenges in practical button cell testing for hydrogen production from high temperature electrolysis of water

High temperature electrolysis of water using solid oxide electrochemical cells (SOEC) is a promising technology for hydrogen production with high energy efficiency and may promote decarbonization when coupled with renewable energy sources and excess heat from nuclear reactors. Over the past several decades there have been extensive scientific and engineering studies on cell materials and degradation behaviors that have greatly improved current density, decreased total resistance, and lowered degradation rates. Although the technology is now at a near-commercial level, maintaining consistency in cell testing and minimizing variance in practical testing environments is an often overlooked but crucial topic. To promote high quality data collection, testing procedures and balance of plant component details are extremely important to consider. This work discusses some key factors affecting the reproducibility of practical SOEC testing on the button cell level, namely, current collection layers, cell sealing procedures, the reliability of steam and hydrogen delivery systems, cell testing fixture design, and reduction procedures. To provide a baseline and a level of standardization for the SOEC community, this work also discloses details of the standard operating procedure and techniques adopted for o-SOEC testing at Idaho National Laboratory (INL).

08 HYDROGEN↗

Force-triggered, Bio-based, Sealants for Prefabricated Building Components: Towards Improved Efficiency, Performance and Sustainability

The prefabricated building construction industry has made extensive progress in expediting the manufacture of prefabricated components at offsite plants. However, this progress has not translated to the assembly of the prefabricated components at the construction site. Case in point, sealing the joints between components to prevent air leaks requires the manual application of tape, caulk, or spray foam at the jobsite, and performance is highly dependent on the skills of the installer. To reduce assembly time and improve assembly quality of prefabricated components, we developed a sealant that can be installed at the plant and triggered at the jobsite. Additionally, we used this opportunity to lower the use of fossil fuel derived feedstocks and introduced bio-based alternatives to decrease the embodied carbon of the new sealant. We evaluated a series of force-triggered, bio-based, high strength, and fast curing sealants, consisting of a one-part heterogeneous system. These sealants are derived from formulations with ≥80% of biogenic carbon, consisting of a cardanol derived diepoxy that is microencapsulated in a polymer shell and embedded in a cardanol derived amine curing agent. The microcapsule shell allows separation of the reactive species in the one part sealant allowing shelf stability to an otherwise fast curing system. When the microcapsules are broken and activated by force, the highly reactive species mix and cure, exhibiting peel strengths up to 143 ppi. The shelf stability of these sealants and the on-demand triggering of the curing reactions enable installation on prefabricated components and storage prior to delivery and assembly at a jobsite, which could result in consistent sealant application with lower installation time than tapes and caulks at the construction site.

Cortes Guzman, Karen [ORNL] (ORCID:000000028793468↗

Multifamily Air Leakage Evaluation: A Modular Case Study

The purpose of this case study is to compare the air leakage rates of modular and site-built multifamily dwelling units. The methods, materials, and equipment were observed to be very similar in the modular and site-constructed units in this case study. The installation quality of building envelope measures such as insulation and air barrier appeared to be better for modular construction, because they were installed in a controlled, factory setting. Through field observations, we identified cosmetic damage to the envelope of modular units following transport to the building site, but with no resulting significant air leakage pathways. However, we did see air leakage pathways resulting from field modifications to the envelope of modular units to accommodate structural and mechanical connections. We found that the extensive use of through-wall HVAC systems, combined with the transport, placement, and rework of modular units may compromise the high-quality envelope installation and airtightness observed in the factory without careful planning and/or design. Opportunities for improvement identified from the tested modular dwelling units include minimizing and optimally locating penetrations, pre-cutting and detailing penetrations at the factory where possible, properly sealing field modifications, and using split HVAC systems in place of through-wall packaged systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MR13A-3183: Microbial and Geochemical Characterization of Groundwater: Implications for Underground Hydrogen Storage Leakage

Underground hydrogen storage (UHS) in geological formations is a key element of the clean energy transition as it enables the decarbonization of the transportation and industrial sectors by decoupling hydrogen production and storage. UHS has many benefits, including low cost, much wider availability, large storage capacity, well-established infrastructure, and increased safety because of geological sealing capabilities. However, the impact of hydrogen (H2) biogeochemical interactions in the presence of subsurface microorganisms is largely neglected from UHS perspectives. These interactions might affect the effectiveness of storage and can even cause H2 to leak into the shallow aquifers. Leakage of H2 into groundwater can change the geochemistry and induce several microbial-driven processes. Microorganisms, such as sulfate-reducers, are naturally abundant in groundwater and consume H2 to produce hydrogen sulfide (H2S), which can contaminate the freshwater drinking groundwater and cause damage to infrastructure. Hydrogen leakage can also trigger microbial reactions responsible for metal mobility, which can impact the water quality. However, the kinetics of these reactions and the temporal impact of hydrogen leakage in groundwater are still unknown. Therefore, a time series hydrogen-groundwater interaction experiment was conducted, and the changes in fluid chemistry and headspace gas composition will be analyzed along with DNA sequencing results to understand the extent and kinetics of biogeochemical reactions that occur if hydrogen leaks into groundwater. In the experiments, Ultra High Purity (UHP) hydrogen gas will be injected into glass vials with groundwater samples, for a designated time period. For each glass-sealed vial, 16S rRNA gene sequencing, IC, ICP-MS, and GC-TCD will be performed. The experiments provide insights into plausible impacts of hydrogen leakage into shallow drinking water aquifers.

Clark, Allison [West Virginia University (WVU)]↗

What does it take to “see” air leakage through a building envelope?

Unwanted air leakage in buildings can cause health and comfort issues for the building occupants and contribute to rot and mold growth in building materials. Leakage also contributes to unnecessary energy consumption ~4 quads (1172 TWh) per year in the buildings sector in the United States. Finding and repairing leaks through the building envelope can improve the energy efficiency, comfort, air-quality, and moisture durability of the building stock. Typical methods of locating air leakage, such as infrared imaging or smoke tracing, rely on concurrent blower door operation which also measures the total leakage rate of the building. These methods can be disruptive to occupants and can’t measure the contribution of individual leaks to prioritize sealing efforts. ORNL is working on a refraction-based fluid flow imaging technique that can measure the leakage rate of individual leaks from the outside of the building. The working principle of this device is based on the refraction of light caused by the exfiltration because there is a small difference in density between the exfiltration and ambient air. We will discuss the operation of the air leak detector and key variables that affect its performance. We will also present preliminary results showing the visualization capability of this new air leak detector under different conditions. Experiments were completed with different claddings, air temperatures, and lighting conditions.

Boudreaux, Philip↗

Microscopic Measurement: Need for Nuclear Material Sample Specimen Characterization Capability

The Surveillance, Fabrication, and Off-Site Operations team at Lawrence Livermore National Laboratory is beginning an update to the nuclear material machining lab in Superblock. Plutonium and other nuclear materials tend to accelerate the aging process for equipment and machines that would otherwise be maintainable for long lives. They have their lifespans shortened from deteriorated seals, embrittled polymer components, accelerated corrosion, and damage to electronics from exposure to radioactive materials. The cost of installation of equipment into a glove box (GB) tends to outstrip the cost of the equipment itself. Due to the magnification of cost, the historical approach to equipment installs has been to purchase and install the highest-quality and most robust equipment available to maximize time between failures and updates. To make room for the installation of a new lathe, the inspection GB is being moved to a different location within the machining lab. As part of the overall effort, the equipment within the inspection GB is being revisited. Current measurement capabilities are antiquated and starting to become problematic due to age. Advances in metrology are sought for more comprehensive characterization of scientific samples. This document aims to identify several options for the replacement of current measurement equipment and identify a system for purchase and eventual installation. The intention is not to select the cheapest system, but rather to identify a system that best meets the needs of both the operators and principal investigators (PI). Following the convention of the SYSM-5620 Design Thinking and System Engineering, it was determined that a laser confocal measurement system from Keyence is the most suitable option for our programmatic need. Form factor, capability, and maintainability were considered. Along with stakeholder input, to ensure the best decision for the Nuclear Material Technology Program.

36 MATERIALS SCIENCE↗

Wabash CarbonSAFE. Geologic Analysis of the Potosi Dolomite Reservoir Interval and Potential Confining Units, at the Wabash #1 Well, Vigo Co., Indiana, Subtask 7.2, Technical Report

The Wabash CarbonSAFE project drilled the Wabash #1 stratigraphic test well (ID# 168045) at the Wabash Valley Resources (WVR) IGCC facility in Vigo County, Indiana, to evaluate the feasibility of commercial-scale CO 2 storage near the site. The Mt. Simon Sandstone was the initial target for storage evaluation and was found to have generally poor reservoir qualities in the Wabash #1 well. Focus was then placed on the secondary target, the Potosi Dolomite. For storage and containment evaluation an extensive suite of geophysical logs was collected throughout the borehole, and whole cores were obtained from the Mt. Simon Sandstone, Eau Claire Formation, and Maquoketa Group. The Maquoketa Group is identified as a regionally extensive secondary sealing interval above the Mt. Simon Sandstone and as a primary seal for the Potosi Dolomite storage complex. Due to concerns over potential lost circulation zones in the Potosi Dolomite during drilling, no core samples or Formation Micro Imager (FMI) logs were acquired in the Potosi Dolomite. However, cased hole well testing was performed over a 20 feet (6 m) interval within the Potosi Dolomite during which a fluid swab sample was obtained. Approximately 35 miles of 2D seismic information was acquired in the project area near Wabash #1 to aid in reservoir and caprock characterization. The highly porous and permeable zones in the Potosi Dolomite and lower Oneota Dolomite observed within the Wabash #1 well are, for the purpose of this report, considered the same reservoir package and referred to as the Potosi reservoir interval. This report presents a regional depositional context for the Potosi reservoir interval, the overlying confining zones in the Knox Group, and Maquoketa Group primary seal. This context is developed through detailed information obtained from the Wabash #1 well such as lithologic data collected from cuttings and core, geophysical logging, geomechanical analysis of core samples, and well testing and fluid sampling within the Potosi reservoir interval. Information discussed in this report was compiled as a basis for the development of static and dynamic geologic models of the Potosi Dolomite storage complex. The static and dynamic modeling of CO 2 injection in the Potosi reservoir interval are discussed in a separate report (Dessenberger et al., 2022) under the Wabash CarbonSAFE project.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Progress Update on the In Situ Load Retention Aging Vessel

To improve upon our conventional thermally accelerated aging study methods which require periodic interruption of aging to perform load testing in an Instron machine, a new aging system is being developed to: (1) automate/facilitate data acquisition/analysis, (2) improve data quality, and (3) enable uninterrupted aging conditions (compression, temperature, atmosphere) which represents the service condition. In FY24, a thermal aging vessel instrumented with load cells was fabricated and tested. That unit demonstrated the primary function of the vessel: to continuously monitor the in situ load retention of up to three compressed polymer coupons undergoing thermally accelerated aging under nitrogen. A secondary objective, not realized in the unit due to inadequate sealing, was to enable a single initial nitrogen backfill (as opposed to a continuous purge) and gas sampling of the vessel headspace during thermal aging. Heating of the vessel was achieved using a custom heater jacket.

36 MATERIALS SCIENCE↗