Search NASA⌕ Search

SEARCH · Search NASA

Results for “seawater”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Measurement of the Dielectric Constant of Seawater at L-Band: Techniques and Measurements

Satellite instruments, that will monitor salinity from space in the near future, require an accurate relationship between salinity/temperature and seawater dielectric constant. This paper will review measurements that were made of the dielectric constant of seawater during the past several years. The objective of the measurements is to determine the dependence of the dielectric constant of seawater on salinity and on temperature, more accurately than in the past. by taking advantage of modem instrumentation. The measurements of seawater permittivity have been performed as a function of salinity and temperature using a transmission resonant cavity technique. The measurements have been made in the salinity range of 10 to 38 psu and in the temperature range of IOU C to 35 C. These results will be useful in algorithm development for sensor systems such as SMOS and Aquarius. The measurement system consists of a brass microwave cavity that is resonant at 1.413 GHz. The seawater is introduced into the cavity through a capillary glass tube having an inner diameter of 0.1 mm. The diameter of the tube has been made very small so that the amount of seawater introduced in the cavity is small - thus maintaining the sensitivity of the measurements and allowing the use of perturbation theory predicting the seawater permittivity. The change in resonant frequency and the change in cavity Q can be used to determine the real and imaginary pare of the dielectric constant of seawater introduced into the slender tube. The microwave measurements are made by an HPS722D network analyzer. The cavity has been immersed in a u~ateriethylene-glycol bath which is connected to a Lauda circulator. The circulator keeps the brass cavity at a temperature constant to within 0.01 degrees. The system is automated using a Visual Basic program to control the analyzer and to collect the data. The results of the dielectric constant measurements of seawater will be presented. The measurement results will be compared with permittivity values generated from the Kline and Swift relationship. Two methods of calibration will be discussed, The errors that each technique introduces into the measurement resulls will be reviewed. Temperature stability, frequency drift and the effect of increasing cavity transmission loss on the unloaded cavity Q will also be discussed.

Lang, R.↗

Predicting the Seawater Chemistry of an Ocean World Using Machine Learning on Isotopic Measurements of Volatile CO2

Introduction: Given the long time intervals required for data transmission to and from ocean worlds targets, low bandwidth for data transmission, time required for data processing and analysis, and potentially extreme radiation environments (e.g., Europa), it is clear that ocean worlds missions will need more autonomous flight instruments and software in order to achieve established science goals. Protracted time intervals for data analysis (e.g., Europa Lander) strongly motivates the development of rapid, consistent and streamlined methods for interpreting data from flight mass spectrometers to e.g., determine how mass spectra from a plume or surface liquid/ice relates to the surface/subsurface. Since mass spectrometry also has the potential to correctly identify biosignatures[1], it is imperative that such methods for interpreting data are consistent and accurate. We used 848 isotope ratio mass spectra from laboratory analyses of CO2 that interacted with ocean worlds-relevant seawaters as a ‘training’ dataset for ‘unsupervised’ machine learning. In unsupervised learning, characteristics of the data are not labeled or linked, and any similarities found only result from the neural network. CO2 isotopologues analyzed for this dataset mimic the remote measurements of CO2 by a flight mass spectrometer, and are detailed in Theiling [2]. From this dataset, we used measured features of the spectra, such as retention time, intensity, and (isotopologue) mass ratios as inputs for our autoencoder neural network. Our neural network was trained to find similarities in these and other spectral features for seawaters of a particular composition and amount of initial CO2. Successful training then created an output of these similarities for various seawaters, which included MgSO4, Na2SO4, NaCl, MgCl2, KCl, and NaHCO3, and combinations of these salts. We then applied dimensionality reduction techniques such as Principal Component Analysis (PCA), T-Distributed Stochastic Neighbor Embedding (TSNE), and Uniform Manifold Approximation and Projection (UMAP) to demonstrate latent data features as a two-dimensional projection in a unitless, high-dimensional space. In this projection, a data point represents the combined effect of spectral features such as intensity, retention time, and isotope ratio. Our initial UMAP demonstrates data clustering (organization of the data by the neural network) based on the amount of CO2 that had initially interacted with each seawater. Further training using more ‘supervised’ learning techniques demonstrate strong clustering of preliminary data based on initial CO2 concentration, seawater chemical composition, and ionic strength (salinity). Our preliminary work therefore suggests that machine learning has the potential to identify compositional variants of an ocean world seawater based on mass spectra from volatile CO2 measurements. Acknowledgments: This work was funded through a Strategic Task Group at NASA Goddard Space Flight Center. The training dataset was collected through funding from the Oklahoma Space Grant Consortium. References: [1] Pappalardo, R. et al. (2013) Astrobiology, 13, 740–773. [2] Theiling (2020) Icarus, 114216.

Europa↗

The evaporation path of seawater and the coprecipitation of Br- and K+ with halite

Brines and salt were sampled at the Morton Bahamas solar salt production facility on Great Inagua Island in the Bahamas. The brines were analyzed by ion chromatography to define more precisely than heretofore the evaporation path of seawater to the end of the halite facies. At Inagua, calcium carbonate begins to precipitate at a brine concentration factor of 1.8 times that of seawater. Gypsum begins to precipitate at a brine concentration of 3.8 times seawater, and halite at a concentration factor of 10.6. Three of the most concentrated brines from Inagua (40 times seawater) were evaporated further in the laboratory. Magnesium sulfate first precipitated at brine concentrations about 70 times those of seawater, and potassium-bearing phases began to precipitate for these brines at concentrations greater than 90 times those of seawater. The distribution of coefficients of Br- and K+ between brines and halite were determined by combining analytical data for the Inagua brines with measurements of the Br- and K+ content of halites from Inagua and of halite which had precipitated from Inagua brines during storage. The observed average value of DBr- is 0.032, in good agreement with some of the previous measurements. The measured values of DK+ are highly variable (0.001 to 0.021); DK+ for halite precipitated early in the halite facies is in the vicinity of 0.015.

NASA Discipline Exobiology↗

Green icebergs formed by freezing of organic-rich seawater to the base of Antarctic ice shelves

Samples of Antarctic seawater, basal ice, and green ice from ice cliffs and green icebergs are analyzed in order to examine green icebergs formed by the freezing of organic-rich seawater to the base of Antarctic ice shelves. Spectral reflectance of a green iceberg measured near 67 deg S, 62 deg E confirms that the color is inherent in the ice, not an artifact of the illumination. A constituent that absorbs blue photons is identified by spectrophotometric analysis of core samples from this iceberg and from the Amery basal ice, and of seawater samples from Prydz Bay off the Amery Ice Shelf. Analysis of the samples by fluorescence spectroscopy indicates that the blue absorption, and hence the inherent green color, is due to the presence of marine-derived organic matter in the green iceberg, basal ice, and seawater. Thick accumulations of green ice, in icebergs, and at the base of ice shelves indicate that high concentrations of organic matter exist in seawater for centuries at the depth of basal freezing.

Warren, Stephen G.↗

L-band Dielectric Constant Measurements of Seawater (Oral presentation and SMOS Poster)

This paper describes a resonant cavity technique for the measurement of the dielectric constant of seawater as a function of its salinity. Accurate relationships between salinity and dielectric constant (which determines emissivity) are needed for sensor systems such as SMOS and Aquarius that will monitor salinity from space in the near future. The purpose of the new measurements is to establish the dependence of the dielectric constant of seawater on salinity in contemporary units (e.g. psu) and to take advantage of modern instrumentation to increase the accuracy of these measurements. The measurement device is a brass cylindrical cavity 16cm in diameter and 7cm in height. The seawater is introduced into the cavity through a slender glass tube having an inner diameter of 0.1 mm. By assuming that this small amount of seawater slightly perturbs the internal fields in the cavity, perturbation theory can be employed. A simple formula results relating the real part of the dielectric constant to the change in resonant frequency of the cavity. In a similar manner, the imaginary part of the dielectric constant is related to the change in the cavity s Q. The expected accuracy of the cavity technique is better than 1% for the real part and 1 to 2% for the imaginary part. Presently, measurements of methanol have been made and agree with precision measurements in the literature to within 1% in both real and imaginary parts. Measurements have been made of the dielectric constant of seawater samples from Ocean Scientific in the United Kingdom with salinities of 10, 30, 35 and 38 psu. All measurements were made at room temperature. Plans to make measurements at a range of temperatures and salinities will be discussed.

Lang, Roger H.↗

New Dielectric Measurement Data to Determine the Permittivity of Seawater at 1.4313 Hz

This paper describes the new measurements - made in 2010-2011 - of the dielectric constant of seawater at 1.413 GHz using a resonant cavity technique. The purpose of these measurements is to develop an accurate relationship concerning the dependence of the dielectric constant of seawater on temperature and salinity for use by the Aquarius inversion algorithm. Aquarius is a NASA/CONAE satellite mission launched in June of 2011 with the primary mission of measuring global sea surface salinity with a 1.413 GHz radiometer to an accuracy of 0.2 psu. A brass microwave cavity resonant at 1.413 GHz has been used to measure the dielectric constant of seawater. The seawater is introduced into the cavity through a capillary glass tube having an inner diameter of 0.1 mm. The change of resonant frequency and the cavity Q value are used to determine the real and imaginary parts of the dielectric constant of seawater. Measurements are automated with Visual Basic software developed at the George Washington University. In this paper, new results from measurements made since September 2010 will be presented for salinities of 30, 35 and 38 psu with a temperature range of 0 C to 35 C in intervals of 5 C. These measurements are more accurate than earlier measurements made in 2008. The new results will be compared to the Klein-Swift (KS) and Meissner-Wentz (MW) model functions. The importance of an accurate model function will be illustrated by using these model functions to invert the Aquarius brightness temperature to retrieve the salinity values. The salinity values will be compared to co-located in situ data collected by Argo buoys.

Lang, R.↗

Measurements of the dielectric properties of seawater and NaCl solutions at 2.65 GHz.

Measurements at 2.653 GHz of the dielectric properties of seawater samples collected over the world's oceans and NaCl solutions over the concentration range from 0.3 to 0.7 N have been made over the temperature range from 5.5 to 24 C to an accuracy of 0.2% in the real part of epsilon and 0.4% in the imaginary part of epsilon. The measurements demonstrate that the dielectric properties of seawater can be determined from its chlorinity alone but are substantially different from those of the 3.35 wt % NaCl solution, which has been taken in all previous work as a model for seawater. The data are presented in a form that is well fitted by a linear dependence on chlorinity. The accuracy of the measurements removes the uncertainty in the dielectric properties of seawater as a significant source of error in S-band radiometric determination of ocean surface temperature.

Ho, W.↗

Synthetic seawater as stress-corrosion test medium

Seawater minimizes pitting corrosion of aluminum-alloy test samples. Of three corrosion-inhibiting methods evaluated using (a) chromate inhibitors in saltwater, (b) surface treating sample via anodizing or alodine treatment, and (c) synthetic seawater, synthetic seawater was most effective test medium, since it is more uniform than fresh seawater.

Humphries, T. S.↗

SRB seawater corrosion project

The corrosion behavior of 2219 aluminum when exposed to seawater was characterized. Controlled corrosion experiments at three different temperatures (30, 60 and 100 C) and two different environments (seawater and 3.5 percent salt solution) were designed to elucidate the initial stages in the corrosion process. It was found that 2219 aluminum is an active catalytic surface for growth of Al2O3, NaCl, and MgO. Formation of Al2O3 is favored at lower temperatures, while MgO is favored at higher temperatures. Visible corrosion products are formed within 30 minutes after seawater exposure. Corrosion characteristics in 3.5 percent salt solution are different than corrosion in seawater. Techniques utilized were: (1) scanning electron microscopy, (2) energy dispersive x-ray spectroscopy, and (3) Auger electron spectroscopy.

Bozack, M. J.↗

Increased Accuracy in the Measurement of the Dielectric Constant of Seawater at 1.413 GHz

This paper describes the latest results for the measurements of the dielectric constant at 1.413 GHz by using a resonant cavity technique. The purpose of these measurements is to develop an accurate relationship for the dependence of the dielectric constant of sea water on temperature and salinity which is needed by the Aquarius inversion algorithm to retrieve salinity. Aquarius is the major instrument on the Aquarius/SAC-D observatory, a NASA/CONAE satellite mission launched in June of20ll with the primary mission of measuring global sea surface salinity to an accuracy of 0.2 psu. Aquarius measures salinity with a 1.413 GHz radiometer and uses a scatterometer to compensate for the effects of surface roughness. The core part of the seawater dielectric constant measurement system is a brass microwave cavity that is resonant at 1.413 GHz. The seawater is introduced into the cavity through a capillary glass tube having an inner diameter of 0.1 mm. The change of resonance frequency and the cavity Q value are used to determine the real and imaginary parts of the dielectric constant of seawater introduced into the thin tube. Measurements are automated with the help of software developed at the George Washington University. In this talk, new results from measurements made since September 2010 will be presented for salinities 30, 35 and 38 psu with a temperature range of O C to 350 C in intervals of 5 C. These measurements are more accurate than earlier measurements made in 2008 because of a new method for measuring the calibration constant using methanol. In addition, the variance of repeated seawater measurements has been reduced by letting the system stabilize overnight between temperature changes. The new results are compared to the Kline Swift and Meissner Wentz model functions. The importance of an accurate model function will be illustrated by using these model functions to invert the Aquarius brightness temperature to get the salinity values. The salinity values will be compared to co-located in situ data collected by Argo buoys.

Zhou, Y.↗

A Cavity System for Seawater Dielectric Measurements at P-Band

This paper describes a new system for measuring the dielectric constant of seawater near 700 MHz. The purpose of this research is to obtain data at P-band for the dielectric constant of seawater that can be combined with previous L-band data for developing a model function valid from 500 MHz to 2000 MHz. A transmission-type cylindrical cavity has been constructed with the TM010 mode resonance occurring near 700 MHz. The seawater is introduced via a capillary quartz tube. The dimensions of the cavity have been determined by electromagnetic modelling. The model takes the cavity wall loss into account and can provide accurate estimation of resonance condition for both the empty cavity and cavity with seawater. The errors between the theory and measurement are about 0.07% for the resonant frequency and 0.4% for the quality factor, Q. The cavity design, experimental setup and measurement schedule will be presented in the paper.

Roger Lang↗

Accurate Measurements of the Dielectric Constant of Seawater at L Band

This paper describes measurements of the dielectric constant of seawater at a frequency of 1.413 GHz, the center of the protected band (i.e., passive use only) used in the measurement of sea surface salinity from space. The objective of the measurements is to accurately determine the complex dielectric constant of seawater as a function of salinity and temperature. A resonant cylindrical microwave cavity in transmission mode has been employed to make the measurements. The measurements are made using standard seawater at salinities of 30, 33, 35, and 38 practical salinity units over a range of temperatures from 0 degree C to 35 degree C in 5 degree C intervals. Repeated measurements have been made at each temperature and salinity. Mean values and standard deviations are then computed. The total error budget indicates that the real and imaginary parts of the dielectric constant have a combined standard uncertainty of about 0.3 over the range of salinities and temperatures considered. The measurements are compared with the dielectric constants obtained from the model functions of Klein and Swift and those of Meissner and Wentz. The biggest differences occur at low and high temperatures.

Measurements↗

Seawater Debye Model Function at L-Band and Its Impact on Salinity Retrieval From Aquarius Satellite Data

A model function of seawater, which specifies the dielectric constant of seawater as a function of salinity, temperature, and frequency, is important for the retrieval of sea surface salinity using satellite data. In 2017, a model function has been developed based on measurement data at 1.4134 GHz using a third-order polynomial expression in salinity ( S ) and temperature ( T ). Although the model showed improvements in salinity retrieval, it had an inconsistent behavior between partitioned salinities. To improve the stability of the model, new dielectric measurements of seawater have been made recently over a broad range of salinities and temperatures to expand the data set used for developing the model function. The structure of the model function has been changed from a polynomial expansion in S and T to a physics-based model consisting of a Debye molecular resonance term plus a conductivity term. Each unknown parameter is expressed in S and T based on the expanded measurement data set. Physical arguments have been used to limit the number of unknown coefficients in these expressions to improve the stability of the model function. The new model function has been employed in the retrieval algorithm of the Aquarius satellite mission to obtain a global salinity map. The retrieved salinity using a different model function is compared with in situ data collected by Argo floats to evaluate the impact and the performance of model functions. The results indicate that the new model function has significant improvements in salinity retrieval compared with other existing models.

Seawater↗

Effects of seawater and deionized water at 0 to 80 deg C on the flexural properties of a glass/epoxy composite

The effect on the flexural properties of a glass/epoxy composite of immersion in deionized water or seawater at 0, 25, and 80 C for 451 hr was examined. The percent weight gain at 0 and 25 C was low (0.06 to 0.17 percent) and there was no significant change in the flexural properties for these environmental conditions. At 80 C there was a decrease in the flexural strength of 17 and 20 percent in seawater and deionized water, respectively. This is a comparison to control samples exposed to 80 C heat alone. These decreases were found to be nearly reversible once the samples were dried. Optical microscopy did not reveal cracking of the matrix. The flexural modulus was essentially unaffected by exposure to deionized water and seawater at 80 C.

Penn, B. G.↗

Strontium isotopic variations of Neoproterozoic seawater - Implications for crustal evolution

High-precision Sr isotopic data were obtained on carbonate samples from the Neoproterozoic Shaler Group, Victoria Island (Canada). Results indicate that, between ca. 790 and 850 Ma, the Sr-87/Sr-86 ratio of seawater varied betweeen 0.70676 and 0.70561, with the minimum value at about 830 Ma. A curve of the Sr-87/Sr-86 seawater ratio vs. age showed that the new data substantially improve the existing isotopic record of Sr in seawater for the period 790-850 Ma. The Sr isotopic system data were coupled with data for the Nd isotopic system to model changes in the seafloor spreading rates (hydrothermal flux) and the continental erosion for the period 500-900 Ma. Results indicate that hydrothermal flux reached a maximum value at ca. 830 Ma, while a maximum in erosion rate occurred at ca. 570 Ma. These peaks are considered to be related to the developments in the Pan-African and related orogenic events.

Asmerom, Yemane↗

Accurate Measurements of the Dielectric Constant of Seawater at L Band

This report describes measurements of the dielectric constant of seawater at a frequency of 1.413 GHz that is at the center of the L-Sand radiometric protected frequency spectrum. Aquarius will be sensing the sea surface salinity from space in this band. The objective of the project is to refine the model function for the dielectric constant as a function of salinity and temperature so that remote sensing measurements can be made with the accuracy needed to meet the measurement goals (0.2 psu) of the Aquarius mission. The measurements were made, using a microwave cavity operated in the transmission configuration. The cavity's temperature was accurately regulated to 0.02 C by immersing it in a temperature controlled bath of distilled water and ethanol glycol. Seawater had been purchased from Ocean Scientific International Limited (OS1L) at salinities of 30, 35 and 38 psu. Measurements of these seawater samples were then made over a range of temperatures, from l0 C to 35 C in 5 C intervals. Repeated measurements were made at each temperature and salinity, Mean values and standard deviations were then computed. Total error budgets indicated that the real and imaginary parts of the dielectric constant had a relative accuracy of about l%.

Lang, Roger H.↗

Retrieving Marine Inherent Optical Properties from Satellites Using Temperature and Salinity-dependent Backscattering by Seawater

Time-series of marine inherent optical properties (IOPs) from ocean color satellite instruments provide valuable data records for studying long-term time changes in ocean ecosystems. Semi-analytical algorithms (SAAs) provide a common method for estimating IOPs from radiometric measurements of the marine light field. Most SAAs assign constant spectral values for seawater absorption and backscattering, assume spectral shape functions of the remaining constituent absorption and scattering components (e.g., phytoplankton, non-algal particles, and colored dissolved organic matter), and retrieve the magnitudes of each remaining constituent required to match the spectral distribution of measured radiances. Here, we explore the use of temperature- and salinity-dependent values for seawater backscattering in lieu of the constant spectrum currently employed by most SAAs. Our results suggest that use of temperature- and salinity-dependent seawater spectra elevate the SAA-derived particle backscattering, reduce the non-algal particles plus colored dissolved organic matter absorption, and leave the derived absorption by phytoplankton unchanged.

Passive Remote Sensing↗

Debye Dielectric Model Function for Seawater Based on Expanded L-Band Measurement Data Set

New seawater dielectric measurements have recently been made over a broad range of salinities and temperatures at the George Washington University (GW). These measurements have been used to refine the existing dielectric model function of seawater for salinity retrieval. The mathematical structure of the new model function has been investigated to: (a) look for a physical basis for the mathematical form; and (b) to optimize the accuracy of data fitting. The Debye model has been chosen to represent the dielectric constant of seawater as a function of salinity (S), temperature (T) and frequency (f). The retrieved salinity using the Debye model has good agreement with the in-situ data collected by Argo floats. The global differences in retrieved salinity and in-situ data will be presented at the meeting.

ocean salinity↗