Search NASA⌕ Search

SEARCH · Search NASA

Results for “second harmonic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Improved Efficiency Type II Second Harmonic Generation

Second harmonic efficiency is limited by lateral and temporal separation of the ordinary and extraordinary components of the fundamental. A mode locked dual beam laser demonstrated these effects and a novel method to minimize them.

Barnes, Norman P.↗

Solitons and second harmonic radiation in type III bursts

The emission at the second harmonic of the plasma frequency from self-consistent Langmuir solitons is calculated. The theory predicts, in a natural way, the observed transition from the region where the intensity is linearly proportional to the electron flux to the region where the radio intensity is proportional to the square of the electron flux. A detailed comparison of the radiation observed at the second harmonic for the burst of 18:10 UT March 31, 1976, with the one expected on the assumption of radiation from solitons, using the correlated in situ measurements of the electric fields at the second harmonic, and their spatial structure, provides strong evidence that, for the first time, Langmuir solitons have been observed in space.

Papadopoulos, K.↗

Emissions of second-harmonic auroral kilometric radiation

The cyclotron maser theory of Wu and Lee (1979) is used in treating second-harmonic auroral kilometric radiation (AKR). Good agreement is obtained with the ISIS 1 observation reported by Benson (1982). It is found that when the ratio of the electron plasma frequency to the electron gyrofrequency is less than 0.3, the fundamental AKR prevails over the second-harmonic AKR. When the value of this ratio is greater than or approximately equal to 0.3, the fundamental AKR may become weaker than the second-harmonic AKR, and when it is greater than 0.3 the fundamental AKR may diminish. It is also found that the second harmonic AKR with frequencies below twice the electron gyro-frequency can propagate downward.

Wu, C. S.↗

Organometallic Salts Generate Optical Second Harmonics

Series of organometallic salts exhibit large second-order dielectric susceptibilities, as evidenced by generation of second harmonics when illuminated at visible and near-infrared wavelengths. Investigations of these and related compounds continue with view toward development of materials for use as optical second-harmonic generators, electro-optical modulators, optical switches, piezoelectric sensors, and parametric crystals.

Marder, Seth R.↗

Corrected formula for the polarization of second harmonic plasma emission

Corrections for the theory of polarization of second harmonic plasma emission are proposed. The nontransversality of the magnetoionic waves was not taken into account correctly and is here corrected. The corrected and uncorrected results are compared for two simple cases of parallel and isotropic distributions of Langmuir waves. It is found that whereas with the uncorrected formula plausible values of the coronal magnetic fields were obtained from the observed polarization of the second harmonic, the present results imply fields which are stronger by a factor of three to four.

Melrose, D. B.↗

Second Harmonic Hectometric Radio Emission at Jupiter

Galileo has been in orbit around Jupiter since December 1995. The plasma wave instrument on board the spacecraft has occasionally detected a rotationally modulated attenuation band in the hectometric (HOM) emission that most likely is due to scattering of the radiation from density fluctuations along the Io L-shell, as reported earlier. The occurrence of the attenuation band is likely to be dependent on Io activity and the presence of density scattering centers along the Io L-shell as well as the location of the source region. Some of the attenuation bands show clear indications of second harmonic emission. Without polarization measurements, it is difficult to place constraints on the local generation conditions based on the cyclotron maser instability, but the results imply that second harmonic emission could be present in the decametric (DAM) radiation as well. A survey of the data has revealed about 30 examples of second harmonic HOM.

Menietti, J. D.↗

Second Harmonic Hectometric Radio Emission at Jupiter

Galileo has been in orbit around Jupiter since December 1995. The plasma wave instrument on board the spacecraft has occasionally detected a rotationally modulated attenuation band in the hectometric (HOM) emission that most likely is due to scattering of the radiation from density fluctuations along the Io L-shell, as reported earlier. The occurrence of the attenuation band is likely to be dependent on Io activity and the presence of density scattering centers along the Io-L-shell as well as the location of the source region. Some of the attenuation bands show clear indications of second harmonic emission. Without polarization measurements, it is difficult to place constraints on the local generation conditions based on the cyclotron maser instability, but the results imply that second harmonic emission could be present in the decametric (DAM) radiation as well. A survey of the data has revealed about 30 examples of second harmonic HOM.

Menietti, J. D.↗

Second Harmonic Imaging improves Echocardiograph Quality on board the International Space Station

Ultrasound (US) capabilities have been part of the Human Research Facility (HRF) on board the International Space Station (ISS) since 2001. The US equipment on board the ISS includes a first-generation Tissue Harmonic Imaging (THI) option. Harmonic imaging (HI) is the second harmonic response of the tissue to the ultrasound beam and produces robust tissue detail and signal. Since this is a first-generation THI, there are inherent limitations in tissue penetration. As a breakthrough technology, HI extensively advanced the field of ultrasound. In cardiac applications, it drastically improves endocardial border detection and has become a common imaging modality. U.S. images were captured and stored as JPEG stills from the ISS video downlink. US images with and without harmonic imaging option were randomized and provided to volunteers without medical education or US skills for identification of endocardial border. The results were processed and analyzed using applicable statistical calculations. The measurements in US images using HI improved measurement consistency and reproducibility among observers when compared to fundamental imaging. HI has been embraced by the imaging community at large as it improves the quality and data validity of US studies, especially in difficult-to-image cases. Even with the limitations of the first generation THI, HI improved the quality and measurability of many of the downlinked images from the ISS and should be an option utilized with cardiac imaging on board the ISS in all future space missions.

Garcia, Kathleen↗

Synchronous pumping of picosecond dye laser using high efficiency second harmonic generation from optical fibres

The stable operation of a mode-locked dye laser synchronously pumped by the second harmonic of an Nd:YAG laser produced in an Nd codoped germanosilicate optical fiber is reported. The optical fiber preparation technique, which results in a second harmonic conversion efficiency of 2 percent, is described. This optical fiber SHG conversion efficiency is the highest reported to date using a continuous-wave mode-locked laser.

Lawandy, N. M.↗

Efficient second-harmonic conversion of CW single-frequency Nd:YAG laser light by frequency locking to a monolithic ring frequency doubler

Efficient second-harmonic conversion of the 1064-nm output of a diode-pumped CW single-frequency Nd:YAG laser to 532 nm was obtained by frequency locking the laser to a monolithic ring resonator constructed of magnesium-oxide-doped lithium niobate. The conversion efficiency from the fundamental to the second harmonic was 65 percent. Two hundred milliwatts of CW single-frequency 532-nm light were produced from 310 mW of power of 1064-nm light. This represents a conversion efficiency of 20 percent from the 1-W diode laser used to pump the Nd:YAG laser to single-frequency 532-nm output. No signs of degradation were observed for over 500 h of operation.

Gerstenberger, D. C.↗

The polarization of second harmonic plasma emission

It is shown that second-harmonic plasma emission is partially polarized in the sense of the ordinary mode of magnetoionic theory only when the Langmuir waves are confined to a small range of angles (less than 30 deg) to the magnetic-field lines. Consequently, Suzuki and Sheridan's (1977) observations of the polarization of harmonic Type III emission implies that (at least in the cases reported) the Langmuir waves must be nearly one-dimensional. For a nearly one-dimensional distribution, the degree of polarization and the frequency of observation should be related to the magnetic field. For the observed polarization of Type III bursts, the implied magnetic-field strengths are strong enough for induced scattering to cause the Langmuir waves to become nearly one-dimensional, which is consistent with the observed sense of polarization. In other applications of harmonic plasma emission where the Langmuir waves might be isotropic or in a loss-cone distribution, polarization in the sense of the extraordinary mode is predicted.

Melrose, D. B.↗

Phase matching in second-harmonic generation using artificial periodic structures.

The use of artificial periodic structures, consisting of spatial modulations of the linear and nonlinear susceptibilities of a nonlinear optical medium, to achieve phase matching in second-harmonic generation is analyzed. Dispersion relations and approximate formulas for the second-harmonic fields generated under various conditions are obtained and used to evaluate the experimental situation.

Tang, C. L.↗

The prevalence of second harmonic radiation in type III bursts observed at kilometric wavelengths.

We present the analysis of 64 type III solar bursts that drifted from 3.5 MHz down to the range 350-50 kHz between March 1968 and February 1970. Bursts arrival times were predicted by a simple model and then compared with observations. The results show that, as the bursts drift, the fundamental often disappears below a certain frequency range while the second harmonic remains. Below about 1 MHz, the second harmonic occurrence predominates. Recognizing this fact we deduce a mean velocity of 0.32c plus or minus 0.02c for the exciter particles, where the uncertainty is the standard error and c the velocity of light in vacuum; the electron density model used is comparable to a solar wind model.

Haddock, F. T.↗

Possible second harmonic gyroemission at Uranus

During the inbound trajectory toward Uranus, the Planetary Radio Astronomy Instrument on board the Voyager 2 spacecraft observed narrow-band smooth (n-smooth) emission at frequencies centered near 60 kHz. By assuming models of the plasma density for the dayside magnetosphere of Uranus and by using cold plasma theory together with stringent observational constraints, ray-tracing calculations were performed to determine the source location and mode of the n-smooth emission. Ray-tracing calculations suggest that the n-smooth emission with sources near the magnetic equator may be fundamental X mode for certain conditions or second harmonic gyroemission. If the emission is second harmonic gyroemission, the fundamental emission at 30 kHz is expected but apparently not observed. These findings are discussed in the context of the most recent developments in the theory of the cyclotron maser instability.

Menietti, J. D.↗