Search NASA⌕ Search

SEARCH · Search NASA

Results for “segmented detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Multi-segment detector

A plurality of stretcher detector segments are connected in series whereby detector signals generated when a bubble passes thereby are added together. Each of the stretcher detector segments is disposed an identical propagation distance away from passive replicators wherein bubbles are replicated from a propagation path and applied, simultaneously, to the stretcher detector segments. The stretcher detector segments are arranged to include both dummy and active portions thereof which are arranged to permit the geometry of both the dummy and active portions of the segment to be substantially matched.

George, Peter K.↗

Super-Resolution Ptychography with Small Segmented Detectors

To overcome the spatial resolution limit set by aperture-limited diffraction in traditional scanning transmission electron microscopy, microscopists have developed ptychography enabled by iterative phase retrieval algorithms and high-dynamic-range pixel array detectors. Current detector designs are limited by the data rate off chip, so a high-pixel-count detector has a proportionally lower frame rate than the few-segment detectors used for differential phase contrast (DPC) imaging. This slower acquisition speed leads to heightened vulnerability to scan noise, drift, and potential sample damage. This creates opportunities for repurposing fast segmented detectors for ptychography by trading a reduction in reciprocal space pixels for an increase in real space pixels. Here, we explore a strategy of oversampling in real space and instead apply detector pixel upsampling during the reconstruction process. Further, we demonstrate the viability of achieving super-resolution ptychography on thin objects using only 2 × 2 detector pixels, surpassing the resolution of integrated DPC (iDPC) imaging. With optimization using simulated datasets and experiments on MoTe 2 /WSe 2 bilayer moiré superlattices, we achieved super-resolution ptychography reconstructions under rapid acquisition conditions (37.5 pA, 1 μs dwell time), yielding over 50% improvements in contrast and information limit compared to annular dark field and iDPC imaging on the same detectors.

2D materials↗

Segmented Detector for Cosmic Gamma Rays

Segmented structure distinguishes gamma rays of cosmic origin from internal radioactivity. Preamplifier and discriminator channel connects each electrically independent segment of gamma-ray detector to logic circuitry. Logic compares and analyzes events in segments to determine sources. According to Monte Carlo calculations, sensitivity of detector two to three times better than conventional detectors because background interactions discerned and eliminated.

Varnell, L. S.↗

High-resolution imaging gamma-ray spectroscopy with externally segmented germanium detectors

Externally segmented germanium detectors promise a breakthrough in gamma-ray imaging capabilities while retaining the superb energy resolution of germanium spectrometers. An angular resolution of 0.2 deg becomes practical by combining position-sensitive germanium detectors having a segment thickness of a few millimeters with a one-dimensional coded aperture located about a meter from the detectors. Correspondingly higher angular resolutions are possible with larger separations between the detectors and the coded aperture. Two-dimensional images can be obtained by rotating the instrument. Although the basic concept is similar to optical or X-ray coded-aperture imaging techniques, several complicating effects arise because of the penetrating nature of gamma rays. The complications include partial transmission through the coded aperture elements, Compton scattering in the germanium detectors, and high background count rates. Extensive electron-photon Monte Carlo modeling of a realistic detector/coded-aperture/collimator system has been performed. Results show that these complicating effects can be characterized and accounted for with no significant loss in instrument sensitivity.

Callas, J. L.↗

Segmented Ge detector rejection of internal beta activity produced by neutron irradiation

Future Ge spectrometers flown in space to observe cosmic gamma-ray sources will incorporate segmented detectors to reduce the background from radioactivity produced by energetic particle reactions. To demonstrate the effectiveness of a segmented Ge detector in rejecting background events due to the beta decay of internal radioactivity, a laboratory experiment has been carried out in which radioactivity was produced in the detector by neutron irradiation. A Cf-252 source of neutrons was used to produce, by neutron capture on Ge-74 (36.5 percent of natural Ge) in the detector itself, Ge-75 (t sub 1/2 = 82.78 min), which decays by beta emission with a maximum electron kinetic energy of 1188 keV. By requiring that an ionizing event deposit energy in two or more of the five segments of the detector, each about 1-cm thick, the beta particles, which have a range of about 1-mm, are rejected, while most external gamma rays incident on the detector are counted. Analysis of this experiment indicates that over 85 percent of the beta events from the decay of Ge-75 are rejected, which is in good agreement with Monte Carlo calculations.

Varnell, L. S.↗

NuSD: A Geant4 based simulation framework for segmented anti-neutrino detectors

NuSD: Neutrino Segmented Detector is a Geant4-based user application that simulates inverse beta decay event in a variety of segmented scintillation detectors developed by different international collaborations. This simulation framework uses a combination of cross-programs and libraries including Geant4, ROOT and CLHEP developed and used by high energy physics community. It will enable the neutrino physics community to simulate and study neutrino interactions within different detector concepts using a single program. In addition to neutrino simulations in segmented detectors, this program can also be used for various research projects that use of scintillation detectors for different physics purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Segmented Ge detectors and mechanical coolers for future gamma-ray astronomy instruments

The effectiveness of a segmented Ge detector in rejecting background events due to the beta decay of internal radioactivity is demonstrated by a laboratory experiment in which radioactivity was produced in the detector by neutron irradiation. A Cf-252 source of neutrons was used to produce, by neutron capture on Ge-74 in the detector itself, Ge-75, which decays by beta emission with a maximum energy of 1188 keV. Simultaneous spectra are taken of the activity in the detector under two conditions: a free spectrum in which all events in the detector are accumulated, and a gated spectrum in which events are accumulated only if they deposit energy in two or more segments. A comparison of the spectra shows that over 85 percent of the beta events are rejected, which is in good agreement with predictions.

Varnell, Larry S.↗

Reconstruction of fast neutron direction in segmented organic detectors using deep learning

A method for reconstructing the direction of a fast neutron source using a segmented organic scintillator-based detector and deep learning model is proposed and analyzed. Here, the model is based on recurrent neural network, which can be trained by a sequence of data obtained from an event recorded in the detector and suitably pre-processed. The performance of deep learning-based model is compared with the conventional double-scatter detection algorithm in reconstructing the direction of a fast neutron source. With the deep learning model, the uncertainty in source direction of 0.301 rad is achieved with 100 neutron detection events in a segmented cubic organic scintillator detector with a side length of 46 mm. To reconstruct the source direction with the same angular resolution as the double-scatter algorithm, the deep learning method requires 75% fewer events. Application of this method could augment the operation of segmented detectors operated in the neutron scatter camera configuration for applications such as special nuclear material detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SANDD: A directional antineutrino detector with segmented 6 Li-doped pulse-shape-sensitive plastic scintillator

We present a characterization of a small (9-liter) and mobile 0.1% 6 Li-doped pulse-shape-sensitive plastic scintillator antineutrino detector called SANDD (Segmented AntiNeutrino Directional Detector), constructed for the purpose of near-field reactor monitoring with sensitivity to antineutrino direction. SANDD comprises three different types of module. A detailed Monte Carlo simulation code was developed to match and validate the performance of each of the three modules. The combined model was then used to produce a prediction of the performance of the entire detector. Analysis cuts were established to isolate antineutrino inverse beta decay events while rejecting large fraction of backgrounds. The neutron and positron detection efficiencies are estimated to be 34.8% and 80.2%, respectively, while the coincidence detection efficiency is estimated to be 71.7%, resulting in inverse beta decay detection efficiency of 20.0% ± 0.2%(stat.) ± 2.1%(syst.). Finally, the predicted directional sensitivity of SANDD produces an uncertainty of 20° in the azimuthal direction per 100 detected antineutrino events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electronic considerations for externally segmented germanium detectors

The dominant background source for germanium gamma ray detector spectrometers used for some astrophysics observations is internal beta decay. Externally segmented germanium gamma ray coaxial detectors can identify beta decay by localizing the event. Energetic gamma rays interact in the germanium detector by multiple Compton interactions while beta decay is a local process. In order to recognize the difference between gamma rays and beta decay events, the external electrode (outside of detector) is electrically partitioned. The instrumentation of these external segments and the consequence with respect to the spectrometer energy signal is examined.

Madden, N. W.↗

High-Resolution Gamma-Ray Imaging Measurements Using Externally Segmented Germanium Detectors

Fully two-dimensional gamma-ray imaging with simultaneous high-resolution spectroscopy has been demonstrated using an externally segmented germanium sensor. The system employs a single high-purity coaxial detector with its outer electrode segmented into 5 distinct charge collection regions and a lead coded aperture with a uniformly redundant array (URA) pattern. A series of one-dimensional responses was collected around 511 keV while the system was rotated in steps through 180 degrees. A non-negative, linear least-squares algorithm was then employed to reconstruct a 2-dimensional image. Corrections for multiple scattering in the detector, and the finite distance of source and detector are made in the reconstruction process.

spectroscopy gamma ray germanium sensor nucleosynt↗

3D Backscatter Imaging System

Systems and methods for imaging an object using backscattered radiation are described. The imaging system comprises both a radiation source for irradiating an object that is rotationally movable about the object, and a detector for detecting backscattered radiation from the object that can be disposed on substantially the same side of the object as the source and which can be rotationally movable about the object. The detector can be separated into multiple detector segments with each segment having a single line of sight projection through the object and so detects radiation along that line of sight. Thus, each detector segment can isolate the desired component of the backscattered radiation. By moving independently of each other about the object, the source and detector can collect multiple images of the object at different angles of rotation and generate a three dimensional reconstruction of the object. Other embodiments are described.

Turner, D. Clark↗

Spectral Peak Enhancement by Combining Trusted Response Elements via Machine Learning (SPECTRE-ML) v0.8.0

SPECTRE-ML (Spectral Peak Enhancement by Combining Trusted Response Elements via Machine Learning) is a machine learning based program for finding optimal clusters of radiation detector segments (i.e., pixels or voxels) in order to improve spectral performance. It provides facilities for pre-processing and analyzing training datasets, running ML algorithms, and evaluating and visualizing outputs. SPECTRE-ML outperforms simpler ad-hoc segmentation methods such as uniform depth clusters, learning detector performance trends such as dead layers, edge effects, and gain shifts. Although extensible to arbitrary highly-segmented spectroscopic radiation detectors, SPECTRE-ML currently focuses on improving spectral performance in highly-segmented CdZnTe (CZT) detectors for International Atomic Energy Agency (IAEA) non-destructive assay (NDA) safeguards tasks.

Vavrek, Jayson↗

Gamma-ray imaging with germanium detectors

Externally segmented germanium detectors promise a breakthrough in gamma-ray imaging capabilities while retaining the superb energy resolution of germanium spectrometers. By combining existing position-sensitive detectors with an appropriate code aperture, two-dimensional imaging with 0.2-deg angular resolution becomes practical for a typical balloon experiment. Much finer resolutions are possible with larger separations between detectors and the coded aperture as would be applicable for space-based or lunar-based observatories. Two coaxial germanium detectors divided into five external segments have been fabricated and have undergone extensive performance evaluation and imaging testing in our laboratory. These tests together with detailed Monte Carlo modeling calculations have demonstrated the great promise of this sensor technology for future gamma-ray missions.

Mahoney, W. A.↗

Ionization-based search for magnetic monopoles using the NOvA Far Detector

We report a search for highly ionizing magnetic monopoles in the cosmic-ray flux using a 2713-day dataset collected during 2015–2025 with the NOvA Far Detector, a 14-kt segmented detector located on Earth’s surface in Minnesota, United States. The search is sensitive to monopoles across a wide range of speeds, 7 × 10 −4 < 𝛽 < 0.995, and is sensitive to masses as low as 2 × 10 5 GeV for the fastest monopoles. No signal was observed. With the detector’s large surface area and minimal overburden, we achieve the strongest flux limits reported to date in several regions of speed and mass. For heavy monopoles with masses above 10 13 GeV that are able to reach the detector from above or—crossing Earth—from below, we find a flux limit 𝜙 90% < 2 × 10 −16 cm −2 s −1 sr −1 (90% confidence level) for monopoles with 0.005 < 𝛽 < 0.8. Across the same range of speeds, we report a limit 𝜙 90% < 8 × 10 −16 cm −2 s −1 sr −1 for light monopoles with masses above 10 8 GeV that can reach the detector from above.

magnetic monopoles↗