Search NASA⌕ Search

SEARCH · Search NASA

Results for “self-ion implantation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Nanoscale lattice strains in self-ion implanted tungsten

Developing a comprehensive understanding of the modification of material properties by neutron irradiation is important for the design of future fission and fusion power reactors. Self-ion implantation is commonly used to mimic neutron irradiation damage, however an interesting question concerns the effect of ion energy on the resulting damage structures. The reduction in the thickness of the implanted layer as the implantation energy is reduced results in the significant quandary: Does one attempt to match the primary knock-on atom energy produced during neutron irradiation or implant at a much higher energy, such that a thicker damage layer is produced? In this work, we address this question by measuring the full strain tensor for two ion implantation energies, 2 MeV and 20 MeV in self-ion implanted tungsten, a critical material for the first wall and divertor of fusion reactors. A comparison of 2 MeV and 20 MeV implanted samples is shown to result in similar lattice swelling. Multi-reflection Bragg coherent diffractive imaging (MBCDI) shows that implantation induced strain is in fact heterogeneous at the nanoscale, suggesting that there is a non-uniform distribution of defects, an observation that is not fully captured by micro-beam Laue diffraction. At the surface, MBCDI and high-resolution electron back-scattered diffraction (HR-EBSD) strain measurements agree quite well in terms of this clustering/non-uniformity of the strain distribution. However, MBCDI reveals that the heterogeneity at greater depths in the sample is much larger than at the surface. This combination of techniques provides a powerful method for detailed investigation of the microstructural damage caused by ion bombardment, and more generally of strain related phenomena in micro-volumes that are inaccessible via any other technique.

36 MATERIALS SCIENCE↗

Thermal diffusivity recovery and defect annealing kinetics of self-ion implanted tungsten probed by insitu transient grating spectroscopy

Tungsten is a promising candidate material for plasma-facing armour components in future fusion reactors. A key concern is irradiation-induced degradation of its normally excellent thermal transport properties. In this comprehensive study, thermal diffusivity degradation in ion-implanted tungsten and its evolution from room temperature (RT) to 1073 K is considered. Five samples were exposed to 20 MeV self-ions at RT to achieve damage levels ranging from 3.2 x 10 -4 to 3.2 displacements per atom (dpa). Transient grating spectroscopy with in-situ heating was then used to study thermal diffusivity evolution as a function of temperature. Using a kinetic theory model, an equivalent point defect density is estimated from the measured thermal diffusivity. The results showed a prominent recovery of thermal diffusivity between 450 K and 650 K, which coincides with the onset of mono-vacancy mobility. After 1073 K annealing samples with initial damage of 3.2 x 10 -3 dpa or less recover close to the pristine value of thermal diffusivity. For doses of 3.2 x 10 -2 dpa or higher, on the other hand, a residual reduction in thermal diffusivity remains even after 1073 K annealing. Transmission electron microscopy reveals that this is associated with extended, irradiation-induced dislocation structures that are retained after annealing. A sensitivity analysis shows that thermal diffusivity provides an efficient tool for the assessing total defect content in tungsten up to 1000 K.

36 MATERIALS SCIENCE↗

Helium causing disappearance of a/2<111> dislocation loops in binary Fe-Cr ferritic alloys

In this work, single and dual-beam self-ion irradiations were performed at 500°C on ultra-high purity Fe14%Cr alloy to ~0.33 displacements-per-atom (dpa), and 0 or 3030 atomic-parts-per-million (appm) helium/dpa, respectively. Using transmission electron microscopy, we reveal that helium can drastically modify the dislocation loop Burgers vector in Fe-Cr alloys. Helium co-implantation caused complete disappearance of a/2<111> type dislocation loops, and the microstructure consisted of only a<100> loops. Conversely, a/2<111> type loops were predominant without He co-implantation. The total loop density remained largely unaffected. The results strikingly contrast literature asserting that helium stabilizes a/2<111> type loops in bcc Fe alloys, based on low temperature irradiations. Collectively analyzing the results with literature suggest that the small positive interaction between helium and self-interstitial atoms (SIA) in Fe predicted by atomistic simulations maybe insufficient to holistically explain the dislocation loop microstructure development in presence of helium. Helium-SIA positive binding inadvertently implies elevated a/2<111> loop fraction and higher loop densities that the present results contradict. Helium induced high cavity density causing a preferential loss of highly glissile <111> clusters, leaving the matrix saturated with <100> type clusters is proposed as a potential mechanism. Further, the in-situ irradiations combined with Burgers vector analysis strengthened the evidence of Cr-induced dislocation loop mobility reduction that appears to stabilize the a/2<111> type loops and causes higher loop densities in Fe-Cr alloys.

36 MATERIALS SCIENCE↗

Novel effects of grain size and ion implantation on grain boundary segregation in ion irradiated austenitic steel

Nuclear reactor environments are extreme in nature due to the combination of exposure to corrosive coolant, mechanical stresses, and neutron irradiation damage. This combination of environments can lead to irradiation induced/assisted precipitation, segregation, and embrittlement coupled with enhanced creep and stress corrosion cracking. While nanostructured materials are of interest in a variety of applications due to their unique properties including high mechanical strength, for nuclear applications nanostructured materials have the added benefit of irradiation resistance due to the high volume density of sinks for irradiation-induced defects. In this study, we show unique radiation-induced segregation (RIS) behavior in nanocrystalline 304 stainless steel (SS304). Typical RIS in austenitic steels includes Ni enrichment and Cr depletion within the grain boundaries. In nanostructured SS304 this RIS is reduced. Furthermore, interestingly, some grain boundaries in the nanocrystalline SS304 in this study were found to be enriched in Cr after Fe 2+ ion irradiation at 500 °C up to 50 displacements per atom (dpa). To understand this unique observation, lattice-based atomic kinetic Monte Carlo simulations were performed to investigate the effects of grain size, thermal segregation, as well as injected interstitials (introduced as Fe self-ions). The results indicate that the Cr enrichment at grain boundaries may be caused by combined effects of grain size, self-ion injection and preferential Cr diffusion via the interstitial mechanism. In conclusion, the findings also suggest a possible difference in RIS between ion and neutron irradiations.

36 MATERIALS SCIENCE↗

Analysis of position-dependent cavity parameters in irradiated metals to obtain insight on fundamental defect migration phenomena

Motion of point defects is a fundamental process that governs microstructure and properties of materials. Here, we examine the near-surface and grain boundary cavity swelling depth profiles in neutron- and ion-irradiated simple metals (Cu, Ni, and Fe-Cr) and investigate diffusional broadening of implanted Ni ions in Fe-Cr alloys. Vacancy migration energies and radiation-enhanced diffusion were experimentally estimated. Cavity denuded zone widths near planar sinks are shown to be dependent on temperature, damage rate, balance of point defects and sinks, and vacancy migration energies. An enhanced cavity swelling zone adjacent to the void-denuded zone was observed in specimens with low to moderate sink strength and interpreted as evidence of 1D gliding interstitial clusters. Radiation-enhanced diffusional broadening of implanted Ni ions (at 400–550 °C) in Fe and Fe-Cr was up to 250 nm toward the surface, which leads to a much broader near-peak-damage region where cavity swelling is suppressed. Diffusional broadening of implanted ions is calculated to be similarly pronounced for self-ion irradiations, particularly near the peak and higher swelling temperature regimes. Adequately high ion energies (~8–15 MeV) are recommended for ion-irradiation studies to provide a sufficiently broad midrange safe analysis region with minimized surface and injected ion effects.

36 MATERIALS SCIENCE↗

Amorphization resistance of nanocrystalline 3C-SiC implanted with H2+ ions

Compared to single-crystal SiC, nanocrystalline SiC with high densities of stacking faults has been reported to be much more resistant to amorphization under self-ion and electron irradiations. This study examines H2+ ion irradiation-induced amorphization in nanocrystalline 3C-SiC with dense stacking faults using transmission electron microscopy. The results show that full amorphization at room temperature occurs at a comparable dose to that for its single-crystal SiC counterpart under the identical irradiation conditions. Both materials are amorphized as a result of local damage accumulation. The formation of the nucleation sites for amorphization is not appreciably affected by the presence of stacking faults and grain boundaries. The behavior may be attributed to the significant chemical effects that may completely immobilize the point defects in SiC at room temperature. The results suggest cautions be excised to use nanocrystalline SiC materials in high H irradiation environment at room temperature. Further studies of the H behavior at elevated temperatures are warranted.

Amorphization, ion irradiation, SiC↗