Search NASA⌕ Search

SEARCH · Search NASA

Results for “self-protective”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Self-Protective Inverters Against Malicious Setpoints Using Analytical Reference Models

This paper presents the concept of self-protective inverters using reference models. In the proposed method, incoming setpoints from the utility operator or third-party aggregators are inspected using analytical reference models before engaging the setpoints to the inverter’s local controller. When a malicious setpoint passes the existing security layers, a smart inverter can examine the integrity of an incoming setpoint in real-time. The efficacy of the developed method has been tested using a laboratory setup, including a three-phase 3kVA SiC-MOSFET inverter and a 12kW NHR 9410 regenerative grid emulator. Furthermore, the results verify that the developed analytical models can provide device-level protection for grid-interactive inverters by inspecting and preventing harmful setpoints from getting engaged to the local controller.

42 ENGINEERING↗

A Technical Evaluation of Self-Protection Dose Rates in U.S. Domestic Nuclear Security Policy

U.S. nuclear security policy uses radiation self-protection as a basis for reducing material attractiveness, but existing dose-rate criteria may not reflect the time scales of theft or sabotage. This report evaluates whether the commonly cited 1 Gy/h at 1 m criterion can plausibly cause adversary task failure during short-duration malicious acts.

Fritchie, Jacob Wesley [Sandia National Laboratori↗

Enhancement of the inherent self-protection of the fast sodium reactor cores with oxide fuel

With the development and research into the generation IV fast sodium reactors, great attention is paid to the enhancement of the core inherent self-protection characteristics. One of the problems dealt here is connected with the reduction of the reactivity margin so that the control rods running should not result in the core overheating and melting. In this paper we consider the possibilities of improving the core of BN-1200 with oxide fuel by a known method of introducing an axial fertile layer into the core. But unlike earlier studies this paper looks at the possibility of using such a layer not only for improving breeding, but also for reducing sodium void reactivity effect (SVRE). This proposed improvement of the BN-1200 core does not solve the problem of strong interference in control and protection system (CPS) rods of BN-1200, but they reduce significantly the reactivity margin for burn-up compensation. This helps compensate all the reactivity balances in the improved core configurations without violating constraints on SVRE value.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Vanadium oxide coatings to self-regulate current sharing in high-temperature superconducting cables and magnets

High-temperature superconductors such as REBa 2 Cu 3 O 7-δ (REBCO, RE = rare earth) enable high-current cables and high-field magnets. By removing the turn-to-turn insulation in a magnet application, recent experiments demonstrated that REBCO magnets can self-protect against catastrophic damage during a superconducting-to-normal transition (quench), i.e., when the stored magnetic energy rapidly converts to heat. The current can bypass the hot spot during a quench, thereby reducing the localized heat dissipation. The removal of the insulation between turns, however, leads to excessive eddy currents during current ramping, thereby forcing a much-prolonged magnet charging time. To address this issue, we investigate vanadium oxide (VO x ) coatings as a temperature-dependent self-switching medium that automatically manages current sharing. VO x coatings (with 1.70 ≤ × ≤ to 2.07) were deposited by reactive cathodic arc deposition, initially on insulating glass to determine the electrical properties, and later on commercial REBCO tapes. The coatings are x-ray amorphous but with a short-range crystalline ordering according to Raman spectrometry. The resistivity of VO x decreased by at least three orders of magnitude when the temperature increased from 80 to 300 K. The coating process is compatible with commercial REBCO tapes as evidenced by the negligible change in the critical current caused by the coating process. Here, the results from current sharing experiments and circuit analysis suggest that the VO x coating can effectively self-regulate current sharing in REBCO magnets, suppress excessive eddy currents, and enable self-protection during quenches.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Validation of Gamma Dose Rate Calculation Methodology using the Morris and Turkey Point Measurements

The ability to accurately predict the dose rates from the spent nuclear fuel assembly is very important for determining whether the used nuclear fuel is self-guarded and self-protected. Studies have shown that the direct numerical calculations of the dose rates gave a much lower value than a typical reference. This report summarizes the benchmark studies performed to evaluate the numerical methodologies used in calculating the gamma dose rates of the spent nuclear fuel assemblies. The Morris and Turkey Point experimental data for dose rates measured through air were used in the analyses. Numerical simulations of the gamma dose rate measurements included the fuel depletion analysis of the fuel assembly as well as its structural materials irradiated inside the reactor core, the radioisotopes decay, and photon transport simulations to calculate the gamma dose rates. The different factors which affect the calculated gamma dose rates were addressed. The calculated results were compared with the measured gamma dose rates. Good agreement was obtained when the detectors were placed at the middle of the fuel assembly region. The deviations of the calculated dose rates became larger when the measurements were performed at the top or bottom fuel assemblies. In these benchmark studies, the spent nuclear fuel assemblies were all PWR assemblies and had fuel burnup around 25 MWd/kg to 40 MWd/kg. Its cooling time before the measurements was around 1.8 years to 7 years. The used nuclear fuel assembly is usually self-protected while discharged from the core. Its radioactivity decreases and after a few tens of years it may fall down below the current threshold of 100 r/h. Future validation work is necessary in order to better evaluate the numerically calculated gamma dose rates with experiments performed for other types of fuel assemblies and for fuel assemblies with higher burnup and/or longer cooling times.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Regulatory Considerations for Domestic Reprocessing Facility Physical Security

U.S. advanced non-light-water reactor vendors may pursue collocated on-site reprocessing activities. Therefore, these facilities are likely to possess formula quantities, or Category I quantities, of special nuclear material (SNM) during normal operations. The U.S. Nuclear Regulatory Commission (U.S. NRC) has yet to formally establish a regulatory framework for commercial reprocessing. While Category I requirements would explicitly not apply in this circumstance under current regulatory requirements, regulatory certainty does not exist. A novel framework should be developed to ensure public health and safety while also risk-informing the physical security requirements. This report reviews the relevant background of related rulemaking activities and proposes risk-informed physical protection requirements to satisfy these objectives. Insights from NRC security-related rulemaking activities provide a substantial technical basis to approach potential establishment of physical security requirements for reprocessing facilities. If a licensee can provide justification that the material satisfies a sufficient self-protecting radiation dose threshold, the material may not be subject to theft or diversion requirements and only potential sabotage requirements would apply. Furthermore, if the material can be justified to be moderately dilute, a set of risk-informed requirements could provide adequate protection of public health and safety. A revised performance objective for prevention of theft of moderately dilute Category I SNM may be detection to allow prompt recovery by a local law enforcement agency. However, a significant caveat to the proposed categorization scheme is the unknown integration of radiological sabotage with requirements for the protection against theft. Future licensees should consult with the NRC regarding treatment of this regulatory topic. Additionally, the self-protecting radiation dose threshold (either the existing or a proposed future threshold) would need to be considered. An integrated approach may apply graded potential requirements for protection against the design basis threat of radiological sabotage currently applicable to commercial nuclear power plants and Category I SNM facilities defined within 10 CFR 73.1(a).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Proteomic analyses reveal the key roles of BrlA and AbaA in biogenesis of gliotoxin in Aspergillus fumigatus

The opportunistic human pathogenic fungus Aspergillus fumigatus primarily reproduces by forming a large number of asexual spores (conidia). Sequential activation of the central regulators BrlA, AbaA and WetA is necessary for the fungus to undergo asexual development. In this study, to address the presumed roles of these key developmental regulators during proliferation of the fungus, we analyzed and compared the proteomes of vegetative cells of wild type (WT) and individual mutant strains. Approximately 1300 protein spots were detectable from 2-D electrophoresis gels. Among these, 13 proteins exhibiting significantly altered accumulation levels were further identified by ESI-MS/MS. Markedly, we found that the GliM and GliT proteins associated with gliotoxin (GT) biosynthesis and self-protection of the fungus from GT were significantly down-regulated in the ΔabaA and ΔbrlA mutants. Moreover, mRNA levels of other GT biosynthetic genes including gliM, gliP, gliT, and gliZ were significantly reduced in both mutant strains, and no and low levels of GT were detectable in the ΔbrlA and ΔabaA mutant strains, respectively. As GliT is required for the protection of the fungus from GT, growth of the ΔbrlA mutant with reduced levels of GliT was severely impaired by exogenous GT. Our studies demonstrate that AbaA and BrlA positively regulate expression of the GT biosynthetic gene cluster in actively growing vegetative cells, and likely bridge morphological and chemical development during the life-cycle of A. fumigatus. - Highlights: • Proteome analyses of WT and mutants reveal 13 differentially expressed proteins. • The GliT and GliM proteins are significantly down-regulated by ΔabaA and ΔbrlA. • Expression of other gliotoxin biosynthetic genes is lowered by ΔabaA and ΔbrlA. • Growth of ΔbrlA strain lacking GliT is completely inhibited by exogenous gliotoxin. • BrlA and AbaA play key roles in biogenesis of gliotoxin in Aspergillus fumigatus.

60 APPLIED LIFE SCIENCES↗

Impedance sources (Z sources) with inherent fault protection for resilient and fire-free electricity grids

Modern societies would not survive without electricity and at the same time electrical faults could cause and have caused many catastrophes—mainly deadly fires—to our societies. There are two types of electricity sources: the voltage source such as generators, charged batteries and capacitors, and the current source such as charged inductors, current-regulated rectifiers, and superconducting magnetic energy storage. An “ideal” voltage source—that is often-sought-or-intentionally engineered—generates a constant voltage irrespective of its load current, and an “ideal” current source injects a constant current irrespective of its load voltage. However, two problems exist: (1) voltage or current sources do not represent many emerging natural/renewable energy sources such as wind turbine generators, photovoltaic cells, and fuel cells, whose output voltage and current are strongly dependent on each other, and (2) a short-circuit fault to an artificially-made and controlled “ideal” voltage source or an open-circuit fault to an “ideal” current source can cause catastrophic failures of the source itself and its surrounding circuits due to large (theoretically infinite) short-circuit current or open-circuit voltage. Here we introduce an impedance source concept to represent, characterize, and model those electricity sources whose output voltage and current are strongly dependent on each other. First, we found that many electric sources with no feedback (or active) control of their output voltage and/or current are a natural impedance source with inherent fault protection at short-circuit or open-circuit faults. Second, any electrical source can be artificially controlled to mimic a natural impedance source. Finally, we show how to apply natural impedance sources and nature-mimicking artificially-controlled sources to the electricity grid—the most complex machine ever made by human beings—to realize electricity grids that are naturally stable, self-protected against electrical faults, and resilient to natural and human-made events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Growth strategies to control tapering in Ge nanowires

We report the effect of PH{sub 3} on the morphology of Au catalyzed Ge nanowires (NWs). Ge NWs were grown on Si (111) substrate at 400 °C in the presence of PH{sub 3}, using vapor-liquid-solid method by chemical vapor deposition. We show that high PH{sub 3}/GeH{sub 4} ratio causes passivation at NW surface. At high PH{sub 3} concentration phosphorous atoms attach itself on NW surface and form a self-protection coating that prevents conformal growth and leads to taper free nanostructures. However, in case of low PH{sub 3} flux the combination of axial and radial growth mechanism occurs resulting in conical structure. We have also investigated axial PH{sub 3}-intrinsic junctions in Ge NWs. The unusual NW shape is attributed to a combination of catalyzed, uncatalyzed and diffusion induced growth.

36 MATERIALS SCIENCE↗

SCALE Shielding Calculations for Advanced Reactor Accident Scenarios

The study results presented in this paper demonstrate the capabilities of the SCALE computer code for non–light water reactor (non-LWR) radiation source term and shielding calculations in support of the U.S. Nuclear Regulatory Commission non-LWR fuel cycle demonstration project. Representative non-LWR types, including the sodium-cooled fast reactor (SFR), the molten salt reactor (MSR), and the heat pipe microreactor (HPMR), were analyzed to evaluate dose rates associated with postulated accident scenarios (SFR and MSR), reactor operation (MSR and HPMR), and fuel self-protecting characteristics (HPMR). New features were implemented in SCALE depletion codes to better simulate MSR operation.

MSR↗

Consistency of relevant cosmological deformations on all scales

Using cosmological perturbation theory we show that the most relevant deformation of gravity is consistent at the linear level. In particular, we prove the absence of unitarity violating negative norm states in the weak coupling regime from sub- to super-Hubble scales. This demonstrates that the recently proposed classical self-protection mechanism of deformed gravity extends to the entire kinematical domain.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraining the baryon-dark matter relative velocity with the large-scale 3-point correlation function of the SDSS BOSS DR12 CMASS galaxies

We search for a galaxy clustering bias due to a modulation of galaxy number with the baryon-dark matter relative velocity resulting from recombination-era physics. We find no detected signal and place the constraint bv <0.01 on the relative velocity bias for the CMASS galaxies. This bias is an important potential systematic of Baryon Acoustic Oscillation (BAO) method measurements of the cosmic distance scale using the 2-point clustering. Our limit on the relative velocity bias indicates a systematic shift of no more than 0.3% rms in the distance scale inferred from the BAO feature in the BOSS 2-point clustering, well below the 1% statistical error of this measurement. In conclusion, this constraint is the most stringent currently available and has important implications for the ability of upcoming large-scale structure surveys such as DESI to self-protect against the relative velocity as a possible systematic.

79 ASTRONOMY AND ASTROPHYSICS↗

Rationally designed bidirectional promoter improves the evolutionary stability of synthetic genetic circuits

One problem with synthetic genes in genetically engineered organisms is that these foreign DNAs will eventually lose their functions over evolutionary time in absence of selective pressures. This general limitation can restrain the long-term study and industrial application of synthetic genetic circuits. Previous studies have shown that because of their crucial regulatory functions, prokaryotic promoters in synthetic genetic circuits are especially vulnerable to mutations. In this study, we rationally designed robust bidirectional promoters (BDPs), which are self-protected through the complementarity of their overlapping forward and backward promoter sequences on DNA duplex. When the transcription of a target non-essential gene (e.g. green fluorescent protein) was coupled to the transcription of an essential gene (e.g. antibiotic resistance gene) through the BDP, the evolutionary half-time of the gene of interest increases 4–10 times, depending on the strain and experimental conditions used. This design of using BDPs to increase the mutational stability of genetic circuits can be potentially applied to synthetic biology applications in general.

59 BASIC BIOLOGICAL SCIENCES↗

Quench Protection Study of Superconducting Magnets for the Materials Plasma Exposure Experiment

To advance the understanding of plasma material interactions, the Material Plasma Exposure eXperiment (MPEX) is a new linear plasma device that will generate and deliver plasma relevant to future fusion reactor divertors. The operation of MPEX is planned to be steady-state in order to facilitate high fluence exposures of plasma facing materials and components. The desire for steady-state operation along with the magnetic field requires the utilization of superconducting coils. The superconducting magnet system for MPEX has been developed. The baseline model has six superconducting magnet and one room-temperature magnet subsystems. In order to protect multiple superconducting magnet systems, quench analysis was carried out to determine the best protection approach for each magnet type. Because the mutual inductance accounts for approximately 35% of the stored energy in the entire system, this must be considered when determining the peak voltages and temperatures during a quench. Two approaches for passive quench protection are considered: (1) self-protecting magnets and (2) use of diodes to sub-divide the coils. For both approaches, active quench detection will be used to ensure all coils are de-energized in the event of a quench. Results of the quench analysis for several quench scenarios are presented.

Burkhardt, Earle↗

Analysis of Defect Irrelevancy in a Non-Insulated REBCO Pancake Coil Using an Electric Network Model

High-temperature superconducting REBCO coated conductor is one of the main candidates for next-generation high field magnets in fusion reactors and particle accelerators owing to their high current-carrying capability. Although these materials can operate at higher temperatures and generate higher magnetic fields than their counterparts with lower critical temperatures, protecting the REBCO magnet against quench is challenging. A variety of candidate technologies that may be able to enable self-protection, including no-insulation technology and insulative coatings with temperature-dependent resistance, are in development. Here, in order to understand current sharing and thermal processes during a quench, we model a REBCO pancake coil as an electrical circuit, considering power generation and heat transfer along conductor turns, and study the current distribution around a local defect with lower critical current. The magnetic field and coil terminal voltage predicted by the simulation was compared to published experimental results. Our results provide useful insights into how current sharing occurs around defects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Metal-Insulation REBCO Pancake Coil With Solder Surface Shunt: Testing and Modeling

Rare-earth barium copper oxide (REBCO) high-temperature superconducting (HTS) magnets can generate very high magnetic fields with superior engineering current density and robust mechanical integrity. The no-insulation (NI) winding technique, including its metal-insulation (MI) variant, enables “self-protection” against localized overheating through inter-turn current sharing, improving defect tolerance and allowing temporary current overloads. In REBCO pancake coils, the current-sharing path is predominantly confined to the edges of the REBCO tapes due to insulating buffer layers. Applying a surface shunt using solder can effectively enhance current sharing in NI/MI coils via the REBCO tape edges. Here, in this paper, we present both experimental and numerical research on the current distribution in surface-shunt metal-insulation (SSMI) REBCO pancake coils. We tested a stainless steel co-wound MI REBCO double-pancake coil, before and after applying a soldered surface shunt, in a saturated liquid nitrogen bath. The SSMI coil was modeled using the H-formulation and rotated anisotropic resistivity to study its dynamic behavior, including inter-turn current sharing and intra-turn screening currents. Benchmarked by experimental data, the numerical model is able to study the defect tolerance of the SSMI coil during energization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Provably-Stable Overload Ride-Through Control for Grid-Forming Inverters Using System-Wide Lyapunov Function Analysis

A key challenge associated with a grid-forming (GFM) inverter based resource (IBR) is its behavior during severe grid disturbances: since a GFM inverter regulates voltage in the fast timescale instead of current or power, it may experience a transient overload of current, power and/or energy during a severe grid disturbance. While many promising control strategies for overload ride-through have been proposed over the past two decades, transient stability of the system during and after the transition to an overload ride-through control mode remains difficult to guarantee. In this work, a novel overload ride-through control strategy is proposed for a system of grid-forming inverters that takes both self-protection and system-wide transient stability into account. A proposed system-level supervisory control uses slow communication to pre-emptively assign a set of local ride through control parameters to individual GFM IBR, including a current-limiting virtual reactance, that guarantees that synchronism is still preserved for any set of anticipated grid disturbances. At the core of the supervisory control lies a Lyapunov-function-based routine capable of establishing a strong, albeit conservative, transient stability guarantee for the system. Here, the proposed overload ride-through control strategy is validated via numerical integration of a reduced-order model, as well as through detailed electromagnetic transient (EMT) simulation.

30 DIRECT ENERGY CONVERSION↗

Comparison of the PLTEMP code flow instability predictions with measurements made with electrically heated channels for the advanced test reactor.

When the University of Missouri Research Reactor (MURR) was designed in the 1960s the potential for fuel element burnout by a phenomenon referred to at that time as 'autocatalytic vapor binding' was of serious concern. This type of burnout was observed to occur at power levels considerably lower than those that were known to cause critical heat flux. The conversion of the MURR from HEU fuel to LEU fuel will probably require significant design changes, such as changes in coolant channel thicknesses, that could affect the thermal-hydraulic behavior of the reactor core. Therefore, the redesign of the MURR to accommodate an LEU core must address the same issues of fuel element burnout that were of concern in the 1960s. The Advanced Test Reactor (ATR) was designed at about the same time as the MURR and had similar concerns with regard to fuel element burnout. These concerns were addressed in the ATR by two groups of thermal-hydraulic tests that employed electrically heated simulated fuel channels. The Croft (1964), Reference 1, tests were performed at ANL. The Waters (1966), Reference 2, tests were performed at Hanford Laboratories in Richland Washington. Since fuel element surface temperatures rise rapidly as burnout conditions are approached, channel surface temperatures were carefully monitored in these experiments. For self-protection, the experimental facilities were designed to cut off the electric power when rapidly increasing surface temperatures were detected. In both the ATR reactor and in the tests with electrically heated channels, the heated length of the fuel plate was 48 inches, which is about twice that of the MURR. Whittle and Forgan (1967) independently conducted tests with electrically heated rectangular channels that were similar to the tests by Croft and by Walters. In the Whittle and Forgan tests the heated length of the channel varied among the tests and was between 16 and 24 inches. Both Waters and Whittle and Forgan show that the cause of the fuel element burnout is due to a form of flow instability. Whittle and Forgan provide a formula that predicts when this flow instability will occur. This formula is included in the PLTEMP/ANL code.Error! Reference source not found. Olson has shown that the PLTEMP/ANL code accurately predicts the powers at which flow instability occurs in the Whittle and Forgan experiments. He also considered the electrically heated tests performed in the ANS Thermal-Hydraulic Test Loop at ORNL and report by M. Siman-Tov et al. The purpose of this memorandum is to demonstrate that the PLTEMP/ANL code accurately predicts the Croft and the Waters tests. This demonstration should provide sufficient confidence that the PLTEMP/ANL code can adequately predict the onset of flow instability for the converted MURR. The MURR core uses light water as a coolant, has a 24-inch active fuel length, downward flow in the core, and an average core velocity of about 7 m/s. The inlet temperature is about 50 C and the peak outlet is about 20 C higher than the inlet for reactor operation at 10 MW. The core pressures range from about 4 to about 5 bar. The peak heat flux is about 110 W/cm{sup 2}. Section 2 describes the mechanism that causes flow instability. Section 3 describes the Whittle and Forgan formula for flow instability. Section 4 briefly describes both the Croft and the Waters experiments. Section 5 describes the PLTEMP/ANL models. Section 6 compares the PLTEMP/ANL predictions based on the Whittle and Forgan formula with the Croft measurements. Section 7 does the same for the Waters measurements. Section 8 provides the range of parameters for the Whittle and Forgan tests. Section 9 discusses the results and provides conclusions. In conclusion, although there is no single test that by itself closely matches the limiting conditions in the MURR, the preponderance of measured data and the ability of the Whittle and Forgan correlation, as implemented in PLTEMP/ANL, to predict the onset of flow instability for these tests leads one to the conclusion that the same method should be able to predict the onset of flow instability in the MURR reasonably well.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗