Search NASA⌕ Search

SEARCH · Search NASA

Results for “semitransparent device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Curved Focal-Plane Arrays Using Back-Illuminated High-Purity Photodetectors

Curved-focal-plane arrays of back-illuminated silicon-based photodetectors are being developed. The basic idea is to improve the performance of an imaging instrument and simplify the optics needed to obtain a given level of performance by making an image sensor (e.g., a photographic film or an array of photodetectors) conform to a curved focal surface, instead of following the customary practice of designing the optics to project an image onto a flat focal surface. Eyes are natural examples of optical systems that have curved focal surfaces on which image sensors (retinas) are located. One prior approach to implementation of this concept involves the use of curved-input-surface microchannel plates as arrays of photodetectors. In comparison with microchannel plates, these curved-focal-plane arrays would weigh less, operate at much lower voltages, and consume less power. It should also be possible to fabricate the proposed devices at lower cost. It would be possible to fabricate an array of photodetectors and readout circuitry in the form of a very-large-scale integrated (VLSI) circuit on a curved focal surface, but it would be difficult and expensive to do so. In a simple and inexpensive alternate approach, a device (see figure) would have (1) a curved back surface, onto which light would be focused; and (2) a flat front surface, on which VLSI circuitry would be fabricated by techniques that are well established for flat surfaces. The device would be made from ultrapure silicon, in which it is possible to form high-resistivity, thick photodetectors that are fully depleted through their thicknesses. (As used here, "thick means having a thickness between a fraction of a millimeter and a few millimeters.) The back surface would be polished to the curvature of the focal surface of the intended application. To enable the collection of charge carriers excited by photons near the back surface or in the bulk of the device, it would be necessary to form a transparent or semitransparent back-surface electrode, possibly by delta doping. [Delta doping is so named because its density-vs.-depth characteristic is reminiscent of the Dirac function (impulse function): the dopant is concentrated in a very thin layer - nominally, a single atomic layer.]

Nikzad, Shouleh↗

Better Back Contacts for Solar Cells on Flexible Substrates

Improved low-resistance, semitransparent back contacts, and a method of fabricating them, have been developed for solar photovoltaic cells that are made from thin films of I-III-VI2 semiconductor materials on flexible, high-temperatureresistant polyimide substrates or superstrates. The innovative aspect of the present development lies in the extension, to polyimide substrates or superstrates, of a similar prior development of improved low-resistance, semitransparent back contacts for I-III-VI2 solar cells on glass substrates or superstrates. A cell incorporating this innovation can be used either as a stand-alone photovoltaic device or as part of a monolithic stack containing another photovoltaic device that utilizes light of longer wavelengths.

Woods, Lawrence M.↗

Helmet-Mounted Display Of Clouds Of Harmful Gases

Proposed helmet-mounted opto-electronic instrument provides real-time stereoscopic views of clouds of otherwise invisible toxic, explosive, and/or corrosive gas. Display semitransparent: images of clouds superimposed on scene ordinarily visible to wearer. Images give indications on sizes and concentrations of gas clouds and their locations in relation to other objects in scene. Instruments serve as safety devices for astronauts, emergency response crews, fire fighters, people cleaning up chemical spills, or anyone working near invisible hazardous gases. Similar instruments used as sensors in automated emergency response systems that activate safety equipment and emergency procedures. Both helmet-mounted and automated-sensor versions used at industrial sites, chemical plants, or anywhere dangerous and invisible or difficult-to-see gases present. In addition to helmet-mounted and automated-sensor versions, there could be hand-held version. In some industrial applications, desirable to mount instruments and use them similarly to parking-lot surveillance cameras.

Diner, Daniel B.↗

Photovoltaic-Driven Multiple-Quantum-Well Modulator

Proposed high-performance spatial light modulator consists of multiple-quantum-well, strain-layer superlattice similar to one described in accompanying article, "Strain-Layer-Superlattice Light Modulator" (NPO-16915). Device differs from other one, operates in transmission rather than in resonant reflection and therefore includes only one stack of GaAs/InAs layers having total thickness less than penetration depth (1 to 2 micrometer) of optical modulating signal. Alternating, semitransparent semiconductor layers contain space-charge barriers forming quantum wells. Modulating light (with photon energy greater than semiconductor band gap) induces photovoltaic action, which affects transmission of modulated light (having photon energy less than band gap).

Maserjian, Joseph↗

Determining Sizes of Particles in a Flow from DPIV Data

A proposed method of measuring the size of particles entrained in a flow of a liquid or gas would involve utilization of data from digital particle-image velocimetry (DPIV) of the flow. That is to say, with proper design and operation of a DPIV system, the DPIV data could be processed according to the proposed method to obtain particle sizes in addition to particle velocities. As an additional benefit, one could then compute the mass flux of the entrained particles from the particle sizes and velocities. As in DPIV as practiced heretofore, a pulsed laser beam would be formed into a thin sheet to illuminate a plane of interest in a flow field and the illuminated plane would be observed by means of a charge-coupled device (CCD) camera aimed along a line perpendicular to the illuminated plane. Unlike in DPIV as practiced heretofore, care would be taken to polarize the laser beam so that its electric field would lie in the illuminated plane, for the reason explained in the next paragraph. The proposed method applies, more specifically, to transparent or semitransparent spherical particles that have an index of refraction different from that of the fluid in which they are entrained. The method is based on the established Mie theory, which describes the scattering of light by diffraction, refraction, and specular reflection of light by such particles. In the case of a particle illuminated by polarized light and observed in the arrangement described in the preceding paragraph, the Mie theory shows that the image of the particle on the focal plane of the CCD camera includes two glare spots: one attributable to light reflected toward the camera and one attributable to light refracted toward the camera. The distance between the glare spots is a known function of the size of the particle, the indices of refraction of the particle material, and design parameters of the camera optics. Hence, the size of a particle can be determined from the distance between the glare spots. The proposed method would be implemented in an algorithm that would automatically identify, and measure the distance between, the glare spots for each particle for which a suitable image has been captured in a DPIV image frame. The algorithm (see figure) would begin with thresholding of data from the entire image frame to reduce noise, thereby facilitating discrimination of particle images from the background and aiding in the separation of overlapping particles. It is important not to pick a threshold level so high that the light intensity between a given pair of glare spots does not fall below the threshold value, leaving the glare spots disconnected. The image would then be scanned in a sequence of rows and columns of pixels to identify groups of adjacent pixels that contain nonzero brightnesses and that are surrounded by pixels of zero brightness. Each such group would be assumed to constitute the image of one particle. Each such group would be further analyzed to determine whether the image was saturated; saturated particle images must be rejected because the locations of glare spots in saturated images cannot accurately be determined. Within each unsaturated particle image, the centroids (deemed to be the locations) of the glare spots would be determined by means of gradients of brightness distributions and three-point horizontal and three-point vertical Gaussian estimates based on the brightness values of the brightest pixels and the pixels adjacent to them. If the brightness of a given particle image contained only one peak, then it would be assumed that a second glare spot did not exist and that image would be rejected.

Wernet, M. P.↗