Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensor array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Wind turbine sensor array for monitoring avian and bat collisions

Assessment of avian and bat collisions with wind turbines is necessary to ensure that the benefits of renewable wind power generation are not outweighed by mortality of protected species. An onboard, integrated multisensor system capable of providing detection of turbine collision events, including taxonomic information, was developed. The conceptual design of a multisensor system including a vibration sensing node, an optics node, and an bioacoustic node with an event–driven trigger architecture was field–tested on utility–scale wind turbines. A pixel density computational model was built to estimate the spatial coverage and target resolution to the optimized configuration for camera placement. Field test results of the vibration node showed that nearly half of the recorded impact events were successfully identified by visual inspection and running short–time Fourier transform on recorded vibration signals. The remaining undetected impact events were masked under background noise due to low impact energy and high background noise of the operating turbine, which result in subsequent low signal–to–noise ratio. Furthermore, our results demonstrate the feasibility of triggering the system through single impact event sensed by vibration sensors.

17 WIND ENERGY↗

Optimization of Transition Edge Sensor Arrays for Cosmic Microwave Background Observations With the South Pole Telescope

In this paper, we describe the optimization of transition-edge-sensor (TES) detector arrays for the third-generation camera for the South PoleTelescope. The camera, which contains similar to 16 000 detectors, will make high-angular-resolution maps of the temperature and polarization of the cosmic microwave background. Our key results are scatter in the transition temperature of Ti/Au TESs is reduced by fabricating the TESs on a thin Ti(5 nm)/Au(5 nm) buffer layer and the thermal conductivity of the legs that support our detector islands is dominated by the SiOx dielectric in the microstrip transmission lines that run along the legs.

Ding, Junjia↗

Multielectrode Array Sensors to Enable Long-Duration Corrosion Monitoring and Control of Concentrating Solar Power Systems

Molten mixtures of MgCl2-KCl-NaCl are promising heat transfer fluid (HTF) candidates for the next generation of concentrating solar power systems (Gen3 CSP), because of their low cost, high decomposition temperature, and favorable heat transfer characteristics. However, if the chemistry of the salts is not properly controlled, molten chlorides can cause corrosion of high-temperature metal alloys, such as Inconel (R), in CSP systems. Here we demonstrate a corrosion monitoring system that can be used to monitor the health of the structural alloys over long durations. The monitoring system includes a multielectrode array voltammetry sensor that measures the redox potential of molten MgCl2-KCl-NaCl mixture as well as the presence of corrosion products and impurities. The sensors have been successfully operated in static molten salt environments for long durations, and are capable of detecting corrosion products, such as Cr2+ and Fe2+, quantitatively at low concentrations (i.e., approximately 100 ppm) with less than 4% error.

Concentrated solar power↗

Using Bayesian Inference Framework towards Identifying Gas Species and Concentration from High Temperature Resistive Sensor Array Data

High temperature gas sensors have been highly demanded for combustion process optimization and toxic emissions control, which usually suffer from poor selectivity. In order to solve this selectivity issue and identify unknown reducing gas species (CO, CH 4 , and CH 8 ) and concentrations, a high temperature resistive sensor array data set was built in this study based on 5 reported sensors. As each sensor showed specific responses towards different types of reducing gas with certain concentrations, based on which calibration curves were fitted, providing benchmark sensor array response database, then Bayesian inference framework was utilized to process the sensor array data and build a sample selection program to simultaneously identify gas species and concentration, by formulating proper likelihood between input measured sensor array response pattern of an unknown gas and each sampled sensor array response pattern in benchmark database. This algorithm shows good robustness which can accurately identify gas species and predict gas concentration with a small error of less than 10% based on limited amount of experiment data. These features indicate that Bayesian probabilistic approach is a simple and efficient way to process sensor array data, which can significantly reduce the required computational overhead and training data.

Liu, Yixin↗

Spatiotemporal and geometric optimization of sensor arrays for detecting analytes in fluids

Sensor arrays and sensor array systems for detecting analytes in fluids. Sensors configured to generate a response upon introduction of a fluid containing one or more analytes can be located on one or more surfaces relative to one or more fluid channels in an array. Fluid channels can take the form of pores or holes in a substrate material. Fluid channels can be formed between one or more substrate plates. Sensor can be fabricated with substantially optimized sensor volumes to generate a response having a substantially maximized signal to noise ratio upon introduction of a fluid containing one or more target analytes. Methods of fabricating and using such sensor arrays and systems are also disclosed.

47 OTHER INSTRUMENTATION↗

Signal Processing of Multiplexed Optical PWM Signals for Sensor Arrays in Nuclear Environments

Safe and effective generation of terrestrial nuclear power greatly benefits from the actionable data provided by the array of sensors located throughout a plant to provide a holistic online indication of reactor operation. This array includes sensors for monitoring coolant flow and pressure, temperature and heat transfer, radiation levels, structure health monitoring, and other critical parameters for reactor operation. While sensors capable of measuring these parameters have been developed, the electronics used in the pre-amplification and analog-to-digital conversion of the small signals they produce are extremely sensitive and susceptible to damage by high-temperatures and radiation environments nuclear reactors encounter while generating power. The small signals from sensors in nuclear power plants (NPPs) are transmitted over long cable runs which introduce dispersion artifacts into the signals of interest as well as electromagnetic interference (EMI) from lighting fixtures, pumps, mains electricity, and other equipment. To overcome these challenges, a front-end digitization (FREND) platform has been developed to use radiation-tolerant electronics to multiplex, amplify, and optically encode signals from an array of sensors for transmission over an optical fiber to mitigate dispersion and EMI artifacts from long runs of electrical cabling. To recover the optically transmitted data, a signal processing scheme based on 1-dimensional template matching to an indexing channel is described herein and demonstrated to have an effective bit-depth of 9.2 bits (1%). This scheme has been validated in proof-of-concept, non-nuclear testing and preliminary experimental results show good agreement between the measured optical output and and sensor input signals. The FREND system represents a low-loss data link between sensors in nuclear environments and data acquisition hardware which is aimed at improving the signal-to-noise ratio of the data acquired from these sensors to provide better information to operators and researchers.

Sweeney, Dan↗

Development of a 1 x N Fiber Optic Sensor Array for Carbon Sequestration Site Monitoring

A fiber sensor array for sub-surface CO 2 concentrations measurements was developed for monitoring geologic carbon sequestration sites. The fiber sensor array uses a single temperature tunable distributed feedback (DFB) laser operating with a nominal wavelength of 2.004 μm. Light from this DFB laser is direct to one of the 4 probes via an in-line 1 x 4 fiber optic switch. Each of the 4 probes are buried and allow the sub-surface CO 2 to enter the probe through Millipore filters that allow the soil gas to enter the probe but keeps out the soil and water. Light from the DFB laser interacts with the CO 2 before it is directed back through the in-line fiber optic switch. The DFB laser is tuned across two CO 2 absorption features where a transmission measurement is made allowing the CO 2 concentration to be retrieved. The fiber optic switch then directs the light to the next probe where this process is repeated allowing sub-surface CO 2 concentration measurements at each of the probes to be made as a function of time. The fiber sensor array was deployed for fifty-eight days beginning June 19, 2012 at the Zero Emission Research Technology (ZERT) field site where sub-surface CO 2 concentrations were monitored. Background measurements indicate the fiber sensor array can monitor background levels as low as 1,000 parts per million (ppm). A thirty four day sub-surface release of 0.15 tones CO 2 /day began on July 10, 2012. The elevated subsurface CO 2 concentration was easily detected by each of the four probes with values ranging to over 60,000 ppm, a factor of greater than 6 higher than background measurements. The fiber sensor array was also deploy at the Big Sky Carbon Sequestration Partnership (BSCSP) site in north-central Montana between July 9th and August 7th, 2013 where background measurements were made in a remote sequestration site with minimal infrastructure. The project provided opportunities for two graduate students to participate in research directly related to geologic carbon sequestration. Furthermore, commercialization of the technology developed is being pursued with five different companies via the Department of energy SBIR/STTR program

47 OTHER INSTRUMENTATION↗

WO{sub 3} thin film based multiple sensor array for electronic nose application

Multiple sensor array comprising 16 x 2 sensing elements were realized using RF sputtered WO{sub 3} thin films. The sensor films were modified with a thin layer of sensitizers namely Au, Ni, Cu, Al, Pd, Ti, Pt. The resulting sensor array were tested for their response towards different gases namely H{sub 2}S, NH{sub 3}, NO and C{sub 2}H{sub 5}OH. The sensor response values measured from the response curves indicates that the sensor array generates a unique signature pattern (bar chart) for the gases. The sensor response values can be used to get both qualitative and quantitative information about the gas.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A minimum assumption approach to MEG sensor array design

Objective. Our objective is to formulate the problem of the magnetoencephalographic (MEG) sensor array design as a well-posed engineering problem of accurately measuring the neuronal magnetic fields. This is in contrast to the traditional approach that formulates the sensor array design problem in terms of neurobiological interpretability the sensor array measurements. Approach. We use the vector spherical harmonics (VSH) formalism to define a figure-of-merit for an MEG sensor array. We start with an observation that, under certain reasonable assumptions, any array of m perfectly noiseless sensors will attain exactly the same performance, regardless of the sensors' locations and orientations (with the exception of a negligible set of singularly bad sensor configurations). We proceed to the conclusion that under the aforementioned assumptions, the only difference between different array configurations is the effect of (sensor) noise on their performance. We then propose a figure-of-merit that quantifies, with a single number, how much the sensor array in question amplifies the sensor noise. Main results. We derive a formula for intuitively meaningful, yet mathematically rigorous figure-of-merit that summarizes how desirable a particular sensor array design is. We demonstrate that this figure-of-merit is well-behaved enough to be used as a cost function for a general-purpose nonlinear optimization methods such as simulated annealing. We also show that sensor array configurations obtained by such optimizations exhibit properties that are typically expected of 'high-quality' MEG sensor arrays, e.g. high channel information capacity. Significance. Our work paves the way toward designing better MEG sensor arrays by isolating the engineering problem of measuring the neuromagnetic fields out of the bigger problem of studying brain function through neuromagnetic measurements.

60 APPLIED LIFE SCIENCES↗

Fabrication and characterization of nano-gas sensor arrays

A novel structures of Nanomaterials gas sensors array constructed using ZnO, and ZnO doped with Al via sol-gel technique. Two structure arrays are developed; the first one is a double sensor array based on doping with percentages of 1% and 5%. The second is a quadrature sensor array based on several doping ratios concentrations (0%, 1%, 5% and 10%). The morphological structures of prepared ZnO were revealed using scanning electron microscope (SEM). X-ray diffraction (XRD) patterns reveal a highly crystallized wurtzite structure and used for identifying phase structure and chemical state of both ZnO and ZnO doped with Al under different preparation conditions and different doping ratios. Chemical composition of Al-doped ZnO nanopowders was performed using energy dispersive x-ray (EDS) analysis. The electrical characteristics of the sensor are determined by measuring the two terminal sensor’s output resistance for O{sub 2}, H{sub 2} and CO{sub 2} gases as a function of temperature.

36 MATERIALS SCIENCE↗

Comparison of Machine Learning Algorithms for Natural Gas Identification with Mixed Potential Electrochemical Sensor Arrays

Mixed-potential electrochemical sensor arrays consisting of indium tin oxide (ITO), La 0.87 Sr 0.13 CrO 3 , Au, and Pt electrodes can detect the leaks from natural gas infrastructure. Algorithms are needed to correctly identify natural gas sources from background natural and anthropogenic sources such as wetlands or agriculture. We report for the first time a comparison of several machine learning methods for mixture identification in the context of natural gas emissions monitoring by mixed potential sensor arrays. Random Forest, Artificial Neural Network, and Nearest Neighbor methods successfully classified air mixtures containing only CH 4 , two types of natural gas simulants, and CH 4 +NH 3 with >98% identification accuracy. The model complexity of these methods were optimized and the degree of robustness against overfitting was determined. Finally, these methods are benchmarked on both desktop PC and single-board computer hardware to simulate their application in a portable internet-of-things sensor package. The combined results show that the random forest method is the preferred method for mixture identification with its high accuracy (>98%), robustness against overfitting with increasing model complexity, and had less than 10 ms training time and less than 0.1 ms inference time on single-board computer hardware.

03 NATURAL GAS↗

Sensitivity enhancement of grating interferometer based two-dimensional sensor arrays using two-wavelength readout

Diffraction gratings integrated with microelectromechanical systems (MEMS) sensors offer displacement measurements with subnanometer sensitivity. However, the sensitivity of the interferometric readout may drop significantly based on the gap between the grating and the reference surface. A two-wavelength (2-{lambda}) readout method was previously tested using a single MEMS sensor for illustrating increased displacement measurement capability. This work demonstrates sensitivity enhancement on a sensor array with large scale parallelization ({approx}20,000 sensors). The statistical representation, which is developed to model sensitivity enhancement within a grating based sensor array, is supported by experimental results using a thermal sensor array. In the experiments, two lasers at different wavelengths (633 and 650 nm) illuminate the thermal sensor array from the backside, time-sequentially. The diffracted first order light from the array is imaged onto a single CCD camera. The target scene is reconstructed by observing the change in the first diffracted order diffraction intensity for both wavelengths. Merging of the data from two measurements with two lasers was performed by taking the larger of the two CCD measurements with respect to the reference image for each sensor. {approx}30% increase in the average sensitivity was demonstrated for a 160x120 pixel IR sensor array. Proposed architecture is also applicable to a variety of sensing applications, such as parallel biosensing and atomic force microscopy, for improved displacement measurements and enhanced sensitivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sensor array and apparatus for simultaneous observation of tissue electrophysiology, contractility, and growth

A sensor array for simultaneously measuring electrophysiological responses and contractility responses of a tissue includes: a substrate; a multi-electrode array (MEA) disposed in or on the substrate; and a plurality of interdigitized electrodes (IDEs) disposed in or on the substrate. The MEA and the IDEs are interpenetrating within a plane substantially parallel to an upper surface of the substrate. Systems for measuring such responses using the sensor array may also include contacts and/or connectors for interfacing with external control devices, electrodes, and cell culture components such as a chamber and lid. Fabrication techniques for making such systems include: forming a sensor array comprising an interpenetrating arrangement of IDEs and electrodes of a MEA in or on a substrate surface; forming a plurality of contacts for interfacing the system with one or more external devices in or on the substrate surface; and forming leads between the plurality of contacts and the sensor array.

Qian, Fang↗

Laser-Induced Carbon-Based Smart Flexible Sensor Array for Multiflavors Detection

We report a flexible sensor array electronic tongue system that is fabricated on a polymer substrate by the laser direct writing process for multiflavor detection. Electronic tongue is a sensing system that is applied to detect different elements with the same sensor array. By analyzing responses from different measurement units, it enables a cross-sensitivity, namely, the ability of the system to responding to a range of different analytes in solution without specific functionalization of sensors. In this article, a six-unit sensing array system was fabricated by a laser direct writing process. Sensing units were introduced on a flexible polyamide surface. A high surface–volume ratio porous carbon structure was created by a laser-induced carbonization process, which provides stable conductive carbon electrodes with high sensitivity. Different surface treatments, such as gold plating, reduced-graphene oxide coating, and polyaniline coating, were accomplished for different measurement units. By applying principal component analysis, this sensing system shows a promising result for the detection of multiple flavors. The detection limit for each element is about 0.1 mM for NaCl and sugar solutions. Also, it is able to detect 10 –4 times diluted commercial table vinegar solution, which originally contains 5% acetic acid. The detection limit is theoretically lower than the human threshold of 10 mM for NaCl and sugar. Besides, the sensing system shows a high sensitivity and selectivity for mixed elements. Here, by mapping the data points, the sensor system could detect flavor combinations and provide a reliable prediction of analyte concentration ratios.

47 OTHER INSTRUMENTATION↗

Microbial potentiometric sensor array measurements in unsaturated soils

The overarching goal of this study is to demonstrate a novel technology for monitoring changes in electrical potential of unsaturated soils using biofilm-populated electrodes. The novelty of the study stems from the fact that it demonstrates a method for measuring open-circuit potentials (OCP) in environments without the presence of an electrolyte solution. This study also reveals that using a biofilm-populated electrode as a reference in stable environments could successfully be employed to assess and monitor the electrochemical potential generated by plants and microorganisms. The findings imply that long-term (months to years) and real-time measurements of the open-circuit potential in unsaturated soils are possible. Because MPS arrays can directly measure open-circuit potential from the biofilm, the challenges related to locally induced electrochemical changes caused by microorganisms in the soil to achieve optimum physiological levels are eliminated. The simplicity of the technology, which allows for multiple indicator electrodes to be referenced against an “internal” reference electrode, enables spatial-temporal monitoring of the changes in the soil and the generation of 2D- or 3D-signal patterns. Once a signal pattern, generated by an array of sensors, develops (usually after 30 to 90 days), it does not significantly change unless the soil is exposed to external stimuli. The observed OCP phenomena, however, suggests that the change in OCP signal is independent of changes in soil conductivity resulting from the addition of water. In brief, findings suggest that the proposed technology can enable multidimensional profiling and long-term monitoring of changes occurring in unsaturated soils without direct implications of presence of water. The changes in the 2D or 3-D signal patterns, however, can be correlated to other important parameters that characterize soil health.

54 ENVIRONMENTAL SCIENCES↗

PERFORMANCE CHARACTERISTICS OF A VECTOR SENSOR ARRAY IN AN ENERGETIC TIDAL CHANNEL

A compact three-dimensional vector sensor array (termed the NoiseSpotter) was recently developed with the goal of characterizing and localizing sources of sound in energetic environments such as those where marine renewable energy devices are likely to be located. The three vector sensors on the NoiseSpotter are mounted on a bottom platform with each sensor suspended inside an optional flow noise removal shield. The multiple pressure and particle velocity channels on the NoiseSpotter are simultaneously sampled and stored on-board to enable coherent array processing of vector sensor array data. A series of field trials were conducted where the NoiseSpotter was deployed on a bottom platform in an 8 m deep tidal channel in Sequim Bay, Washington. Pure tones were transmitted from a drifting vessel whose distance from the bottom platform varied between 50 m and 500 m. The effect of flow noise on vector sensor array performance is quantified along with the detectability of low intensity sound in an energetic environment. Flow noise removal efficiency for each channel of every vector sensor is demonstrated using multiple metrics derived from the active and reactive intensities computed using the pressure-velocity cross-spectral density matrix. A flow noise removal shield is shown to improve the detectability of low intensity sound such as those that are expected to be emitted by marine renewable energy devices.

Raghukumar, Kaustubha↗

Automated inspection of surface breaking cracks using GMR sensor arrays

We present a prototype for automated magnetic stray field testing of ferromagnetic roller bearings. For this purpose NDE-adapted GMR sensor arrays (giant magneto resistance) are used for the detection of surface breaking cracks. The sensors are miniaturized down to the lower μm-regime to achieve adequate spatial resolution. In doing so, sensor arrays with up to 48 elements are used to inspect the bearing surface within a few seconds only. In contrast to magnetic particle inspection (MPI), where the global magnetization requires a further inspection step and succeeding demagnetization, the presented prototype only locally magnetize the surface area in the vicinity of the GMR Sensors. For the local magnetization, the applied sub-surface magnetic field was simulated and proofed for detecting flaws with a depth of a few 10 μm. By multiplexing the sensor array with an adapted read out electronics we quasi simultaneously detect the normal field component of about 100μm above the surface. The detection of artificial notches with a depth of 40 μm and more could be resolved with a SNR better than 20 dB. The presented testing facility is fast and provides a step towards automated testing of safety relevant steel components.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real-time metocean sensor arrays

A real-time metocean sensor array system may include a one or more floating instruments each including geolocation capabilities and connected to a satellite communication network. In some examples, the floating instruments may further include an omnidirectional hydrophone. Motion and acoustical data gathered by the instruments may be converted by onboard processing logic into wave, current, and/or wind-related observations that may be communicated in real time and analyzed via a cloud-based system.

58 GEOSCIENCES↗