Search NASA⌕ Search

SEARCH · Search NASA

Results for “separation instrument”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Lightfall v0.0.1

Lightfall is a desktop application for synchrotron beamline instrument control, data acquisition, and live analysis at the Advanced Light Source (ALS). Built on Python and Qt, it provides a native graphical interface for operating beamline hardware, configuring and executing experimental scans, and visualizing results in real time. Key features include direct integration with EPICS control systems, a built-in electronic logbook, remote beamline access over secure tunnels, and an interprocess communication (IPC) architecture that coordinates with external analysis applications via ZMQ and EPICS process variables. This IPC approach allows Lightfall to orchestrate specialized analysis tools—including GPU-accelerated streaming correlators—without embedding them, avoiding the dependency conflicts common in monolithic scientific software platforms. Compared to prior approaches such as Xi-CAM's plugin-based architecture, Lightfall's design cleanly separates instrument control from domain-specific analysis, enabling feedback-driven acquisition where live analysis results can adjust scan parameters during an experiment. Its native Qt interface provides responsive performance for real-time data visualization that web-based alternatives struggle to match. Lightfall is designed for use by beamline scientists and staff operating synchrotron instruments at national user facilities.

Pandolfi, Ronald [Lawrence Berkeley National Labor↗

Science of the Van Allen Probes Science Operations Centers

The Van Allen Probes mission operations materialized through a distributed model in which operational responsibility was divided between the Mission Operations Center (MOC) and separate instrument specific SOCs. The sole MOC handled all aspects of telemetering and receiving tasks as well as certain scientifically relevant ancillary tasks. Each instrument science team developed individual instrument specific SOCs proficient in unique capabilities in support of science data acquisition, data processing, instrument performance, and tools for the instrument team scientists. In parallel activities, project scientists took on the task of providing a significant modeling tool base usable by the instrument science teams and the larger scientific community. With a mission as complex as Van Allen Probes, scientific inquiry occurred due to constant and significant collaboration between the SOCs and in concert with the project science team. Planned cross-instrument coordinated observations resulted in critical discoveries during the seven-year mission. Instrument cross-calibration activities elucidated a more seamless set of data products. Specific topics include post-launch changes and enhancements to the SOCs, discussion of coordination activities between the SOCs, SOC specific analysis software, modeling software provided by the Van Allen Probes project, and a section on lessons learned. One of the most significant lessons learned was the importance of the original decision to implement individual team SOCs providing timely and well-documented instrument data for the NASA Van Allen Probes Mission scientists and the larger magnetospheric and radiation belt scientific community.

47 OTHER INSTRUMENTATION↗

Energy-resolved neutron imaging and diffraction including grain orientation mapping using event camera technology

Time-of-flight neutron diffraction and energy-resolved imaging each provide unique perspectives into material properties. Neutron diffraction is useful for assessing microstructural parameters such as phase composition, texture, and dislocation densities, though it typically provides averaged data over the sampled volume. Energy-resolved imaging, on the other hand, offers both spatial and spectral information by detecting Bragg edges and neutron absorption resonances, which enables detailed mapping of microstructure and isotopic composition. When combined, these techniques have the potential to enrich our understanding of material behavior across different scales, enhancing our understanding of complex materials. Traditionally, these modalities are conducted on separate instruments, which is time-consuming and poses challenges for data integration. Here, we report the integration of the LumaCam, an event-mode energy-resolved neutron imaging camera with the HIPPO time-of-flight diffractometer at LANSCE. This integration enables simultaneous diffraction and imaging across the full spectrum, with analysis optimized for diffraction and Bragg-edge imaging in the thermal range (0.45–10 Å) and resonance imaging in the epithermal range (0.5–3000 eV), facilitating comprehensive multi-modal analysis. We demonstrate its capabilities through case studies, including spatial mapping of grain orientations in a steel sample and accurate thickness estimations for irregular samples including a depleted uranium cylinder and a natural silver-containing mineral specimen. The combined setup enhances real-time sample alignment and provides comprehensive data for crystal structure, texture, and isotopic composition analysis. This approach opens new possibilities for advanced applications in nuclear engineering, archaeology, and materials science.

36 MATERIALS SCIENCE↗

BEYONDPLANCK XIII. Intensity foreground sampling, degeneracies, and priors

We present the intensity foreground algorithms and model employed within the BEYONDPLANCK analysis framework. The BEYONDPLANCK analysis is aimed at integrating component separation and instrumental parameter sampling within a global framework, leading to complete end-to-end error propagation in the Planck Low Frequency Instrument (LFI) data analysis. Given the scope of the BEYONDPLANCK analysis, a limited set of data is included in the component separation process, leading to foreground parameter degeneracies. In order to properly constrain the Galactic foreground parameters, we improve upon the previous Commander component separation implementation by adding a suite of algorithmic techniques. These algorithms are designed to improve the stability and computational efficiency for weakly constrained posterior distributions. These are: (1) joint foreground spectral parameter and amplitude sampling, building on ideas from MIRAMARE; (2) component-based monopole determination; (3) joint spectral parameter and monopole sampling; and (4) application of informative spatial priors for component amplitude maps. We find that the only spectral parameter with a significant signal-to-noise ratio using the current BEYONDPLANCK data set is the peak frequency of the anomalous microwave emission component, for which we find $ν$ p = 25.3 ± 0.5 GHz; all others must be constrained through external priors. Future works will be aimed at integrating many more data sets into this analysis, both map and time-ordered based, thereby gradually eliminating the currently observed degeneracies in a controlled manner with respect to both instrumental systematic effects and astrophysical degeneracies. When this happens, the simple LFI-oriented data model employed in the current work will need to be generalized to account for both a richer astrophysical model and additional instrumental effects. This work will be organized within the Open Science-based COSMOGLOBE community effort.

79 ASTRONOMY AND ASTROPHYSICS↗

Fundamental cosmology from ANDES precision spectroscopy

ABSTRACT Fundamental cosmology observations, such as the detection of the redshift drift and tests of the universality of physical laws, are key science and design drivers of the ArmazoNes high Dispersion Echelle Spectrograph (ANDES), an Extremely Large Telescope instrument. While separate forecasts for each of them have been reported, we have developed Fisher matrix based forecast tools combining both of these observables. We demonstrate the synergies between the two ANDES data sets, quantifying the improvements in cosmology and fundamental physics parameter constraints for two separate theoretical paradigms. We publicly release this forecast code, which is one of the tools for the optimization of the ANDES observing strategy.

Marques, C. M. J.↗

Comparing optical four-flux model results with experimental data obtained by integrating sphere measurements

Four-flux theory is a way to model scattering through multiple layers of a system based on diffuse and collimated properties. When compared with measurement results obtained using an integrating sphere or a goniophotometer, an approximation is often made as the physical instrument cannot separate the collimated component from the diffuse light scattered in the forward direction. This paper tries to clarify the meaning of the word diffuse for the different cases and outlines simple corrections to improve the accuracy when comparing four-flux models and measured data based on sample haze and the geometry of the integrating sphere.

Bilokur, Maryna (ORCID:0000000191839650)↗

In-Situ Blade Strain Measurements of a Crossflow Turbine Operating in a Tidal Flow

This data was collected between October 25 and December 12 of 2022 at the University of New Hampshire (UNH) and Atlantic Marine Energy Center (AMEC) turbine deployment platform (TDP). The goal was to collect blade strain data from a crossflow turbine operating in a tidal flow. A table in ('Deployment Schedule.PNG') outlines the various dates when each instrument was operational, and more details can be found via literature listed in 'Related Publications'.txt. This dataset includes zipped folders for each instrument containing data in .csv files for the relevant duration specific to each instrument, along with separate README file for each measurement. Some instrument files are quite large and can pose a challenge for a visual spreadsheet editor to open. A processing software like MATLAB or Python is recommended. All data contained in this submission is unfiltered/unprocessed data unless otherwise noted in the README file. Blade strain was measured using 8 foil-based strain gauges along the span of a single turbine blade. Water currents were measured using Acoustic Doppler Current Profilers (ADCP's) and Acoustic Doppler Velocimeters (ADV's) both upstream and downstream of the turbine for inflow, wake and turbulence measurements. Electrical power output was measured using the Voltsys rectifier. Shaft speed was calculated based on the Voltsys measurements of the permanent magnet three phase generator AC generation frequency, coupled directly to the cross flow turbine under test (i.e., no gear box). Platform motions were captured using a Yost IMU (inertial measurement unit). Turbine thrust loading was measured using a reaction arm about the turbine deployment platform spanning beam, where two bi-directional load cells were connected to the system via a pinned connection. The TDP is a floating structure moored on the Portsmouth facing side of Memorial Bridge pier #2, which spans the Piscataqua River between Portsmouth, NH and Kittery, ME. The Piscataqua River connects the Great Bay Estuary to the Gulf of Maine and the river currents are dominated by tidal flow with water velocities exceeding 2.5 m/s during spring ebb tides at this site which were previously characterized by Chancey 2019. The turbine under test was a modified New Energy Corporation (Calgary, CA) model EVG-025 4-blade H-Darrius type vertical axis cross flow turbine that rotates in the clockwise direction with a rotor diameter of 3.2m and blade length of 1.7m. The hydro-foil profile was a NACA 0021 with a 10 inch chord length and a blade preset pitch angle of +4deg with a positive angle corresponding with the toe in direction. The standard EVG-025 has a rotor diameter of 3.4m and its rated power output is 25kW at 3 m/s. The rotor diameter was reduced to accommodate the size of the existing TDP moon-pool. A single blade of this turbine was further modified to accommodate 8 full-bridge strain gauges (Bharath et al 2023, Bichanich et al 2024). For power performance and other relevant details on the turbine and its characteristics, see O'Byrne 2022.

16 TIDAL AND WAVE POWER↗

UNH TDP - Concurrent Measurements of Inflow, Power Performance, and Loads for a Grid-Synchronized Vertical Axis Cross-Flow Turbine Operating in a Tidal Estuary

This data was collected between October 12 and December 15 of 2021 at the University of New Hampshire (UNH) and Atlantic Marine Energy Center (AMEC) turbine deployment platform (TDP). This data set includes over 29 days of grid connected turbine operation during this 65 day time frame. The priority for this measurement campaign was to collect data while the turbine was electrically connected to the grid by means of a rectifier and inverter. The Fall_2021_UNH_Measurement_Timeline.png highlights when each instrument was functioning and the Fall_2021_UNH_Test_Log.jpg indicates the four main regions for analysis available from this measurement campaign. The TDP is a floating structure moored on the Portsmouth facing side of Memorial Bridge pier #2, which spans the Piscataqua River between Portsmouth, NH and Kittery, ME. The Piscataqua River connects the Great Bay Estuary to the Gulf of Maine and the river currents are dominated by tidal forcing with water velocities exceeding 2.5 m/s during spring ebb tides at this site which were previously characterized by Kaelin Chancey (Assessment Of The Localized Flow And Tidal Energy Conversion System At An Estuarine Bridge - UNH MS Thesis 2019). The turbine under test was a modified New Energy Corporation (Calgary, CA) model EVG-025 4-blade H-Darrius type vertical axis cross flow turbine that rotates in the clockwise direction with a rotor diameter of 3.2m and blade length of 1.7m. The hydro-foil profile was a NACA 0021 with a 10 inch chord length and a blade preset pitch angle of +4deg with a positive angle corresponding with the toe in direction. The standard EVG-025 has a rotor diameter of 3.4m and its rated power output is 25kW at 3 m/s. The rotor diameter was reduced to accommodate the size of the existing TDP moon-pool. This project was pursued to quantify device performance for cross flow turbines operating in a marine environment. Accurate physical models, to characterize cross flow turbine performance, require real operational data sets due to the complexity of blade fluid interactions. This data can help support model development which will help predict turbine performance when analyzing perspective project locations in the future. Instrumentation was deployed to measure; water speed/direction, electrical power output, turbine shaft speed, turbine thrust force, and platform motion. Concurrent measurements of these parameters allow for correlations (cause and affect) to be inferred, allowing for characterization of device performance over a range of operating conditions. Water currents were measured using Acoustic Doppler Current Profilers (ADCP's) and Acoustic Doppler Velocimeters (ADV's) directly upstream and downstream of the turbine for inflow, wake and turbulence measurements. Electrical power output was measured using the Voltsys rectifier and the Shark power meter. Shaft speed was calculated based on the Voltsys measurements of the permanent magnet three phase generator AC generation frequency, coupled directly to the cross flow turbine under test (i.e., no gear box). Platform motions were captured using a Yost IMU (inertial measurement unit). Turbine thrust loading was measured using a reaction arm about the turbine deployment platform spanning beam, where two bi-directional load cells were connected to the system via a pinned connection. This submission includes zipped folders for each instrument containing quality controlled (QC'd) data in daily .csv files for the relevant duration specific to each instrument, along with separate .csv file that contains the units for each variable. Some instrument daily files are quite large and can pose a challenge for a visual spreadsheet editor to open. A processing software like MATLAB or Python is recommended. Note the degree of QC varied between each instrument due to time constraints. Particular time and attention was given to perform quality control tests on the acoustic based instruments that are particularly suscep...

16 TIDAL AND WAVE POWER↗

MZA: A Data Conversion Tool to Facilitate Software Development and Artificial Intelligence Research in Multidimensional Mass Spectrometry

Modern mass spectrometry-based workflows employing hybrid instrumentation and orthogonal separations collect multidimensional data, potentially allowing deeper understanding in omics studies through adoption of artificial intelligence methods. However, the large volume of these rich data challenges existing data storage and access technologies, therefore precluding informatics advancements. Here we present MZA™ (pronounced m-za), the mass-to-charge (m/z) generic data storage and access tool designed to facilitate software development and artificial intelligence research in multidimensional mass spectrometry measurements. Composed by a data conversion tool and a simple file structure based on the HDF5 format, MZA provides easy, cross-platform and efficient programmatic access to raw MS-data, enabling fast development of new tools in data science programming languages such as Python and R. The software executable and example Python and R scripts are freely available at https://github.com/PNNL-m-q/mza.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-Depth Mass Spectrometry-Based Single-Cell and Nanoscale Proteomics

Leukemic stem cells are highly dynamic and heterogeneous. Analysis of leukemic stem cells at the single cell level should provide a wealth of insights that would not be possible using bulk measurements. Mass spectrometry (MS)-based proteomic workflows can quantify hundreds or thousands of proteins from a biological sample and has proven invaluable for biomedical research, but samples comprising large numbers of cells are typically required due to limited sensitivity. Recent developments in sample processing, chromatographic separations and MS instrumentation are now extending in-depth proteome profiling to single mammalian cells. We describe specific techniques that increase the sensitivity of single-cell proteomics by orders of magnitude, enabling the promise of single cell proteomics to become a reality. We anticipate such techniques could significantly advance our understanding of leukemic stem cells.

Liang, Yiran↗

Inferring and evaluating satellite-based constraints on NO x emissions estimates in air quality simulations

Satellite observations of tropospheric NO 2 columns can provide top-down observational constraints on emissions estimates of nitrogen oxides (NO x ). Mass-balance-based methods are often applied for this purpose but do not isolate near-surface emissions from those aloft, such as lightning emissions. Here, we introduce an inverse modeling framework that couples satellite chemical data assimilation to a chemical transport model. In the framework, satellite-constrained emissions totals are inferred using model simulations with and without data assimilation in the iterative finite-difference mass-balance method. The approach improves the finite-difference mass-balance inversion by isolating the near-surface emissions increment. We apply the framework to separately estimate lightning and anthropogenic NO x emissions over the Northern Hemisphere for 2019. Using overlapping observations from the Ozone Monitoring Instrument (OMI) and the Tropospheric Monitoring Instrument (TROPOMI), we compare separate NO x emissions inferences from these satellite instruments, as well as the impacts of emissions changes on modeled NO 2 and O 3 . OMI inferences of anthropogenic emissions consistently lead to larger emissions than TROPOMI inferences, attributed to a low bias in TROPOMI NO 2 retrievals. Updated lightning NO x emissions from either satellite improve the chemical transport model's low tropospheric O 3 bias. The combined lighting and anthropogenic emissions updates improve the model's ability to reproduce measured ozone by adjusting natural, long-range, and local pollution contributions. Thus, the framework informs and supports the design of domestic and international control strategies.

54 ENVIRONMENTAL SCIENCES↗

An automated multi-component gas adsorption system (MC GAS)

The knowledge gap on adsorption of complex mixtures in the literature relative to single component data represents a persistent obstacle to developing accurate process models for adsorption separations. The collection of mixed gas adsorption data is an imminent need for improved understanding of the behavior of adsorbent systems in these diverse adsorption applications. Current approaches to understanding mixture adsorption using predictive theories based on pure component adsorption experiments often fail to capture the behavior of more complex, non-ideal systems. In this work, we present an automated volumetric instrument for the measurement of mixed gas adsorption isotherms. This instrument was validated by comparison to other in-house instruments and data available in the literature, and the binary adsorption measurements were found to be thermodynamically consistent. The automation of this instrument allows for rapid collection of high-quality mixture adsorption data.

47 OTHER INSTRUMENTATION↗

Overview and status of the Long-Baseline Neutrino Facility Far Site cryogenics system

The Sanford Underground Research Facility (SURF) will host the Far Detector of the Deep Underground Neutrino Experiment (DUNE), an international multi-kiloton Long-Baseline neutrino experiment that will be installed about one and a half kilometers underground in Lead, SD. Detectors will be located inside four cryostats filled with almost 70,000 metric tons of ultrapure liquid argon, with a level of impurities lower than 100 parts per trillion of oxygen equivalent contamination. The cryogenics infrastructure supporting this experiment is provided by the Long-Baseline Neutrino Facility (LBNF). This contribution presents modes of operation, layout, and main features of the LBNF Far Site cryogenic system, which is composed of three subsystems: Infrastructure, Proximity, and Internal cryogenics. The Infrastructure cryogenics supports the needs of the cryostat and Proximity cryogenics. It includes the equipment to receive the argon in liquid phase, vaporize it and transfer it underground as a gas, the nitrogen system (composed of the refrigeration system, liquid nitrogen buffer tanks and liquid and gaseous nitrogen distribution), liquid and gaseous argon distribution and process controls. The Proximity cryogenics receives fluids from the Infrastructure cryogenics and delivers them to the Internal cryogenics at the required temperature, pressure, purity and mass flow rate. It includes the argon condensers, liquid and gaseous argon purification and regeneration systems, nitrogen and argon phase separators, piping, valves, and instrumentation. The Internal cryogenics comprises the liquid and gaseous argon distribution inside the cryostats for the commissioning, cool down, fill, and steady state operations of the cryostats and detectors. An international engineering team is designing these systems and will manufacture, install, commission, and qualify them. This contribution describes the main features, performance, functional requirements, and modes of operation of the LBNF Far Site cryogenics system. It also presents the status of the design, along with present and future needs to support the DUNE experiment.

43 PARTICLE ACCELERATORS↗

Particle Soot Absorption Photometer (PSAP) Instrument Handbook

Radiance Research PSAPs as described in this Handbook are deployed in the second ARM Mobile Facility (AMF2) Aerosol Observing System (AOS), the third ARM Mobile Facility (AMF3) AOS, ENA AOS and Mobile Aerosol Observing System (MAOS)-A. An earlier version of the PSAP is currently operated in the ARM Aerial Facility and at SGP. The older SGP instrument is covered in a separate Handbook.

47 OTHER INSTRUMENTATION↗

Optimization of ray-tracing simulations to confirm performance of the GP-SANS instrument at the High-Flux Isotope Reactor

The CG-2 beamline at the High Flux Isotope Reactor (HFIR) exhibits a notable discrepancy between observed count rates and the count rates we would expect based on a Monte-Carlo neutron ray-trace simulation. These simulations consistently predict count rates approximately five times greater than those observed in four separate experimental runs involving different instrument configurations. This discrepancy suggests that certain factors are causing losses in measurements that are not adequately accounted for in the simulation, in particular guide reflectivity or misalignment. To investigate these discrepancies, a high-dimensional simulation parameter approach is applied in order to understand the losses. Region of Interest (ROI) groups along the instrument are assigned to different surfaces of the guide components within the simulation. This allows the parameters of those guide components to be varied as a group to minimize the complexity of the search space. The result is an optimization of simulation parameters using an iterative scheme that aims to minimize the difference between experimentally measured count rates and simulated count rates across all tested collimator combinations. This proposed methodology holds the potential to reveal previously unrecognized sources of intensity loss in the CG-2 beamline at HFIR and improve the accuracy of simulations, leading to enhanced understanding and performance of the beamline for various scientific applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Separation of rare earth element radioisotopes by reverse-phase high-speed counter-current chromatography

Analytical scale purification of rare earth element (REE) radioisotopes is typically accomplished using cation-exchange resins (e.g. AG 50W-X8) and high-performance liquid chromatography (HPLC). Despite the variety of improvements made since the development of this separation process in the 1950s, nearest neighbor separations remain a challenge, as does the issue of irreversible sample adsorption. Herein, we report a study that evaluates the potential of high-speed counter-current chromatography (HSCCC) as an alternative method for purifying REE elements, with specific reference to separations of fission product REE of interest to nuclear forensics. Complementary HSCCC REE separation experiments, one spiked with radiotracer and REE fission product activity, allowed for in depth analysis of resulting fractions from both an elemental (inductively coupled plasma atomic emission spectroscopy, ICP-AES) and radiological (gamma-ray spectrometry, beta counting) purity perspective. The highly reproducible nature of separation profiles generated from HSCCC instruments was leveraged to simplify work-up of samples containing radioisotopes. Subsequent radioanalytical evaluation revealed minimal carryover of Eu into neighboring Sm and Tb fractions (as indicated by presence of 150Eu), and trace contamination of the Tb fraction with Y (as indicated by presence of 91Y). Subtle differences in stationary phase retention across the two columns were reflected in significant variations in decontamination factors of duplicate parallel separations. Furthermore, these differences paired with obtained distribution of radioisotopes provided valuable insights into future improvements. Collectively, this study represents a significant step forward in development of HSCCC technology for task specific REE radioisotope purification.

07 ISOTOPE AND RADIATION SOURCES↗

Top-down proteomics

Proteoforms arising from posttranslational modifications, genetic polymorphisms, and RNA splice variants, play a pivotal role as the key drivers in biology. Thus, a comprehensive understanding of proteoforms is essential for unraveling the intricacies of biological systems and bridging the gap between genotype and phenotype. By analyzing whole proteins without digestion, top-down proteomics (TDP) provides a holistic view of the proteome and presents a next-generation approach for deciphering protein function, uncovering disease mechanisms, and advancing precision medicine. This Primer embarks on a journey into the world of TDP by encapsulating its historical context, underlying principles, recent advances, and an outlook on the future of TDP. The experimental section navigates instrumentation, sample preparation, intact protein separation, tandem mass spectrometry techniques, and data collection. Results decipher raw data, visualize intact protein spectra, unravel data analysis, and explain proteoform identification, characterization, and quantitation, as well as statistical analysis. Various applications of TDP spanning the human proteoform project, biomedical, biopharmaceutical, and clinical applications are described. These are complemented by discussions on measurement reproducibility, limitations, and a forward-looking perspective outlining uncharted waters where the field can advance, and potential exciting future applications of TDP.

Roberts, David S.↗