Search NASA⌕ Search

SEARCH · Search NASA

Results for “separation techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evaluation of hydrograph separation techniques with uncertain end-member composition

Hydrograph separation is one of many approaches used to analyse shifts in source water contributions to stream flow resulting from climate change in remote watersheds. Understanding these shifts is vital, as shifts in source water contributions to a stream can shape water management decisions. Because remote watersheds are often inaccessible and have poorly characterized contributing water sources, or end-members, it is critical to understand the implications of using different hydrograph separation techniques in these data-limited environments. To explore the uncertainty associated with different techniques, results from two hydrograph separation techniques, mass balance and principle component analysis, were compared using 3 years of aqueous geochemical data from the East River watershed located in the Elk Mountains of Central Colorado. Solute concentrations of the end-members were characterized by both a limited set of direct chemical measurements of different sources and detailed seasonal instream chemistry to examine the influences of uncertain end-member compositions in a data-limited environment. Annual volumetric end-member contributions to stream flow had relatively good agreement across separation techniques. Large variations in time were observed in the hydrograph separations, depending on the end-member type, and estimated flow contributions varied between the selected solutes. End-member concentrations characterized by stream chemistry showed several limitations including a reduced number of distinguishable end-members and differences in timing of flow contributions. Here the results highlight the benefits of using multiple hydrograph separation techniques by providing a ‘weight-of-evidence’ approach to environments with limited end-member concentration data.

54 ENVIRONMENTAL SCIENCES↗

Investigation of porous polydimethylsiloxane structures with tunable properties induced by the phase separation technique

This article reports the fabrication and characterization of porous polydimethylsiloxane (PDMS) structures developed by the solvent evaporationinduced phase separation technique. Here, ternary systems containing water/ tetrahydrofuran (THF)/PDMS with various concentrations are produced to form a stable solution. The porous PDMS structures are formed by removing the solvent (THF) and nonsolvent (water) phases during the stepping heat treatment procedure. The analytical ternary phase diagram is constructed based on the thermodynamic equilibrium state in the polymer solution to explain the stable/unstable formulations and the possible composition change path. The results show that the isolated pores with the adjustable pore size ranging from 330 to 1900 μm are obtained by tuning the water to the THF ratio. The mechanical properties of the porous PDMS structures are determined by conducting the tensile tests on the prepared dog bone-shaped specimens. A wide range of elastic modulus ranging between 0.49 and 1.05 MPa was achieved without affecting the density of the porous sample by adjusting the solvent and non-solvent content in the solution. It is shown that the flexibility of the porous structures can be improved by reducing the ratio of water to THF and decreasing the PDMS content. The porosity measurements reveal that the PDMS concentration is the major phase controlling the porosity of the structure, while the effect of water/THF is negligible.

42 ENGINEERING↗

A Comprehensive Review of Selected Major Categories of Lithium Isotope Separation Techniques

The ability to generate materials with an enriched isotopic abundance, that is one that differs from natural abundance, is critical in terms of technology. Isotopes are used in a wide range of applications, including radioactive tracers, nondestructive tests, radiotherapy in human medicine, nuclear fuels, and isotope‐substituted compounds for chemistry and biology research, as well as environmental geochemical signature tracers. A commonly discussed research topic is the isotopic separation of various elements—uranium, hydrogen, lithium, and iodine, among many others. Among these isotopes, lithium isotopes are especially important in various applications including strategic areas. These isotopes are light and hence their separation techniques are not very obvious. Herein, all the main categories of Li isotope separation are reviewed in depth with a focus on electrochemical technologies for stable lithium isotope separation.

Murali, Arun↗

Electrokinetic separation techniques for studying nano- and microplastics

This perspective focuses on electrokinetic methods for separating the smallest microplastics (<10 μm) on the basis of charge. Advantages, limitations, and future research opportunities regarding electrokinetic separation methods are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Generation and Study of Am(IV) by Temperature-Controlled Electron Pulse Radiolysis

Used nuclear fuel (UNF) separation techniques that strive to separate radiotoxic americium (Am) from trivalent lanthanide fission products through oxidation state control have increased research efforts surrounding Am(V) and Am(VI). However, equivalent knowledge of the tetravalent state, Am(IV), has remained elusive, particularly in conditions more representative of UNF reprocessing, i.e., in concentrated nitric acid (HNO3). With this in mind, we have used electron pulse radiolysis to study the radiation-induced redox reaction of Am(III) with the oxidizing nitrate radical (NO3?) in 6 M HNO3: Am(III) + NO3? ? Am(IV) + NO3? . These experiments enabled us to observe the growth and decay of Am(IV) in a concentrated acidic solution for the first time. The transient Am(IV) species was found to have a lifetime of ~16 µs?sufficiently long-lived to play a critical mechanistic role in UNF reprocessing systems. Additionally, we performed the first-ever temperature-dependent kinetics study of an actinide element, elucidating unprecedented Arrhenius and Eyring activation parameters for the reaction of Am(III) with NO3?. This new knowledge provides much-needed molecular-level insights into the radiation-induced behavior of Am.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Measurement of the Pion Exclusive Electro-Production Cross-Section in the E12-19-006 Experiment in Hall-C at Jefferson Lab

One of the most effective methods for exploring the transition from hadronic degrees of freedom to quark-gluon degrees of freedom in Quantum Chromodynamics (QCD) is through the investigation of \exclusive" pion and kaon electro-production reactions at various Q2 and ?t values. The E12-19-006 experiment is conducted within the confi?nes of experimental Hall C at the Thomas Jefferson National Accelerator Facility, USA, for such studies. The primary aim of the experiment is to ?first enhance our comprehension of the pion electro-production cross-section and its form factor at Q2 = 0.38 and 0.42 GeV2. This is the fi?rst run period of the E12-19-006 experiment which ran in summer 2019. A more profound understanding of the pion electro-production reaction, 1H(e,e'?+)n, at low Q2 is deemed essential to employ this electro-production reaction (an indirect technique) for the high Q2 studies, thereby delving deeper into the realm of QCD. Consequently, this dissertation presents a thorough analysis of the experimental data acquired in the ?first run period of the E12-19-006 experiment. In pursuit of precision, a series of systematic studies (target boiling correction study, the elastic reaction cross-section measurements, study for determining vari- ous kinematics o?sets, etc.) are conducted to discern the accuracy of the analyzed data, a prerequisite for the use of Rosenbluth separation technique to separate the pion electro-production cross-section terms in t bins. The separated pion electro-production cross-section through the Rosenbluth separation technique is then used to extract the pion electromagnetic form factor. In this dissertation, the pion electro-production cross-section is carefully dissected into its four constituent components: longitudinal (?L), transverse (?T ), longitudinal-transverse (?LT ), and transverse-transverse (?TT ), using the full version of Rosenbluth separation technique for the Q2 = 0.38 GeV2. The technique is simultaneously fi?tted to the unseparated pion electro-production cross-sections at the three values of polarization of the virtual photon (?), i.e., ? = 0.286, 0.629 and 0.781. An iterative process is applied to re?ne the parameters of the model cross-sections until the yield ratio of experimental and Monte Carlo simulation converges. In this study, 21 iterations are conducted to re?ne the model cross-section parameters. The fi?nal pion electro-production cross-section terms are then determined for 7 t bins using the optimized parameters of the model cross-sections.

Kumar, Vijay↗

Thermomechanical Separation of Biogenic and Non-biogenic Carbon from Non-Recyclable MSW

The effective separation of biogenic and non-biogenic carbon from non-recyclable municipal solid waste (n-MSW) presents a significant challenge in the United States. Currently, there are no efficient methods available to address this issue, hindering the potential for maximizing waste utilization and reducing landfilling rates. This project aims to develop and implement a combine thermomechanical separation techniques to separate biogenic and non-biogenic carbon within n-MSW, ultimately facilitating greater resource recovery and enhancing the efficiency and environmental impact of waste management practices.

09 - BIOMASS FUELS↗

Hydrogen sensing and separation

Techniques for hydrogen sensing and mitigation are provided. As one example, a device includes a chamber and a membrane that is permeable to a first gas and is impermeable to a second gas. The membrane separates the chamber from a gas mixture that contains the first gas, such that the first gas in the gas mixture can only enter the chamber via the membrane. The device also includes a pressure sensor configured to measure a pressure within the chamber.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermodynamic modeling of adsorption at the liquid-solid interface

Adsorptive separation techniques are significantly energy efficient in comparison to conventional thermal separation techniques such as distillation. Despite extensive research and development activities undertaken for mixed-gas adsorption, the use of adsorption techniques for the separation of multicomponent liquid mixtures is still limited. A major barrier is the lack of accurate adsorption thermodynamic models, which form the scientific foundation of process simulation of such systems, making the translation to industrial scale challenging. In this work, we have rigorously computed the surface excess of adsorption for six binary liquid mixtures on silica gel at 303 K using the frameworks of the generalized Langmuir isotherm (gL) and the adsorbed solution theory (AST). The six binary liquid mixtures were formed by the pair-wise combinations of four components: benzene, 1,2-dichloroethane, cyclohexane, and n-heptane. We have based our calculations by considering simultaneous equilibria of three phases: saturated vapor phase, bulk liquid phase, and adsorbed phase. Further, the composition of the corresponding saturated vapor phase was estimated by the Nonrandom Two-Liquid activity coefficient model and experimental vapor-liquid equilibria data. The activity coefficients of the adsorbed phase, the central issue of multicomponent adsorption thermodynamics, were calculated using the adsorption Nonrandom Two-Liquid activity coefficient model. Devoid of simplifying assumptions, gL and AST provide rigorous thermodynamic frameworks for adsorption equilibria of multicomponent liquid mixtures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Blood Plasma Self-Separation Technologies during the Self-Driven Flow in Microfluidic Platforms

Blood plasma is the most commonly used biofluid in disease diagnostic and biomedical analysis due to it contains various biomarkers. The majority of the blood plasma separation is still handled with centrifugation, which is off-chip and time-consuming. Therefore, in the Lab-on-a-chip (LOC) field, an effective microfluidic blood plasma separation platform attracts researchers’ attention globally. Blood plasma self-separation technologies are usually divided into two categories: active self-separation and passive self-separation. Passive self-separation technologies, in contrast with active self-separation, only rely on microchannel geometry, microfluidic phenomena and hydrodynamic forces. Passive self-separation devices are driven by the capillary flow, which is generated due to the characteristics of the surface of the channel and its interaction with the fluid. Comparing to the active plasma separation techniques, passive plasma separation methods are more considered in the microfluidic platform, owing to their ease of fabrication, portable, user-friendly features. We propose an extensive review of mechanisms of passive self-separation technologies and enumerate some experimental details and devices to exploit these effects. The performances, limitations and challenges of these technologies and devices are also compared and discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Ion Separations Based on Spontaneously Arising Streaming Potentials in Rotating Isoporous Membranes

Highly selective ion separations are vital for producing pure salts, and membrane-based separations are promising alternatives to conventional ion-separation techniques. Our previous work demonstrated that simple pressure-driven flow through negatively charged isoporous membranes can separate Li+ and K+ with selectivities as high as 70 in dilute solutions. The separation mechanism relies on spontaneously arising streaming potentials that induce electromigration, which opposes advection and separates cations based on differences in their electrophoretic mobilities. Although the separation technique is simple, this work shows that high selectivities are possible only with careful consideration of experimental conditions including transmembrane pressure, solution ionic strength, the K+/Li+ ratio in the feed, and the extent of concentration polarization. Separations conducted with a rotating membrane show Li+/K+ selectivities as high as 150 with a 1000 rpm membrane rotation rate, but the selectivity decreases to 1.3 at 95 rpm. These results demonstrate the benefits and necessity of quantitative control of concentration polarization in highly selective separations. Increases in solution ionic strength or the K+/Li+ feed ratio can also decrease selectivities more than an order of magnitude.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploring rapid chemical separations of Sc-47 produced from photonuclear reactions on natural vanadium targets

Scandium-47 ( 47 Sc) production via bremsstrahlung irradiation of natural vanadium targets offers significant advantages for producing high purity 47 Sc; this work evaluates several rapid dissolution and chemical separation techniques for recovering high purity 47 Sc from irradiated vanadium. Here, techniques developed are combined into a simple, gram-scale, semi-automated target processing system that enables 47 Sc recovery from irradiated vanadium targets with chemical yields as high as 93 ± 3% and 47 Sc/V separation factors of 6 ± 3 ·10 11 within 90 min total processing times. Future research into H 2 O 2 resistant separation techniques and their applicability for direct process coupling to chelation are recommended.

07 ISOTOPE AND RADIATION SOURCES↗

Sequential separation of battery electrode materials and metal foils in aqueous media

To recycle high-value lithium-ion battery components, it is imperative to efficiently separate electrode materials from current collector foils and to separate cathodes from anodes. This study investigates the delamination behaviors of cathodes and anodes from their respective current collectors in aqueous media. Whereas anode films can easily detach from copper foils in water, the delamination of cathode films does not exhibit the same behavior in water; instead, the cation exchange reaction results in lithium leaching and aluminum corrosion in the presence of water. Here, a buffer solution with surfactant additives has been designed to prevent aluminum corrosion and to improve solution wetting behavior, thereby facilitating cathode delamination. The delamination difference enables the sequential recovery of electrode materials and metal foils at different separation stages, simplifying the traditionally intricate processes within a one-pot recovery system. The recovered materials retain their crystal structure and morphology, and there are no signs of aluminum corrosion or residues on the metal foils. The sequential separation technique achieves nearly 100% separation efficiency for electrode materials from metal foils and over 98% separation efficiency for cathode and anode materials.

25 ENERGY STORAGE↗

Origins of Clustering of Metalate–Extractant Complexes in Liquid–Liquid Extraction

Effective and energy-efficient separation of precious and rare metals is very important for a variety of advanced technologies. Liquid-liquid extraction (LLE) is a relatively less energy intensive separation technique, widely used in separation of lanthanides, actinides, and platinum group metals (PGMs). In LLE, the distribution of an ion between an aqueous phase and an organic phase is determined by enthalpic (coordination interactions) and entropic (fluid reorganization) contributions. The molecular scale details of these contributions are not well understood. Preferential extraction of an ion from the aqueous phase is usually correlated with the resulting fluid organization in the organic phase, as the longer-range organization increases with metal loading. However, it is difficult to determine the extent to which organic phase fluid organization causes, or is caused by, metal loading. In this study, we demonstrate that two systems with the same metal loading may impart very different organic phase organizations and investigate the underlying molecular scale mechanism. Small-angle X-ray scattering shows that the structure of a quaternary ammonium extractant solution in toluene is affected differently by the extraction of two metalates (octahedral PtCl 6 2- and square-planar PtCl 6 2- ), although both are completely transferred into the organic phase. The aggregates formed by the metalate-extractant complexes (approximated as reverse micelles) exhibit a more long-range order (clustering) with PtCl 6 2- compared to that with PtCl 6 2- . Vibrational sum frequency generation spectroscopy and complementary atomistic molecular dynamics simulations on model Langmuir monolayers indicate that the two metalates affect the interfacial hydration structures differently. Furthermore, the interfacial hydration is correlated with water extraction into the organic phase. Overall, these results support a strong relationship between the organic phase organizational structure and the different local hydration present within the aggregates of metalate-extractant complexes, which is independent of metalate concentration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigating Radiation-Induced Actinide Species in Solution

Used nuclear fuel (UNF) separation techniques that strive to separate radiotoxic americium (Am) from trivalent lanthanide fission products through oxidation state control have increased research efforts surrounding Am(V) and Am(VI). However, equivalent knowledge of the tetravalent state, Am(IV), has remained elusive, particularly in conditions more representative of UNF reprocessing, i.e., in concentrated nitric acid (HNO3). With this in mind, we have used electron pulse radiolysis to study the radiation-induced redox reaction of Am(III) with the oxidizing nitrate radical (NO3?) in 6 M HNO3: Am(III) + NO3? ? Am(IV) + NO3? . These experiments enabled us to observe the growth and decay of Am(IV) in a concentrated acidic solution for the first time. The transient Am(IV) species was found to have a lifetime of ~16 µs?sufficiently long-lived to play a critical mechanistic role in UNF reprocessing systems. Additionally, we performed the first-ever temperature-dependent kinetics study of an actinide element, elucidating unprecedented Arrhenius and Eyring activation parameters for the reaction of Am(III) with NO3?. This new knowledge provides much-needed molecular-level insights into the radiation-induced behavior of Am.

actinide↗

Machine Straightness Error Measurement Based on Optical Fiber Fabry–Pérot Interferometer Monitoring Technique

Abstract In this research, we propose an Error Separation Technique (EST) based on optical fiber sensors for on-machine straightness error measurement. Two fiber optic Fabry–Pérot interferometers have been developed serving as two displacement sensors. The displacement distance is computed according to the reflected spectrum from interferometers, which can achieve a sub-micrometer resolution. The two-point method has been employed to separate the straightness error of the slides and the profile error of a fine-polished standard block. The spacing distance between two interferometers is determined by the diameter of optical fibers so that the EST's resolution has the potential to reach the sub-millimeter scale. In the experiment, the straightness error has been measured on a commercially available computer numerical control machine tool, and the measurement has been conducted on its x-axis. The spacing distance between two optical fiber sensors is 1.5 mm which equals the EST's resolution along the machine tool's x-axis. The separated profile error of the measured standard block is around 30 µm which has been verified by a high precision Coordinate Measurement Machine (CMM). The magnitude of the separated straightness error is around 40 µm. This technique is flexible and simple to be conducted, which can contribute to the micro-machine tool calibration and other straightness error applications.

Engineering↗