Search NASA⌕ Search

SEARCH · Search NASA

Results for “setup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Wave Setup at the Minamitorishima Tide Gauge

A tide gauge situated on the western shore of Minamitorishima, a small atoll in the western Pacific, has measured sea levels significantly impacted by wave setup. Evidence for this rests with (a) strong correlations between sea level anomalies and high swell and (b) sea-level differences with satellite altimetry that display near-linear dependence on offshore swell heights (regression coefficient 30 cm per meter of swell). Setup is primarily induced by swell from the northwest. We develop models of wave setup which lead to corrected sea levels better reflecting the surrounding ocean, and thus more readily useful to studies of regional sea level and practical applications such as altimetry calibration. The wave setup is also evidently affecting measurements of the tide, with suppressed tide amplitudes in winter when swell is generally largest. In February 2020 the tide gauge was relocated to the southern shore of the island, and the wave setup is now markedly reduced.

Wave setup↗

Broadband Fan Noise Prediction System for Turbofan Engines: Setup_BFaNS User's Manual and Developer's Guide - Volume 1

Pratt & Whitney has developed a Broadband Fan Noise Prediction System (BFaNS) for turbofan engines. This system computes the noise generated by turbulence impinging on the leading edges of the fan and fan exit guide vane, and noise generated by boundary-layer turbulence passing over the fan trailing edge. BFaNS has been validated on three fan rigs that were tested during the NASA Advanced Subsonic Technology Program (AST). The predicted noise spectra agreed well with measured data. The predicted effects of fan speed, vane count, and vane sweep also agreed well with measurements. The noise prediction system consists of two computer programs: Setup_BFaNS and BFaNS. Setup_BFaNS converts user-specified geometry and flow-field information into a BFaNS input file. From this input file, BFaNS computes the inlet and aft broadband sound power spectra generated by the fan and FEGV. The output file from BFaNS contains the inlet, aft and total sound power spectra from each noise source. This report is the first volume of a three-volume set documenting the Broadband Fan Noise Prediction System: Volume 1: Setup_BFaNS User s Manual and Developer s Guide; Volume 2: BFaNS User's Manual and Developer s Guide; and Volume 3: Validation and Test Cases. The present volume begins with an overview of the Broadband Fan Noise Prediction System, followed by step-by-step instructions for installing and running Setup_BFaNS. It concludes with technical documentation of the Setup_BFaNS computer program.

Morin, Bruce L.↗

Samarkand complex setup for investigation of cosmic ray variation in the energy range of 7 10 (9) - 10 (15) eV

The Samarkand complex setup is aimed at the study of cosmic ray variations in a wide energy range from 7 billion eV (which corresponds to the geomagnetic threshold in the region of Samarkand) up to approx 10 to the 15th power to 10 to the 16th power eV. The setup consists of four 6-counter sections of neutron supermonitor with counters SNM-15 and 48 scintillator detectors (1 sq m each) placed under and above the supermonitor. The effective area of the setup for recording neutrons and muons is 24 sq m. The setup can register time variations of the following cosmic ray components: (1) the total neutron counting rate, (2) counting rates for neutrons of different multiplicity, (3) soft-muon fluxes, (4) hard-muon fluxes at various zenith and azimuth angles, (5) electron-photon component, (6) extensive air showers (EAS) induced by primary particles in a wide energy range and accompanied or not accompanied by muons and neutrons.

Dorman, L. I.↗

ASD FieldSpec Calibration Setup and Techniques

This paper describes the Analytical Spectral Devices (ASD) Fieldspec Calibration Setup and Techniques. The topics include: 1) ASD Fieldspec FR Spectroradiometer; 2) Components of Calibration; 3) Equipment list; 4) Spectral Setup; 5) Spectral Calibration; 6) Radiometric and Linearity Setup; 7) Radiometric setup; 8) Datadets Required; 9) Data files; and 10) Field of View Measurement. This paper is in viewgraph form.

Olive, Dan↗

Computer Controlled Magnetotransport Setup for the Characterization of Semiconductor Thin Films

We have considered a computer controlled magnetotransport setup using LabWindows environment. It allows for measurements of resistivity, Hall resistance, carrier concentration and charge mobility in semiconductor thin films using a van der Pauw configuration. The setup features an electromagnet (B = 0.7 Tesla) a 80486-DX 33 computer with a National Instrument AT-MIO 16 AD/DA and a GPIB interface board. A Keithely 224 current source and a Keithley 196 digital voltmeter were also used in the setup. Plans for the addition of capabilities to allow for magnetic field sweeping and the performance of measurements as a function of temperature will be presented.

Ducoudray, G. O.↗

Free Molecular Heat Transfer Programs for Setup and Dynamic Updating the Conductors in Thermal Desktop

The programs, arrays and logic structure were developed to enable the dynamic update of conductors in thermal desktop. The MatLab program FMHTPRE.m processes the Thermal Desktop conductors and sets up the arrays. The user needs to manually copy portions of the output to different input regions in Thermal Desktop. Also, Fortran subroutines are provided that perform the actual updates to the conductors. The subroutines are setup for helium gas, but the equations can be modified for other gases. The maximum number of free molecular conductors allowed is 10,000 for a given radiation task. Additional radiation tasks for FMHT can be generated to account for more conductors. Modifications to the Fortran subroutines may be warranted, when the mode of heat transfer is in the mixed or continuum mode. The FMHT Thermal Desktop model should be activated by using the "Case Set Manager" once the model is setup. Careful setup of the model is needed to avoid excessive solve times.

Malroy, Eric T.↗

Setup for Visual Observation of Carbon-Nanotube Arc Process

A simple optical setup has been devised to enable safe viewing of the arc and measurement of the interelectrode gap in a process in which carbon nanotubes are produced in an arc between a catalyst-filled carbon anode and a graphite cathode. This setup can be used for visually guided manual positioning of the anode to maintain the interelectrode gap at a desired constant value, possibly as a low-technology alternative to the automatic position/voltage control described in Automatic Control of Arc Process for Making Carbon Nanotubes (MSC-23134), NASA Tech Briefs, Vol. 28, No. 3 (March 2004), page 51. The optical setup consists mainly of lenses for projecting an image of the arc onto a wall, plus a calibrated grid that is mounted on the wall so that one can measure the superimposed image of the arc. To facilitate determination of the end point of the process, the anode is notched, by use of a file, at the end of the filled portion that is meant to be consumed in the process. As the anode is consumed and the notch comes into view in the scene projected onto the wall, the process operator switches off the arc current.

Scott, Carl D.↗

TriTruss Strut-to-Joint Bond Test: Analysis and Setup

The TriTruss is a novel structural module developed by researchers at NASA Langley Research Center (LaRC) that can be used in space to assemble large backing structures for a variety of applications. One such application is the metering truss or primary mirror backbone support structure of an in-space assembled telescope (iSAT). For the iSAT application, the TriTruss will be supporting mirror segments, payloads and instruments, all of which require them to have robust structural integrity. Structural proof tests are needed to ensure the integrity of the bonded interface between the joint and structural struts that make up a TriTruss module. For the first phase of the analysis and test setup effort, described in this paper, a series of analyses were performed to determine the optimal setup for applying a single set of loads to a module to verify the integrity of the bonds. This paper describes all the test setup configurations and loads considered and summarizes the final set of loading states that were selected for proof testing each module.

TriTruss↗

Harmonic distortion analyzer speeds setup of magnetic tape recorders

Harmonic distortion analyzer effects rapid and accurate setup and calibration of magnetic tape instrumentation recorders. The analyzer is portable, requires no warmup period and need not be calibrated for normal usage. Average setup time with this analyzer is approximately 30 seconds per track.

Tinari, D. F.↗

Method and apparatus for checking the stability of a setup for making reflection type holograms

A method and apparatus are described for checking the stability of a setup for recording reflection-type (white light) holograms. Two sets of interference fringes are simultaneously obtained, one giving information about coherence and stability of the setup alone and the other demonstrating coherence of the entire system, including the holographic recording plate. Special emphasis is given to the stability of the plate, due to the fact that any minute vibration might severely degrade or completely destroy the recording.

Lackner, H. G.↗

Potential Damage to Flight Hardware from MIL-STD-462 CS02 Setup

The MIL-STD-462 CS02 conducted susceptibility test setup, performed during electromagnetic compatibility (EMC) testing, consists of an audio transformer with the secondary used as an inductor and a large capacitor. Together, these two components form an L-type low-pass filter to minimize the injected test signal input into the power source. Some flight hardware power input configurations are not compatible with this setup and break into oscillation when powered up. This can damage flight hardware and caused a catastrophic failure to an item tested in the Goddard Space Flight Center (GSFC) Large EMC Test Facility.

Harris, Patrick K.↗

Potential Damage to Flight Hardware from MIL-STD-462 CS02 Setup

The MIL-STD-462 CS02 conducted susceptibility test setup includes an audio transformer, with the secondary used as an inductor, and a large capacitor. Together, these two components form an L-type low-pass filter to minimize the injected test signal input into the power source. Some flight hardware power input configurations are not compatible with this setup and break into oscillation when powered up. This, in turn, can damage flight hardware. Such an oscillation resulted in the catastrophic failure of an item tested in the Goddard Space Flight Center (GSFC) Large electromagnetic compatibility (EMC) Test Facility.

Harris, Patrick K.↗

Flight Tests of a 0.13-Scale Model of the Convair XFY-1 Vertically Rising Airplane in a Setup Simulating that Proposed for Captive-Flight Tests in a Hangar, TED No. NACA DE 368

An experimental investigation has been conducted to determine the dynamic stability and control characteristics of a 0.13-scale free-flight model of the Convair XFY-1 airplane in test setups representing the setup proposed for use in the first flight tests of the full-scale airplane in the Moffett Field airship hangar. The investigation was conducted in two parts: first, tests with the model flying freely in an enclosure simulating the hangar, and second, tests with the model partially restrained by an overhead line attached to the propeller spinner and ground lines attached to the wing and tail tips. The results of the tests indicated that the airplane can be flown without difficulty in the Moffett Field airship hangar if it does not approach too close to the hangar walls. If it does approach too close to the walls, the recirculation of the propeller slipstream might cause sudden trim changes which would make smooth flight difficult for the pilot to accomplish. It appeared that the tethering system proposed by Convair could provide generally satisfactory restraint of large-amplitude motions caused by control failure or pilot error without interfering with normal flying or causing any serious instability or violent jerking motions as the tethering lines restrained the model.

Lovell, Powell M., Jr.↗

The Evaluation of a Test Device for Human Occupant Restraint (THOR) Under Vertical Loading Conditions: Part 1 - Experimental Setup and Results

A series of 16 vertical tests were conducted on a Test Device for Human Occupant Restraint (THOR) - NT 50th percentile Anthropomorphic Test Device (ATD) at NASA Langley Research Center (LaRC). The purpose of the tests conducted at NASA LaRC was threefold. The first was to add vertical response data to the growing test database for THOR-NT development and validation. Second, the THOR-NT analytical computational models currently in development must be validated for the vertical loading environment. The computational models have been calibrated for frontal crash environments with concentration on accurately replicating head/neck, thoracic, and lower extremity responses. Finally, familiarity with the THOR ATD is necessary because NASA is interested in evaluating advanced ATDs for use in future flight and research projects. The THOR was subjected to vertical loading conditions ranging between 5 and 16 g in magnitude and 40 to 120 milliseconds (msec) in duration. It was also tested under conditions identical to previous tests conducted on the Hybrid II and III ATDs to allow comparisons to be made. Variations in the test setup were also introduced, such as the addition of a footrest in an attempt to offload some of the impact load into the legs. A full data set of the THOR-NT ATD will be presented and discussed. Results from the tests show that the THOR was largely insensitive to differences in the loading conditions, perhaps due in part to their small magnitudes. THOR responses, when compared to the Hybrid II and III in the lumbar region, demonstrated that the THOR more closely resembled the straight spine Hybrid setup. In the neck region, the THOR behaved more like the Hybrid III. However in both cases, the responses were not identical, indicating that the THOR would show differences in response than the Hybrid II and III ATDs when subjected to identical impact conditions. The addition of a footrest did not significantly affect the THOR response due to the nature of how the loading conditions were applied.

Littell, Justin D.↗

Experimental Setup and Parameters for Testing Uncoated and EBC-Coated CMCs under Thermal Gradients Induced by Laser Heating and Backside Air Cooling

An experimental setup to induce through thickness thermal gradients in ceramic matrix composite (CMC) specimens without and with an applied environmental barrier coating (EBC) is described in detail. Components of the experimental set up include a laser for the heat source on the front of the specimen, a cooling air nozzle on the back of the specimen with pyrometers to measure temperatures on both sides, and a full-field thermal image camera to ensure uniformity of the temperature distribution in the gage section of the specimen. Test specimen is loaded in a servohydraulic system, which can superimpose either static or dynamic loads on the specimen to investigate creep and fatigue behaviors of CMCs under through thickness thermal gradient conditions. Mechanical strains on the front and backsides of the test specimen were measured during the thermal gradient tests with superimposed mechanical loading using two contact extensometers. Selected through thickness thermal gradient test results generated with the experimental setup under different nominal front side temperatures and multiple constant laser power levels on uncoated and EBC coated CMCs and procedures used to generate those results are described in this report. Two examples of tests conducted using the test system on uncoated CMCs under creep and sustained-peak, low-cycle fatigue with through thickness thermal gradient conditions are provided.

ceramic matrix composite, environmental barrier co↗

Camera Setup for Unsteady Pressure Sensitive Paint at NASA Ames Research Center

The unsteady Pressure-Sensitive Paint Development Team at NASA Ames Research Center is conducting a Launch Vehicle Demo Test in the Unitary Plan Wind Tunnel’s 11-ft Transonic Wind Tunnel in the first half of 2024 to showcase improvements made to unsteady Pressure-Sensitive Paint technology. The unsteady Pressure-Sensitive Paint setup has upgraded from a four-camera system to an eight-camera system, prompting analysis to maximize the system performance and overall data quality. Additional analysis was performed to maximize the system resolving power when subject to test constraints such as model size and model tunnel positions. These analyses have uncovered new opportunities to improve the unsteady Pressure-Sensitive Paint technology and will allow the system to collect higher quality data with simple changes to the setup procedure.

Camera Calibration↗