Search NASA⌕ Search

SEARCH · Search NASA

Results for “shade”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Designing Modules to Prevent Reverse Bias Degradation in Perovskite Solar Cells when Partial Shading Occurs

When a solar cell in a panel is shaded, the illuminated cells can place a large reverse bias on the shaded cell to attempt to force current through it. Although the panel can continue to produce power, the reverse bias can cause significant problems for the shaded cell. In the case of perovskite solar modules, Joule heating and irreversible electrochemical reactions will degrade the cell. Some photovoltaic technologies use bypass diodes to solve this problem. To prevent both a perovskite cell and an all-perovskite tandem cell from falling into reverse bias breakdown while shaded, no more than two cells per bypass diode are allowed, which is likely to be prohibitively expensive for many applications. Herein, how many solar cells can be protected by one bypass diode in single-junction and multijunction perovskite modules is explored. It is easier to incorporate bypass diodes into modules with singulated cells than with monolithic panels. It is shown that perovskite–silicon tandems can be protected with fewer bypass diodes than with single-junction perovskite modules. Furthermore, it is suggested that if bypass diodes cannot be feasibly incorporated, then the panels should be deployed in utility-scale power plants.

14 SOLAR ENERGY↗

The U.S. Agrivoltaic Shading Tool: A National-Scale Interface for Modeling Light and Shade Patterns in Ten Common Agrivoltaic Configurations

Agrivoltaic systems are dual-use configurations that co-locate agriculture and photovoltaic (PV) infrastructure and require careful design to balance crop performance and energy generation. A critical element of agrivoltaic design is the spatial and temporal distribution of irradiance and shade within and around PV arrays. To support research, planning, and stakeholder decision-making, we introduce the U.S. Agrivoltaic Shading Tool, a novel web-based application that delivers high-resolution irradiance and photosynthetically active radiation (PAR) modeling for ten standardized PV configurations across the conterminous United States. The tool leverages the National Laboratory of the Rockies (NLR) System Advisor Model (SAM) to perform detailed irradiance simulations, using meteorological data from the National Solar Radiation Database (NSRDB). Outputs include seasonal, monthly, weekly, and diurnal patterns of available sunlight, amount of shade, irradiance, and PAR at ground level within agrivoltaic system footprints. For a user's selected location, these results are visualized through interactive visualizations, heatmaps, and time-series plots, designed to be accessible to both technical and non-technical users. In addition to facilitating rapid spatial exploration of agrivoltaic light environments, the tool will offer seamless integration with the InSPIRE Agrivoltaics Design and Analysis Model (ADAM). This optional workflow will allow users to port selected site and configuration parameters into a more advanced modeling environment for further customization of structural layouts, crop-system compatibility, power generation, and technoeconomic performance. Finally, to promote open science, the entire dataset will be hosted and available for open access through the OpenEI platform. By standardizing and disseminating high-quality irradiance data and design tools, the U.S. Agrivoltaic Shading Tool supports a wide range of users, including researchers, landowners, energy developers, and policymakers, in evaluating the agronomic and energetic feasibility of agrivoltaic systems across the United States.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Comparing the OpenSolar Remote Shading Analysis Tool to On-Site Shading Measurements

OpenSolar is a free of charge application built for solar installers that creates a fully articulated 3D model of the site and performs remote shading analysis, in order to produce highly accurate designs and interactive, customizable proposals. Under the National Renewable Energy Laboratory (NREL) Commercialization Assistance Program (NCAP), NREL independently verified the accuracy of OpenSolar's remote analysis of solar access percentage values (SAVs) on an annual basis for locations in Los Angeles, CA, and Denver, CO. In aggregate, the results of the analysis show that Open Solar-calculated annual SAV measurements were statistically equivalent within ±2.63 SAVs for Los Angeles locations and ±2.69 SAVs for Denver locations compared to those of on-site measurements made with SunEye devices.

MATHEMATICS AND COMPUTING,SOLAR ENERGY↗

Shading contributes to Sphagnum decline in response to warming

Experimental warming of an ombrotrophic bog in northern Minnesota has caused a rapid decline in the productivity and areal cover of Sphagnum mosses, affecting whole-ecosystem carbon balance and biogeochemistry. Direct effects of elevated temperature and the attendant drying are most likely the primary cause of the effects on Sphagnum, but there may also be responses to the increased shading from shrubs, which increased with increasing temperature. To evaluate the independent effects of reduction in light availability and deposition of shrub litter on Sphagnum productivity, small plots with shrubs removed were laid out adjacent to the warming experiment on hummocks and hollows in three blocks and with five levels of shading. Four plots were covered with neutral density shade cloth to simulate shading from shrubs of 30%–90% reduction in light; one plot was left open. Growth of Sphagnum angustifolium/fallax and S. divinum declined linearly with increasing shade in hollows, but there was no response to shade on hummocks, where higher irradiance in the open plots may have been inhibitory. Shading caused etiolation of Sphagnum—they were thin and spindly under the deepest shade. A dense mat of shrub litter, corresponding to the amount of shrub litter produced in response to warming, did not inhibit Sphagnum growth or cause increases in potentially toxic base cations. CO 2 exchange and chlorophyll-a fluorescence of S. angustifolium/fallax from the 30% and 90% shade cloth plots were measured in the laboratory. Light response curves indicate that maximal light saturated photosynthesis was 42% greater for S. angustifolium/fallax grown under 30% shade cloth relative to plants grown under 90% shade cloth. The response of Sphagnum growth in response to increasing shade is consistent with the hypothesis that increased shade resulting from shrub expansion in response to experimental warming contributed to reduced Sphagnum growth.

59 BASIC BIOLOGICAL SCIENCES↗

Cellular Shade Energy Savings in a Commercial Setting

Windows cause approximately 1.7 quad of heating and cooling energy consumption in the United States. This energy consumption can be reduced by using high-efficiency window attachments. Common Venetian blinds and planar shades, such as roller shades, might block solar radiation, but they do not provide a significant improvement to window system thermal transmittance. Cellular shades have better thermal performance compared to other shading devices because of the honeycomb structure that traps air in pockets to create thermal insulation. However, evaluating the energy savings potential of cellular shades using experimental testing in commercial settings is limited. Moreover, the effect of cellular shades on daylighting and glare is yet to be evaluated using field testing. In this study, experimental testing of cellular shades was performed in a real building with emulated occupancy for both a cooling and a heating season. Compared with a room without shades, the use of cellular shades in experimental testing showed incremental energy savings of 4.6% to 9.4% for cooling and higher than 20% for heating. The experimental data were used to calibrate the baseline energy model and validate the cellular shades model. Annual simulation of cellular shades was performed for a medium office prototype building using the validated cellular shades model. The annual simulation was performed in Phoenix, Nashville, and Rochester. The annual savings for HVAC energy was 25% for Phoenix, 27% for Nashville, and 19% for Rochester.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal insulation versus capacitance: A simulation experiment comparing effects of shade and hyporheic exchange on daily and seasonal stream temperature cycles

In streams where water temperatures stress native biota, management of riparian shade or hyporheic exchange are both considered viable management strategies for reducing the peaks of daily and seasonal stream channel temperature cycles. Although shade and hyporheic exchange may have similar effects on stream temperatures, their mechanisms differ. Improved understanding of the heat-exchange mechanisms influenced by shade and hyporheic exchange will aid in the appropriate application of either stream temperature management strategy. To illustrate a conceptual model highlighting shade as ‘thermal insulation’ and hyporheic exchange imparting ‘thermal capacitance’ to a stream reach, we conducted an in-silico simulation modelling experiment increasing shade or hyporheic exchange parameters on an idealized, hypothetical stream. We assessed the potential effects of increasing shade or hyporheic exchange on a stream reach using an established process-based heat-energy budget model of stream-atmosphere heat exchange and incorporated an advection-driven hyporheic heat exchange routine. The model tracked heat transport through the hyporheic zone and exchange with the stream channel, while including the effects of hyporheic water age distribution on upwelling hyporheic temperatures. Results showed that shade and hyporheic exchange similarly damped diurnal temperature cycles and differentially altered seasonal cycles of our theoretical stream. In winter, hyporheic exchange warmed simulated channel temperatures whereas shade had little effect. In summer, both shade and hyporheic exchange cooled channel temperatures, though the effects of shade were more pronounced. Our simple-to-grasp analogies of ‘thermal insulation’ for shade effects and ‘thermal capacitance’ for hyporheic exchange effects on stream temperature encourage more accurate conceptualization of complex, dynamic heat exchange processes among the atmosphere, stream channel, and alluvial aquifer.

54 ENVIRONMENTAL SCIENCES↗

National energy savings potential of cellular shades: A measurement and simulation study

Windows are major contributors to energy demand in residential homes because of their inferior thermal resistance compared with the opaque envelope, and sometimes from unwanted solar heat gain. Window attachments can help mitigate the energy demand by controlling the solar heat gains and enhancing window thermal resistance. Cellular shades have the potential of superior thermal performance compared with generic shades because of its honeycomb structure. Here, in this study, the team analyzed the energy savings potential of cellular shades in residential homes via experimental testing for two heating seasons and energy simulations. Five shading devices—three single-cell and two double cellular/cell-in-cell shades—were used to compare the performance with generic horizontal venetian blinds using two nearly identical side-by-side rooms in a residential home. The experimental testing showed daily heating energy savings in the range of 17%–36% compared with the case without shades. The experimental testing data also exhibited improvements in thermal comfort when using cellular shades. Additionally, energy simulations were performed to evaluate the energy savings potential of the cellular shades using a residential prototype home, which demonstrated energy savings up to 9 kWh/m2/year in cold climates. The total site energy savings for heating and cooling from cellular shades was up to ~9% for the home with a heat pump and up to ~15% for a home with a gas furnace compared with cases without any shading devices. The energy savings at a national scale were up to 14.6 TWh assuming a 20% penetration rate in residential homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Shade signals alter the expression of circadian clock genes in newly-formed bioenergy sorghum internodes

Stem internodes of bioenergy sorghum inbred R.07020 are longer at high plant density (shade) than at low plant density (control). Initially, the youngest newly-formed subapical stem internodes of shade-treated and control plants are comparable in length. However, full-length internodes of shade-treated plants are three times longer than the internodes of the control plants. To identify the early molecular events associated with internode elongation in response to shade, we analyzed the transcriptome of the newly-formed internodes of shade-treated and control plants sampled between 4 and 6 hr after the start of the light period (14 hr light/10 hr dark). Sorghum genes homologous to the Arabidopsis shade marker genes ATHB2 and PIL1 were not differentially expressed. The results indicate that shade signals promote internode elongation indirectly because sorghum internodes are not illuminated and grow while enclosed with leaf sheaths. Sorghum genes homologous to the Arabidopsis morning-phased circadian clock genes LHY, RVE, and LNK were downregulated and evening-phased genes such as TOC1, PRR5, and GI were upregulated in young internodes in response to shade. We hypothesize that a change in the function or patterns of expression of the circadian clock genes is the earliest molecular event associated with internode elongation in response to shade in bioenergy sorghum. Increased expression of CycD1, which promotes cell division, and decreased expression of cell wall-loosening and MBF1-like genes, which promote cell expansion, suggest that shade signals promote internode elongation in bioenergy sorghum in part through increasing cell number by delaying transition from cell division to cell expansion.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of Exterior Shades at PNNL Lab Homes and Occupied Field Sites (Final Report)

In residential applications, heat transfer through windows accounts for a significant portion of a home’s cooling load. Exterior shades are window attachments that can be applied on the exterior-side of windows in a home. Exterior shades can reduce solar heat gain, reduce glare through a window, and improve comfort in the home. To assess the performance of residential exterior shades, the U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Building Technologies Office (BTO) commissioned a series of field studies for exterior fabric shades to be performed by Pacific Northwest National Laboratory (PNNL) during the cooling seasons of 2019 and 2020. This report describes the experimental setup and results of these exterior shade field studies. PNNL, in collaboration with Lawrence Berkeley National Laboratory (LBNL), evaluated exterior shades at the PNNL Lab Homes and three occupied field sites in Richland, Washington. At the Lab Homes, the energy performance of exterior shades was evaluated in a controlled side-by-side environment. At the occupied field sites, exterior shades were characterized by measuring shade usage, documenting installation practices, and surveying customer perspectives.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhancing climate-smart crop performance in arid agrivoltaics systems: effects of photovoltaic shading and soil amendments on tepary bean growth, yield, and associated soil microbiome

As climate change expands the world’s arid and semiarid regions, sustainable systems that integrate food and energy production are becoming increasingly critical. Agrivoltaics—co-locating crops with photovoltaic (PV) panels—offers a dual land-use strategy that mitigates environmental stress by shading crops, conserving soil moisture, and enhancing PV efficiency. While climate-smart crops like the tepary bean ( Phaseolus acutifolius ) are well adapted to heat and drought, little is known about how these crops and their associated soil microbiomes respond to the unique microclimates created by PV shading. This study evaluated tepary bean performance and plant–microbial interactions under PV-shade vs. no shade across three soil amendment treatments at two experimental sites. We assessed plant traits including germination, phenology, biomass, height, as well as yield and bean morphology, alongside shifts in soil microbial composition and functional potential. Plants grown under PV-shade were generally taller, with extended reproductive periods and higher yields: 42% of shaded plants produced beans compared to only 8% under full sun. Shaded plants also produced rounder, higher-quality beans, whereas non-shaded plants yielded flatter, less developed beans. Microbial community composition was more strongly influenced by amendment and site conditions than by shading alone. Key microbial taxa (e.g., Glomeromycetes, Desulfobacterota ) and predicted functions (e.g., denitrification, nitrogen-respiration, sulfate reduction) were associated with differences in plant performance. Finally, combining agrivoltaic systems with targeted soil amendments can enhance crop yield and soil microbial functionality—offering a promising strategy for sustainable agriculture in arid landscapes.

14 SOLAR ENERGY↗

Riparian vegetation shade restoration and loss effects on recent and future stream temperatures

River temperatures are expected to increase this century harming species requiring cold-water habitat unless restoration activities protect or improve habitat availability. Local shading by riparian vegetation can cool water temperatures, but uncertainty exists over the scaling of this local effect to larger spatial extents. Here, we evaluate this issue using a regional spatial stream network temperature model with covariates representing shade effects to predict mean August stream temperatures across 78,195 km of tributaries flowing into the Columbia River in the northwestern United States. We evaluate nine scenarios predicting stream temperatures for three riparian shade conditions (current, restored, and no riparian vegetation) within three different climate periods (2000s, 2040s, and 2080s). Results suggest riparian shade restoration (2000s climate) could decrease mean August stream temperatures by 0.62°C across the study network. Under the same restored shade conditions, temperature predictions for tributaries at their confluence with the Columbia River range from 0.02 to 2.08°C cooler than under current shade conditions. The climate warming effect predicted for the 2040s and 2080s, however, is greater than the cooling effect from restoring riparian shade. Streams less than 10-m bankfull width cooled more frequently with riparian shade restoration. In Oregon, the proportion of fish habitat for salmon and trout rearing and migration that meet temperature numeric water quality criteria could be increased by 20% under restored shade conditions although net habitat declines may still occur in the future. We conclude riparian vegetation restoration could partially mitigate future warming and help maintain cold-water habitats that function as thermal refuges if implemented strategically.

54 ENVIRONMENTAL SCIENCES↗

The Interactions Between Shading and Organic Fertilizer Application on Dry-farmed Tomato Grown Between Photovoltaic Panels

Agrivoltaic systems are mixed systems of solar photovoltaic (PV) panels and agricultural production, where shade from the panels can result in lower evapotranspiration for crops, which is of particular interest for dryland agriculture. Dry-farmed tomato (Solanum lycopersicum) production in the Willamette Valley of Oregon has lower total yields and higher rates of blossom-end rot (BER) than irrigated tomato production, resulting in reduced marketable yields. To determine how dry-farmed ‘Early Girl’ tomato performed in an agrivoltaics system, a trial was conducted at the Valley Creek Solar Project (Salem, OR, USA) in 2020, using three different amendment treatments and three levels of shading from the panels. Amendment treatments were 0N (receiving no fertilizer), 84N (receiving 84 kg·ha −1 N), and 168N (receiving 168 kg·ha −1 N), applied as processed chicken manure. Plants were estimated to receive an irradiance factor of 30%, 76%, and 89% for full-shade, partial-shade, and full-sun treatments respectively. There was an interaction between amendment treatments and shading treatments in their effects on unblemished yield (yield of fruit without BER or sunscald). The optimum fertilizer application for full-shade and partial-shade rows was 84N, the optimum for full-sun rows was 0N. Fertilizing these rows at these rates resulted in an unblemished yield for the aisle of 11.1 t·ha −1 , which was lower than unblemished yields reported in previous experiments and trials in open fields. However, these results are from a single location and a single year, and other solar sites may behave more similar to open-field conditions. Shading from the panels increased average fruit weight and decreased incidence of BER and sunscald, suggesting that crops were less drought stressed. This resulted in similar unblemished yields for the full-shade and full-sun plots at 84N and 168N. Applying fertilizer resulted in higher total yields, smaller average fruit weight, increased BER incidence, and decreased sunscald incidence. The results suggest a possible synergy between dry-farmed tomato production and agrivoltaics, although several concerns remain, including difficulties managing the vegetation under panels, rules restricting PVs on high-value agricultural soils, and the possibility of soil compaction during PV installation.

14 SOLAR ENERGY↗

Impact of shading following installation of agrivoltaic systems on eco-physiological and biochemical attributes of “Howes” cranberry in Massachusetts

Agrivoltaic (AV) systems, which integrate solar energy generation with crop production on the same piece of land, offer a sustainable solution for optimizing land-use efficiency. However, the impact of shading induced by solar panels on crop growth, physiology, and metabolic activities of cranberry is not known. Understanding these interactions is essential for assessing the feasibility of AV systems in cranberry production. In this study we evaluated eco-physiological and biochemical crop responses on a commercial ‘Howes’ cranberry bog grown under an agrivoltaics system using different row spacings in the year immediately following installation. Following installation of fixed tilt solar panels at a height of 3.0 m above the plant canopy, four shading treatments were evaluated: an uncovered control area and row spacings of 9.0 m, 7.0 m, and 5.0 m, corresponding to 30%, 35%, and 37% shading respectively. The shading effect was also evaluated at three different fruit developmental stages (green, blush, and full-red stage). Using microclimate sensors installed in the treatment areas, key eco-physiological and biochemical parameters, including leaf gas exchange, chlorophyll, anthocyanin, and antioxidant content, electrolyte leakage, proline and trehalose accumulation, were assessed. While moderate shading (30% and 35%) alleviated environmental stress, as reflected by improved leaf water status and reduced electrolyte leakage, these same treatments suppressed key physiological and metabolic functions, including photosynthetic activity, carbon reserve accumulation, and the biosynthesis of stress-related osmolytes and antioxidant compounds. Under higher shading (37%), these reductions were even more pronounced, indicating a potential threshold beyond which the benefits of shading are outweighed by declines in assimilate production and secondary metabolism. These findings highlight a trade-off between the stress-mitigating benefits of shading and the alterations in key physiological and metabolic processes under agrivoltaic systems. Minimizing these trade-offs by optimizing row spacing in agrivoltaics systems is critical to maintain cranberry physiological status. Since commercial cranberry is grown as a continuous plant canopy (no interrow spaces for equipment travel), damage caused by the installation process likely impacted crop response evaluated in the first year; multi-year studies are needed to fully understand the dynamics of a dual-use system. Notably, this work provides the first direct measurements of proline, trehalose content, and electrolyte leakage in cranberry grown under AV conditions, offering new insight into their physiological adjustments to shading.

14 SOLAR ENERGY↗

Degradation mechanisms and partial shading of glass-backsheet and double-glass photovoltaic modules in three climate zones determined by remote monitoring of time-series current–voltage and power datastreams

Degradation and partial shading impact the long-term reliability and power production of photovoltaic (PV) modules and power plants. Time-series power (P mp ) and current–voltage (I-V) curve datastreams from PV modules enable a remote diagnostic approach to quantify active degradation mechanisms and identify partial shading. We study three to nine years of these datastreams, including 3.6 million P mp I-V curves and 36 million values, from eight PV modules, four each of double-glass and glass-backsheet module architectures, located in three distinctly different Köppen-Geiger climate zones, to determine the module’s performance loss rates (PLR), identify active degradation mechanisms and power loss modes, along with partial shading by local objects. Considering both module architectures, PLR results indicate that the BSh climate zone is the most aggressive for module degradation, while the Alpine ET zone is the mildest climate. PLR of double-glass modules located in BWh and BSh climate zones are different due to the significantly greater uniform current loss (ΔP Isc ) for double-glass modules in BSh, at a 5% significance level. Power loss for four out of five modules located in the BWh and BSh climates are dominated by uniform current degradation. Statistical analysis of multistep I-V curves detects partial shading experienced by three studied modules with details of the shading profile, the shading Poynting vector diagram for the obstacle’s relative position, shading scenarios, and duration. Lastly, this work demonstrates how remote monitoring and diagnosis of P mp & I-V time-series of modules can provide quantitative operations and maintenance insights into system performance, degradation mechanisms, and shading.

14 SOLAR ENERGY↗

Evaluation of Interior Cellular Shades in a Residential Building

Windows are major contributors to energy demand in residential homes because of their inferior thermal resistance compared with the opaque envelope and sometimes from unwanted solar heat gain. Window attachments can help to mitigate this demand by controlling the solar heat gains and enhancing the thermal resistance of the windows. In this study, the energy savings potential of cellular shades in residential homes is studied using experimental testing and energy simulations. The energy performance of the shading devices was experimentally tested during the heating season from December 2019 to May 2020 with a focus on cellular shades. Five shading devices—three single and two double cellular/cell-in-cell shades—were used to compare the performance with generic horizontal (venetian) blinds using two nearly identical sideby-side rooms in a residential building with their exterior window facing east. Another objective of the experimental testing was to evaluate any impact of the side-channel of the shading device on energy savings. To observe the impact of the side-channels on energy savings, from shades in two of the test cases, cellular shades with side-channels were used. From the experimental testing, daily energy savings in the range of 9% to 23% were observed by considering data from 6 p.m. until 6 a.m. of the next day.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Comprehensive Analysis of Energy and Daylighting Impact of Window Shading Systems and Control Strategies on Commercial Buildings in the United States

Commercial buildings consume approximately 1.9 EJ of energy in the United States, 50% of which is for heating, cooling, and lighting applications. It is estimated that windows contribute up to 34% of the energy used for heating and cooling. However, window retrofits are not often undertaken to increase energy efficiency because of the high cost and disruptive nature of window installation. Highly efficient window technologies would also need shading devices for glare prevention and visual comfort. An automated window shading system with an appropriate control strategy is a technology that can reduce energy demand, maintain occupant comfort, and enhance the aesthetics and privacy of the built environment. However, the benefits of the automated shades currently used by the shading industry are not well studied. The topic merits an analysis that will help building owners, designers and engineers, and utilities make informed decisions using knowledge of the impact of this technology on energy consumption, peak demand, daylighting, and occupant comfort. This study uses integrated daylight and whole-building energy simulation to evaluate the performance of various control strategies that the shading industry uses in commercial office buildings. The analysis was performed for three different vintages of medium office buildings at six different locations in United States. The results obtained show the control strategies enabled cooling energy savings of up to 40% using exterior shading, and lighting energy savings of up to 25%. The control strategies described can help building engineers and researchers explore different control methods used to control shading in actual buildings but rarely discussed in the literature. This information will give researchers the opportunity to investigate potential improvements in current technologies and their performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗