Search NASA⌕ Search

SEARCH · Search NASA

Results for “shape analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Fast-Neutron Spectrometry Using a 3He Ionization Chamber and Digital Pulse Shape Analysis

Digital pulse shape analysis (dPSA) has been used with a Cuttler-Shalev type 3He proportional counter to measure the fast neutron spectra of bare 252Cf and 241AmBe neutron sources. Measurements have also been made to determine the attenuated fast neutron spectra of 252Cf shielded by several materials including water, graphite, liquid nitrogen, magnesium, and tungsten. Rise-time dPSA has been employed using the common rise-time approach for analyzing n +3He ? 1H + 3H ionization events and a new approach has been developed to improve the fidelity of these measurements. Simulations have been performed for the different experimental arrangements and are compared, demonstrating general agreement between the dPSA processed fast neutron spectra and predictions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of the DESI DR2 Ly$α$ forest full-shape analysis

We present the validation of the Dark Energy Spectroscopic Instrument (DESI) Data Release 2 (DR2) Lyman-$α$ (Ly$α$) forest full-shape analysis. This analysis combines three-dimensional Ly$α$ forest auto-correlations and cross-correlations with quasars to extract information from both the baryon acoustic oscillation (BAO) feature and the broadband clustering signal, with primary emphasis on the Alcock-Paczynski (AP) measurement. Compared to the DESI DR1 analysis, the DR2 validation uses substantially larger and more realistic mock datasets, including CoLoRe 2LPT and AbacusSummit Ly$α$ forest simulations. The modeling framework is also improved through analytic marginalization over small scales ($<10$$h^{-1}$Mpc) and the impact of ultraviolet background fluctuations. The validation program was completed prior to unblinding and defines quantitative requirements for the cosmological parameters of interest, which are evaluated using hundreds of mock realizations. We further test the analysis through independent fits to the auto- and cross-correlations, multiple catalog splits, and a broad suite of analysis and modeling variations applied to both mocks and blinded observational data. We find that the BAO and AP parameters satisfy all validation requirements and remain stable across all tests. In contrast, mock studies reveal a significant bias in the inferred growth-rate parameter $fσ_8$, leading us to exclude this measurement from the final analysis. The consistency across mocks, data splits, and robustness tests demonstrates that the DR2 Ly$α$ full-shape analysis provides a reliable and substantially improved broadband AP measurement over previous Ly$α$ forest studies.

Herbold, M. [Chicago U., KICP; Ohio State U.] (ORC↗

Algorithms of pulse shape analysis for Gammasphere under high count rate conditions

The implementation of digital electronics for the multi-detector Gammasphere array has provided an opportunity to perform experiments which exceed the technical capabilities of its analog counterpart. The pulse shape analysis of HPGe detectors is presented for the purpose of determining the γ-ray energy under high-counting rates and short integration times with the aim of improving the data throughput. A revised trapezoidal algorithm is delineated which is able to determine the γ-ray energies during the offline analysis without being constrained by predetermined parameters. The performance of this algorithm is discussed, and compared with that of the analog system. The measured energy resolution meets expectations for operations with high-counting rates and short integration times.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Background Suppression Using Pulse Shape Analysis with a BEGe Detector for Neutrinoless Double Beta Decay Search with GERDA

A pulse shape analysis for distinguishing between double beta decay-like interactions and multiple-scattered photons was performed for the first time using a BEGe-type detector. This discrimination method is included in the research and development for the second phase of the GERDA experiment, since active background suppression techniques are necessary to reach sensitivity for the {sup 76}Ge neutrinoless double beta decay half life of >10{sup 26} years. A suppression of backgrounds in the energy region of interest around the {sup 76}Ge Q{sub {beta}}{sub {beta}} = 2039 keV is demonstrated, with (0.93{+-}0.08)% survival probability for events from {sup 60}Co, (21{+-}3)% for {sup 226}Ra, and (40{+-}2)% for {sup 228}Th. This performance is achieved with (89{+-}1)% acceptance of {sup 228}Th double escape events, which are analogous to double beta decay.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-J-177: A Computational Approach for Determination of Anisotropic PTV Margins Based On Statistical Shape Analysis for Prostate Cancer Radiotherapy

Purpose: Our aim of this study was to propose a computational approach for determination of anisotropic planning target volume (PTV) margins based on statistical shape analysis with taking into account time variations of clinical target volume (CTV) shapes for the prostate cancer radiation treatment planning (RTP). Methods: Systematic and random setup errors were measured using orthogonal projection and cone beam computed tomography (CBCT) images for data of 20 patients, who underwent the intensity modulated radiation therapy for prostate cancer. The low-risk, intermediate-risk, and high-risk CTVs were defined as only a prostate, a prostate plus proximal 1-cm seminal vesicles, and a prostate plus proximal 2-cm seminal vesicles, respectively. All CTV regions were registered with a reference CTV region with a median volume to remove the effect of the setup errors, and converted to a point distribution models. The systematic and random errors for translations of CTV regions were automatically evaluated by analyzing the movements of centroids of CTV regions. The random and systematic errors for shape variations of CTV regions were obtained from covariance matrices based on point distributions for the CTV contours on CBCT images of 72 fractions of 10 patients. Anisotropic PTV margins for 6 directions (right, left, anterior, posterior, superior and inferior) were derived by using Yoda’s PTV margin model. Results: PTV margins with and without shape variations were 5.75 to 8.03 mm and 5.23 to 7.67 mm for low-risk group, 5.87 to 8.33 mm and 5.23 to 7.67 mm for intermediate-risk group, and 5.88 to 8.25 mm and 5.29 to 7.82 mm for highrisk group, respectively. Conclusion: The proposed computational approach could be feasible for determination of the anisotropic PTV margins with taking into account CTV shape variations for the RTP.

60 APPLIED LIFE SCIENCES↗

A new gamma-ray detector, 3-dimension, fast scanning table for pulse-shape analysis

The state-of-the art gamma-ray spectrometers such as AGATA and GRETA are using position sensitive multi-segmented HPGe crystals. Pulse-shape analysis (PSA) allows to retrieve the localisation of the gamma interactions and to perform gamma-ray tracking within germanium. The precision of the localisation depends on the quality of the pulse-shape database used for comparison. The IPHC laboratory developed a new fast scanning table allowing to measure experimental pulse shapes in the whole volume of any crystal. The results of the scan of an AGATA 36-fold segmented tapered coaxial detector are shown here, 48580 experimental pulse shapes are extracted within 2 weeks of scanning. These data will contribute to AGATA PSA performances, but have also applications for gamma cameras or Compton-suppressed detectors. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Hierarchical Optimization-Based Classification of Hyperspectral Images Using Shape Analysis

A new spectral-spatial method for classification of hyperspectral images is proposed. The HSegClas method is based on the integration of probabilistic classification and shape analysis within the hierarchical step-wise optimization algorithm. First, probabilistic support vector machines classification is applied. Then, at each iteration two neighboring regions with the smallest Dissimilarity Criterion (DC) are merged, and classification probabilities are recomputed. The important contribution of this work consists in estimating a DC between regions as a function of statistical, classification and geometrical (area and rectangularity) features. Experimental results are presented on a 102-band ROSIS image of the Center of Pavia, Italy. The developed approach yields more accurate classification results when compared to previously proposed methods.

Classification↗

A comparison of past and present computational methods for shape analysis of double-shell x-ray radiographs

Implosion symmetry is a key requirement in achieving a robust burning plasma in inertial confinement fusion experiments. In double-shell capsule implosions, we are interested in the shape of the inner shell as it pushes on the fuel. Shape analysis is a popular technique for studying said symmetry during implosion. Combinations of filtering and contour-finding algorithms are studied for their promise in reliably recovering Legendre shape coefficients from synthetic radiographs of double-shell capsules with applied levels of noise. A radial lineout max(slope) method when used on an image pre-filtered with non-local means and a variant of the marching squares algorithm are able to recover p 0 , p 2 , and p 4 maxslope Legendre shape coefficients with mean pixel discrepancy errors of 2.81 and 3.06, respectively, for the noisy synthetic radiographs we consider. Here, this improves upon prior radial lineout methods paired with Gaussian filtering, which we show to be unreliable and whose performance is dependent on input parameters that are difficult to estimate.

47 OTHER INSTRUMENTATION↗

A Pulse Shape Analysis Technique for the MAJORANA Experiment

In order to achieve background count rates sufficiently low as to allow the observation of rare events such as neutrinoless double beta (0 ) decay, background suppression techniques are routinely employed. In this paper we present details of a novel Pulse Shape Analysis algorithm which allows single-site events such as 0 decay to be distinguished from multi site background events. The algorithm, which is based on the event by event 2 fitting of experimental signals to a basis data set of unique single site pulse shapes, has been developed through simulation studies and tested experimentally using a Broad Energy Germanium detector. It is found experimentally that the technique is able to successfully identify and reject 99% of multi site events in the single escape peak associated with the gamma decay of 208Tl, whilst maintaining a survival probability of 98% for '0 like' double escape peak events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mode shape analysis using a commercially available peak store video frame buffer

Time exposure photography, sometimes coupled with strobe illumination, is an accepted method for motion analysis that bypasses frame by frame analysis and resynthesis of data. Garden variety video cameras can now exploit this technique using a unique frame buffer that is a non-integrating memory that compares incoming data with that already stored. The device continuously outputs an analog video signal of the stored contents which can then be redigitized and analyzed using conventional equipment. Historically, photographic time exposures have been used to record the displacement envelope of harmonically oscillating structures to show mode shape. Mode shape analysis is crucial, for example, in aeroelastic testing of wind tunnel models. Aerodynamic, inertial, and elastic forces can couple together leading to catastrophic failure of a poorly designed aircraft. This paper will explore the usefulness of the peak store device as a videometric tool and in particular discuss methods for analyzing a targeted vibrating plate using the 'peak store' in conjunction with calibration methods familiar to the close-range videometry community. Results for the first three normal modes will be presented.

Snow, Walter L.↗

DESI DR1 Ly$α$ forest: 3D full-shape analysis and cosmological constraints

We perform an analysis of the full shapes of Lyman-$α$ (Ly$α$) forest correlation functions measured from the first data release (DR1) of the Dark Energy Spectroscopic Instrument (DESI). Our analysis focuses on measuring the Alcock-Paczynski (AP) effect and the cosmic growth rate times the amplitude of matter fluctuations in spheres of $8$$h^{-1}\text{Mpc}$, $fσ_8$. We validate our measurements using two different sets of mocks, a series of data splits, and a large set of analysis variations, which were first performed blinded. Our analysis constrains the ratio $D_M/D_H(z_\mathrm{eff})=4.525\pm0.071$, where $D_H=c/H(z)$ is the Hubble distance, $D_M$ is the transverse comoving distance, and the effective redshift is $z_\mathrm{eff}=2.33$. This is a factor of $2.4$ tighter than the Baryon Acoustic Oscillation (BAO) constraint from the same data. When combining with Ly$α$ BAO constraints from DESI DR2, we obtain the ratios $D_H(z_\mathrm{eff})/r_d=8.646\pm0.077$ and $D_M(z_\mathrm{eff})/r_d=38.90\pm0.38$, where $r_d$ is the sound horizon at the drag epoch. We also measure $fσ_8(z_\mathrm{eff}) = 0.37\; ^{+0.055}_{-0.065} \,(\mathrm{stat})\, \pm 0.033 \,(\mathrm{sys})$, but we do not use it for cosmological inference due to difficulties in its validation with mocks. In $Λ$CDM, our measurements are consistent with both cosmic microwave background (CMB) and galaxy clustering constraints. Using a nucleosynthesis prior but no CMB anisotropy information, we measure the Hubble constant to be $H_0 = 68.3\pm 1.6\;\,{\rm km\,s^{-1}\,Mpc^{-1}}$ within $Λ$CDM. Finally, we show that Ly$α$ forest AP measurements can help improve constraints on the dark energy equation of state, and are expected to play an important role in upcoming DESI analyses.

Cuceu, Andrei [LBL, Berkeley; Chicago U., KICP] (O↗

Mapping octahedral tilts and polarization across a domain wall in BiFeO3 from Z-contrast STEM image atomic column shape analysis

Oxygen octahedral tilts underpin the functionality of a large number of perovskite-based materials and heterostructures with competing order parameters. We show how a precise analysis of atomic column shapes in Z-contrast scanning transmission electron microscopy images can reveal polarization and octahedral tilt behavior across uncharged and charged domain walls in BiFeO3. This method is capable of visualizing octahedral tilts to much higher thicknesses than phase contrast imaging. We find that the octahedral tilt transition across a charged domain wall is atomically abrupt, while the associated polarization profile is diffuse (1.5-2 nm). Ginzburg-Landau theory then allows the relative contributions of polarization and the structural order parameters to the wall energy to be determined.

36 MATERIALS SCIENCE↗

LCP Identification Method based on Pulse Shape Analysis

An improved LCP identification method based on Pulse shape analyses has been designed, the module 'Dual Pulse-Shape Analyzer' has been built and tested and resent experimental results of instrument utilizing have been presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GEOS-1 laser pulse return shape analysis

An attempt has been made to predict the shape of the laser return pulse from the corner cube retroreflectors on the GEOS-1 spacecraft. The study is geometrical only, and neglects factors such as optical interference, atmospheric perturbations, etc. A function giving the intensity of the return signal at any given time has been derived. In addition, figures are given which show the predicted return pulse shape as a function of time, the angle between the beam and the spin axis, and an in-plane angle (designating the orientation of the intersection of the planar waves with the plane of the corner cubes).

Felsentreger, T. L.↗

Onboard Autonomous Rock Shape Analysis for Mars Rovers

In the quest to maximize the scientific return of future robotic missions, it is imperative that our rovers be capable of determining the importance of the science they collect so that they may prioritize the acquisition and relay of that data. As an important step in this process, we present an automated technique to allow a rover to classify the shape and other geologic characteristics of rocks from two-dimensional photographic images and three-dimensional stereographically produced data. Experiments were conducted in the Matlab environment using images returned by JPL's Mars Pathfinder mission. Our method begins by first segmenting the rocks from the background using a combination of image intensity and height data. Various metrics are then used to classify the region's sphericity, roundness, and other geometric properties. Preliminary experiments to determine the most useful metrics were conducted by characterizing the two-dimensional rock shape while the three-dimensional shape was later studied with metrics derived from these two-dimensional techniques. Seven measures were developed and implemented. The performance of each measure was characterized by analyzing imagesfrom the Pathfinder mission and ranking the rocks according to the measured properties. Combined, the measures would provide a tool by which an automated rover could discover a greater amount of information about the data it collects, leading to a more productive mission.

image segmentation↗

Using pulse shape analysis to improve the position resolution of a resistive anode microchannel plate detector

Digital signal processing techniques were employed to investigate the joint use of charge division and risetime analyses for the resistive anode (RA) coupled to a microchannel plate detector (MCP). In contrast to the typical approach of using the relative charge at each corner of the RA, this joint approach results in a significantly improved position resolution. A conventional charge division analysis utilizing analog signal processing provides a measured position resolution of 170 μm (FWHM). By using the correlation between risetime and position we were able to obtain a measured resolution of 92μm (FWHM), corresponding to an intrinsic resolution of 64μm (FWHM) for a single Z-stack MCP detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗