Search NASA⌕ Search

SEARCH · Search NASA

Results for “sheltering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Estimating the urban bias of surface shelter temperatures using upper-air and satellite data. Part 1: Development of models predicting surface shelter temperatures

Multiple regression techniques were used to predict surface shelter temperatures based on the time period 1986-89 using upper-air data from the European Centre for Medium-Range Weather Forecasts (ECMWF) to represent the background climate and site-specific data to represent the local landscape. Global monthly mean temperature models were developed using data from over 5000 stations available in the Global Historical Climate Network (GHCN). Monthly maximum, mean, and minimum temperature models for the United States were also developed using data from over 1000 stations available in the U.S. Cooperative (COOP) Network and comparative monthly mean temperature models were developed using over 1150 U.S. stations in the GHCN. Three-, six-, and full-variable models were developed for comparative purposes. Inferences about the variables selected for the various models were easier for the GHCN models, which displayed month-to-month consistency in which variables were selected, than for the COOP models, which were assigned a different list of variables for nearly every month. These and other results suggest that global calibration is preferred because data from the global spectrum of physical processes that control surface temperatures are incorporated in a global model. All of the models that were developed in this study validated relatively well, especially the global models. Recalibration of the models with validation data resulted in only slightly poorer regression statistics, indicating that the calibration list of variables was valid. Predictions using data from the validation dataset in the calibrated equation were better for the GHCN models, and the globally calibrated GHCN models generally provided better U.S. predictions than the U.S.-calibrated COOP models. Overall, the GHCN and COOP models explained approximately 64%-95% of the total variance of surface shelter temperatures, depending on the month and the number of model variables. In addition, root-mean-square errors (rmse's) were over 3 C for GHCN models and over 2 C for COOP models for winter months, and near 2 C for GHCN models and near 1.5 C for COOP models for summer months.

Epperson, David L.↗

The Development of a Thermally Enhanced Emergency Fire Shelter

Since its founding in 1905, the U.S. Forest Service has been responsible for maintaining public lands. The Forest Service and other public lands agencies respond to an average of 73,000 wildfires per year, and responding firefighters are required to carry a number of safety gear items, including the M2002 emergency fire shelter. The emergency fire shelter is intended to serve as a last resort means of protection in case a firefighter's escape route has been compromised in the face of an approaching flame front. No fire shelter deployment tragedy has been more costly than the 2013 Yarnell Hill fire in Arizona, where 19 members of the Granite Mountain Hotshots perished. After the tragedy at Yarnell Hill, the Forest Service decided to expedite the next redesign cycle of the fire shelter in order to improve its ability to withstand direct contact with flames. Engineers at NASA Langley Research Center have spent the better part of a decade developing flexible thermal materials for use in inflatable aerodynamic decelerators and have demonstrated their performance in the IRVE-2 and IRVE-3 flight programs (Inflatable Reentry Vehicle Experiment). NASA engineers recognized an opportunity to leverage their experience and knowledge with flexible thermal protection systems to potentially improve the fire shelter's resistance to direct flame contact, and have been working directly with the U.S. Forest Service to achieve this goal. They launched the CHIEFS project (Convective Heating Improvement for Emergency Fire Shelters) in 2014. Over the past three years, CHIEFS has screened over 270 unique material layups, and tested over 30 unique full scale shelter concepts in an effort to achieve a game changing improvement to the thermal protection of the fire shelter, while maintaining minimal mass and volume. This paper will discuss CHIEFS' 1st and 2nd generation fire shelter development efforts and test results.

Fody, Joshua M.↗

Eastern Indigo Snake (Drymarchon couperi) Shelter Site Use in Peninsular Florida and Implications for Habitat Conservation

Shelters are critical for many species as protection from predators and extreme temperatures. Successful conservation of reptiles requires understanding both shelter site requirements and availability. The Eastern Indigo Snake (EIS) is endemic to the southeastern United States and is federally listed. Recovery has focused on maximizing unfragmented landscapes, with less attention on fine-scale features such as shelter sites. In the northern EIS range, Gopher Tortoise (Gopherus polyphemus) burrows are used extensively for shelter. Although EIS in peninsular Florida often shelter in tortoise burrows, they also use other shelters where tortoise burrows are scarce or absent. Solely focusing EIS survey and management efforts where Gopher Tortoises are present may overlook occupied habitats and misallocate resources. We investigated the importance of different shelter sites in central Florida using data from radio-tracked EIS. We modeled the use of shelter categories as a function of sex, season, and habitat using Bayesian multinomial generalized linear models. Results showed that EIS in peninsular Florida used Gopher Tortoise burrows across all seasons and habitats. Tortoise burrow use was highest in xeric habitats and lowest in mesic habitats where burrows are most and least abundant, respectively. There was less variability in shelter site use in disturbed habitats and flatwoods. Cool season tortoise burrow use across sexes and habitats in our study was much lower than in southern Georgia. Our results indicate that EIS are less dependent on Gopher Tortoise burrows in peninsular Florida and that suitable habitats with few or no tortoise burrows could still provide conservation value for EIS.

Bayesian hierarchical modeling↗

Analysis of sheltering and evacuation strategies for an urban nuclear detonation scenario.

Development of an effective strategy for shelter and evacuation is among the most important planning tasks in preparation for response to a low yield, nuclear detonation in an urban area. This study examines shelter-evacuate policies and effectiveness focusing on a 10 kt scenario in Los Angeles. The goal is to provide technical insights that can support development of urban response plans. Results indicate that extended shelter-in-place can offer the most robust protection when high quality shelter exists. Where less effective shelter is available and the fallout radiation intensity level is high, informed evacuation at the appropriate time can substantially reduce the overall dose to personnel. However, uncertainties in the characteristics of the fallout region and in the exit route can make evacuation a risky strategy. Analyses indicate that only a relatively small fraction of the total urban population may experience significant dose reduction benefits from even a well-informed evacuation plan.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluating indoor thermal resilience of passive and low-power cooling shelters for outdoor workers in India

India’s 231 million outdoor workers are exposed to deadly heat during heat waves. We report results from a simulation-based study that focuses on passive design of cooling shelters for the hot and dry climate zone of India. The goal is to design a cooler-than-outdoor shelter for outdoor workers’ intermittent rest and recovery from heat stress during their arduous outdoor work, to avoid heat-related morbidities and mortality. Expected indoor thermal conditions in low-cost cooling shelters deploying a range of passive designs and low-power active measures are investigated, consistent with the current Indian standards and practices, located in the city of Jodhpur in western India. Heat resilience of the shelter was measured with the predicted reduction of hazardous hours inside the shelter based on the wet-bulb globe temperature (WBGT) and extended heat index. These measures include improving the building envelope, installing cool roofs, using internal thermal mass, and natural ventilation. Additionally, a low-power active measure of using ventilation fans and ceiling fans is explored. EnergyPlus-based simulation results show that simple, commonly available measures, particularly natural ventilation and ceiling fans, achieve the most significant reductions in overheating danger hours, by 22% and 21%, respectively, while more complex or costly passive strategies yield only marginal additional benefits. Moreover, combined measure packages are identified that can reduce the indoor WBGT by 8 to 10 °C, eliminating overheating danger hours. These findings highlight the critical importance of scalable, low-cost, and easily deployable cooling solutions for developing resilient cooling shelters for vulnerable outdoor workers during heat waves in India.

building performance↗

A Systematic Approach to Developing Sustainable Post-Disaster Shelters in the Southern Region of the United States

This study aims to propose a sustainable shelter design involving energy savings, less environmental impact, and rapid construction. The structural design of the shelter is based on 3D-printing technology. Sustainability assessments, including life cycle analysis (LCA), life cycle energy assessment (LCEA), and energy justice of the designed shelter, were conducted to prove the sustainable shelter design. The outcomes of this study for several scenarios will not only allow decision-makers to design permanent shelters with maximized utilization of limited resources but also help local communities strengthen their ability to recover with minimal outside assistance post-disaster. Furthermore, residents can utilize the sustainable shelter to maintain critical functions, including business continuity and local business in emergencies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of sheltering and evacuation strategies for a Chicago nuclear detonation scenario.

Development of an effective strategy for shelter and evacuation is among the most important planning tasks in preparation for response to a low yield, nuclear detonation in an urban area. Extensive studies have been performed and guidance published that highlight the key principles for saving lives following such an event. However, region-specific data are important in the planning process as well. This study examines some of the unique regional factors that impact planning for a 10 kt detonation in Chicago. The work utilizes a single scenario to examine regional impacts as well as the shelter-evacuate decision alternatives at selected exemplary points. For many Chicago neighborhoods, the excellent assessed shelter quality available make shelter-in-place or selective transit to a nearby shelter a compelling post-detonation strategy.

99 GENERAL AND MISCELLANEOUS↗

Analysis of sheltering and evacuation strategies for a national capital region nuclear detonation scenario.

Development of an effective strategy for shelter and evacuation is among the most important planning tasks in preparation for response to a low yield, nuclear detonation in an urban area. Extensive studies have been performed and guidance published that highlight the key principles for saving lives following such an event. However, region-specific data are important in the planning process as well. This study examines some of the unique regional factors that impact planning for a 10 kT detonation in the National Capital Region. The work utilizes a single scenario to examine regional impacts as well as the shelter-evacuate decision alternatives at one exemplary point. For most Washington, DC neighborhoods, the excellent assessed shelter quality available make shelter-in-place or selective transit to a nearby shelter a compelling post-detonation strategy.

99 GENERAL AND MISCELLANEOUS↗

NUclear EVacuation Analysis Code (NUEVAC) : a tool for evaluation of sheltering and evacuation responses following urban nuclear detonations.

The NUclear EVacuation Analysis Code (NUEVAC) has been developed by Sandia National Laboratories to support the analysis of shelter-evacuate (S-E) strategies following an urban nuclear detonation. This tool can model a range of behaviors, including complex evacuation timing and path selection, as well as various sheltering or mixed evacuation and sheltering strategies. The calculations are based on externally generated, high resolution fallout deposition and plume data. Scenario setup and calculation outputs make extensive use of graphics and interactive features. This software is designed primarily to produce quantitative evaluations of nuclear detonation response options. However, the outputs have also proven useful in the communication of technical insights concerning shelter-evacuate tradeoffs to urban planning or response personnel.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A comparison of lightning and nuclear electromagnetic pulse response of tactical shelters

The internal response (electromagnetic fields and cable responses) of tactical shelters is addressed. Tactical shelters are usually well-shielded systems. Apart from penetrations by signal and power lines, the main leakage paths to the interior are via seams and the environment control unit (ECU) honeycomb filter. The time domain in three-dimensional finite-difference technique is employed to determine the external and internal coupling to a shelter excited by nuclear electromagnetic pulses (NEMP) and attached lightning. The responses of interest are the internal electromagnetic fields and the voltage, current, power, and energy coupled to internal cables. Leakage through the seams and ECU filter is accomplished by their transfer impedances which relate internal electric fields to external current densities. Transfer impedances which were experimentally measured are used in the analysis. The internal numerical results are favorably compared to actual shelter test data under simulated NEMP illumination.

Perala, R. A.↗

Lunar surface operations. Volume 1: Lunar surface emergency shelter

The lunar surface emergency shelter (LSES) is designed to provide survival-level accommodations for up to four astronauts for a maximum of five days. It would be used by astronauts who were caught out in the open during a large solar event. The habitable section consists of an aluminum pressure shell with an inner diameter of 6 ft. and a length of 12.2 ft. Access is through a 4 in. thick aluminum airlock door mounted at the rear of the shelter. Shielding is provided by a 14.9 in. thick layer of lunar regolith contained within a second, outer aluminum shell. This provides protection against a 200 MeV event, based on a 15 REM maximum dose. The shelter is self-contained with a maximum range of 1000 km. Power is supplied by a primary fuel cell which occupies 70.7 cu ft. of the interior volume. Mobility is achieved by towing the shelter behind existing lunar vehicles. It was assumed that a fully operational, independent lunar base was available to provide communication support and tools for set-up and maintenance. Transportation to the moon would be provided by the proposed heavy lift launch vehicle. Major design considerations for the LSES were safety, reliability, and minimal use of earth materials.

Shields, William↗

Deep Space Storm Shelter Simulation Study

Missions outside of Earth's magnetic field are impeded by the presence of radiation from galactic cosmic rays and solar particle events. To overcome this issue, NASA's Advanced Exploration Systems Radiation Works Storm Shelter (RadWorks) has been studying different radiation protective habitats to shield against the onset of solar particle event radiation. These habitats have the capability of protecting occupants by utilizing available materials such as food, water, brine, human waste, trash, and non-consumables to build short-term shelters. Protection comes from building a barrier with the materials that dampens the impact of the radiation on astronauts. The goal of this study is to develop a discrete event simulation, modeling a solar particle event and the building of a protective shelter. The main hallway location within a larger habitat similar to the International Space Station (ISS) is analyzed. The outputs from this model are: 1) the total area covered on the shelter by the different materials, 2) the amount of radiation the crew members receive, and 3) the amount of time for setting up the habitat during specific points in a mission given an event occurs.

Dugan, Kathryn↗

Effectiveness of Urban Shelter-in-Place. III: Commercial Districts

In the event of a toxic chemical release to the atmosphere, shelter-in-place (SIP) is an emergency response option available to protect public health. This paper is the last in a three-part series that examines the effectiveness of SIP at reducing adverse health effects in communities. We model a hypothetical chemical release in an urban area, and consider SIP effectiveness in protecting occupants of commercial buildings. Building air infiltration rates are predicted from empirical data using an existing model. We consider the distribution of building air infiltration rates both with mechanical ventilation systems turned off and with the systems operating. We also consider the effects of chemical sorption to indoor surfaces and nonlinear chemical dose-response relationships. We find that commercial buildings provide effective shelter when ventilation systems are off, but that any delay in turning off ventilation systems can greatly reduce SIP effectiveness. Using a two-zone model, we find that there can be substantial benefit by taking shelter in the inner parts of a building that do not experience direct air exchange with the outdoors. Air infiltration rates vary substantially among buildings and this variation is important in quantifying effectiveness for emergency response. Community-wide health metrics, introduced in the previous papers in this series, can be applied in pre-event planning and to guide real-time emergency response.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Regional Shelter Analysis Methodology

The fallout from a nuclear explosion has the potential to injure or kill 100,000 or more people through exposure to external gamma (fallout) radiation. Existing buildings can reduce radiation exposure by placing material between fallout particles and exposed people. Lawrence Livermore National Laboratory was tasked with developing an operationally feasible methodology that could improve fallout casualty estimates. The methodology, called a Regional Shelter Analysis, combines the fallout protection that existing buildings provide civilian populations with the distribution of people in various locations. The Regional Shelter Analysis method allows the consideration of (a) multiple building types and locations within buildings, (b) country specific estimates, (c) population posture (e.g., unwarned vs. minimally warned), and (d) the time of day (e.g., night vs. day). The protection estimates can be combined with fallout predictions (or measurements) to (a) provide a more accurate assessment of exposure and injury and (b) evaluate the effectiveness of various casualty mitigation strategies. This report describes the Regional Shelter Analysis methodology, highlights key operational aspects (including demonstrating that the methodology is compatible with current tools), illustrates how to implement the methodology, and provides suggestions for future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Regional Shelter Analysis – External Gamma Radiation Exposure Methodology

During normal operations, buildings can protect their occupants from outdoor hazards, including nuclear fallout and other external gamma radiation hazards. Purposeful sheltering can increase this protection. The physics of building protection against external gamma radiation is relatively well understood and we can characterize the protection afforded by individual buildings. However, an operationally efficient, regional-scale methodology to account for building protection effects has not previously been available. Such a method is necessary because (a) the overwhelming majority of the US population is indoors at any given time and (b) a regional-level building protection methodology could better estimate populations truly at risk in emergencies, support improved decision-making (shelter vs. evacuation decisions), and help guide resources towards those most at risk. The Regional Shelter Analysis (RSA) methodology provides a comprehensive, yet operationally efficient method for population-based risk analyses. Specifically, it accounts for (a) building protection distributions (within and among different buildings) and (b) population postures (how people are distributed within and outside of buildings). The RSA method could support a common operating picture by providing user specific results that have the resolution appropriate for individual user’s needs while still being consistent with the information being provided to the other users. The method employs existing building and population databases and is compatible with most modern exposure and injury assessment tools. This report presents the RSA methodology and discusses general operational considerations, with a focus on external gamma radiation exposures. To place this work in the context of prior efforts and current initiatives, a focused literature review is provided that identifies the relevant literature, scientific findings, and datasets from a variety of scientific fields. Other reports in this series will discuss (a) the inhalation exposure pathway and (b) specific RSA implementations.

54 ENVIRONMENTAL SCIENCES↗

Lunar Shelter Habitability Evaluation

Results are reported of an Investigation to determine the capability of pressure suited personnel to deploy lunar shelter/airlock structures install mockup life support, power and miscellaneous equipment within and outside the shelter, and adequately utilize this equipment after installation. Information was obtained on: (1) dimensional requirements for lunar shelter interiors, hatches, and airlocks, (2) limitations imposed on lunar shelter design by pressure suited crewmen, (3) times associated with various work tasks, and (4) redesign recommendations for a lunar stay time extension module (STEM).

Mattingly, G. Samuel↗

Solar Eclipse Effect on Shelter Air Temperature

Decreases in shelter temperature during eclipse events were quantified on the basis of observations, numerical model simulations, and complementary conceptual evaluations. Observations for the annular eclipse on 10 May 1994 over the United States are presented, and these provide insights into the temporal and spatial changes in the shelter temperature. The observations indicated near-surface temperature drops of as much as 6 C. Numerical model simulations for this eclipse event, which provide a complementary evaluation of the spatial and temporal patterns of the temperature drops, predict similar decreases. Interrelationships between the temperature drop, degree of solar irradiance reduction, and timing of the peak eclipse are also evaluated for late spring, summer, and winter sun conditions. These simulations suggest that for total eclipses the drops in shelter temperature in midlatitudes can be as high as 7 C for a spring morning eclipse.

Segal, M.↗