Search NASA⌕ Search

SEARCH · Search NASA

Results for “short circuit current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Reduced-Order Parameterized Short-Circuit Current Model of Inverter-Interfaced Distributed Generators

The short-circuit response of inverter-interfaced distributed generators (IIDGs) is not adequately represented in many conventional protection studies. This paper presents an in-depth analysis of IIDG behavior during grid faults and proposes a more accurate reduced-order parameterized short-circuit current (RPSC) model of inverters. Typical inverter components are thoroughly investigated to identify those that play dominant roles during faults. The paper shows that the current limiter is the dominant factor for the steady-state fault-current of inverter; while the inverter filter along with the severity of the voltage disturbance largely determine the initial transient spike of inverter fault current. The proposed model is low-order and can be used in large scale simulations. The parameters of the proposed RPSC model can be extracted from laboratory experiments without requiring proprietary manufacturer information. The proposed fault-current model is analogous to the well-known synchronous machine model that segregates the inverter fault current into subtransient, transient, and steady-state fault currents. Finally, experimental and simulation tests are presented to validate the model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Trapezoidal grid fingers to reduce shadowing loss and improve short circuit current

Traditional metallic contacts on solar cells can cover a substantial portion of the device area, resulting in shadowing of light that diminishes the amount of current collected. In this paper, we developed trapezoidal electron-beam evaporated Ti/Al front grid fingers on GaAs single-junction solar cells to decrease the optical shadowing and increase the photogenerated current. Here, we observe a high fill factor of 87% at 1-Sun light intensity and we observe no degradation on the open-circuit voltage. The short-circuit current density is found to increase by 0.4 mA/cm 2 when compared to previously demonstrated electroplated Ni/Au front grid fingers, resulting in an efficiency improvement of ~0.8% absolute.

14 SOLAR ENERGY↗

Close-Space Sublimation-Deposited Ultra-Thin CdSeTe/CdTe Solar Cells for Enhanced Short-Circuit Current Density and Photoluminescence

This work describes the complete fabrication process of thin-absorber cadmium selenium telluride/cadmium telluride photovoltaic devices for enhanced efficiency. Here, the process utilizes an automated in-line vacuum system for close-space sublimation deposition which is scalable from fabrication of small area research devices to large-scale modules.

14 SOLAR ENERGY↗

Ensuring a Nuclear Power Plant Safe State Following an EMP Event - Task 7 Deliverable: EMP Testing of Secondary Coupling to Instrumentation Cables

Sandia National Laboratories performed tests to address the potential vulnerability concerns of a coupled High-Altitude Electromagnetic Pulse (HEMP) inducing secondary coupling onto critical instrumentation and control cables in a nuclear power plant, with specific focus on early-time HEMP. Three types of receiving cables in nine configurations were tested to determine transfer functions between two electrically separated cables referenced to the common mode input current on the transmitting cable. One type of transfer function related the input short circuit current and resulting open circuit voltage on the receiving cable. The other transfer function related the input short circuit current and the resulting short circuit current on the receiving cable. A 500 A standard HEMP waveform was input into the transfer functions to calculate peak coupling values on the receiving cables. The highest level of coupling using the standard waveform occurred when cables were in direct contact, with a peak short circuit current of 85 A and open circuit voltage of 9.8 kV, while configurations with separated cables predicted coupling levels of less than 5 A or 500 V.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Real-Time Model-Adaptive Relaying Applied to Microgrid Protection

In microgrids, the short-circuit current magnitude is significantly limited by more than an order of magnitude due to the relatively small inverter-based resources. Commercially available protective devices for distribution cannot reliably protect a microgrid due to their dependence on the magnitude of the fault current. Moreover, overcurrent relays typically cannot function properly for a microgrid because they are incapable of detecting faults and/or performing the coordination between the relays in inverter-based microgrids operated in the islanded mode. This paper proposes a model-adaptive relay designed to adjust the relay curves based on the available generation and the network topology. The proposed method runs a real-time model of the microgrid, which gathers information from the network to calculate the available short-circuit current in the specified node. The fault current from the model is then used for the adaptive algorithm to calculate the relay settings, considering coordination with the downstream fuses and upstream reclosers. This work presents the validation of the proposed method in Hardware-in-the-Loop, in a hardware testbed as well as field deployed in a real microgrid in East-Tennessee.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electronic, direct optical, and phonon-assisted optical properties of 4H Si from first principles

The cubic polytype of silicon (Si) is the most commercialized semiconductor material and finds applications in numerous electronic and optoelectronic devices, such as solar cells. However, recent reports on the synthesis of the hexagonal 4H Si polytype have attracted the attention of the scientific community to understand its functional properties. Here, we report the electronic, vibrational, and optical properties of the 4H Si polytype obtained with predictive first-principles calculations, with an emphasis of phonon-assisted absorption in the indirect regime. Compared to the cubic polytype, 4H Si shows a slightly narrower indirect gap by ∼0.05 eV. The calculated phonon-assisted optical spectra show that 4H Si exhibits a stronger absorption coefficient than cubic Si across the visible and IR spectral regions. We further evaluate the short-circuit current density of textured thin-films. We demonstrate that 4H Si can achieve the same short-circuit current density for a five times thinner film compared to the cubic polytype, which mainly resulted from absorption in the indirect gap regime. Our work demonstrates the advantages of 4H Si for thin-film silicon-based solar-cell applications.

Materials Science↗

Inverter Design with High Short-Circuit Fault Current Contribution to Enable Legacy Overcurrent Protection for Islanded Microgrids

The resiliency offered by a microgrid may be lost if the microgrid is not properly protected during short-circuit faults inside its boundaries. Many studies conclude that protecting microgrids in islanded mode is very challenging due to the limited short-circuit capability of distributed energy resources (DERs). The limited short-circuit capability of DERs typically inhibits the use of reliable and affordable overcurrent protective devices in microgrids. Although extensive research on microgrid protection is available in the literature, to date this research has not led to a cost-effective, commercially available relay that effectively tackles the challenges of microgrid protection. This work proposes hardware modifications to enhance the current contribution of an energy storage inverter with the objective of enabling the use of legacy overcurrent protection for islanded microgrids. This paper demonstrates through experimental results that few modifications are required in the inverter to significantly enhance its current contribution. In this study, a three-phase energy storage inverter was modified to provide three times its rated current during three-phase faults, which proved sufficient current for enough time to enable fuse-relay, and relay-to-relay coordination. The proposed modifications effectively increase the current contribution of the inverter, which is a promising advancement to allow the adoption of overcurrent protective devices for protecting microgrids.

Ferrari Maglia, Max↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of Solar Cells with Trapezoidal Grid Fingers

In concentrator solar cells, traditional metallic contacts cover a substantial portion of the device area, resulting in reflected light that diminishes the amount of current collected. In this paper, we developed trapezoidal front grid fingers to decrease the optical shadowing and the resulting loss of the device short-circuit current. By using a negative photoresist, a thick metal layer can be deposited by metal evaporation. The formation of an organic and metallic reflective deposit under the negative sloped photoresist is observed, though. By removing this deposit, a similar short-circuit current to typical Ni/Au contacts deposited by electrodeposition is obtained. Even though the Ti/Al grid fingers have larger width, they have the same effective shadowing due to the trapezoidal shape. At high concentration, a higher efficiency is obtained as well due to a high fill factor and improved open circuit voltage.

14 SOLAR ENERGY↗

Performance and durability of electrically conductive tape for shingled Si heterojunction technology cells

We report electrically conductive tape (ECT) was characterized and used to assemble shingled cell strings at low temperature to achieve high reliability Pb- and Ag-free interconnections. The volume resistivity for two considered ECTs are 0.13 ± 0.06 mΩ·cm and 0.47 ± 0.20 mΩ·cm and specific contact resistances, 6.85± 2.00 mΩ·cm 2 and 6.30 ± 0.37 mΩ·cm 2 using the emerging IEC 62788-8-1 Technical Specification for assessment of electrically conductive adhesives (ECA). Durability and performance of the technology in glass–glass mini modules were evaluated with temperature cycling, damp heat testing, and combined-accelerated stress testing (CAST). Through temperature cycling (-40°C to 85°C) applying five times the mini module short-circuit current in forward bias and in the multi climate CAST protocol, there was negligible degradation of fill factor after replacing connectors at the modules' cable leads; however, CAST resulted in short circuit current loss attributed to degradation in light collection by the cells, not the ECT. The IEC 61215-2 85°C, 85% relative humidity damp heat testing showed susceptibility of the HJT cells to effects of humidity in the electroluminescence intensity around the module perimeter that degraded power performance by 4% (relative). Contrasting the IEC 61215-2 qualification testing-based damp heat testing with CAST, factors such as the optical stress of CAST may precipitate the degradation of the modules whereas the humidity levels and duration of IEC 61215-2 damp heat testing may lead to excessive levels of humidity diffused into the modules, potentially resulting in degradation that is unrepresentative of the field.

14 SOLAR ENERGY↗

Degradation of Edge-Defined Film-Fed Silicon Glass–Glass Modules on Florida Rooftop After 22 Years

Thin silicon (< 100 μm) adoption can provide significantly lower cost. Kerfless technologies provide thin wafers while preventing material from being wasted. Understanding how this family of processing influences module reliability is important. A set of four edge-defined film-fed growth (EFG) silicon modules from a ten-module system in Florida is measured after 22 years of exposure. Power loss rates of 0.58–0.78% year -1 are measured for three modules, while a rate of 1.32% is measured for a module with severe delamination and corrosion. Short-circuit current degrades between 10.7% and 13.1% for all modules. Further, the losses are primarily optical and recombination based; however, series and shunt resistance effects play a non-negligible role. Pre-existing recombination losses exist but are exacerbated via degradation. Optical losses in short-circuit current are due in part to encapsulant yellowing. Electroluminescence (EL) images display the effects of processing on bulk quality by clearly showing lines of alternating brightness along the wafer length. To the authors’ knowledge, this is the first article displaying suns–V OC data, effective lifetime versus excess carrier density data, and module EL images for EFG silicon-based modules.

36 MATERIALS SCIENCE↗

Value Proposition of UV-Absorbers in PV Module Encapsulation

Various common crystalline silicon cell technologies were exposed to UVA radiation (1.24 Wm-2 nm-1 at 340 nm peak) on the front and back faces at 45 degrees Celsius for periods up to 3000 h, representing about 3 y of solar exposure in Phoenix, Arizona, USA. The resulting degradation of the open-circuit voltage and short-circuit current is presented. Of the various cell types examined, significant levels of degradation were seen in all cases. Less degradation was generally found after UV irradiation of cell fronts and older cell types, whereas a bifacial PERC type exposed on the rear showed about 25% degradation in short circuit current, attributable to lack of a diffused surface field. Selected cells were exposed to UV irradiation with the addition of long pass UV filters to replicate UV-absorbers in encapsulants. Modern cell designs are sensitive to UV-ID because of reduced or eliminated front and back surface field and increased dependence on high quality surface passivation. Single transformation of the independent variable (t, kW h/m^2) could be used to achieve a linear model of the data to extrapolate to 50 y. Solar Advisor Model (SAM) shows appropriate filtering of UV-irradiation can improve LCOE and net present value of plant. Some advanced cell types are seen to be UV-resistant (cell level solutions also exist). Solutions therefore exist on the cell, glass, and encapsulant level. Changes over time in each of these would also need to be considered (solarization, encapsulant browning...).

ENGINEERING,SOLAR ENERGY↗

Understanding the Role of CdTe in Polycrystalline CdSe x Te 1– x /CdTe-Graded Bilayer Photovoltaic Devices

Grading of bandgap by alloying CdTe with selenium to form a CdSe x Te 1–x /CdTe-graded bilayer device has led to a device efficiency over 19%. A CdSe x Te 1–x absorber would increase the short-circuit current due to its lower bandgap but at the expense of open-circuit voltage. It has been demonstrated that adding a CdTe layer at the back of such a CdSe x Te 1–x film reduces the voltage deficit caused by the lower bandgap of absorber from selenium alloying while maintaining the higher short-circuit current. This leads to a photovoltaic device that draws advantage from both materials with an efficiency greater than either of them. In this report there is a detailed account using device data, ultraviolet photoelectron spectroscopy, electron microscopy, and first-principles density functional theory modeling is provided, which shows that CdTe acts as an electron reflector for CdSe x Te 1–x .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhanced charge carrier extraction and transport with interface modification for efficient tin-based perovskite solar cells

Interface modification improves charge carrier extraction in tin-based perovskite solar cells. Tin-based perovskites have become the most promising non-lead perovskites due to their ideal band gap and low toxicity. Although the open circuit voltage of tin-based perovskite solar cells (TPSCs) continues to approach the theoretical value, the short-circuit current is still far from the theoretical value. Here, we describe an interface modification method by regulating the property of hole transport layer, PEDOT:PSS, which improves the surface molecular morphology and the energy level alignment of PEDOT:PSS/perovskite interface. Advanced GIWAXS and IR s-SNOM characterization are conducted to achieve multi-dimensional characterization of nanoscale surface morphology and chemical distribution of PEDOT:PSS. With the multi-attribute optimization, charge carrier extraction and non-radiative recombination are also improved. The resultant TPSCs exhibit a higher power conversion efficiency of 13.32% in compared with the control device of 10.50%, accompanied with an increase in the short-circuit current from 18.10 to 20.50 mA cm −2 and FF from 68.23% to 76.43%. This work demonstrates a reliable strategy for improving charge carrier extraction and device performance for lead-free TPSCs.

Zhao, Zhenzhu↗

Traction Motor Design Trade-Offs with Additively Manufactured Anisotropic Bonded Magnets

Extrusion based big area additive manufacturing (BAAM) has been previously demonstrated for the fabrication of dense anisotropic bonded magnets. This paper reports on design trade-offs when such magnets are employed in a motor designed for electric vehicle applications. An external rotor fractional slot permanent magnet synchronous machine designed with sintered dysprosium free magnets rated for 100kW peak and 50kW continuous power is used as the baseline. The impact of using the bonded BAAM magnets on the motor and inverter volumes, motor loss and cooling systems as well as demagnetization margins is evaluated. It is found that although the motor power density reduces due to the lower energy product of the BAAM magnets, there are other system level benefits including reductions in the cooling system requirement, lower inverter rating and volume, decrease in short circuit current and improved demagnetization marains.

additive manufacturing↗

Improving Frequency Stability and Minimizing Load Shedding Events by Adopting Grid-Scale Energy Storage with Grid Forming Inverters

The upward adoption trend of renewable generation not only means cleaner energy integrated into modern power grids, but also that most new generation sources are based on front-end inverter bridges, used as interfaces to most wind generation and all the solar PV. It is well known that due to their power electronics-based construction rather than rotational shafts, these sources do not provide inertia inherently, nor substantial amounts of short-circuit currents. However, stable energy such as what can be stored in energy storage systems, although interfaced via inverters, can be controlled to respond to system disturbances in a manner that emulates inertial behavior. This paper focuses on the application of such energy storage systems to augment inertia in the island of Puerto Rico. To do so, a user defined inverter model that contains grid forming capabilities and fast frequency response is modeled and integrated into the real transmission system in power flow and dynamics software. Energy storage is then connected to two selected areas so that it not only provides frequency regulation to avoid widespread load shedding events, but also other tangible benefits. The simulated cases suggest that even relatively small energy storage systems can avert load shedding events if adequately placed in the transmission network.

Grid-forming inverters, IBR, Inertia↗

The effect of remnant CdSe layers on the performance of CdSeTe/CdTe photovoltaic devices

Thin film CdTe-based photovoltaic devices have achieved high efficiency above 22 %. The recent improvement in efficiency is due to Se alloying in the CdTe absorbers to form a CdSeTe/CdTe structure. The subsequent band gap grading increases the short circuit current density. The Se can be introduced by depositing a precursor thin film of either CdSe or a CdSeTe alloy and then diffusing the Se into the CdTe during the high temperature cadmium chloride activation process. Using CdSe is preferred because it is easier to control the Se concentration. However, during fabrication of the CdSeTe/CdTe devices, the CdSe thickness needs to be precisely controlled to prevent the retention of a CdSe remnant layer after the activation treatment. Retention of a remnant CdSe layer causes a dramatic reduction in device efficiency. In this work, we show that the reduction in efficiency is caused by a number of factors. The remnant CdSe layer is n-type which moves the position of the p-n junction. Also, it is widely thought that the CdSe remnants are photo-inactive. In this work, we clarify that the individual CdSe grains are actually highly photo-active. However, the grain sizes in the CdSe remnant and the adjacent CdSeTe layer are very small resulting in a high grain boundary area. Although the grain boundaries are passivated with chlorine, cathodoluminescence imaging and electrical measurements show that this is only partially effective. Also, EQE measurements show that the remnant CdSe causes parasitic absorption. Overall, the remnant CdSe layer causes a reduction in short circuit current density and device efficiency. The thickness of the CdSe precursor layer and the cadmium chloride activation process conditions must be precisely optimised to ensure that all the CdSe is consumed and inter-diffused to form the CdSeTe alloy for highest efficiency devices.

CdSe remnant↗

Over 11% Efficient Eco-Friendly Kesterite Solar Cell: Effects of S-Enriched Surface of Cu2ZnSn(S,Se)4 Absorber and Band Gap Controlled (Zn,Sn)O Buffer

For high efficiency kesterite Cu2ZnSn(S,Se)4 (CZTSSe) solar cell, CdS thin film was usually used as a buffer layer. However, due to the toxicity of Cd and pollution problems involved from the solution-based chemical bath deposition, eco-friendly high efficiency CZTSSe solar cell with Cd-free buffer is necessary. As an Cd-free buffer layer, we investigated (Zn,Sn)O (ZTO) film deposited by sputtering method. In order to achieve high power conversion efficiency, we controlled energy band gaps of CZTSSe absorber as well as ZTO buffer, which was required to optimize conduction band offset (CBO) between the absorber and the buffer and to increase open circuit voltage (Voc) and fill factor (FF). The CBO was optimized by controlling the band gap of ZTO. By varying the Sn/(Zn + Sn) ratio and its deposition temperature, band gap of ZTO was successfully adjusted. Experimental and computational calculation results showed that solar cell performance was strongly affected by the CBO between absorber and buffer. Besides CBO matching, larger band gap of ZTO improved short circuit current density (Jsc) with enhanced external quantum efficiency value in blue photon spectrum range. As an additional way to improve power conversion efficiency of solar cell, band graded CZTSSe absorber was developed by using spray-based two-step process. The sprayed CZTSSe film was engineered to have S-enriched surface, which makes surface band gap widened and surface passivated, and resultantly increases Voc, Jsc and fill factor (FF). By controlling band gaps of both CZTSSe absorber and ZTO buffer, we obtained 11.22% environment-friendly CZTSSe solar cell without MgF2 anti-reflection coating.

(Zn↗