Search NASA⌕ Search

SEARCH · Search NASA

Results for “silver activation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Preparation of silver-activated zinc sulfide thin films

Silver improves luminescence and reduces contamination of zinc sulfide phosphors. The silver is added after the zinc sulfide phosphors are deposited in thin films by vapor evaporation, but before calcining, by immersion in a solution of silver salt.

Feldman, C.↗

Preliminary investigation of a sealed, remotely activated silver-zinc battery

Methods necessary to provide a remotely activated, silver zinc battery capable of an extended activated stand while in a sealed condition were investigated. These requirements were to be accomplished in a battery package demonstrating an energy density of at least 35 watt hours per pound. Several methods of gas suppression were considered in view of the primary nature of this unit and utilized the electroplated dendritic zinc electrode. Amalgamation of the electrode provided the greatest suppression of gas at the zinc electrode. The approach to extending the activated stand capability of the remotely activated battery was through evaluation of three basic methods of remote, multi-cell activation; 1) the electrolyte manifold, 2) the gas manifold and 3) the individual cell. All three methods of activation can be incorporated into units which will meet the minimum energy density requirement.

Wheat, C. G.↗

Twin Knudsen Cell Configuration for Activity Measurements by Mass Spectrometry

A twin Knudsen cell apparatus for alloy activity measurements by mass spectrometry is described. Two Knudsen cells - one containing an alloy and one containing a pure component - are mounted on a single flange and translated into the sampling region via a motorized x-y table. Mixing of the molecular beams from the cells is minimized by a novel system of shutters. Activity measurements were taken on two well-characterized alloys to verify the operation of the system. Silver activity measurements are reported for Ag-Cu alloys and aluminum activity measurements are reported for Fe-Al alloys. The temperature dependence of activity for a 0.474 mol fraction Al-Fe alloy gives a partial molar heat of aluminum. Measurements taken with the twin cell show good agreement with literature values for these alloys.

Jacobson, N. S.↗

Anisotropy of the neutron fluence from a plasma focus.

The fluence of neutrons from a plasma focus was measured by gamma spectrometry of an activated silver target. This method results in a significant increase in accuracy over the beta-counting method. Multiple detectors were used in order to measure the anisotropy of the fluence of neutrons. The fluence was found to be concentrated in a cone with a half-angle of 30 deg about the axis, and to drop off rapidly outside of this cone; the anisotropy was found to depend upon the total yield of neutrons. This dependence was strongest on the axis. Neither the axial concentration of the fluence of neutrons nor its dependence on the total yield of neutrons is explained by any of the currently proposed models. Some other explanations, including the possibility of an axially distributed source, are considered.

Lee, J. H.↗

Antibacterial Activity of Silver-Graphene Quantum Dots Nanocomposites Against Gram-Positive and Gram-Negative Bacteria

The invention provides a composite of silver nanoparticles decorated with graphene quantum dots (Ag-GQDs) using pulsed laser synthesis. The nanocomposites were functionalized with polyethylene glycol (PEG). A concentration of 150 .mu.g/mL of Ag-GQDs, a non-toxic level for human cells, exhibits strong antibacterial activity against both Gram-Positive and Gram-Negative Bacteria.

Habiba, Khaled↗

Development of an all-metal thick-film cost-effective metallization system for solar cells

Screened electrodes made from fluorocarbon activated copper paste and silver fluoride activated copper paste, tape adhesion and scratch tests were studied. Experiments were conducted with variations in past parameters, firing conditions, including gas ambients, furnace furniture, silicon surface and others. A liquid medium intended to provide transport during the carbon fluoride decomposition, is incorporated in the paste.

Ross, B.↗

Silver Foam A Long-Term Passive Biocide for Potable Water Systems: 2020 Update

A spacecraft water disinfection system suitable for extended length space exploration missions should prevent or control the growth of microbes, prevent or limit biofilm formation, and prevent microbiologically-influenced corrosion. In addition, the system should have minimal maintenance requirements, the effluent should be chemically compatible with all materials in contact with the water, be safe for human consumption, and suitable to be shared across international spacecraft platforms and mission architectures. Silver ions are a proven broad spectrum biocide and the chosen potable water biocide for future exploration missions. The leading technology for actively dosing silver in future water systems is based on electrolytic production. Several challenges remain with this approach which have prompted additional investigations into alternative dosing techniques. Control-release technology is an attractive option for developing a high-reliability passive silver dosing device. This paper describes the development of a nanoparticle (NP)/polyurethane (PU) composite foam for the controlled release of silver ions, and is intended to build upon the 2019 International Conference on Environmental Systems (ICES) paper of the same name. In this paper, the technical background and results from the updated silver chloride (AgCl) NP/PU composite foam synthesis and property testing is provided. The ultimate goal of the project is to develop a stable and reliable passive dosing silver ion release device for use in future spacecraft potable water systems.

Irwin, Tesia D.↗

Silver Foam: A Novel Approach for Long-Term Passive Dosing of Biocide in Spacecraft Potable Water Systems

A spacecraft water disinfection system suitable for extended length space exploration should prevent or control the growth of microbes, prevent or limit biofilm formation, and prevent microbiologically influenced corrosion. In addition, the system should have minimal maintenance requirements,should be chemically compatible with all materials in contact with the water, be safe for human consumption, and suitable to be shared across international spacecraft platforms and mission architectures. Silver ions are a proven broad-spectrum biocide under consideration as a potable water biocide for future exploration missions. The leading technology for actively dosing silver in future water systems is based on electrolytic production. Several challenges remain with this approach that have prompted additional investigations into alternative dosing techniques. Control-release technology is an attractive option for developing a high-reliability passive silver dosing device. This paper describes the development of a silver chloride (AgCl) nanoparticle (NP)/polyurethane (PU) composite foam for the controlled release of silver ions, and is intended to build upon the 2019 International Conference on Environmental Systems (ICES) paper number 272.This paper provides the technical background and results from the updated AgClNP/PU composite foam (AgFoam) synthesis and property testing. The ultimate goal of the project is to develop a stable and reliable passive dosing silver ion release device for use in future spacecraft potable water systems.

Tesia Dawn Irwin↗

Photographic image intensification by autoradiography

Images on developed photographic emulsions can be significantly intensified by making the image silver radioactive and exposing a second emulsion to this radiation. Because the print, an autoradiograph, reproduces the original with significant increases in density and contrast, the method can be used to enhance underexposed emulsions and to increase the limits of photographic detection. This paper reports a new, practical chemical method for activating the silver, using thiourea labeled with sulfur-35, a process convenient for use in photographic laboratories. Speed increases of 13 and contrast increases of 18 were achieved with Kodak Plus-X film in this initial phase.

Askins, B. S.↗

Water Filter

A compact, lightweight electrolytic water sterilizer available through Ambassador Marketing, generates silver ions in concentrations of 50 to 100 parts per billion in water flow system. The silver ions serve as an effective bactericide/deodorizer. Tap water passes through filtering element of silver that has been chemically plated onto activated carbon. The silver inhibits bacterial growth and the activated carbon removes objectionable tastes and odors caused by addition of chlorine and other chemicals in municipal water supply. The three models available are a kitchen unit, a "Tourister" unit for portable use while traveling and a refrigerator unit that attaches to the ice cube water line. A filter will treat 5,000 to 10,000 gallons of water.

Source record↗

Status of the NASA Space Power Program

The NASA Space Power Research and Technology Program has the objective to provide the technological basis for satisfying the nation's future needs regarding electrical power in space. The development of power sources of low mass and increased environmental resistance is considered. Attention is given to advances in the area of photovoltaic energy conversion, improved Ni-Cd battery components, a nickel-hydrogen battery, remotely activated silver-zinc and lithium-water batteries, the technology of an advanced water electrolysis/regenerative fuel cell system, aspects of thermal-to-electric conversion, environmental interactions, multi-kW low cost systems, and high-performance systems.

Mullin, J. P.↗

Thermal and oxidative degradation studies of formulated C-ethers by gel-permeation chromatography

Gel-permeation chromatography was used to analyze C-ether lubricant formulations from high-temperature bearing tests and from micro-oxidation tests. Three mu-styragel columns (one 500 and two 100 A) and a tetrahydrofuran mobile phase were found to adequately separate the C-ether degradation products. The micro-oxidation tests yielded degradation results qualitatively similar to those observed from the bearing tests. Micro-oxidation tests conducted in air yielded more degradation than did tests in nitrogen. No great differences were observed between the thermal-oxidative stabilities of the two C-ether formulations or between the catalytic degradation activities of silver and M-50 steel. C-ether formulation I did yield more degradation than did formulation II in 111- and 25-hour bearing tests, respectively.

Jones, W. R., Jr.↗

Automatically activated, 300 ampere-hour silver-zinc cell

A prototype silver zinc cell is reported for which the electrolyte is being stored in a separate tank; the cell is being activated when additional power is required by collapsing the neoprene bellows container and thus forcing the electrolyte into cell through a plastic connection. A solar array is proposed as main power source for the flow actuator.

Hennigan, T. J.↗