Search NASA⌕ Search

SEARCH · Search NASA

Results for “silver ion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Silver ion bactericide system

Description of a preliminary flight prototype system which uses silver ions as the bactericide to preserve sterility of the water used for human consumption and hygiene in the Space Shuttle Orbiter. The performance of silver halide columns for passively dosing fuel cell water with silver ions is evaluated. Tests under simulated Orbiter mission conditions show that silver ion doses of 0.05 ppm are bactericidal for Pseudomonas aeruginosa and Type IIIa, the two bacteria found in Apollo potable water systems. The design of the Advance Prototype Silver Ion Water Bactericide System now under development is discussed.

Jasionowski, W. J.↗

Silver Ion Biocide Delivery System for Water Disinfection

U.S. space exploration missions have long considered returning to the Moon and exploration of Mars that challenge life support systems. For these long duration missions, there is interest in replacing the iodine water treatment system with ionic silver, a proven biocide. For long duration exploration missions, it is imperative that an effective biocide be used that prevents microbial growth, biofilm formation, and microbially induced corrosion in the water storage and distribution systems while minimizing logistical supply requirements associated with the biocide delivery system. Two biocide delivery systems have been developed that electrochemically produce silver ions for disinfecting water throughout the water storage and distribution system. One system uses a newly developed hybrid micro-filtration and ion-exchange membrane to produce an abundance of silver ions at the 1000 ppb level upstream in the water distribution system to prevent biofilm growth. This is followed by a downstream collection module that electrochemically removes these silver ions before the water is discharged. Another approach uses a membraneless reactor to produce a 1000 ppb silver ion concentration level that also has a mechanically driven electrode cleaning mechanism that removes oxide films ensuring long life operation. By maintaining a sufficiently high level of silver ions throughout the water storage and distribution system, biofilm formation is suppressed. This approach overcomes present concerns where spurious silver deposition occurs on the container and flow line surfaces thus lowering the silver ion concentration to unsatisfactory disinfection levels.

Slote, Benjamin M.↗

Preliminary flight prototype silver ion monitoring system

The design, fabrication, and testing of a preliminary flight prototype silver ion monitoring system based on potentiometric principles and utilizing a solid-state silver sulfide electrode paired with a pressurized double-junction reference electrode housing a replaceable electrolyte reservoir is described. The design provides automatic electronic calibration utilizing saturated silver bromide solution as a silver ion standard. The problem of loss of silver ion from recirculating fluid, its cause, and corrective procedures are reported. The instability of the silver sulfide electrode is discussed as well as difficulties met in implementing the autocalibration procedure.

Brady, J.↗

A silver ion water sterilization system

Small amounts of silver are incorporated in mixture of ion exchange resins, and water passing through this mixture is thus exposed to silver ion concentration. System is useful in self-contained water systems except city water systems where residual chlorine level is stipulated.

Parry, E. P.↗

Electrolytic silver ion cell sterilizes water supply

Electrolytic water sterilizer controls microbial contamination in manned spacecraft. Individual sterilizer cells are self-contained and require no external power or control. The sterilizer generates silver ions which do not impart an unpleasant taste to water.

Albright, C. F.↗

Advance prototype silver ion water bactericide system

An advance prototype unit was designed and fabricated to treat anticipated fuel cell water. The unit is a single canister that contains a membrane-type prefilter and a silver bromide contacting bed. A seven day baseline simulated mission test was performed; the performance was satisfactory and the effluent water was within all specifications for potability. After random vibrations another seven day simulated mission test was performed, and results indicate that simulated launch vibrations have no effects on the design and performance of the advanced prototype. Bench tests and accelerated breadboard tests were conducted to define the characteristics of an upgraded model of the advance prototype unit which would have 30 days of operating capability. A preliminary design of a silver ion generator for the shuttle orbiter was also prepared.

Jasionowski, W. J.↗

Mitigation of Silver Ion Loss from Solution by Polymer Coating of Metal Surfaces

Spacecraft potable water systems require a biocidal agent that effectively provides both immediate and residual disinfection over long periods of time. Ionic silver (Ag+) is a leading candidate for this application, but suffers from rapid concentration loss due interactions with the metal storage containers and tubing. In order to maintain biocidal efficacy in systems with long periods of dormancy and to reduce the required rate of Ag+ injection, it is necessary to develop alternative materials and coatings for certified metal alloys that significantly reduce the Ag+ loss. In this work, we investigate the performance of two unusual polymers, Teflon AF 2400 and parylene-AF4, as barrier coatings under immersion in 400 ppb Ag+. We show that 25 m-thick parylene-AF4 is a promising coating with Ag+ losses similar to PTFE. Key challenges with this material include maintenance of adhesion under long-term immersion and control of deposition during the internal coating of high-aspect ratio tubing. Solutions to these problems may including surface structuring of substrates for mechanical anchoring or an alternative parylene-C chemistry (with more stable adhesion), and dynamic spatio-temporal control of substrate temperature, respectively.

water↗

Mitigation of Silver Ion Loss from Solution by Polymer Coating of Metal Surfaces, Part II

“Spacecraft potable water systems require a biocidal agent that effectively provides both immediate and residual disinfection over long periods of time. Ionic silver (Ag+) is a leading candidate for this application, but suffers from rapid concentration loss due to interactions with the metal storage containers and tubing. In order to maintain biocidal efficacy in systems with long periods of dormancy and to reduce the required rate of Ag+ injection, it is necessary to develop alternative materials and coatings for certified metal alloys that significantly reduce the Ag+loss.”1In this work, we continue our investigation of vapor-deposited parylene (AF4, and now C) polymers as conformal barrier coatings under long-term (ca. 1-year) immersion in ca. 400 ppb Ag+. The performanceof internal coatings in tubing/two-ferrule fitting systems is characterized. We report successful “aging” and high concentration Ag+pretreatment of parylene coatings for quantitative reduction of Ag+loss rates. In addition, we observe long-term blister-free adhesion of mechanically anchored parylene-AF4 on nano-structured Ti-6Al-4V alloy and chemically bonded parylene-C on 316L stainless steel. Finally, we report preliminary experiments with mechanical and chemical anchoring of laboratory-deposited parylene-C on 316L.

Silver↗

Preliminary Testing of Electrolytic Silver Ion Generation for Spacecraft Potable Water Systems

Anodic dissolution of silver electrodes, or “silver electrolysis,” is being investigated as a means of imparting biocidal silver into potable water on exploration spacecraft. This method of water disinfection is used commercially in hospitals and marine vessels, but the spacecraft application poses unique challenges such as low water conductivity, increased importance of electrode longevity, and an interface with other systems that may be sensitive to any particles released in the electrolysis process. Testing has shown that due to the low conductivity of the water, the electroactive area of the cell can be scaled linearly to achieve a target electrolysis current despite the general non-linearity of electrochemical systems. More importantly, however, the low conductivity dictates that a large electroactive area and minimal electrode gap be employed in the design. Furthermore, thermodynamic considerations suggest that a low applied voltage is necessary to avoid undesired electrode reactions that could negatively impact long-term performance. Preliminary testing of long-term electrode health suggests that anodic oxide formation may not present as significant a challenge as anticipated; however, further testing in a system closed to the atmosphere is required to rule out the influence of atmospheric CO2 on the pH of the process water. Comparison of filtered and unfiltered silver concentration measurements indicates that release of particles larger than 0.2 μm was negligible in this preliminary test. A test article has been developed to facilitate further testing of silver electrolysis, which continues to be a candidate technology for spacecraft potable water disinfection.

silver↗

Mitigation of Silver Ion Loss from Solution by Polymer Coating of Metal Surfaces, Part IV

Ionic silver (Ag+) biocide is a leading candidate to provide residual microbial control in spacecraft potable water systems, but suffers from rapid concentration loss due to interactions with the metallic storage containers and tubing. One approach to resolve this problem is the coating of metal surfaces with an inert barrier film. In previous reports, we have described our investigations addressing Ag+ loss mitigation and adhesion performance of parylene barrier coatings on coupons of several metal alloys and 316Ltubing under static immersion. In such conditions, parylene-C and -AF4 coatings have shown excellent Ag+loss mitigation and mixed long-term adhesion performance, depending on parylene species and substrate surface chemistry/structure. In Part IV of this series, we report on our work to investigate the performance of parylene-C barrier coatings, under more challenging and realistic conditions, in order to evaluate potential suitability for use. The resilience and associated Ag+ loss with Parylene-C coating on½” (12.7 mm)316L tubing and fittings under medium-term immersion and repeated fitting dis/reassembly were investigated. Potential mechanical challenges to barrier coatings in spacecraft potable water systems were investigated, with two main focuses being identified: liquid flow/pressure cycling in tubing and cyclic operation of bellows in positive-expulsion storage tanks. Two corresponding testbeds for experimental characterization of coating performance were developed. In the Flow/Pressure Testbed System, Ag+ solution will be pumped through internally coated 316L tubing, with optional pressure cycling. In the Bellows Tank Testbed System, an internally coated edge-welded 316L bellows containing Ag+ solution will be cyclically extended and compressed, analogous to the operation of bellows tanks used for potable water storage and delivery on the International Space Station. The design and operation of these testbeds are described. Finally, the Ag+ adsorption and saturation behaviors of Kalrez and Viton, for potential use as seal materials in fittings and other connections, were characterized in limited experiments.

mitigation↗

Mitigation of Silver Ion Loss from Solution by Polymer Coating of Metal Surfaces, Part IV

“Spacecraft potable water systems require a biocidal agent that effectively provides both immediate and residual disinfection over long periods of time. Ionic silver (Ag+) is a leading candidate for this application, but suffers from rapid concentration loss due to interactions with the metallic storage containers and tubing. In order to maintain biocidal efficacy in systems with long periods of dormancy and to reduce the required rate of Ag+ injection, it is necessary to develop alternative materials and coatings for certified metal alloys that significantly reduce the Ag+ loss.” In previous reports, we have described our investigations addressing Ag+ loss mitigation and adhesion performance of parylene barrier coatings on coupons of several metal alloys and 316L tubing under static immersion. In such conditions, parylene-C and AF4 coatings have shown excellent Ag+ loss mitigation performance, and mixed long-term adhesion performance, depending on parylene species and substrate surface chemistry/structure. In Part IV of this series, we begin to address the performance of parylene-C barrier coatings under more challenging and realistic conditions, in order to evaluate potential suitability in flight systems. Using two testbeds, we characterized coating performance under dynamic mechanical operation. In the Flow/Pressure Testbed System, Ag+ solution is pumped through internally coated 316L tubing, with optional pressure cycling. In the Bellows Tank Testbed System, an internally coated edge-welded 316L bellows containing Ag+ solution is cyclically extended and compressed, analogous to the operation of bellows tanks used for potable water storage and delivery on the International Space Station. Periodic determinations of Ag+ loss with testbed cycling/time and visual observation of the parylene-C coatings were conducted. In addition, we characterized parylene-C coating resilience and Ag+ loss with 316L tubing and multiple fitting types under long-term immersion and repeated fitting dis/reassembly.

Lance Dean Delzeit↗

Preliminary flight prototype silver ion monitoring system, addendum

A number of electrode fabrication techniques are investigated, to achieve an electrode meeting shuttle mission requirements for functional life and stability as well as accuracy and precision of measurement. The instability of a silver bromide column when employed in a closed loop calibration scheme is discussed.

Wilson, R. I.↗

Synthesis of Thick Hg x Cd 1– x Se Nanoplatelets by Cation Exchange Catalyzed by Silver Ions, Showing Amplified Spontaneous Emission

II-VI semiconductor nanoplatelets have emerged as promising candidates for various applications, owing to their tunable optical properties dictated by their thickness and compositions. In the realm of infrared technology, mercury chalcogenides stand out as particularly promising materials for optoelectronic applications. However, the direct synthesis of 2D particles in this category remains challenging, thus prompting the exploration of alternative methods such as cation exchange. Here, we demonstrate that the cation exchange process from cadmium to mercury can be effectively catalyzed by monovalent Ag + cations. Further, this catalysis facilitates the formation of alloyed Hg x Cd 1-x Se nanoplatelets with tunable optical properties, with the photoluminescence peak ranging from 1.23 eV for the thinnest three-monolayer (ML) nanoplatelets to 0.92 eV for the thickest 7 ML nanoplatelets. The Ag + ions reduce the activation energy of the cation exchange process by a factor of 2, enabling enhanced penetration of mercury atoms deep into the native CdSe nanoplatelets. Moreover, these nanoplatelets exhibit optical gain in the infrared spectrum, including the 1.3 μm telecommunication band, with a fluence threshold at 80 K of 50 μJ∙cm -2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of silver ions (Ag+) on contractile ring function and microtubule dynamics during first cleavage in Ilyanassa obsoleta

The terminal phase of cell division involves tight constriction of the cleavage furrow contractile ring, stabilization/elongation of the intercellular bridge, and final separation of the daughter cells. At first cleavage, the fertilized eggs of the mollusk, Ilyanassa obsoleta, form two contractile rings at right angles to each other in the same cytoplasm that constrict to tight necks and partition the egg into a trefoil shape. The cleavage furrow contractile ring (CF) normally constricts around many midbody microtubules (MTs) and results in cleavage; the polar lobe constriction contractile ring (PLC) normally constricts around very few MTs and subsequently relaxes without cleavage. In the presence of Ag+ ions, the PLC 1) begins MT-dependent rapid constriction sooner than controls, 2) encircles more MTs than control egg PLCs, 3) elongates much more than control PLCs, and 4) remains tightly constricted and effectively cleaves the polar lobe from the egg. If Ag(+)-incubated eggs are returned to normal seawater at trefoil, tubulin fluorescence disappears from the PLC neck and the neck relaxes. If nocodazole, a drug that depolymerizes MTs, is added to Ag(+)-incubated eggs during early PLC constriction, the PLC is not stabilized and eventually relaxes. However, if nocodazole is added to Ag(+)-incubated eggs at trefoil, tubulin fluorescence disappears from the PLC neck but the neck remains constricted. These results suggest that Ag+ accelerates and gradually stabilizes the PLC constriction by a mechanism that is initially MT-dependent, but that progressively becomes MT-independent.

Non-NASA Center↗

Efficacy of copper and silver ions with iodine in the inactivation of Pseudomonas cepacia

Alternatives to chlorination of water have been sought for reasons which include trihalomethane formation, possible bacterial regrowth, the high concentrations of chlorine required in certain circumstances, and the taste, odour and bodily irritation in chlorine-treated water. Electrolytically generated Cu and Ag ions at low levels, in addition to very low chlorine concentrations, have been suggested as an alternative to routine chlorination. We have examined the combination of Cu and Ag ions with low levels of iodine. Pseudomonas cepacia was grown either in rich medium or under nutrient restriction prior to disinfection. Survival of the organism and its ability to regrow after treatment as well as the effects of varying buffers, metal ion and iodine concentrations were determined. Low concentrations of metal ions (100 ppb Cu and 11 ppb Ag) and iodine (200 ppb) were more effective than either metal ions or iodine alone against Ps. cepacia grown on rich agar or in low nutrient buffer. After iodination, buffer-grown suspensions recovered to their original cell concentrations within 7 d. When Cu and Ag ions were used with or without iodine, regrowth was prevented. The results show that low concentrations of Cu and Ag in combination with iodine permit effective disinfection of bacteria after cultivation on either rich media or under nutrient restriction. These results, along with published data, suggest that the combination of these metals with halogenation may have applications in the disinfection of both recreational and potable water.

NASA Discipline Environmental Health↗