Search NASA⌕ Search

SEARCH · Search NASA

Results for “simultaneous operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Design of a communications system for multiple telemetry data channels operating simultaneously with a coherent turn-around ranging channel

This paper presents a simple technique to design a phase-modulated residual carrier communications link for optimum performance. The emphasis is on two data channels which are operated simultaneously with a ranging signal. The data channels employ PCM/PM and PCM/PSK/PM modulation schemes for high and low data rate channels, respectively. The technique proposed here selects the optimum (1) subcarrier frequency to minimize the interference between the two data channels, and (2) modulation indices for optimum balance of power between the two telemetry data channels and the coherent turn around ranging channel. The selected set of optimum modulation indices will allow for the specified bit error rate (BER) degradations in the two data channels. Although this technique is proposed to optimize the performance degradation for two data channels, generalizations can be made for more than two data channels.

Nguyen, Tien M.↗

Advantages of tandem versus simultaneous operation: The case of isomerization/hydrogenation of terpinolene epoxide to Terpinen-4-ol using a Ni/TiO 2 -SiO 2 bifunctional catalyst

The conversion of terpinolene epoxide to terpinen-4-ol is a desirable chemical transformation for the production of a valuable intermediate. Here this report describes a one-pot, two-step system for the reaction that uses a bifunctional Ni/TiO 2 -SiO 2 catalyst with isomerization and hydrogenation capabilities. The TiO 2 -SiO 2 serves to isomerize the starting epoxide. The Ni component works to hydrogenate the allylic double bond. The tandem system achieves a high 64% yield of terpinen-4-ol. X-ray diffraction analysis showed that TiO 2 -SiO 2 was a mixed binary oxide, and Fourier transform infrared spectroscopy of adsorbed pyridine suggested that acid sites were mainly Lewis acid sites. Electron microscopy showed that the Ni/TiO 2 -SiO 2 catalyst consisted of spherical particles comprising a titanosilicate phase with highly dispersed zero-valent Ni or anatase on the surface. Additionally, there was strong interaction between Ni and the TiO 2 -SiO 2 mixed oxides. Control kinetic experiments demonstrated that the tandem use of the catalysts was more effective than simultaneous operation.

42 ENGINEERING↗

Simultaneous operation of two soft x-ray free-electron lasers driven by one linear accelerator

Extreme-ultraviolet to x-ray free-electron lasers (FELs) in operation for scientific applications are up to now single-user facilities. While most FELs generate around 100 photon pulses per second, FLASH at DESY can deliver almost two orders of magnitude more pulses in this time span due to its superconducting accelerator technology. This makes the facility a prime candidate to realize the next step in FELs—dividing the electron pulse trains into several FEL lines and delivering photon pulses to several users at the same time. Hence, FLASH has been extended with a second undulator line and self-amplified spontaneous emission (SASE) is demonstrated in both FELs simultaneously. Here, FLASH can now deliver MHz pulse trains to two user experiments in parallel with individually selected photon beam characteristics. First results of the capabilities of this extension are shown with emphasis on independent variation of wavelength, repetition rate, and photon pulse length.

47 OTHER INSTRUMENTATION↗

Simultaneous operation of three CCN counters and an isothermal haze chamber at the 1980 International CCN Workshop

Four devices were operated for the detection and characterization of cloud condensation nuclei (CCN) and fog condensation nuclei (FCN). In chronological order of development, the CCN devices are the conventional continuous-flow diffusion chamber (CFD), the rapid-cycle CCN spectrometer, and the instantaneous CCN spectrometer. The FCN detection device is an isothermal haze chamber (IHC). These four instruments are discussed and general comments on their performance at the workshop are given.

Hudson, J. G.↗

Feasibility of simultaneous operation of passive remote microwave sensors and active services occupying adjacent frequency bands

To ensure proper sensor operations, it is necessary to understand the situation of potential interference to sensors due to active equipment sharing common frequency bands as well as equipment occupying adjacent bands. The feasibility of sharing common frequency bands between passive sensors and other active services was analyzed. Potential interference to sensors due to equipment in bands adjacent to sensor frequency bands is examined and criteria to avoid interference is developed.

Sue, M. K.↗

Crew Field Notes: A New Tool for Planetary Surface Exploration

The Desert Research and Technology Studies (DRATS) field tests of 2010 focused on the simultaneous operation of two rovers, a historical first. The complexity and data volume of two rovers operating simultaneously presented significant operational challenges for the on-site Mission Control Center, including the real time science support function. The latter was split into two "tactical" back rooms, one for each rover, that supported the real time traverse activities; in addition, a "strategic" science team convened overnight to synthesize the day's findings, and to conduct the strategic forward planning of the next day or days as detailed in [1, 2]. Current DRATS simulations and operations differ dramatically from those of Apollo, including the most evolved Apollo 15-17 missions, due to the advent of digital technologies. Modern digital still and video cameras, combined with the capability for real time transmission of large volumes of data, including multiple video streams, offer the prospect for the ground based science support room(s) in Mission Control to witness all crew activities in unprecedented detail and in real time. It was not uncommon during DRATS 2010 that each tactical science back room simultaneously received some 4-6 video streams from cameras mounted on the rover or the crews' backpacks. Some of the rover cameras are controllable PZT (pan, zoom, tilt) devices that can be operated by the crews (during extensive drives) or remotely by the back room (during EVAs). Typically, a dedicated "expert" and professional geologist in the tactical back room(s) controls, monitors and analyses a single video stream and provides the findings to the team, commonly supported by screen-saved images. It seems obvious, that the real time comprehension and synthesis of the verbal descriptions, extensive imagery, and other information (e.g. navigation data; time lines etc) flowing into the science support room(s) constitute a fundamental challenge to future mission operations: how can one analyze, comprehend and synthesize -in real time- the enormous data volume coming to the ground? Real time understanding of all data is needed for constructive interaction with the surface crews, and it becomes critical for the strategic forward planning process.

Horz, Friedrich↗

Integrating a Microwave Radiometer into Radar Hardware for Simultaneous Data Collection Between the Instruments

The conventional method for integrating a radiometer into radar hardware is to share the RF front end between the instruments, and to have separate IF receivers that take data at separate times. Alternatively, the radar and radiometer could share the antenna through the use of a diplexer, but have completely independent receivers. This novel method shares the radar's RF electronics and digital receiver with the radiometer, while allowing for simultaneous operation of the radar and radiometer. Radars and radiometers, while often having near-identical RF receivers, generally have substantially different IF and baseband receivers. Operation of the two instruments simultaneously is difficult, since airborne radars will pulse at a rate of hundreds of microseconds. Radiometer integration time is typically 10s or 100s of milliseconds. The bandwidth of radar may be 1 to 25 MHz, while a radiometer will have an RF bandwidth of up to a GHz. As such, the conventional method of integrating radar and radiometer hardware is to share the highfrequency RF receiver, but to have separate IF subsystems and digitizers. To avoid corruption of the radiometer data, the radar is turned off during the radiometer dwell time. This method utilizes a modern radar digital receiver to allow simultaneous operation of a radiometer and radar with a shared RF front end and digital receiver. The radiometer signal is coupled out after the first down-conversion stage. From there, the radar transmit frequencies are heavily filtered, and the bands outside the transmit filter are amplified and passed to a detector diode. This diode produces a DC output proportional to the input power. For a conventional radiometer, this level would be digitized. By taking this DC output and mixing it with a system oscillator at 10 MHz, the signal can instead be digitized by a second channel on the radar digital receiver (which typically do not accept DC inputs), and can be down-converted to a DC level again digitally. This unintuitive step allows the digital receiver to sample both the radiometer and radar data at a rapid, synchronized data rate (greater than 1 MHz bandwidth). Once both signals are sampled by the same digital receiver, high-speed quality control can be performed on the radiometer data to allow it to take data simultaneously with the radar. The radiometer data can be blanked during radar transmit, or when the radar return is of a power level high enough to corrupt the radiometer data. Additionally, the receiver protection switches in the RF front end can double as radiometer calibration sources, the short (four-microsecond level) switching periods integrated over many seconds to estimate the radiometer offset. The major benefit of this innovation is that there is minimal impact on the radar performance due to the integration of the radiometer, and the radiometer performance is similarly minimally affected by the radar. As the radar and radiometer are able to operate simultaneously, there is no extended period of integration time loss for the radiometer (maximizing sensitivity), and the radar is able to maintain its full number of pulses (increasing sensitivity and decreasing measurement uncertainty).

McLinden, Matthew↗

Temperature Control with Two Parallel Small Loop Heat Pipes for GLM Program

The concept of temperature control of an electronic component using a single Loop Heat Pipe (LHP) is well established for Aerospace applications. Using two LHPs is often desirable for redundancy/reliability reasons or for increasing the overall heat source-sink thermal conductance. This effort elaborates on temperature controlling operation of a thermal system that includes two small ammonia LHPs thermally coupled together at the evaporator end as well as at the condenser end and operating "in parallel". A transient model of the LHP system was developed on the Thermal Desktop (TradeMark) platform to understand some fundamental details of such parallel operation of the two LHPs. Extensive thermal-vacuum testing was conducted with two thermally coupled LHPs operating simultaneously as well as with only one LHP operating at a time. This paper outlines the temperature control procedures for two LHPs operating simultaneously with widely varying sink temperatures. The test data obtained during the thermal-vacuum testing, with both LHPs running simultaneously in comparison with only one LHP operating at a time, are presented with detailed explanations.

0000↗

Two dimensional digital computer

The development of a two dimensional data processing system is reported that extracts data from optical images by performing multiple logical operations simultaneously. A two dimensional logical circuits is described that contains a liquid crystal negation element and an OR-ing element. The negation element performs 20,000 negations simultaneously, and the OR does 20,000 OR operations simultaneously.

Schaefer, D. H.↗

Visible-telecom tunable dual-band optical isolator based on dynamic modulation in thin-film lithium niobate

Optical isolators are an essential component of photonic systems. Current integrated optical isolators have limited bandwidths due to stringent phase-matching conditions, resonant structures, or material absorption. Here, we demonstrate a wideband integrated optical isolator in thin-film lithium niobate photonics. We use dynamic standing-wave modulation in a tandem configuration to break Lorentz reciprocity and achieve isolation. We measure an isolation ratio of 15 dB and insertion loss below 0.5 dB for a continuous wave laser input at 1550 nm. In addition, we experimentally show that this isolator can simultaneously operate at visible and telecom wavelengths with comparable performance. Isolation bandwidths up to ∼100 nm can be achieved simultaneously at both visible and telecom wavelengths, limited only by the modulation bandwidth. Our device’s dual-band isolation, high flexibility, and real-time tunability can enable novel non-reciprocal functionality on integrated photonic platforms.

Shah, Manav↗

M3D-C1 simulations of the plasma response to RMPs in NSTX-U single-null and snowflake divertor configurations

Non-axisymmetric control coils and the so-called snowflake divertor configuration are two potential solutions proposed to solve two separate outstanding issues on the path towards self-sustained burning plasma operations, namely the transient energy bursts caused by edge localized modes and the steady state heat exhaust problem. In a reactor, these two proposed solutions would have to operate simultaneously and it is, therefore, important to investigate their compatibility and to identify possible conflicts that could prevent them from operating simultaneously. In this work, single- and two-fluid resistive magnetohydrodynamic calculations are used to investigate the effect of externally applied magnetic perturbations on the snowflake divertor configuration. The calculations are based on simulated NSTX-U plasmas and the results show that additional and longer magnetic lobes are created in the null-point region of the snowflake configuration, compared to those in the conventional single-null. The intersection of these longer and additional lobes with the divertor plates are expected to cause more striations in the particle and heat flux target profiles. In addition, the results indicate that the size of the magnetic lobes, in both single-null and snowflake configurations, are more sensitive to resonant magnetic perturbations than to non-resonant magnetic perturbations. The results also suggest that lower values of current in non-axisymmetric control coils would be required to suppress edge localized modes in plasmas with the snowflake configuration.

Snowflake divertor Plasma response Two fluid MHD N↗

The AVIRIS Low Altitude Option-An Approach to Increase Geometric Resolution and Improve Operational Flexibility Simultaneously

From 1987 through 1997 the Airborne Visible-InfraRed Imaging Spectrometer has matured into a remote sensing instrument capable of producing prodigious amounts of high quality data. Using the NASA/Ames ER-2 high altitude aircraft platform, flight operations have become very reliable as well. Being exclusively dependent on the ER-2, however, has limitations: the ER-2 has a narrow cruise envelope which fixes the AVIRIS ground pixel at 20 meters; it requires a significant support infrastructure; and it has a very limited number of bases it can operate from. In the coming years, the ER-2 will also become less available for AVIRIS flights as NASA Earth Observing System satellite underflights increase. Adapting AVIRIS to lower altitude, less specialized aircraft will create a much broader envelope for data acquisition, i.e., higher ground geometric resolution while maintaining nearly the ideal spatial sampling. This approach will also greatly enhance flexibility while decreasing the overall cost of flight operations and field support. Successful adaptation is expected to culminate with a one-month period of demonstration flights.

Sarture, Charles M.↗

Redundant RF system for space application

An S-band radio frequency subsystem is described including two transmitters, two receivers and two antennas. The subsystem is capable of connecting either transmitter or receiver to either antenna while permitting simultaneous operation of a transmitter and a receiver. Circulator switches provide selection of a specific transmitter and receiver for connection to either a high gain or low gain antenna. Transmitter output filters, receiver input filters, and diplexers are combined to prevent radiation or coupling or unwanted transmitter and receiver signals and to provide isolation, permitting simultaneous operation of the transmitter and receiver. The filter elements are designed of constant diameter coaxial elements to meet demanding rejection, loss, power-handling and environmental characteristics.

Rook, C. W.↗

The Atacama Cosmology Telescope: The Polarization-Sensitive ACTPol Instrument

The Atacama Cosmology Telescope (ACT) makes high angular resolution measurements of anisotropies in the Cosmic Microwave Background (CMB) at millimeter wavelengths. We describe ACTPol, an upgraded receiver for ACT, which uses feedhorn-coupled, polarization-sensitive detector arrays, a 3° field of view, 100 mK cryogenics with continuous cooling, and meta material antireflection coatings. ACTPol comprises three arrays with separate cryogenic optics: two arrays at a central frequency of 148 GHz and one array operating simultaneously at both 97 GHz and 148 GHz. The combined instrument sensitivity, angular resolution, and sky coverage are optimized for measuring angular power spectra, clusters via the thermal Sunyaev–Zel'dovich (SZ) and kinetic SZ signals, and CMB lensing due to large-scale structure. The receiver was commissioned with its first 148 GHz array in 2013, observed with both 148 GHz arrays in 2014, and has recently completed its first full season of operations with the full suite of three arrays. This paper provides an overview of the design and initial performance of the receiver and related systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Carbon Dioxide Utilization for Plasma Nanosynthesis of Carbon

This DOE Phase I SBIR project has developed a glow discharge-based plasma process to convert carbon dioxide to sold carbon and water. By adding natural gas, the additional enthalpy can be used to reform the output carbon dioxide to value added carbon and EPA-compliance-grade water, thus creating a process that has no gaseous products at all, such as: CO 2 + CH 4 → 2C + 2H 2 O, which is simply the exothermic reverse of the syngas reaction. During the Phase I work, several milestones were accomplished successfully. a. First, a synthesis reactor was designed, assembled, and successfully operated using the combined simultaneous operation of glow discharge and microwaves. DC discharge and microwaves can also be operated individually, allowing multiple configurations to be used This is one of the first reactors of its kind, and perhaps the first ever. b. Second, the research team successfully produced carbon nanomaterials using carbon dioxide as the source of carbon via CO 2 + 2H 2 → C + 2H 2 O. This is certainly one of the first processes to use plasma to convert carbon dioxide to nanocarbon, and perhaps the first ever demonstration. c. Third, it was also shown that carbon monoxide and carbon dioxide can be used with methane to reduce the synthesis temperature of ASI graphene decorated carbon nanotubes (GDCNT). Hitherto GDCNT were only fabricated above 1200 °C. GDCNT was synthesized at 780 °C. CO 2 + C → 2CO; 2 CO + CH 4 → 3 C + 2H 2 O, and also, CH 4 + CO 2 → 2 C + 2H 2 O. d. Fourth, closed cycle synthesis of nanomaterial was demonstrated with over 80% conversion of carbon dioxide to carbon and water was achieved, on the basis of pressure drop during glow discharge. e. Fifth, plasma operation was achieved via glow discharge and microwaves at 500 Torr, demonstrating a path forward to atmospheric pressure operation f. Sixth, using carbon monoxide and carbon dioxide in an electrothermal furnace, we produced 350 grams per hour of high-quality nanotubes in a single furnace, compared to 200 grams per hour for the commercial process. Controlling the enthalpy prevents self-extinguishing hot gas pyrolysis. Thus, carbon dioxide enhances the properties and reduces the production cost. This is a near term advance that can go into trial production in the near term. g. Seventh, economic analysis suggests an economic plan forward, producing carbon nanotubes for less than $50 per pound. The use of hydrogen and carbon dioxide as the feedstocks is acceptable from a cost basis, and in fact hydrogen is less expensive than carbon monoxide. Niche applications are available in the near term, though quantities relevant to sequestration remain a far-term goal. h. Eighth, though it was not the research team’s intention to create a new process for producing carbon monoxide, it was realized that almost by accident we demonstrated plasma reforming of carbon dioxide via a plasma version of the reverse Boudouard reaction. Accordingly, we have contacted a major gas manufacturer (Matheson Gas) to determine whether there is interest in creating an industrial version of the process. i. Ninth, a long-range strategy is identified in which a progressively more carbon-conscious world will seek to create solid carbon as a means of sequestering carbon dioxide, impeding its return to the atmosphere. In the long term the price must drop by orders of magnitude with larger production, and assuming success, solid carbon could be the preferred form for sequestration rather than underground storage. If carbon can be made as cheaply as dirt, or nearly so, then it can serve a useful purpose as structural material for housing, soil amendments in agriculture and fillers to modify low areas.

03 NATURAL GAS↗