SEARCH · Search NASA
Results for “single experiment”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Single line-of-sight dual energy backlighter for mix width experiments
We present a diagnostic technique used to spatially multiplex two x-ray radiographs of an object onto a detector along a single line-of-sight. This technique uses a thin, <2 μm, cosputtered backlighter target to simultaneously produce both Ni and Zn He{sub α} emission. A Ni picket fence filter, 500 μm wide bars and troughs, is then placed in front of the detector to pass only the Ni He{sub α} emission in the bar region and both energies in the trough region thereby spatially multiplexing the two radiographs on a single image. Initial experimental results testing the backlighter spectrum are presented along with simulated images showing the calculated radiographic images though the nickel picket fence filter which are used to measure the mix width in an accelerated nickel foam.
Cross-section Measurement of the Cosmologically Relevant 7 Be(n, α ) 4 He Reaction over a Broad Energy Range in a Single Experiment
Studying interactions of radioactive ions with neutrons is particularly demanding and has been performed only in a few cases. Some of these interactions are crucial in several astrophysical contexts. In the present work, the case of the 7 Be destruction induced by the (n, α ) reaction is investigated at the energies typical of the primordial nucleosynthesis by means of the Trojan Horse Method applied to the 2 H( 7 Be, αα )p quasi-free reaction. The 7 Be(n, α ) 4 He cross-section has been measured in a single experiment from ~2 MeV down to cosmological energies. The corresponding deduced reaction rate has been adopted to evaluate the impact on big bang nucleosynthesis and on the lithium problem.
Single-experiment-detectable nonclassical correlation witness
Recent progress in theories of quantum information has determined nonclassical correlation defined differently from the widely used entanglement as an important property to evaluate computation and communication with mixed quantum states. We introduce an operational method to detect nonclassical correlation of bipartite systems. In this method, we use particular maps analogous to the well-established entanglement witnesses. Thus, the maps are called nonclassical correlation witness maps. Furthermore, it is proved that such a map can be generally decomposed so that a single-run experiment is feasible for implementation in bulk-ensemble systems.
Understanding bubble and void nucleation in dual ion irradiated T91 steel using single parameter experiments
Not provided.
A Single Column Model Ensemble Approach Applied to the TWP-ICE Experiment
Single column models (SCM) are useful testbeds for investigating the parameterisation schemes of numerical weather prediction and climate models. The usefulness of SCM simulations are limited, however, by the accuracy of the best-estimate large-scale data prescribed. One method to address this uncertainty is to perform ensemble simulations of the SCM. This study first derives an ensemble of large-scale data for the Tropical Warm Pool International Cloud Experiment (TWP-ICE) based on an estimate of a possible source of error in the best-estimate product. This data is then used to carry out simulations with 11 SCM and 2 cloud-resolving models (CRM). Best-estimate simulations are also performed. All models show that moisture related variables are close to observations and there are limited differences between the best-estimate and ensemble mean values. The models, however, show different sensitivities to changes in the forcing particularly when weakly forced. The ensemble simulations highlight important differences in the moisture budget between the SCM and CRM. Systematic differences are also apparent in the ensemble mean vertical structure of cloud variables. The ensemble is further used to investigate relations between cloud variables and precipitation identifying large differences between CRM and SCM. This study highlights that additional information can be gained by performing ensemble simulations enhancing the information derived from models using the more traditional single best-estimate simulation.
Direct detection signatures of self-interacting dark matter with a light mediator
Self-interacting dark matter (SIDM) is a simple and well-motivated scenario that could explain long-standing puzzles in structure formation on small scales. If the required self-interaction arises through a light mediator (with mass ∼10 MeV) in the dark sector, this new particle must be unstable to avoid overclosing the universe. The decay of the light mediator could happen due to a weak coupling of the hidden and visible sectors, providing new signatures for direct detection experiments. The SIDM nuclear recoil spectrum is more peaked towards low energies compared to the usual case of contact interactions, because the mediator mass is comparable to the momentum transfer of nuclear recoils. We show that the SIDM signal could be distinguished from that of DM particles with contact interactions by considering the time-average energy spectrum in experiments employing different target materials, or the average and modulated spectra in a single experiment. Using current limits from LUX and SuperCDMS, we also derive strong bounds on the mixing parameter between hidden and visible sector.
A high-energy-density, high-Mach number single jet experiment
A high-energy-density, x-ray-driven, high-Mach number (M{>=} 17) single jet experiment shows constant propagation speeds of the jet and its bowshock into the late time regime. The jet assumes a characteristic mushroom shape with a stalk and a head. The width of the head and the bowshock also grow linearly in time. The width of the stalk decreases exponentially toward an asymptotic value. In late time images, the stalk kinks and develops a filamentary nature, which is similar to experiments with applied magnetic fields. Numerical simulations match the experiment reasonably well, but ''exterior'' details of the laser target must be included to obtain a match at late times.
Adaptive Planning in Intensity-Modulated Radiation Therapy for Head and Neck Cancers: Single-Institution Experience and Clinical Implications
Purpose: Anatomic changes and positional variability during intensity-modulated radiation therapy (IMRT) for head and neck cancer can lead to clinically significant dosimetric changes. We report our single-institution experience using an adaptive protocol and correlate these changes with anatomic and positional changes during treatment. Methods and Materials: Twenty-three sequential head and neck IMRT patients underwent serial computed tomography (CT) scans during their radiation course. After undergoing the planning CT scan, patients underwent planned rescans at 11, 22, and 33 fractions; a total of 89 scans with 129 unique CT plan combinations were thus analyzed. Positional variability and anatomic changes during treatment were correlated with changes in dosimetric parameters to target and avoidance structures between planning CT and subsequent scans. Results: A total of 15/23 patients (65%) benefited from adaptive planning, either due to inadequate dose to gross disease or to increased dose to organs at risk. Significant differences in primary and nodal targets (planning target volume, gross tumor volume, and clinical tumor volume), parotid, and spinal cord dosimetric parameters were noted throughout the treatment. Correlations were established between these dosimetric changes and weight loss, fraction number, multiple skin separations, and change in position of the skull, mandible, and cervical spine. Conclusions: Variations in patient positioning and anatomy changes during IMRT for head and neck cancer can affect dosimetric parameters and have wide-ranging clinical implications. The interplay between random positional variability and gradual anatomic changes requires careful clinical monitoring and frequent use of CT- based image-guided radiation therapy, which should determine variations necessitating new plans.
Single-Centre Experience with Percutaneous Cryoablation of Breast Cancer in 23 Consecutive Non-surgical Patients
AimTo present our single-centre prospective experience on the use of cryoablation (CA) applied to treat primary breast cancer (BC) in a cohort of patients unsuitable for surgical treatment.Materials and MethodsTwenty-three consecutive post-menopausal female patients (median age 85 years; range 56–96) underwent percutaneous CA of unifocal, biopsy-proven BC, under ultrasound/computed tomography (US/CT) guidance. Clinical and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) follow-ups were systematically scheduled at 3, 12, 18 and 24 months. Local tumour control was assessed by comparing baseline and follow-up DCE-MRI.ResultsTwenty-three BC (median size 14 mm) were treated under local anaesthesia (78.3 %) or local anaesthesia and conscious sedation (21.7 %). Median number of cryo-probes applied per session was 2.0. A “dual-freezing” protocol was applied for the first ten patients and a more aggressive “triple-freezing” protocol for the remaining 13. Median follow-up was 14.6 months. Five patients recurred during follow-up and two were successfully re-treated with CA. Five patients presented immediate CA-related complications: four hematomas evolved uneventfully at 3-month follow-up and one skin burn resulted in skin inflammation and skin retraction at 3 and 12 months, respectively.ConclusionsPercutaneous CA is safe and well tolerated for non-resected elderly BC patients. Procedures can be proposed under local anaesthesia only. Given the insulation properties of the breast gland, aggressive CA protocols are required. Prospective studies are needed to better understand the potential role of CA in the local treatment of early BC.
Linewidth oscillations in a nanometer-size double-slit interference experiment with single electrons
In this article we provide experimental evidence of an interference phenomenon that, to the best of our knowledge, has so far not been observed with either matter or light. In a nanometer-sized version of Feynman's famous two-slit 'thought' experiment with single electrons, we managed to observe that the width of a quasi-monochromatic line oscillates with the detection angle. Furthermore, we find that it occurs in counterphase with the line intensity. We discuss the underlying mechanism that produces this unexpected result.
Single-Center Experience and 1-Year Follow-up Results of 'Sandwich Technique' in the Management of Common Iliac Artery Aneurysms During EVAR
Purpose: Abdominal aortic aneurysm (AAA) accompanied by common iliac artery (CIA) aneurysms requires a more demanding procedure owing to the difficulties in obtaining an adequate distal landing zone for the stent-graft limb(s), a potential site of endoleak. The 'sandwich technique' is a procedure to increase EVAR feasibility in the setting of adverse or challenging CIA anatomy. Its main advantages include no restrictions in terms of CIA diameter or length or internal iliac artery (IIA) diameter, no need to wait for a specific stent-graft. Our purpose is to describe our single-center experience and one year follow-up results of this new procedure. Materials and Methods: From April 2009 to June 2010, the sandwich technique was performed in our institution in 7 patients treated for AAA and unilateral CIA aneurysms (n. 5) or bilateral CIA aneurysms (n. 2). Inclusion criteria were the presence of unilateral or bilateral CIA aneurysm (independently from its diameter), IIA artery measuring up to 9 mm in its maximum diameter, not dilatation of IIA and EIA. Results: The mean follow-up length was 15 months (range: 14-20 months). All stent-implanted iliac branches remained patent on 1 year follow-up and IIA flow was preserved. None of the patients had symptoms of pelvic ischemia. CT scan follow-up showed aneurysm shrinkage in five patients, without any sign of endoleaks in all cases. Conclusions: In selected cases, the 'sandwich technique' showed good outcomes confirming to be a safe and easy to perform way to overcome anatomical constraints and expanding the limits of EVAR.
Time-resolved multiple probe spectroscopy
Time-resolved multiple probe spectroscopy combines optical, electronic, and data acquisition capabilities to enable measurement of picosecond to millisecond time-resolved spectra within a single experiment, using a single activation pulse. This technology enables a wide range of dynamic processes to be studied on a single laser and sample system. The technique includes a 1 kHz pump, 10 kHz probe flash photolysis-like mode of acquisition (pump-probe-probe-probe, etc.), increasing the amount of information from each experiment. We demonstrate the capability of the instrument by measuring the photolysis of tungsten hexacarbonyl (W(CO){sub 6}) monitored by IR absorption spectroscopy, following picosecond vibrational cooling of product formation through to slower bimolecular diffusion reactions on the microsecond time scale.
Single Fraction Versus Fractionated Linac-Based Stereotactic Radiotherapy for Vestibular Schwannoma: A Single-Institution Experience
Purpose: To evaluate and compare outcomes for patients with vestibular schwannoma (VS) treated in a single institution with linac-based stereotactic radiosurgery (SRS) or by fractionated stereotactic radiotherapy (SRT). Methods and Materials: One hundred and nineteen patients (SRS = 78, SRT = 41) were treated. For both SRS and SRT, beam shaping is performed by a mini-multileaf collimator. For SRS, a median single dose of 12.5 Gy (range, 11-14 Gy), prescribed to the 80% isodose line encompassing the target, was applied. Of the 42 SRT treatments, 32 treatments consisted of 10 fractions of 3-4 Gy, and 10 patients received 25 sessions of 2 Gy, prescribed to the 100% with the 95% isodose line encompassing the planning target volume. Mean largest tumor diameter was 16.6 mm in the SRS and 24.6 mm in the SRT group. Local tumor control, cranial nerve toxicity, and preservation of useful hearing were recorded. Any new treatment-induced cranial nerve neuropathy was scored as a complication. Results: Median follow-up was 62 months (range, 6-136 months), 5 patients progressed, resulting in an overall 5-year local tumor control of 95%. The overall 5-year facial nerve preservation probability was 88% and facial nerve neuropathy was statistically significantly higher after SRS, after prior surgery, for larger tumors, and in Koos Grade {>=}3. The overall 5-year trigeminal nerve preservation probability was 96%, not significantly influenced by any of the risk factors. The overall 4-year probability of preservation of useful hearing (Gardner-Robertson score 1 or 2) was 68%, not significantly different between SRS or SRT (59% vs. 82%, p = 0.089, log rank). Conclusion: Linac-based RT results in good local control and acceptable clinical outcome in small to medium-sized vestibular schwannomas (VSs). Radiosurgery for large VSs (Koos Grade {>=}3) remains a challenge because of increased facial nerve neuropathy.
Long-Term Results of a Phase 1 Dose-Escalation Trial and Subsequent Institutional Experience of Single-Fraction Stereotactic Ablative Radiation Therapy for Liver Metastases
We report long-term outcomes from our phase 1 dose-escalation study to determine the maximum tolerated dose of single-fraction liver SABR pooled with our subsequent single institutional experience with patients treated postprotocol at the highest dose level (40 Gy) established from the phase 1 study.
Device-scale CFD modeling of gas-liquid multiphase flow and amine absorption for CO2 capture
In this paper we aim to develop a validated device-scale CFD model that can predict quantitatively both hydrodynamics and CO2 capture efficiency for an amine-based solvent absorber column with random Pall ring packing. A Eulerian porous-media approach and a two-fluid model were employed, in which the momentum and mass transfer equations were closed by literature-based empirical closure models. We proposed a hierarchical approach for calibrating the parameters in the closure models to make them accurate for the packed column. Specifically, a parameter for momentum transfer in the closure was first calibrated based on data from a single experiment. With this calibrated parameter, a parameter in the closure for mass transfer was next calibrated under a single operating condition. Last, the closure of the wetting area was calibrated for each gas velocity at three different liquid flow rates. For each calibration, cross validations were pursued using the experimental data under operating conditions different from those used for calibrations. This hierarchical approach can be generally applied to develop validated device-scale CFD models for different absorption columns.
Single-nucleon experiments
We discuss the Jefferson Lab low momentum transfer data on moments of the nucleon spin structure functions $g_1$ and $g_2$ and on single charged pion electroproduction off polarized proton and polarized neutron. A wealth of data is now available, while more is being analyzed or expected to be taken in the upcoming years. Given the low momentum transfer selected by the experiments, these data can be compared to calculations from Chiral Perturbation theory, the effective theory of strong force that should describe it at low momentum transfer. The data on various moments and the respective calculations do not consistently agree. In particular, experimental data for higher moments disagree with the calculations.The absence of contribution from the $\Delta$ resonance in the various observables was expected to facilitate the calculations and hence make the theory predictions either more robust or valid over a larger $Q^2$ range. Such expectation is verified only for the Bjorken sum, but not for other observables in which the $\Delta$ is suppressed. Preliminary results on pion electroproduction off polarized nucleons are also presented and compared to phenomenological models for which contributions from different resonances are varied. Chiral Perturbation calculations of these observables, while not yet available, would be valuable and, together with these data, would provide an extensive test of the effective theory.
Combined Environments: Driving multiple loads on Z
Pulsed power drivers such as the Z generator of Sandia National Laboratories typically deliver high current (>20MA) to single experiments. This project is intended to develop and assess ways to simultaneously drive multiple targets on a single pulsed power driver (specifically a neutron and an x-ray producing target driven in a single experiment). The combined x-ray/neutron environment produced will then be used to investigate potential synergistic effects in integrated circuits. A pre-requisite for being able to design and study multiple targets on Z is first adapting simulation tools to be able to model them effectively. This will enable us to assess the tradeoffs between the different ways multiple targets can be combined, and to better understand how existing and future pulsed power machines can be used to generate combined testing environments. This report is limited to documenting the initial development of a parallel load modeling capability that is presently being applied to design experiments to produce combined neutron/x-ray environments on Z.