Search NASA⌕ Search

SEARCH · Search NASA

Results for “single particle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Lead Isotope Fingerprinting of Nanoscale Mineral Particles via Single Particle Inductively Coupled Plasma Mass Spectrometry

Determining lead (Pb) isotopic ratios is of broad interest across chemical disciplines for source tracing and age determinations, but the technique is inherently limited when multiple sources of Pb are present in a single sample. Single particle methods offer a solution to directly resolve multiple distinct isotopic ratios within individual samples. In this study, single particle inductively coupled plasma-mass spectrometry (spICP-MS) was performed using time-of-flight (TOF) and multicollector (MC)-based platforms to measure the Pb isotopic composition of individual nanoscale particles. Distinct Pb isotope ratios were measured in particles from four powdered galena samples of different origins (average single-particle 206Pb/207Pb ratios ranging from 0.91 to 1.28) using both the TOF and the MC-based platforms. Differentiation of galena particles in a mixture (liberated grains and those hosted in a silicate matrix) was possible due to detecting their unique multielemental fingerprints. The differing behavior of the two galena samples during digestion was investigated; undigested galena particles trapped within silicate minerals were detected using spICP-MS, which has implications for Pb recovery in bulk-scale isotopic analysis. The multinuclide detection capability of the ICP-TOF-MS instrument allowed for the simultaneous detection of secondary constituent elements within the nanoparticles and the identification of multiple populations of isotopically distinct Pb-bearing particles in a copper ore sample, whereas the increased sensitivity of the MC instrument enabled quantification of 204Pb, allowing differentiation using multiple isotopic ratios. A single particle isotope ratio analysis module was developed within an open-source spICP-TOF-MS data processing platform, enabling its adoption across chemical disciplines.

Goodman, Aaron J. [University of Montreal, Quebec,↗

Single particle – MC-ICP-MS for isotopic analysis of uranium particles

Single particle – multi-collector – inductively coupled plasma – mass spectrometry (SP-MC-ICP-MS) was employed to measure a suspension of 1 µm U3O8 particles (∼1.3 pg total U/particle) to determine their individual isotopic compositions of 234U/238U, 235U/238U, and 236U/238U. The effects of different detector combinations for 235U and 238U, including secondary electron multipliers (SEM) and Faraday detectors (1011 and 1013 Ω amplifiers), were explored for accuracy and precision optimization on the observed 235U/238U. The minor isotopic ratios (i.e., 234U/238U and 236U/238U) were analyzed such that the 234U and 236U were monitored on SEM detectors and the 238U was monitored on a Faraday (1011 Ω) detector. Various integration times (5, 10, 25, and 50 ms) were investigated in all detector configurations to gain a better understanding of their impact on sensitivity, accuracy, and precision. For 235U/238U ratios of 1 µm U3O8 particles, a dual Faraday detector measurement with 1011 Ω was the optimal choice; measurement of 1021 particles yielded an average 235U/238U ratio of 0.00170 (14), a −1.8% relative difference (% RD) from the reference value. The minor isotopic compositions were determined to be 0.0000070 (14) and 0.0000758 (48) for the 234U/238U and 236U/238U, respectively. These measurements correspond to <8% and <1% RD from their reference value for the 234U/238U and 236U/238U, respectively. SP-MC-ICP-MS was also able to provide insight into measurement sensitivity. In these individual particles, merely 15 and 165 atto-grams (ag) of 234U and 236U were present (calculated). Initial limits of detection for SP-MC-ICP-MS were determined to be ∼1.0 ag (when measured via SEM detectors). This valuable approach is applicable to areas including nuclear forensics, nuclear safeguards, and geochemical analysis, which require high-precision measurements of uranium within micron-sized particles.

Manard, Benjamin [ORNL] (ORCID:0000000207400627)↗

In-Situ Characterization of Cloud Condensation Nuclei, Interstitial, and background Particles using Single Particle Mass Spectrometer, SPLAT II

Aerosol indirect effect remains the most uncertain aspect of climate change modeling because proper test requires knowledge of individual particles sizes and compositions with high spatial and temporal resolution. We present the first deployment of a single particle mass spectrometer (SPLAT II) that is operated in a dual data acquisition mode to measure all the required individual particle properties with sufficient temporal resolution to definitively resolve the aerosol-cloud interaction in this exemplary case. We measured particle number concentrations, asphericity, and individual particle size, composition, and density with better than 60 seconds resolution. SPLAT II measured particle number concentrations between 70 particles cm-3and 300 particles cm-3, an average particle density of 1.4 g cm-3. Found that most particles are composed of oxygenated organics, many of which are mixed with sulfates. Biomass burn particles some with sulfates were prevalent, particularly at higher altitudes, and processed sea-salt was observed over the ocean. Analysis of cloud residuals shows that with time cloud droplets acquire sulfate by the reaction of peroxide with SO2. Based on the particle mass spectra and densities we find that the compositions of cloud condensation nuclei are similar to those of background aerosol but, contain on average ~7% more sulfate, and do not include dust and metallic particles. A comparison between the size distributions of background, activated, and interstitial particles shows that while nearly none of the activated particles is smaller than 115 nm, more than 80% of interstitial particles are smaller than 115 nm. We conclude that for this cloud the most important difference between CCN and background aerosol is particle size although having more sulfate also helps.

54 ENVIRONMENTAL SCIENCES↗

Anisotropic single-particle dissipative particle dynamics model

We have developed a new single-particle dissipative particle dynamics (DPD) model for anisotropic particles with different shapes, e.g., prolate or oblate spheroids. In particular, the conservative and dissipative interactions between anisotropic single DPD particles are formulated using a linear mapping from the isotropic model of spherical particles. The proper mapping operator is constructed between each interacting pair of particles at every time step. Correspondingly, the random forces are properly formulated to satisfy the fluctuation-dissipation theorem (FDT). Notably, the model exactly conserves both linear and angular momentum. We demonstrate the proposed model's accuracy and efficiency by applying it for modeling colloidal ellipsoids. Specifically, we show it efficiently captures the static properties of suspensions of colloidal ellipsoids. The isotropic-nematic transition in an ellipsoidal suspension is reproduced by increasing its volume fraction or the aspect ratio of ellipsoid particles. Moreover, the hydrodynamics and diffusion of a single colloidal ellipsoid (prolate or oblate with moderate aspect ratios) are accurately captured. The calculated drag force on the ellipsoid and its diffusion coefficients (both translational and rotational) agree quantitatively with the theoretical predictions in the Stokes limit.

Computer Science↗

Influence of single particle orbital sets and configuration selection on multideterminant wavefunctions in quantum Monte Carlo

Multideterminant wavefunctions, while having a long history in quantum chemistry, are increasingly being used in highly accurate quantum Monte Carlo calculations. Since the accuracy of QMC is ultimately limited by the quality of the trial wavefunction, multi-Slater determinants wavefunctions offer an attractive alternative to Slater-Jastrow and more sophisticated wavefunction ansatz for several reasons. They can be efficiently calculated, straightforwardly optimized, and systematically improved by increasing the number of included determinants. In spite of their potential, however, the convergence properties of multi-Slater determinant wavefunctions with respect to orbital set choice and excited determinant selection are poorly understood, which hinders the application of these wavefunctions to large systems and solids. In this paper, by performing QMC calculations on the equilibrium and stretched carbon dimer, we find that convergence of the recovered correlation energy with respect to number of determinants can depend quite strongly on basis set and determinant selection methods, especially where there is strong correlation. We demonstrate that properly chosen orbital sets and determinant selection techniques from quantum chemistry methods can dramatically reduce the required number of determinants (and thus the computational cost) to reach a given accuracy, which we argue shows clear need for an automatic QMC-only method for selecting determinants and generating optimal orbital sets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved identification of primary biological aerosol particles using single-particle mass spectrometry

Measurements of primary biological aerosol particles (PBAP), especially at altitudes relevant to cloud formation, are scarce. Single-particle mass spectrometry (SPMS) has been used to probe aerosol chemical composition from ground and aircraft for over 20 years. Here we develop a method for identifying bioaerosols (PBAP and particles containing fragments of PBAP as part of an internal mixture) using SPMS. We show that identification of bioaerosol using SPMS is complicated because phosphorus-bearing mineral dust and phosphorus-rich combustion by-products such as fly ash produce mass spectra with peaks similar to those typically used as markers for bioaerosol. We have developed a methodology to differentiate and identify bioaerosol using machine learning statistical techniques applied to mass spectra of known particle types. This improved method provides far fewer false positives compared to approaches reported in the literature. The new method was then applied to two sets of ambient data collected at Storm Peak Laboratory and a forested site in Central Valley, California to show that 0.04–2 % of particles in the 200–3000 nm aerodynamic diameter range were identified as bioaerosol. In addition, 36–56 % of particles identified as biological also contained spectral features consistent with mineral dust, suggesting internal dust–biological mixtures.

54 ENVIRONMENTAL SCIENCES↗

Quantitative single-particle digital autoradiography with α-particle emitters for targeted radionuclide therapy using the iQID camera

Purpose: Alpha-emitting radionuclides exhibit a potential advantage for cancer treatments because they release large amounts of ionizing energy over a few cell diameters (50–80 μm), causing localized, irreparable double-strand DNA breaks that lead to cell death. Radioimmunotherapy (RIT) approaches using monoclonal antibodies labeled with α emitters may thus inactivate targeted cells with minimal radiation damage to surrounding tissues. Tools are needed to visualize and quantify the radioactivity distribution and absorbed doses to targeted and nontargeted cells for accurate dosimetry of all treatment regimens utilizing α particles, including RIT and others (e.g., Ra-223), especially for organs and tumors with heterogeneous radionuclide distributions. The aim of this study was to evaluate and characterize a novel single-particle digital autoradiography imager, the ionizing-radiation quantum imaging detector (iQID) camera, for use in α-RIT experiments. Methods: The iQID camera is a scintillator-based radiation detection system that images and identifies charged-particle and gamma-ray/x-ray emissions spatially and temporally on an event-by-event basis. It employs CCD-CMOS cameras and high-performance computing hardware for real-time imaging and activity quantification of tissue sections, approaching cellular resolutions. In this work, the authors evaluated its characteristics for α-particle imaging, including measurements of intrinsic detector spatial resolutions and background count rates at various detector configurations and quantification of activity distributions. The technique was assessed for quantitative imaging of astatine-211 ({sup 211}At) activity distributions in cryosections of murine and canine tissue samples. Results: The highest spatial resolution was measured at ∼20 μm full width at half maximum and the α-particle background was measured at a rate as low as (2.6 ± 0.5) × 10{sup −4} cpm/cm{sup 2} (40 mm diameter detector area). Simultaneous imaging of multiple tissue sections was performed using a large-area iQID configuration (ø 11.5 cm). Estimation of the {sup 211}At activity distribution was demonstrated at mBq/μg-levels. Conclusions: Single-particle digital autoradiography of α emitters has advantages over traditional film-based autoradiographic techniques that use phosphor screens, in terms of spatial resolution, sensitivity, and activity quantification capability. The system features and characterization results presented in this study show that the iQID is a promising technology for microdosimetry, because it provides necessary information for interpreting alpha-RIT outcomes and for predicting the therapeutic efficacy of cell-targeted approaches using α emitters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamics of nuclear single-particle structure in covariant theory of particle-vibration coupling: From light to superheavy nuclei

The impact of particle-vibration coupling and polarization effects due to deformation and time-odd mean fields on single-particle spectra is studied systematically in doubly magic nuclei from low-mass {sup 56}Ni up to superheavy ones. Particle-vibration coupling is treated fully self-consistently within the framework of the relativistic particle-vibration coupling model. Polarization effects due to deformation and time-odd mean field induced by odd particle are computed within covariant density functional theory. It has been found that among these contributions the coupling to vibrations makes a major impact on the single-particle structure. The impact of particle-vibration coupling and polarization effects on calculated single-particle spectra, the size of the shell gaps, the spin-orbit splittings and the energy splittings in pseudospin doublets is discussed in detail; these physical observables are compared with experiment. Particle-vibration coupling has to be taken into account when model calculations are compared with experiment since this coupling is responsible for observed fragmentation of experimental levels; experimental spectroscopic factors are reasonably well described in model calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Single‐Particle Tracking for Understanding Polydisperse Nanoparticle Dispersions

Abstract Colloidal dispersions of nanomaterials are often polydisperse in size, significantly complicating their characterization. This is particularly true for materials early in their historical development due to synthetic control, dispersion efficiency, and instability during storage. Because a wide range of system properties and technological applications depend on particle dimensions, it remains an important problem in nanotechnology to identify a method for the routine characterization of polydispersity in nanoparticle samples, especially changes over time. Commonly employed methods such as dynamic light scattering or analytical ultracentrifugation (AUC) accurately estimate only the first moment of the distribution or are not routine. In this work, the use of single‐particle tracking (SPT) to probe size distributions of common nanoparticle dispersions, including polystyrene nanoparticles, single‐walled carbon nanotubes, graphene oxide, chitosan‐tripolyphosphate, acrylate, hexagonal boron nitride, and poly(lactic‐ co ‐glycolic acid), is proposed and explored. The analysis of particle tracks is conducted using a newly developed Bayesian algorithm that is called Maximum A posteriori Nanoparticle Tracking Analysis. By combining SPT and AUC techniques, it is shown that it is possible to independently estimate the mean aspect ratio of anisotropic particles, an important characterization property. It is concluded that SPT provides a facile, rapid analytical method for routine nanomaterials characterization.

Gong, Xun↗

Probing the Single-Particle Character of Rotational States in F 19 Using a Short-Lived Isomeric Beam

A beam containing a substantial component of both the J π = 5 + , T 1 / 2 = 162 ns isomeric state of F 18 and its 1 + , 109.77-min ground state is utilized to study members of the ground-state rotational band in F 19 through the neutron transfer reaction ( d , p ) in inverse kinematics. The resulting spectroscopic strengths confirm the single-particle nature of the 13 / 2 + band-terminating state. The agreement between shell-model calculations using an interaction constructed within the s d shell, and our experimental results reinforces the idea of a single-particle–collective duality in the descriptions of the structure of atomic nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantifying Photocurrent Loss of a Single Particle–Particle Interface in Nanostructured Photoelectrodes

Particle–particle interfaces are ubiquitous in nanostructured photoelectrodes and photovoltaics, which are important devices for solar energy conversion. Furthermore, these interfaces are expected to cause performance losses in these devices, but how much loss they would incur is poorly defined. Here we use a subparticle photoelectrochemical current measurement, in combination with specific photoelectrode configurations, to quantify the current losses from single particle–particle interfaces formed between individual TiO 2 nanorods operating as photoanodes in aqueous electrolytes. We find that a single interface leads to ~20% photocurrent loss (i.e., ~80% retention of the original current). Such quantitative, first-of-its-kind, information provides a metric for guiding the optimization and design of nanostructured photoelectrodes and photovoltaics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single-particle and collective structures in {sup 55}Cr and {sup 55}V

Excited states in {sup 55}V and {sup 55}Cr have been populated via pn and 2n evaporation channels, respectively, following the fusion of a {sup 48}Ca beam at 172 MeV with a {sup 9}Be target. Level schemes have been deduced for the two nuclides to excitation energies of 7467 ({sup 55}V) and 12226 keV ({sup 55}Cr), with spins of 27/2{sup +} and 33/2{sup +}, respectively. Negative-parity states are compared with shell-model calculations using three different effective interactions in the full fp model space. Negative-parity levels of {sup 55}Cr are explained in terms of single-particle fp-shell configurations outside N=28 and N=32 cores. Positive-parity states in both isotopes show evidence for the involvement of neutron g{sub 9/2} configurations. In the case of {sup 55}Cr, a quasirotational structure based on the 1/2{sup +}[440] Nilsson orbital is observed up to the terminating state. In {sup 55}V, positive-parity states do not exhibit well-developed collective features, and the observation of octupole decays is an indication of their importance in transitions from neutron g{sub 9/2} configurations to the fp shell. Experimental results are compared with the predictions of a traditional shell model, the projected shell model, and total-Routhian-surface calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗