Search NASA⌕ Search

SEARCH · Search NASA

Results for “single phase air conditioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The Effect of Power Electronic Loads on Western Interconnection Stability

The prevalence of power electronics in the bulk power system is increasing rapidly in both the generation and consumption of electricity. This work focuses on the effect of changing load composition - specifically the transition from single phase air conditioner motors to power electronics backed air conditioners - on power system stability. Various transmission and generation contingency events for the Western Interconnection were simulated using Positive Sequence Load Flow software and planning models from the Western Electricity Coordinating Council. In general, an increased proportion of power electronic load leads to more instability. For some specific faults resulting in fault-induced delayed voltage recovery, transitioning to higher proportions of power electronic loads helps expedite system recovery. These results demonstrate that load composition should be examined in conjunction with generation composition when evaluating system stability.

FIDVR↗

Recharge Demand Mitigation for Latent Heat Thermal Energy Storage at Off-peak Hours

The utilization of integrated heat pump thermal energy storage (HP-TES) systems for space conditioning applications can reduce electrical power demand and achieve utility savings resulting from peak shaving and load shifting. However, issues arise when the energy required to recharge the TES exceeds the shifted energy demand, especially in extreme climates where high-temperature lifts between the outdoor air conditions and phase-change materials (PCMs) during recharging may occur. In this work, a single room-temperature (22°C) PCM-TES is integrated into a single-speed heat pump system using a secondary hydronic loop where the TES is recharged using the outdoor unit during off-peak hours. Three recharge strategies were investigated as potential pathways to reduce recharging power demand: (i) considering different heat source/sink temperatures, (ii) using a variable-speed compressor, and (iii) using a variable-speed pump. Simulations were conducted using Modelica for HP-TES recharging at different heat source/sink temperatures from -30 – 20℃ in heating mode and 0 – 30℃ in cooling mode. Results show that the most effective recharge demand reduction strategy is an HP-TES system using a single-speed compressor with a variable-speed pump for the hydronic loop run at preferable heat source/sink temperatures when the temperature lifts were reduced. Utilizing a variable-speed compressor for the HP-TES system reduced recharge time in extreme cases at the cost of additional compressor power input. The findings motivate potential control strategies that minimize recharge energy and maximize peak energy savings, hence reducing overall operating costs and annual energy consumption for HP-TES systems for space conditioning applications.

25 ENERGY STORAGE↗

Experimentation on Finned-Tube Microchannel Heat Exchanger Incorporating Phase Change Material and R-410A

Integrating latent heat thermal energy storage, particularly phase change materials (PCM), in building heating, ventilation, air conditioning, and refrigeration (HVAC&R) systems, offers substantial benefits for peak load shifting and energy efficiency. While numerous studies explore PCM-embedded heat exchangers (PCM-HX) using single-phase heat transfer fluids, there needs to be more investigation regarding PCM-HX utilizing two-phase refrigerant flow. This gap is even more pronounced for microchannel heat exchanger (MCHX) configurations. In this study, an MCHX-based PCM-HX was built and tested to analyze and evaluate the performance of a PCM-HX operating with a two-phase refrigerant as the working fluid. A commercially available MCHX condenser unit was embedded with 2.6 kg of RT35 PCM and tested using R-410A as the working fluid, using an in-house test loop to control the refrigerant inlet conditions precisely. Thin and minimally invasive T-type thermocouples traced the temperature evolution along MCHX channels and tube banks. Additional larger T-type thermocouple probes at the refrigerant inlet and outlet measured the average power of the PCM-HX during condensing tests, ranging from 0.7 kW to 1.6 kW based on mass flow rates varying from 3.5 g/s to 8 g/s. This experimental study on MCHX-based PCM-HX with a two-phase refrigerant has the potential to offer practical design guidelines for the direct integration of PCM-TES in HVAC&R systems without the use of a secondary loop, while caution is advised to avoid a substantial increase in the refrigerant charge amount.

42 ENGINEERING↗

Atomically dispersed palladium catalyses Suzuki–Miyaura reactions under phosphine-free conditions

Single-atom catalysts have emerged as a new frontier in catalysis science. However, their applications are still limited to small molecule activations in the gas phase, the classic organic transformations catalyzed by single-atom catalysts are still rare. Here, we report the use of a single-atom Pd catalyst for the classic Suzuki–Miyaura carbon–carbon coupling reaction under phosphine-free and open-air conditions at room temperature. The single-atom Pd catalyst is prepared through anchoring Pd on bimetal oxides (Pd-ZnO-ZrO 2 ). The significant synergetic effect of ZnO and ZrO 2 is observed. The catalyst exhibits high activity and tolerance of a wide scope of substrates. Characterization demonstrates that Pd single atoms are coordinated with two oxygen atoms in Pd-ZnO-ZrO 2 catalyst. The catalyst can be fabricated on a multi-gram scale using a simple in situ co-precipitation method, which endows this catalytic system with great potential in practical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal-hydraulic Performance of Emerging Low GWP Refrigerant Mixture under Flow Boiling in Brazed Plate Heat Exchangers

The hydrofluorocarbon (HFC) refrigerants used in the current refrigeration systems are facing a phase-down due to their higher greenhouse effect resulting in global warming, and thus HVAC&R industry has undergone a transition to low Global Warming Potential (GWP) refrigerants. Refrigerant mixtures are attractive alternatives since their composition can be tailored to comply with environmental regulations while preserving favorable thermophysical properties. However, the new low-GWP zeotropic mixture refrigerants have two or more components with different saturation temperatures at the same pressure level, known as temperature glide, which can cause the degradation of the overall heat transfer performance. The brazed plate heat exchangers (BPHX) provide excellent heat transfer performance due to a compact design and are used in several air-conditioning and refrigeration applications. In this study, flow boiling heat transfer and the associated pressure drop of the refrigerant mixture in a vertical BPHX were experimentally investigated. The single-phase water-to-water experiments were conducted in the tested heat exchanger with a counter-flow configuration. The flow boiling experiments charged with R-134a and R-454C were then performed in a pumped refrigerant loop to evaluate its thermal-hydraulic performance. Furthermore, parametric studies of various heat fluxes, mass fluxes, vapor qualities, and saturation temperatures were also conducted.

Yang, Cheng-Min↗

Effect of environment on fracture toughness of 96 wt pct alumina

An effort is made to deepen understanding of environmental effects on the fracture toughness of an alumina composition that contains a residual glassy phase, by ascertaining the fracture toughness under atmospheric conditions in such varied environments as air distilled water, silicone oil, and liquid nitrogen. Fracture toughness was determined via the single-edge-precracked beam technique. Weibull strength parameters are compared for polished specimens tested both in air and silicone environments.

Choi, Sung R.↗

Bubble Generation in a Flowing Liquid Medium and Resulting Two-Phase Flow in Microgravity

The present investigation reports a study of bubble generation under reduced gravity conditions, using both a co-flow and a cross-flow configuration. This study may be used in the conceptual design of a space-based thermal management system. Ensuing two-phase flow void fraction can be accurately monitored using a single nozzle gas injection system within a continuous liquid flow conduit, as utilized in the present investigation. Accurate monitoring of void fraction leads to precise control of heat and mass transfer coefficients related to a thermal management system; hence providing an efficient and highly effective means of removing heat aboard spacecraft or space stations. Our experiments are performed in parabolic flight aboard the modified DC-9 Reduced Gravity Research Aircraft at NASA Lewis Research Center, using an air-water system. For the purpose of bubble dispersion in a flowing liquid, we use both a co-flow and a cross-flow configuration. In the co-flow geometry, air is introduced through a nozzle in the same direction with the liquid flow. On the other hand, in the cross-flow configuration, air is injected perpendicular to the direction of water flow, via a nozzle protruding inside the two-phase flow conduit. Three different flow conduit (pipe) diameters are used, namely, 1.27 cm, 1.9 cm and 2.54 cm. Two different ratios of nozzle to pipe diameter (D(sub N))sup * are considered, namely (D(sub N))sup * = 0.1 and 0.2, while superficial liquid velocities are varied from 8 to 70 cm/s depending on flow conduit diameter. It is experimentally observed that by holding all other flow conditions and geometry constant, generated bubbles decrease in size with increase in superficial liquid velocity. Detached bubble diameter is shown to increase with air injection nozzle diameter. Likewise, generated bubbles grow in size with increasing pipe diameter. Along the same lines, it is shown that bubble frequency of formation increases and hence the time to detachment of a forming bubble decreases, as the superficial liquid velocity is in-creased. Furthermore, it is shown that the void fraction of the resulting two-phase flow increases with volumetric gas flow rate Q(sub d), pipe diameter and gas injection nozzle diameter, while they decrease with surrounding liquid flow. The important role played by flowing liquid in detaching bubbles in a reduced gravity environment is thus emphasized. We observe that the void fraction can be accurately controlled by using single nozzle gas injection, rather than by employing multiple port injection, since the later system gives rise to unpredictable coalescence of adjacent bubbles. It is of interest to note that empirical bubble size and corresponding void fraction are somewhat smaller for the co-flow geometry than the cross-flow configuration at similar flow conditions with similar pipe and nozzle diameters. In order to supplement the empirical data, a theoretical model is employed to study single bubble generation in the dynamic (Q(sub d) = 1 - 1000 cu cm/s) and bubbly flow regime within the framework of the co-flow configuration. This theoretical model is based on an overall force balance acting on the bubble during the two stages of generation, namely the expansion and the detachment stage. Two sets of forces, one aiding and the other inhibiting bubble detachment are identified. Under conditions of reduced gravity, gas momentum flux enhances, while the surface tension force at the air injection nozzle tip inhibits bubble detachment. In parallel, liquid drag and inertia can act as both attaching and detaching forces, depending on the relative velocity of the bubble with respect to the surrounding liquid. Predictions of the theoretical model compare well with our experimental results. However, at higher superficial liquid velocities, as the bubble loses its spherical form, empirical bubble size no longer matches the theoretical predictions. In summary, we have developed a combined experimental and theoretical work, which describes the complex process of bubble generation and resulting two-phase flow in a microgravity environment. Results of the present study can be used in a wide range of space-based applications, such as thermal energy and power generation, propulsion, cryogenic storage and long duration life support systems, necessary for programs such as NASA's Human Exploration for the Development of Space (HEDS).

Pais, S. C.↗

Preliminary Design of Reactor Cavity Cooling System for a Horizontal Compact HTGR

The Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed MIGHTR in 3 years and support its commercialization as a safe and low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. This report documents the preliminary design study of the RCCS for the HC-HTGR. It includes the establishment of the design requirements, a high-level design study by initial scoping calculations, and preliminary performance calculations of the HC-HTGR RCCS design. Design requirements for the HC-HTGR RCCS have been established to guide preliminary design activities and scoping performance calculations. Initial scoping calculations including estimation of the water inventory, estimation of HVAC thermal capability, and a parametric study on loop dimensions by standalone RCCS analysis. Based on scoping calculation results, a set of baseline dimensions of the HC-HTGR RCCS was derived. A water panel modeling approach was investigated to explore various potential design options for the water panel under consideration for the HC-HTGR RCCS using RELAP5-3D. A test case study was performed to assess the prediction capability of two modeling approaches. The results were compared with CFD simulations conducted in constant RPV temperature and heat flux boundary conditions. It confirms the capability of the RELAP5-3D modeling approach to include all important heat transfer mechanisms expected in the HC-HTGR RCCS operation conditions. Then, a reference RELAP5-3D model for the 1/8 th of a compartment of the preliminary design of the HC-HTGR RCCS was developed. A preliminary performance analysis was conducted to evaluate single-phase natural circulation performance with different top tank temperature values and panel conduction performance in various operation conditions. From single-phase natural circulation performance analysis, the system operation mode was investigated in normal operating and limiting design conditions. It showed operation mode in a subcooled state with a proper top tank water cooling system. Parasitic heat loss by both internal air flow and RCCS was estimated, showing it satisfies maintaining below target maximum heat loss of the HC-HTGR RCCS. From the panel conduction performance analysis, two candidate materials for the riser tube such as carbon steel and stainless steel were compared in the thermal performance of HC-HTGR RCCS. From a single water panel test compared with CFD simulation results, it was confirmed that the current capability of the RELAP5-3D modeling approach for the water panel predicts the thermal conduction of two different materials of the water panel. Then, system-level thermal performance analysis was performed for 1/8 th of the compartment of the preliminary HC-HTGR RCCS design. It was first observed that the current preliminary HC-HTGR RCCS design had minimal impact on the overall thermal performance of the water panel by changing pipe material from carbon steel to stainless steel. From Argonne’s effort on the ongoing water-based NSTF testing program, several considerations other than the thermal performance point of view were addressed to be considered in selecting pipe materials.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fuel injector: Air swirl characterization aerothermal modeling, phase 2, volume 1

A well integrated experimental/analytical investigation was conducted to provide benchmark quality relevant to a prefilming type airblast fuel nozzle and its interaction with the combustor dome air swirler. The experimental investigation included a systematic study of both single-phase flows that involved single and twin co-axial jets with and without swirl. A two-component Phase Doppler Particle Analyzer (PDPA) was used to document the interaction of single and co-axial air jets with glass beads that simulate nonevaporating spray and simultaneously avoid the complexities associated with fuel atomization processes and attendant issues about the specification of relevant boundary conditions. The interaction of jets with methanol spray produced by practical airblast nozzle was also documented in the spatial domain of practical interest. Model assessment activities included the use of three turbulence models (k-epsilon, algebraic second moment (ASM), and differential second moment (DSM)) for the carrier phase, deterministic or stochastic Lagrangian treatment of the dispersed phase, and advanced numerical schemes. Although qualitatively good comparison with data was obtained for most of the cases investigated, the model deficiencies in regard to modeled dissipation rate transport equation, single length scale, pressure-strain correlation, and other critical closure issues need to be resolved before one can achieve the degree of accuracy required to analytically design combustion systems.

Nikjooy, M.↗

Fuel Injector: Air swirl characterization aerothermal modeling, phase 2, volume 2

A well integrated experimental/analytical investigation was conducted to provide benchmark quality data relevant to prefilming type airblast fuel nozzle and its interaction with combustor dome air swirler. The experimental investigation included a systematic study of both single-phase flows that involved single and twin co-axial jets with and without swirl. A two-component Phase Doppler Particle Analyzer (PDPA) equipment was used to document the interaction of single and co-axial air jets with glass beads that simulate nonevaporating spray and simultaneously avoid the complexities associated with fuel atomization processes and attendant issues about the specification of relevant boundary conditions. The interaction of jets with methanol spray produced by practical airblast nozzle was also documented in the spatial domain of practical interest. Model assessment activities included the use of three turbulence models (k-epsilon, algebraic second moment (ASM) and differential second moment (DSM)) for the carrier phase, deterministic or stochastic Lagrangian treatment of the dispersed phase, and advanced numerical schemes. Although qualitatively good comparison with data was obtained for most of the cases investigated, the model deficiencies in regard to modeled dissipation rate transport equation, single length scale, pressure-strain correlation, and other critical closure issues need to be resolved before one can achieve the degree of accuracy required to analytically design combustion systems.

Nikjooy, M.↗

Computationally Guided Investigation of the Optical Spectra of Pure β-UO 3

Single-phase β-UO 3 is synthesized by flash heating UO 2 (NO 3 )·6H 2 O in air to 450 °C and annealing for 60 h under the same conditions. For the first time, we report the Raman spectra of pure β-UO 3 . To facilitate the assignment of Raman and infrared vibrational modes, we use density functional theory with density functional perturbation theory. By employing a novel analysis scheme that includes the mode frequencies as well as a quantitative analysis of the mode eigenvectors, we assign the observed spectral features to individual chemical modes. In particular, the density functional theory optimized structure, observed Raman spectrum, and eigenvector analysis suggest the presence of four crystallographically distinct uranyl ions, one more than has previously been suggested.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dual-season thermal energy storage-integrated heat pump system for load shifting: experiments, modeling and nationwide analysis

Here, this paper proposes and validates a dual-season thermal energy storage-integrated heat pump (TES-HP) system that shifts building electric load in both cooling and heating modes using a single phase-change TES. The design uses the TES as a heat sink for the condenser in summer and a heat source for the evaporator in winter, thereby reducing on-peak electric demand while ensuring compatible with existing air-distribution systems. A 14-kW TES-HP prototype with six operating modes and novel refrigerant charge management strategies was experimentally tested under varied conditions. Subsequently, data-driven polynomial performance curves were developed and validated against experiments, then coupled with a phase change material (PCM) model and a calibrated building model within a rule-based controller. Single-day case studies demonstrated effective on-peak demand reduction while maintaining thermal comfort. During cooling, hourly power was lowered by up to 1.5 kW; in heating, average hourly power decreased from over 3.5 kW to 1.8 kW, compared to an HP-only system, achieving 64.5 % load shifting, and the need for resistance heating was eliminated. Seasonal simulations showed typical on-peak electricity savings of 25–35 % in cooling and 40–65 % in heating, with the largest benefits on the hottest and coldest days. Extended response-surface analysis and nationwide mapping quantified load shifting as functions of ambient and TES temperatures, revealing a seasonal trade-off in TES phase-change temperature. These results demonstrate the TES-HP system as a practical and scalable solution for grid-interactive buildings that reduces on-peak demand and electricity use while maintaining thermal comfort and enhancing grid flexibility and reliability.

Grid-interactive buildings↗

Long-Term Infrasound Sensor Calibration and Characterization

Previous testing has shown that infrasound sensors deployed in the field can exhibit notable deviations from their nominal, lab-based calibrations. These variations may be due to changes in environmental conditions, long-term sensor drift, or other unresolved features. In early 2018, we installed two identical infrasound elements with five infrasound sensors at each element (Chaparral M50A, Chaparral M64LN, CEA/Martec MB2005, CEA/Seismowave MB3a, and Hyperion IFS-5113A). These sensors were accepted or under consideration for use in the International Monitoring System network of the Comprehensive Nuclear-Test-Ban Treaty. Each element had all sensors connected to a single digitizer and port to the atmosphere. We also recorded instrument enclosure air temperature and humidity and external air temperature. Using the MB2005 as the reference, we examine the relative sensor response (both magnitude and phase) as a function of time and frequency and compare it with quarterly laboratory calibrations and environmental conditions. Here, we find that the magnitude response for all sensors exhibits some variability in both the lab and field, with the amplitude variations often >5%. The field-based variations are more severe and occur on both long-term (months) and short-term (hours) timescales. Short-term variability correlates with changes in environmental conditions and is considerable (up to 25%) for the Chaparral M50A and noticeable (∼5%) for the French Alternative Energies and Atomic Energy Commission (CEA) MB3a. Long-term magnitude variability for the Chaparral M50A was up to 50% and does not clearly correlate with environmental conditions. The other sensors show some long-term magnitude offsets, but they have relatively stable responses in the conditions we examined. The MB3a also displays some frequency-dependent magnitude variability and shows a minor dependence on temperature. Phase estimates are stable and near zero for all sensors tested. These results strongly suggest sensor response and variability due to environmental conditions should be considered in future infrasound data interpretation and sensor selection and development.

Fee, David↗

High Efficiency Heat Pumps Can Pave the Path for Building Decarbonization in Cold Climates: Preprint

Heat pumps play an instrumental role in buildings decarbonization strategies. Recent advances in heat pump systems employ variable-speed compressor technology and electronically commutated fan motors. Inherently, the heating capacity and efficiency of heat pumps decrease with falling outdoor temperatures. Compared to single-speed heat pumps, variable speed systems can maintain higher heating and cooling efficiencies over a wider range of outdoor temperatures. The goal of this multi-phase project was to determine the energy savings of a high efficiency, variable-speed, air-source, split system heat pump designed for cold climate applications. The first project phase was to evaluate the performance of the heat pump in the laboratory under varying outdoor conditions in heating and cooling modes. The second phase was to translate the laboratory-measured performance into lookup tables for EnergyPlus hourly building simulation engine. Then, two sets of annual building simulations were performed using typical meteorological year weather from the Chicago-O'Hare airport for three different building types (a single-family residence, a strip mall, and a low-rise office building). The first set simulated a standard efficiency heat pump while the second set utilized the phase two performance tables to model a high efficiency heat pump. The high efficiency heat pump produced significant annual heating energy savings in all three buildings. The variable speed compressor and fan control also contributed to cooling energy savings. The simulated annual energy savings ranged from 22% to 35% over their respective baseline. The project's findings helped a Midwest electric utility, Commonwealth Edison (ComEd), design new incentives around high efficiency heat pumps.

cold climate heat pump↗

Glovebox CFD Analysis: Low-Flow, Laminar CFD Analysis of Glovebox Ventilation and Humidity Transport in Ansys Fluent 2025 R1

There are gloveboxes that frequently exceed the 30% relative humidity level required for operations. These exceedances result in alternative operations needing to be utilized. This report documents a computational fluid dynamics (CFD) analysis performed to characterize airflow and humidity transport within a representative glovebox under nominal, low-flow conditions. The analysis focuses on establishing the flow regime, identifying transport-limited regions, and evaluating the implications of laminar flow on humidity removal. A single-phase, laminar flow model with a species transport model was used to represent air and water vapor mixing. Results demonstrate that, at the nominal flow rates, airflow is laminar with weak mixing, which will result in long residence times, tens of minutes long or more, in low-velocity regions. These conclusions suggests that humidity reduction is transport-limited. This analysis provides qualitative insight into airflow structure and humidity transport trends. In addition to characterization of glovebox airflow and humidity transport, results are intended to inform experimental validation and future transient modeling efforts.

42 ENGINEERING↗

Gas and drop behavior in reacting and non-reacting air-blast atomizer sprays

A detailed study of the two-phase flow produced by a gas-turbine air-blast atomizer is performed with the goal of identifying the interaction between the two phases for both nonreacting and reacting conditions. A two-component phase Doppler interferometry is utilized to characterize three flowfields produced by the atomizer: (1) the single-phase flow, (2) the two-phase nonreacting spray, and (3) the two-phase reacting spray. Measurements of the mean and fluctuating axial and azimuthal velocities for each phase are obtained. In addition, the droplet size distribution, volume flux, and concentration are measured. The results reveal the strong influence of the dispersed phase on the gas, and the influence of reaction on both the gas and the droplet field. The presence of the spray significantly alters the inlet condition of the atomizer. With this alteration quantified, it is possible to deduce that the inertia associated with the dispersed phase damps the fluctuating velocities of the gas. Reaction reduces the volume flux of the droplets, broadens the local volume distribution of the droplets in the region of the reaction zone, increases the axial velocities and radial spread of the gas, and increases the anisotropy in the region of the reaction zone.

Mcdonell, Vincent G.↗

FIDVR Capability of Hybrid Grid-Forming PV Power Plants During Feeder Restoration

Grid-forming inverters must optimally transfer power from dc-coupled photovoltaic arrays and batteries into an ac grid. Further, they must be able to restore single-phase induction motors (SPIMs) and withstand fault-induced delayed voltage-recovery (FIDVR) events. These resilience and reliability challenges are addressed here by: (i) engineering a controller to optimally operate dc-coupled hybrid resources; (ii) modeling residential air-conditioning compressors for restoration/FIDVR studies; and (iii) analyzing SPIM thermal-relay performance under limited inverter currents and designing an electronic protection for stalled SPIMs. Furthermore, these contributions are demonstrated via electromagnetic-transient simulations and can be helpful to understand recommendations by the North American Electric Reliability Corporation.

14 SOLAR ENERGY↗

Performance and Operational Characteristics of a Python Turbine-propeller Engine at Simulated Altitude Conditions / Carl L. Meyer and Lavern A. Johnson

The performance and operational characteristics of a Python turbine propeller engine have been investigated over a range of engine operating conditions at simulated altitudes from 5000 to 40,000 feet in the NACA Lewis altitude wind tunnel . For the performance phase of the investigation, a single cowl-inlet ram pressure ratio was maintained and independent control of engine speed and fuel flow was used to obtain a range of power at each engine speed. Engine performance data obtained at a given altitude could not be used to predict performance accurately at other altitudes by use of the standard air pressure and temperature generalizing factors. Specific fuel consumption based on shaft horsepower decreased as the shaft horsepower increased at a given engine speed. At a given altitude condition and turbine -inlet total temperature, there was an optimum engine speed at which maximum shaft horsepower was obtained. At a given engine speed and turbine-inlet total temperature, a greater portion of the total available energy was converted to propulsive power as the altitude increased. Windmilling starts were made at altitudes up to 40,000 feet; the minimum true airspeed required for successful windmilling starts increased as the altitude was raised. In general, the engine control prevented large overshoots or undershoots of engine speed during starts, accelerations, and decelerations.

Engines - Armstrong-Siddely Python Turbo-Propeller↗