Search NASA⌕ Search

SEARCH · Search NASA

Results for “single photon avalanche diodes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Radiation Tests of Single Photon Avalanche Diode for Space Applications

Single photon avalanche diodes (SPADs) have been recently studied as photodetectors for applications in space missions. In this presentation we report the results of radiation hardness test on large area SPAD (actual results refer to SPADs having 500 micron diameter). Dark counts rate as low as few kHz at −10 degC has been obtained for the 500 micron devices, before irradiation. We performed bulk damage and total dose radiation tests with protons and gamma-rays in order to evaluate their radiation hardness properties and their suitability for application in a Low Earth Orbit (LEO) space mission. With this aim SPAD devices have been irradiated using up to 20 krad total dose with gamma-rays and 5 krad with protons. The test performed show that large area SPADs are very sensitive to proton doses as low as 2×10(exp 8) (1 MeV eq) n/cm2 with a significant increase in dark counts rate (DCR) as well as in the manifestation of the "random telegraph signal" effect. Annealing studies at room temperature (RT) and at 80 degC have been carried out, showing a high decrease of DCR after 24-48 h at RT. Lower protons doses in the range 1-10×10(exp 7) (1 MeV eq) n/cm(exp 2) result in a lower increase of DCR suggesting that the large-area SPADs tested in this study are well suitable for application in low-inclination LEO, particularly useful for gamma-ray astrophysics.

radiation hardness↗

Scintillation event imaging with a single photon avalanche diode camera

Position and time measurements of scintillation events encode information about the radiation source. Single photon avalanche diode (SPAD) arrays offer multiple-megapixel spatial resolution and tens of picoseconds temporal resolution for detecting single photons. Current lensless designs for measuring scintillation events use sensors that are lower in spatial resolution. Camera-based designs use sensors that are lower in temporal resolution or readout rate and cannot image individual interactions. Here we propose to image scintillation events in a thick, monolithic scintillator using a high-resolution SPAD camera. We demonstrate that a commercial SPAD camera is able to gather sufficient signal to image individual scintillation events and observe 3D shifts in their spatial distribution. Simulations show that a SPAD camera can localize individual scintillation events in 3D. We report direct imaging of gamma-ray interactions in a scintillator with a SPAD camera. The proposed design may allow to measure complex signatures of individual particles interacting in the scintillator.

47 OTHER INSTRUMENTATION↗

Light-sheet autofluorescence lifetime imaging with a single-photon avalanche diode array

Significance: Fluorescence lifetime imaging microscopy (FLIM) of the metabolic co-enzyme nicotinamide adenine dinucleotide (phosphate) [NAD(P)H] is a popular method to monitor single-cell metabolism within unperturbed, living 3D systems. However, FLIM of NAD(P)H has not been performed in a light-sheet geometry, which is advantageous for rapid imaging of cells within live 3D samples. Aim: We aim to design, validate, and demonstrate a proof-of-concept light-sheet system for NAD(P)H FLIM. Approach: A single-photon avalanche diode camera was integrated into a light sheet microscope to achieve optical sectioning and limit out-of-focus contributions for NAD(P)H FLIM of single cells. Results: An NAD(P)H light-sheet FLIM system was built and validated with fluores cence lifetime standards and with time-course imaging of metabolic perturbations in pancreas cancer cells with 10 s integration times. NAD(P)H light-sheet FLIM in vivo was demonstrated with live neutrophil imaging in a larval zebrafish tail wound also with 10 s integration times. Finally, the theoretical and practical imaging speeds for NAD(P)H FLIM were compared across laser scanning and light-sheet geometries, indicating a 30× to 6× acquisition speed advantage for the light sheet compared to the laser scanning geometry. Conclusions: FLIM of NAD(P)H is feasible in a light-sheet geometry and is attrac tive for 3D live cell imaging applications, such as monitoring immune cell metabolism and migration within an organism.

47 OTHER INSTRUMENTATION↗

The new MTLRS-1 receiving system

In this report, we are giving a detailed description of the new receiving system of the German Modular Transportable Laser Ranging System MTLRS-1, consisting of a spectral time and field of view filter and a Single Photon Avalanche Diode (SPAD) as a single photon detector. The system gives full day and night ranging capability to all satellites with cm accuracy.

Sperber, Peter↗

Performance optimization of detector electronics for millimeter laser ranging

The front-end electronic circuitry plays a fundamental role in determining the performance actually obtained from ultrafast and highly sensitive photodetectors. We deal here with electronic problems met working with microchannel plate photomultipliers (MCP-PMTs) and single photon avalanche diodes (SPADs) for detecting single optical photons and measuring their arrival time with picosecond resolution. The performance of available fast circuits is critically analyzed. Criteria for selecting the most suitable electronics are derived and solutions for exploiting the detector performance are presented and discussed.

Cova, Sergio↗

InGaAsP Avalanche Photodetectors for Non-Gated 1.06 micrometer Photon-Counting Receivers

The efficient detection of single photons at 1.06 micron is of considerable interest for lidar/ladar systems designed for remote sensing an d ranging as well as for free-space optical transmission in photon-st arved applications. However, silicon-based single photon avalanche diodes (SPADs) used at shorter wavelengths have very low single photon d etection efficiency (approximately 1 - 2%) at 1.06 micron, and InP/In GaAs SPADs designed for telecommunications wavelengths near 1.5 micro n exhibit high dark count rates that generally inhibit non-gated (free-running) operation. To bridge this "single photon detection gap" for wavelengths just beyond 1 micron, we have developed high performance , large area (80 - 200 micron diameter) InP-based InGaAsP quaternary absorber SPADs optimized for operation at 1.06 micron and based on a highly reliable planar geometry avalanche photodiode structure. We wil l show that dark count rates are sufficiently low to allow for non-ga ted operation while achieving detection efficiencies far surpassing t hose found for Si SPADs. At a detection efficiency of 10%, 80 micron diameter devices exhibit dark count rates below 1000 Hz and count rate s of at least 3 MHz when operated at -40 C. Significantly higher dete ction efficiencies (30 - 50%) are achievable with acceptable tradeoff s in dark count rate. In this paper, we will also discuss performance modeling for these devices and compare their behavior with longer wav elength InP-based InGaAs ternary absorber SPADs fabricated on a relat ed device design platform.

Itzler, Mark A.↗

Fast data-driven spectrometer with direct measurement of time and frequency for multiple single photons

We present a single-photon-sensitive spectrometer based on a linear array of 512 single-photon avalanche diode detectors with 0.04 nm spectral and 40 ps temporal resolutions. We employ a fast data-driven operation that allows direct measurement of time and frequency for simultaneous single photons, time- and frequency-stamping each single-photon detection. Our results combine excellent temporal and spectral resolution. This work opens numerous applications in quantum photonics, especially when both spectral and temporal properties of single photons can be exploited.

79 ASTRONOMY AND ASTROPHYSICS↗

How to squeeze high quantum efficiency and high time resolution out of a SPAD

We address the issue whether Single-Photon Avalanche Diodes (SPADs) can be suitably designed to achieve a trade-off between quantum efficiency and time resolution performance. We briefly recall the physical mechanisms setting the time resolution of avalanche photodiodes operated in single-photon counting, and we give some criteria for the design of SPADs with a quantum efficiency better than l0 percent at 1064 nm together with a time resolution below 50 ps rms.

Lacaita, A.↗

Characterization of Digital Silicon Photomultipliers

Digital Silicon photomultipliers (Digital SiPMs) have become an increasingly viable option for single-photon detection due to their compact size and precise timing and resolution. The following work characterizes the noise performance of a diSiPM designed and tested in-house at Fermilab. The SiPM consists of a 26x32 array of single-photon avalanche diode (SPAD) cells. Through the implementation of a shift register masking circuit, individual SPAD cells can be enabled and disabled at will, allowing for precise detection measurements of single columns (accumulator channels) and cells. The provided circuit design operates on voltage clock pulses and collects data on clock edges allowing for precise tuning of the data collection process by varying the clock frequency, pulse width, and integration period.

Shoemaker, Oliver [U. Chicago (main)]↗

Fast neutron radiography-based on single-photon digital photosensor: concept and demonstration

For decades, fast neutron radiography performed using pulse-counting detectors employed PMTs coupled to plastic scintillator pixel arrays. SiPM-based systems are now sought to replace fragile PMTs, but conventional, “analog” SiPMs suffer from intrinsic limitations which limit their achievable performance. Among these limitations, a complete analog readout and digitizer chain is required, a counterintuitive approach when considering that the single-photon avalanche diode (SPAD), the basic unit cell of SiPMs, is a Boolean detector providing digital detection at the sensor level. This paper outlines a new concept for neutron radiography instrumentation by using photon-to-digital converters (PDCs, aka digital SiPMs), a fully digital solution to sense the scintillation light.

Pratte, Jean-Francois↗

Quantum ghost imaging microscopy depth-of-field study

Quantum ghost imaging approaches have been proposed to enhance biological microscopy, for example, using 2D visible detectors to provide IR images or providing additional dimensions of spatial or spectral information. Toward the goal of making such imaging schemes practical, we compare image quality and depth-of-field between traditional images and ghost images at the same excitation levels. We measure how image quality and depth-of-field depend on the parameters of the entangled light produced using type-I spontaneous parametric down-conversion (SPDC). We use a pair of time-synchronized, photon-timing single-photon avalanche diode (SPAD) array detectors to capture two distinct microscope imaging paths simultaneously on a photon-pair-by-photon-pair basis: one in a traditional imaging pathway and the other a quantum ghost imaging pathway. We calculate the depth-of-field, resolution, contrast, and signal-to-noise ratio (SNR) through the parameter space of a β-Barium Borate (BBO) type-I bulk non-linear crystal length and angle. Our results provide a basis for choosing parameters for quantum ghost imaging with type-I SPDC sources.

47 OTHER INSTRUMENTATION↗

Undulator radiation of single electrons: coherence length and quantum-optical properties

The aims of the CLARA experiment at the Fermilab Integrable Optics Test Accelerator (IOTA) were to directly measure the coherence length of undulator radiation emitted by a single electron and to test whether the radiation is in a pure classical Glauber coherent state or in a quantum mixture of coherent and Fock states. We used a Mach-Zehnder interferometer (MZI) to study visible radiation generated by 150-MeV electrons circulating in the ring. The relative delay between the two arms of the MZI was adjusted by varying the length of one of them with a resolution of 10 nm. The intensity of the circulating beam spanned several orders of magnitude, down to single electrons. A pair of single-photon avalanche diodes (SPADs) was placed at the output of the MZI arms to detect photocounts with high efficiency and timing resolution. We describe the observed interference patterns and photocount rates as a function of interferometer delay and discuss their implications.

43 PARTICLE ACCELERATORS↗

Undulator Radiation of Single Electrons: Coherence Length and Quantum-Optical Properties

The aims of the CLARA experiment at the Fermilab Integrable Optics Test Accelerator (IOTA) were to directly measure the coherence length of undulator radiation emitted by a single electron and to test whether the radiation is in a pure classical Glauber coherent state or in a quantum mixture of coherent and Fock states. We used a Mach-Zehnder interferometer (MZI) to study visible radiation generated by 150-MeV electrons circulating in the ring. The relative delay between the two arms of the MZI was adjusted by varying the length of one of them with a resolution of 10 nm. The intensity of the circulating beam spanned several orders of magnitude, down to single electrons. A pair of single-photon avalanche diodes (SPADs) was placed at the output of the MZI arms to detect photocounts with high efficiency and timing resolution. We describe the observed interference patterns and photocount rates as a function of interferometer delay and discuss their implications.

43 PARTICLE ACCELERATORS↗

Tracking capabilities of SPADs for laser ranging

The spatial sensitivity of Single-Photon Avalanche Diodes (SPADs) can be exploited in laser ranging measurements to finely tune the laser spot in the center of the detector sensitive area. We report the performance of a SPAD with l00 micron diameter. It features a time resolution better than 80 ps rms when operated 4V above V(b) at minus 30 C, and a spatial sensitivity better than 20 microns to radial displacements of the laser spot. New SPAD structures with auxiliary delay detectors are proposed. These improved devices could allow a two dimensional sensitivity, that could be employed for the design of pointing servos.

Zappa, F.↗

Negative feedback avalanche diode

A single-photon avalanche detector is disclosed that is operable at wavelengths greater than 1000 nm and at operating speeds greater than 10 MHz. The single-photon avalanche detector comprises a thin-film resistor and avalanche photodiode that are monolithically integrated such that little or no additional capacitance is associated with the addition of the resistor.

Itzler, Mark Allen↗

Multifrequency-resolved Hanbury Brown–Twiss effect

The Hanbury Brown–Twiss (HBT) effect holds a pivotal place in intensity interferometry and gave a seminal contribution to the development of quantum optics. To observe such an effect, both good spectral and timing resolutions are necessary. Most often, the HBT effect is observed for a single frequency at a time due to its limitations in dealing with multifrequencies simultaneously, halting and limiting some applications. Here, we report a fast and data-driven spectrometer built with a one-dimensional array of single-photon-sensitive avalanche diodes. We report observing the HBT effect for multiple frequencies at the same time. In particular, we observe the HBT effect for up to five lines of the Ne spectrum, but this can be improved upon to include more lines. Our work represents a major step in making spectral binning and multifrequency HBT more widely available. The technology we present can benefit both classical and quantum applications.

79 ASTRONOMY AND ASTROPHYSICS↗

NIR fluorescence lifetime macroscopic imaging with a novel time-gated SPAD camera

SwissSPAD3 is the latest of a family of widefield time-gated SPAD imagers developed for fluorescence lifetime imaging (FLI) applications. Its distinctive features are (i) the ability to define shorter gates than its predecessors (width W < 1 ns), (ii) support for laser repetition rates up to at least 80 MHz and (iii) a dual-gate architecture providing an effective duty cycle of 100%. We present widefield macroscopic FLI measurements of short lifetime NIR dyes, analyzed using the phasor approach. Furthermore, the results are compared with those previously obtained with SwissSPAD2 and to theoretical predictions.

47 OTHER INSTRUMENTATION↗

UV hybrid photon detector based on GaN photocathodes and Si low gain avalanche diode

Photon detectors featuring single-photon sensitivity play a crucial role in various scientific domains, including high-energy physics, astronomy, and quantum optics. Fast response time, high quantum efficiency, and minimal dark counts are the characteristics that render them ideal candidates for detecting individual photons with exceptional signal-to-noise ratios, at frequencies in the range of hundreds of MHz. Here, in this study, we report on our first design and operational results on a Hybrid Photon Detector (HPD) that combines the high quantum efficiency of a Gallium Nitride (GaN) photocathode and the low noise characteristics of a Si-based Low-Gain Avalanche Diode (LGAD). This hybrid detection scheme has the potential to reach single-photon detection sensitivity with high quantum efficiency, low noise levels and capable of operating at hundreds of MHz repetition rates.

47 OTHER INSTRUMENTATION↗