Search NASA⌕ Search

SEARCH · Search NASA

Results for “single-molecule 3D structure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

LoTToR: An Algorithm for Missing-Wedge Correction of the Low-Tilt Tomographic 3D Reconstruction of a Single-Molecule Structure (LoTToR) v1.0

The low-tilt tomographic reconstruction (LoTToR) method is a post-processing method to correct the missing-wedge artifact, which contains a model-free iteration process under a set of constraints in real and reciprocal spaces. A proof of concept is conducted by using the LoTToR on a phantom, i.e., a simulated 3D reconstruction from a low-tilt series of images, including that within a tilt range of ±15°. The method is validated by using both negative-staining (NS) and cryo-electron tomography (cryo-ET) experimental data. A significantly reduced missing-wedge artifact verifies the capability of LoTToR, suggesting a new tool to support the future study of macromolecular dynamics, fluctuation and chemical activity from the viewpoint of single-molecule 3D structure determination. Moreover, the software can be used for hospital computer tomography (CT) to reduce the radiation damage to patients without reducing the CT image quality.

Ren, Gang↗

LoTToR: An Algorithm for Missing-Wedge Correction of the Low-Tilt Tomographic 3D Reconstruction of a Single-Molecule Structure

A single-molecule three-dimensional (3D) structure is essential for understanding the thermal vibrations and dynamics as well as the conformational changes during the chemical reaction of macromolecules. Individual-particle electron tomography (IPET) is an approach for obtaining a snap-shot 3D structure of an individual macromolecule particle by aligning the tilt series of electron tomographic (ET) images of a targeted particle through a focused iterative 3D reconstruction method. The method can reduce the influence on the 3D reconstruction from large-scale image distortion and deformation. Due to the mechanical tilt limitation, 3D reconstruction often contains missing-wedge artifacts, presented as elongation and an anisotropic resolution. Here, we report a post-processing method to correct the missing-wedge artifact. This low-tilt tomographic reconstruction (LoTToR) method contains a model-free iteration process under a set of constraints in real and reciprocal spaces. A proof of concept is conducted by using the LoTToR on a phantom, i.e., a simulated 3D reconstruction from a low-tilt series of images, including that within a tilt range of ±15°. The method is validated by using both negative-staining (NS) and cryo-electron tomography (cryo-ET) experimental data. A significantly reduced missing-wedge artifact verifies the capability of LoTToR, suggesting a new tool to support the future study of macromolecular dynamics, fluctuation and chemical activity from the viewpoint of single-molecule 3D structure determination.

97 MATHEMATICS AND COMPUTING↗

Angle between DNA linker and nucleosome core particle regulates array compaction revealed by individual-particle cryo-electron tomography

Abstract The conformational dynamics of nucleosome arrays generate a diverse spectrum of microscopic states, posing challenges to their structural determination. Leveraging cryogenic electron tomography (cryo-ET), we determine the three-dimensional (3D) structures of individual mononucleosomes and arrays comprising di-, tri-, and tetranucleosomes. By slowing the rate of condensation through a reduction in ionic strength, we probe the intra-array structural transitions that precede inter-array interactions and liquid droplet formation. Under these conditions, the arrays exhibite irregular zig-zag conformations with loose packing. Increasing the ionic strength promoted intra-array compaction, yet we do not observe the previously reported regular 30-nanometer fibers. Interestingly, the presence of H1 do not induce array compaction; instead, one-third of the arrays display nucleosomes invaded by foreign DNA, suggesting an alternative role for H1 in chromatin network construction. We also find that the crucial parameter determining the structure adopted by chromatin arrays is the angle between the entry and exit of the DNA and the corresponding tangents to the nucleosomal disc. Our results provide insights into the initial stages of intra-array compaction, a critical precursor to condensation in the regulation of chromatin organization.

59 BASIC BIOLOGICAL SCIENCES↗

Cryo-electron tomography related radiation-damage parameters for individual-molecule 3D structure determination

To understand the dynamic structure–function relationship of soft- and biomolecules, the determination of the three-dimensional (3D) structure of each individual molecule (nonaveraged structure) in its native state is sought-after. Cryo-electron tomography (cryo-ET) is a unique tool for imaging an individual object from a series of tilted views. However, due to radiation damage from the incident electron beam, the tolerable electron dose limits image contrast and the signal-to-noise ratio (SNR) of the data, preventing the 3D structure determination of individual molecules, especially at high-resolution. Although recently developed technologies and techniques, such as the direct electron detector, phase plate, and computational algorithms, can partially improve image contrast/SNR at the same electron dose, the high-resolution structure, such as tertiary structure of individual molecules, has not yet been resolved. Here, we review the cryo-electron microscopy (cryo-EM) and cryo-ET experimental parameters to discuss how these parameters affect the extent of radiation damage. This discussion can guide us in optimizing the experimental strategy to increase the imaging dose or improve image SNR without increasing the radiation damage. With a higher dose, a higher image contrast/SNR can be achieved, which is crucial for individual-molecule 3D structure. With 3D structures determined from an ensemble of individual molecules in different conformations, the molecular mechanism through their biochemical reactions, such as self-folding or synthesis, can be elucidated in a straightforward manner.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Aromatic Amide Foldamers Show Conformation‐Dependent Electronic Properties

Electron transport in organic molecules and biomolecules is governed by electronic structure and molecular conformations. Despite recent progress, key challenges remain in understanding the role of intramolecular interactions and three-dimensional (3D) conformations on the electron transport behavior of organic molecules. In this work, the electronic properties of aromatic amide foldamers are characterized that organize into distinct 3D structures, including an extended secondary amide that adopts a trans-conformation and a folded N-methylated tertiary amide that adopts a cis-conformation. Results from single-molecule electronic experiments show that the extended secondary amide exhibits a fourfold enhancement in molecular conductance compared to the folded N-methylated tertiary amide, despite a longer contour length. The results show that extended amide molecules are governed by a through-bond electron transport mechanism, whereas folded amide molecules are dominated by through-space transport. Bulk spectroscopic characterization and density functional theory calculations further reveal that extended amides have a smaller HOMO–LUMO gap and larger transmission values compared to folded amides, consistent with single-molecule electronic experiments. Overall, this work shows that 3D molecular conformations significantly influence the electronic properties of single-molecule junctions.

electron transport↗

Non-averaged single-molecule tertiary structures reveal RNA self-folding through individual-particle cryo-electron tomography

Large-scale and continuous conformational changes in the RNA self-folding process present significant challenges for structural studies, often requiring trade-offs between resolution and observational scope. Here, we utilize individual-particle cryo-electron tomography (IPET) to examine the post-transcriptional self-folding process of designed RNA origami 6-helix bundle with a clasp helix (6HBC). By avoiding selection, classification, averaging, or chemical fixation and optimizing cryo-ET data acquisition parameters, we reconstruct 120 three-dimensional (3D) density maps from 120 individual particles at an electron dose of no more than 168 e - Å -2 , achieving averaged resolutions ranging from 23 to 35 Å, as estimated by Fourier shell correlation (FSC) at 0.5. Each map allows us to identify distinct RNA helices and determine a unique tertiary structure. Statistical analysis of these 120 structures confirms two reported conformations and reveals a range of kinetically trapped, intermediate, and highly compacted states, demonstrating a maturation folding landscape likely driven by helix-helix compaction interactions.

36 MATERIALS SCIENCE↗

Single-molecule 3D imaging of HIV cellular entry by liquid-phase electron tomography

Enveloped viruses, including human immunodeficiency virus (HIV) and SARS-CoV-2, target cells through membrane fusion process. The detailed understanding of the process is sought after for vaccine development but remains elusive due to current technique limitations for direct three-dimensional (3D) imaging of an individual virus during its viral entry. Recently, we developed a simple specimen preparation method for real-time imaging of metal dynamic liquid-vaper interface at nanometer resolution by transmission electron microscopy (TEM). Here, we extended this method to study biology sample through snapshot 3D structure of a single HIV (pseudo-typed with the envelope glycoprotein of vesicular stomatitis virus, VSV-G) at its intermediate stage of viral entry to HeLa cells in a liquid-phase environment. By individual-particle electron tomography (IPET), we found the viral surface release excess lipids with unbound viral spike proteins forming ~50-nm nanoparticles instead of merging cell membrane. Moreover, the spherical-shape shell formed by matrix proteins underneath the viral envelope does not disassemble into a cone shape right after fusion. Further, the snapshot 3D imaging of a single virus provides us a direct structure-based understanding of the viral entry mechanism, which can be used to examine other viruses to support the development of vaccines combatting the current ongoing pandemic.

Kong, Lingli↗

A Nanosized {Ni II 18 } Cluster with a ‘Flying Saucer’ Topology Exhibiting Slow Relaxation of Magnetisation Phenomena at Both 15 K and 1.3 K

A high-nuclearity {Ni 18 } complex (1) with a unique ‘flying saucer’ motif has been prepared from the organic chelate, α-methyl-2-pyridine-methanol (mpmH), in conjunction with bridging azido (N 3 - ) and peroxido (O 2 2- ) ligands. Magnetic susceptibility measurements revealed the presence of both ferro- and antiferromagnetic exchange interactions between the metal centres in 1, and the stabilization of spin states with appreciable S values at two different temperature regimes. The end-on bridging azido and alkoxido groups are in all likelihood the ferromagnetic mediators, while the η 3 :η 3 :μ 6 -bridging peroxides most likely promote the antiparallel alignment of the metals’ spin vectors, yielding an overall non-zero spin ground state for the centrosymmetric compound 1. Furthermore, the {Ni 18 } nanosized cluster behaves as a single-molecule magnet, exhibiting magnetic hysteresis at low temperatures and two relaxation processes at 15 K and 1.3 K, a very rare phenomenon in polynuclear magnetic 3d-metal clusters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Facile hermetic TEM grid preparation for molecular imaging of hydrated biological samples at room temperature

Abstract Although structures of vitrified supramolecular complexes have been determined at near-atomic resolution, elucidating in situ molecular structure in living cells remains a challenge. Here, we report a straightforward liquid cell technique, originally developed for real-time visualization of dynamics at a liquid-gas interface using transmission electron microscopy, to image wet biological samples. Due to the scattering effects from the liquid phase, the micrographs display an amplitude contrast comparable to that observed in negatively stained samples. We succeed in resolving subunits within the protein complex GroEL imaged in a buffer solution at room temperature. Additionally, we capture various stages of virus cell entry, a process for which only sparse structural data exists due to their transient nature. To scrutinize the morphological details further, we used individual particle electron tomography for 3D reconstruction of each virus. These findings showcase this approach potential as an efficient, cost-effective complement to other microscopy technique in addressing biological questions at the molecular level.

59 BASIC BIOLOGICAL SCIENCES↗

Sequence-defined Pareto frontier of a copolymer structure

The correlations between the sequence of monomers in a macromolecule and its three-dimensional (3D) structure is a grand challenge in polymer science. The properties and functions of macromolecules depend on their 3D shape that has appeared to be dictated by their monomer sequence. However, the progress towards understanding the sequence–structure-property correlations and their utilization in materials engineering are slow because it is almost impossible to characterize an astronomically large number of possible sequences of a copolymer using traditional experimental and simulation methods. To address this problem, here, we combine evolutionary computing and coarse-grained molecular dynamics (CGMD) simulation and study the sequence-structure correlations of a model AB-type copolymer in a solution and assess the impact of sequence on the packing density in its bulk phase. The CGMD-based evolutionary algorithm (EA) screens the sequence space of a single chain copolymer efficiently and identifies a wide range of single-molecule structures including extremal radii of gyration. The data are utilized to estimate the Pareto front of the structure-space of a binary copolymer as a function of its composition. The monomer packings in single-molecule solution phase and multimolecular bulk phase are found to be identical. Finally, this work highlights the opportunities of sequence-specific control of macromolecular structure for designing target materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Planar 2D wireframe DNA origami

Two-dimensional (2D) DNA origami is widely used for applications ranging from excitonics to single-molecule biophysics. Conventional, single-layer 2D DNA origami exhibits flexibility and curvature in solution; however, that may limit its suitability as a 2D structural template. In contrast, 2D wireframe DNA origami rendered with six-helix bundle edges offers local control over duplex orientations with enhanced in-plane rigidity. Here, we investigate the 3D structure of these assemblies using cryo–electron microscopy (cryo-EM). 3D reconstructions reveal a high degree of planarity and homogeneity in solution for polygonal objects with and without internal mesh, enabling 10-Å resolution for a triangle. Coarse-grained simulations were in agreement with cryo-EM data, offering molecular structural insight into this class of 2D DNA origami. Our results suggest that these assemblies may be valuable for 2D material applications and geometries that require high structural fidelity together with local control over duplex orientations, rather than parallel duplex assembly.

59 BASIC BIOLOGICAL SCIENCES↗

Development of high throughput light-sheet fluorescence lifetime imaging microscopy for 3D functional imaging of metabolic pathways in plant and microorganisms (Final Technical Report)

This research program will enable new biochemical contrast in the nanosecond lifetime domain through use of the recently demonstrated electro-optic fluorescence lifetime imaging technique (EO-FLIM) for wide-field lifetime imaging. The Stanford/Stanford Linear Accelerator Center multidisciplinary collaboration -- physics, applied physics, and structural biology -- will develop a light-sheet fluorescence lifetime imaging microscope for functional studies of microbial and plant metabolic pathways and dynamic interactions between plants and microorganisms in the rhizosphere. The proposed approach overcomes the imaging time bottleneck associated with existing fluorescence lifetime imaging methods. Initial demonstrations have shown a factor of 100,000 improvement in photon throughput compared to existing methods. High photon efficiency allowed the first wide-field fluorescence lifetime imaging of single molecules. Recent work has improved the technique’s repetition rate to enable compatibility with mode-locked lasers and demonstrated the combination of wide-field fluorescence lifetime imaging with super-resolution localization microscopy, observations of single molecule dynamics, and observation of donor lifetime quenching in single-molecule imaging. These results were achieved on standard camera sensors and would not have been possible with other wide-field approaches. The throughput and photon economy of the EO-FLIM method enables new BER-relevant imaging opportunities. In particular, scanned single- and two-photon light-sheet excitation will be used to achieve volumetric imaging with time-domain contrast.

47 OTHER INSTRUMENTATION↗