Preliminary results from a single-photon imaging X-ray charge coupled device /CCD/ camera

A CCD camera is described which has been designed for single-photon X-ray imaging in the 1-10 keV energy range. Preliminary results are presented from the front-side illuminated Fairchild CCD 211, which has been shown to image well at 3 keV. The problem of charge-spreading above 4 keV is discussed by analogy with a similar problem at infrared wavelengths. The total system noise is discussed and compared with values obtained by other CCD users.

Griffiths, R. E.↗

Experimental tests of a single-photon calorimeter for X-ray spectroscopy

Tests have been made of a nondispersive spectroscopic X-ray detector which operates by measuring the temperature rise following absorption of a single photon. Thermal pulses from 6-keV X-rays have been observed, and the different amplitudes resulting from Mn K-alpha and K-beta events have been resolved. This device was assembled to make quantitative tests of theoretical calculations of the properties of such detectors, and its high heat capacity does not allow it to attain the very high resolution predicted for detectors made by more sophisticated, but still straightforward, techniques. Both the measured resolution of 270-eV full width at half maximum and the absolute amplitude of the response are consistent with predictions. Nonthermal effects in the thermistor limit the precision of this comparison to about 30 percent.

Mccammon, D.↗

Solid-State Single-Photon Counter

Avalanche photodiode used to detect single photons if cooled to optimum temperature and overbiased beyond breakdown voltage. Offers two to three times sensitvity of photomultiplier tubes commonly used for photon detection. When cooled to reduce number of thermal carriers, avalanche photodiode reverse-biased beyond normal breakdown voltage to give it extremely-high internal gain of 10 to seventh power to 10 to eigth power. Advantages of solid-state devices to applications requiring low-level light detection, optical communication, astronomy, remote sensing, optical metrology, and optical signal processing.

Robinson, D. L.↗

Photon detection with cooled avalanche photodiodes

Commercial avalanche photodiodes have been operated as single-photon detectors at an optimum operating temperature and bias voltage. These detectors were found to be 1.5-3 times more sensitive than presently available photomultiplier tubes (PMTs). Both single-photon detection probability and detector noise increase with bias voltage; detection probabilities greater than twice that of a PMT were obtained with detector noise levels below 100 counts per second. Higher probabilities were measured at higher noise levels. The sources of noise and their dependence on temperature and bias voltage are discussed.

Robinson, D. L.↗

Cooled avalanche photodiode used for photon detection

Commercial avalanche photodiodes have been operated as single-photon detectors at an optimum operating temperature and bias voltage. These detectors were found to be 1.5 to 3 times more sensitive than presently-available photomultiplier tubes (PPMTs). Both single-photon detection probability and detector noise increase with bias voltage; detection probabilities greater than 25 percent were obtained with detector noise levels comparable to the noise of a PMT; higher probabilities were measured at higher noise levels. The sources of noise and their dependence on temperature and bias voltage are discussed.

Robinson, Deborah L.↗

Polarization phenomena in multiphoton ionization of atoms

The theory of multiphoton ionization for an atomic system of arbitrary complexity is developed using a density matrix formalism. An expression is obtained which determines the differential N-photon ionization cross section as a function of the polarization states of the target atom and the incident radiation. The parameters which characterize the photoelectron angular distribution are related to the general reduced matrix elements for the N-photon transition. Two-photon ionization of unpolarized atoms is treated as an illustration of the use of the theory. The dependence of the multiphoton ionization cross section on the polarization state of the incident radiation, which has been observed in two- and three-photon ionization of Cs, is accounted for by the theory. Finally, the photoelectron spin polarization produced by the multiphoton ionization of unpolarized atoms, like the analogous polarization resulting from single-photon ionization, is found to depend on the circular polarization of the incident radiation.

Jacobs, V. L.↗

Polarization phenomena in multiphoton ionization of atoms.

The theory of multiphoton ionization for an atomic system of arbitrary complexity is developed using a density matrix formalism. An expression is obtained which determines the differential N-photon ionization cross section as a function of the polarization states of the target atom and the incident radiation. The parameters which characterize the photo-electron angular distribution are related to the general reduced matrix elements for the N-photon transition. Two-photon ionization of unpolarized atoms is treated as an illustration of the use of the theory. The dependence of the multiphoton ionization cross section on the polarization state of the incident radiation, which has been observed in two- and three-photon ionization of Cs, is accounted for by the theory. Finally, the photoelectron spin polarization produced by the multiphoton ionization of unpolarized atoms, like the analogous polarization resulting from single-photon ionization, is found to depend on the circular polarization of the incident radiation.

Jacobs, V. L.↗

High-resolution imaging X-ray detector

The paper describes an X-ray detector using microchannel plates as a photocathode surface and imaging photoelectron multiplier, and a crossed wire grid as a two-dimensional position-sensitive detector. The position resolution is 10 microns. The crossed wire grid consists of 100-micron-diam wires on 200-micron centers. Position sensing is accomplished by electronic interpolation to 1/20 of the wire spacing. The quantum efficiency of the microchannel plates varies from 29% at 0.28 keV to 5% at 3 keV. This detector will provide second-of-arc X-ray imaging in the focal plane of the 342.9-cm focal length grazing-incidence telescope being prepared for the HEAO-B observatory. By addition of suitable photocathodes, it can be used for single-photon imaging light detection in the UV, visible, and near-IR-ranges. In all cases, it gives a very low dark counting rate, allows timing of individual events to 1 microsec or less, and can handle counting rates up to 10,000 per sec.

Kellogg, E.↗

The High Resolution Imaging Instrument for HEAO-B

The High Resolution Imaging Instrument for the HEAO-B X-ray Telescope satellite is designed to reproduce images of celestial X-ray sources in the range of 0.2 to 4.0 keV. It provides both imaging and temporal data. The basic detector is a two-stage microchannel plate with a crossed-grid charge detector. Preamplifiers, detector bias supplies, and some processing circuits are colocated with the detector. The remaining electronic circuits are located in a remote central electronic assembly. The processing system is designed for single-photon processing. The imaging data rate is limited to 100 data points per second. Non-imaging total-field count rate is acquired with a maximum dead time of 14 microseconds per event.

Kubierschky, K.↗

Overview of laser applications to chemistry

The discussion is in three parts. First, laser spectroscopy is discussed with consideration given to single-photon and multiphoton processes. Second, attention is given to the use of lasers in studying molecular interactions and reaction dynamics. Finally, the paper discusses the relationship between chemistry and laser development.

George, T. F.↗

A low-energy gamma-ray imaging detector

We describe a hard-X-ray/soft-gamma-ray imaging detector, incorporating a microchannel-plate (MCP) electron multiplier for possible use in future telescopes. In contrast to previous attempts using MCP's this approach promises to achieve high quantum detection efficiencies in addition to high spatial and temporal resolution. Preliminary results indicate not only the capability of simultaneous imaging and single-photon counting, but also coarse energy resolution.

Yin, L. I.↗

New position-sensitive hard X-ray spectrometer

The design and features of a new prototype Lixiscope (Low intensity X-ray imaging scope) is described. It is shown that in addition to good spatial and temporal resolution in the 20 keV to 200 keV region, it is capable of single-photon counting, imaging as well as good energy resolution. It is concluded that the device is well suited for future low-flux applications in astronomy, medicine, and industry.

Yin, L. I.↗

Improved Lixiscope

Improved lixiscope utilizes fast-decay scintillators and multiple or curved microchannels to achieve high energy and spatial resolution as well as single-photon counting. New unit, with higher energy resolution, is intended for X-ray astronomy, although it could be applied terrestrially wherever a sensitive portable radiation spectrometer is required for 20-to-200-keV range.

Yin, L. I.↗

Evaluation of a virtual phase charged-coupled device as an imaging X-ray spectrometer

The X-ray response of an 800 x 800 Texas Instruments virtual phase charge-coupled device (CCD) has been measured in the range 1-8 keV. In the single-photon counting mode, excellent energy resolution (approximately 250 eV FWHM is found for single-pixel Fe-55 X-ray events at a spatial resolution of 15 microns. The detector quantum efficiency for all events is 65% at 2.3 keV (S K line) and approximately 34% at 5.9 keV (Mn K line from Fe-55). The CCD response is linear in energy to a few percent over the 1-8 keV energy range. These results demonstrate that virtual phase CCDs are superior imaging X-ray spectrometers with applications for X-ray astronomy and laboratory plasma research.

Stern, R. A.↗

Relative fine-structure intensities in two-photon excitation

A discrepancy is pointed out between experimental determinations of the relative intensities for different fine-structure components of the two-photon transitions 2p3P 3p3P in oxygen and 2p3 4S0 - 2p2 3p4D0 in nitrogen, which agreed well with calculations involving a single virtual intermediate level, and a two-photon selection rule dJ not equal to one, derived in a purely theoretical and erroneous treatment of these transitions. Five other experiments are also briefly examined, with the conclusion that relative fine-structure intensities in two-photon transitions are well understood as straightforward extensions of angular momentum coupling in single-photon cases, in accordance with allowed dJ = 0, + or -1, and + or -2 transitions.

Crosley, D. R.↗

Nondispersive X-ray spectroscopy and imaging of plasmas using a charge-coupled device

A virtual-phase charge-coupled device (CCD) was used to obtain pinhole images and X-ray spectra of laser-produced, solid target plasmas. With the CCD used in the single-photon counting mode, the spectrum in the energy range 2-10 keV was obtained without a dispersive element. Typical spectra reveal two distinct temperatures: a cold component of approximately 200 eV and a hot component of approximately 5 keV. Also, multiline spectra comprising characteristic line emission (K alpha, K beta) from a multilayer target bombarded by beta-rays were recorded using a three-phase CCD. The results demonstrate the potential of CCDs as imaging spectrometers with application in space, laboratory, and fusion-plasma research.

Marsh, K.↗