Search NASA⌕ Search

SEARCH · Search NASA

Results for “site location”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Connecting cation site location to alkane dehydrogenation activity in Ni/BEA catalysts

Ni-modified beta zeolite (Ni/BEA) catalysts activate carbon-hydrogen bonds in light alkanes, as demonstrated through isobutane reaction testing. Controlled synthesis of Ni/BEA allows for efficient introduction of ion-exchanged Ni sites at varying Ni loadings (0.43% - 1.8%). These catalysts exhibit site time yields (STY) for H2 production that increase with increasing Ni loading. A detailed analysis of secondary reactions and carbon deposition based on the relative molar flowrates of product C and H indicates that the observed increase in H2 STY with increasing Ni loading is likely attributed to both increasing alkane activation activity and increasing formation of hydrogen-deficient aromatic products retained within the catalyst pores. In situ diffuse-reflectance UV-visible-NIR absorbance and X-ray absorption spectroscopies indicate isolated, 4-coordinate Ni(2+) species for all loadings. Quantum mechanics/molecular mechanics modeling identifies two distinct Ni(2+) sites consistent with the structural characterization, but with differing relative stabilities due to their coordination environment. Computed reaction energetics for isobutane dehydrogenation demonstrate that the more stable Ni(2+) species at a six-membered 4Si-2Al ring, Ni-6MR, is less active for isobutane dehydrogenation than the less stable Ni(2+) at the five-membered 3Si-2Al ring, Ni-5MR. The differing local structure of the isolated cationic Ni sites in Ni/BEA offers a possible rationalization for the increased H2 STY observed at greater Ni loadings.

catalysts↗

GIS modeling of archaeological site locations: A low-tech approach

A Geographic Information System (GIS)-type analysis of archaeological site locations using a dBase III plus program and a desk top computer is presented. A previously developed model of site locations in the Sequatchie Valley of northeastern Alabama is tested against known site locations in another large survey area there. The model fails to account for site locations in the test area. A model is developed for the test area and indicates the site locations are indeed different. Whether this is due to differences in site locations on a sub-regional level, or to sample error in the original model is unknown.

Futato, Eugene M.↗

Analyzing the Radio Frequency Interference Environment at Cal/Val Site Locations for the Soil Moisture Active/Passive (SMAP) Mission

The Soil Moisture Active/Passive satellite was launched in 2015 to provide global and continuous maps of land surface soil moisture and freeze-thaw using L-Band microwave radiometry. Even though the 1400-1427 MHz frequency used by SMAP is a protected portion of the spectrum, Radio Frequency Interference (RFI) is still observed that can corrupt the radiometer’s measurements. Nine distinct algorithms are implemented as part of SMAP’s level 1 processing to detect and filter out RFI contributions. However, any remaining undetected RFI are major concern especially at the locations of cal/val sites used for evaluating soil moisture retrieval performance. This paper presents an analysis of the RFI environment at SMAP cal/val site locations and assesses the impact of RFI on soil moisture retrievals at those locations.

Misra, S.↗

Validation of Innovative Exploration Technologies for Newberry Volcano: Drill Site Location Map

Newberry seeks to explore "blind" (no surface evidence) convective hydrothermal systems associated with a young silicic pluton on the flanks of Newberry Volcano. This project will employ a combination of innovative and conventional techniques to identify the location of subsurface geothermal fluids associated with the hot pluton. Newberry project drill site location map 2010. This submission contains a topographic drill site location map.

15 GEOTHERMAL ENERGY↗

The impact of an efficient collection sites location on the zoning phase in municipal solid waste management

Highlights: • We study the problems of locating collection areas and zoning the service territory in a municipal waste management system. • We investigate the impact that an efficient collection sites location has on the subsequent zoning phase. • On a real-world test case, we show that the proposed approach could allow achieving significant monetary savings. - Abstract: In this paper, we study two decisional problems arising when planning the collection of solid waste, namely the location of collection sites (together with bin allocation) and the zoning of the service territory, and we assess the potential impact that an efficient location has on the subsequent zoning phase. We first propose both an exact and a heuristic approach to locate the unsorted waste collection bins in a residential town, and to decide the capacities and characteristics of the bins to be located at each collection site. A peculiar aspect we consider is that of taking into account the compatibility between the different types of bins when allocating them to collection areas. Moreover, we propose a fast and effective heuristic approach to identify homogeneous zones that can be served by a single collection vehicle. Computational results on data related to a real-life instance show that an efficient location is fundamental in achieving consistent monetary savings, as well as a reduced environmental impact. These reductions are the result of one vehicle less needed to perform the waste collection operations, and an overall traveled distance reduced by about 25% on the average.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Discovery of native metal ion sites located on the ferredoxin docking side of photosystem I.

Photosystem I (PSI) is a large membrane protein that catalyzes light-driven electron transfer across the thylakoid membrane from plastocyanin located in the lumen to ferredoxin in the stroma. Metal analysis reveals that PSI isolated from the cyanobacterial membranes of Synechococcus leopoliensis has a near-stoichiometric 1 molar equiv of Zn2+ per PSI monomer and two additional surface metal ion sites that favor Cu2+ binding. Two-dimensional hyperfine sublevel correlation (HYSCORE) spectroscopy reveals coupling to the so-called remote nitrogen of a single histidine coordinated to one of the Cu2+ centers. EPR and X-ray absorption fine structure (XAFS) studies of 2Cu?PSI complexes reveal the direct interaction of ferredoxin with the Cu2+ centers on PSI, establishing the location of native metal sites on the ferredoxin docking side of PSI. On the basis of these spectroscopic results and previously reported site-directed mutagenesis studies, inspection of the PSI crystal structure reveals a cluster of three highly conserved residues, His(D95), Glu(D103), and Asp(C23), as a likely Cu2+ binding site. The discovery of surface metal sites on the acceptor side of PSI provides a unique opportunity to probe the stromal region of PSI and the interactions of PSI with its reaction partner, the soluble electron carrier protein ferredoxin.

36 MATERIALS SCIENCE↗

Comparison of Magnetospheric Multiscale Ion Jet Signatures with Predicted Reconnection Site Locations at the Magnetopause

Magnetic reconnection at the Earths magnetopause is the primary process by which solar wind plasma and energy gains access to the magnetosphere. One indication that magnetic reconnection is occurring is the observation of accelerated plasma as a jet tangential to the magnetopause. The direction of ion jets along the magnetopause surface as observed by the Fast Plasma Instrument (FPI) and the Hot Plasma Composition Analyzer (HPCA) instrument on board the recently launched Magnetospheric Multiscale (MMS) set of spacecraft is examined. For those cases where ion jets are clearly discerned, the direction of origin compares well statistically with the predicted location of magnetic reconnection using convected solar wind observations in conjunction with the Maximum Magnetic Shear model.

Petrinec, S. M.↗

Identifying Optimal Site Location for Wind Energy Farms Considering Ecological and Social Impacts

With the increasing cost and declining availability of fossil fuels, renewable energy, specifically wind power, has become one of the fastest growing sources of energy in New Mexico. To assist with the goals set by the state’s Renewables Standard Portfolio established in 2004, the NASA DEVELOP team created three Optimal Wind Farm Suitability maps that consider social impact, ecological impact, and power production efficiency. The team utilized datasets from February 2013 – May 2018 that show vulnerable species, average wind patterns, and US Air Force Base locations. These three maps were combined into a final suitability map for optimal wind farm placement.

Joy Marich↗

Multi-Faceted Approach to Evaluate Discharge Locations at a FUSRAP Site - 18421

Following the completion of a Soil and Groundwater Remedial Investigation by USACE at a FUSRAP site located in Nassau County, New York, groundwater data indicated the presence of contaminant source(s) that had not been identified. As a result, a targeted investigation was undertaken to understand how materials were handled and disposed of at a site located in Nassau County, Long Island, New York. The FUSRAP site is a 4.3-hectare (10.5-acre) site encompassing three parcels which had historically been utilized as a nuclear materials manufacturing facility (e.g., cores, slug, and fuel elements) for reactors used in both research and electric power generation in early 1950's until late 1960's; however, the targeted investigation was on the southern-most parcel known as the '70 Property' (the Site). The 70 Property contained a building that was used for atomic fuel-element manufacturing from 1958 until 1966 under license to the Atomic Energy Commission (AEC), and involved the use of natural, enriched, and depleted uranium as well as lesser amounts of thorium. The major contaminants of concern are tetrachloroethene, nickel, uranium and thorium. During the RI, significant sources of contamination were not found in Site soils despite records indicating that chemicals and radionuclides had been disposed of on the property. In addition, downgradient groundwater data indicated a source(s) on the 70 Property that could not be identified by known sources on other the other FUSRAP parcels or from adjacent sites. This conclusion was further supported following development of groundwater contaminant transport and flow models. The main objective of the targeted investigation was to evaluate the potential discharge points on the 70 Property that may have been utilized for liquids waste disposal. However, several challenges existed including 1) lack of building construction details; 2) historical changes to Site building and property; 3) the use of the Site by various tenants; and 4) the commingling of Site contaminants with impacts from multiple sources. To overcome these challenges, historic documents/reports with information about the handling and disposal of liquid wastes were reviewed to evaluate quantities, contents and locations of waste disposal. Thereafter, an investigation was undertaken that included geophysical surveys; pipe tracing and video inspection; in-situ smoke and water testing; installation of test trenches and soil borings; and, sampling sludge residuals, soils and water within the various drainage structures that were located. This paper describes the multi-faceted investigation approach that was utilized to overcome the challenges faced during the investigation as well as insights into the waste disposal practices of the time period and the findings of the investigation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗