In situ surface/interface x-ray diffractometer for oxide molecular beam epitaxy

In situ studies of oxide molecular beam epitaxy by synchrotron x-ray scattering has been made possible by upgrading an existing UHV/molecular beam epitaxy (MBE) six-circle diffractometer system. For oxide MBE growth, pure ozone delivery to the chamber has been made available, and several new deposition sources have been made available on a new 12 in. CF (ConFlat, a registered trademark of Varian, Inc.) flange. X-ray diffraction has been used as a major probe for film growth and structures for the system. In the original design, electron diffraction was intended for the secondary diagnostics available without the necessity of the x-ray and located at separate positions. Deposition of films was made possible at the two diagnostic positions. And, the aiming of the evaporation sources is fixed to the point between two locations. Ozone can be supplied through two separate nozzles for each location. Also two separate thickness monitors are installed. Additional features of the equipment are also presented together with the data taken during typical oxide film growth to illustrate the depth of information available via in situ x-ray techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Angle calculations using two detector circles and wavelength

Here, a `2D + λ' mode using two detector angles and wavelength is added to the modes of operation of a six-circle diffractometer, i.e. `4S + 2D' diffractometer [You (1999). J. Appl. Cryst. 32, 614–623]. In synchrotron sources, the X-ray energy, and hence the wavelength, can be a degree of freedom for angle calculations. For diffractometers with two detector circles, therefore, the variable X-ray energy can be the third degree of freedom, sufficient for accessing reciprocal space without rotating the sample. This mode is useful for limited sample rotations or X-ray beams focused smaller than the diffractometer circle of confusion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modular instrument mounting system for variable environment in operando X-ray experiments

In the growing field of in operando and in situ X-ray experiments, there exists a large disparity in the types of environments and equipment to control them. This situation makes it challenging to conduct multiple experiments with a single mechanical interface to the diffractometer. Here, we describe the design and implementation of a modular instrument mounting system that can be installed on a standard six-circle diffractometer (e.g., 5021 Huber GmbH). This new system allows for the rapid changeover of different chambers and sample heaters and permits accurate sample positioning (x, y, z, and azimuthal rotation) without rigid coupling to the chamber body. Isolation of the sample motion from the chamber enclosure is accomplished through a combination of custom rotary seals and bellows. Control of the pressure and temperature has been demonstrated in the ranges of 10{sup -6}-10{sup 3} Torr and 25 Degree-Sign C-900 Degree-Sign C, respectively. We have utilized the system with several different modular instruments. As an example, we provide in situ sputtering results, where the growth dynamics of epitaxial LaGaO{sub 3} thin films on (001) SrTiO{sub 3} substrates were investigated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An agentic artificially intelligent X-ray scientist

Executing experimental tasks in both normal research laboratories and large-scale scientific facilities often requires extensive human supervision and remains a key challenge on the path to fully autonomous, artificial intelligence (AI)-driven science. Here we demonstrate a large language model-driven agent that autonomously performs X-ray sample alignment on a synchrotron beamline by planning actions, executing instrumental commands, interpreting observations and iterating towards experimental goals. Based on existing large language models with structured tool-use via the model context protocol, our AI X-ray scientist was guided and tested using an in-house-built virtual experimental setup that mirrors a six-circle diffractometer at an operational synchrotron beamline. The agentic workflow developed in the virtual environment was directly deployed on a real beamline, where it correctly identified reference reflections and determined the orientation matrix, an essential first step in any type of single-crystal scattering experiment. Our AI X-ray scientist responded effectively to unexpected experimental conditions, demonstrating adaptive problem-solving and readiness for addressing practical experimental situations. Our study provides a step towards autonomous operation across diverse experimental environments at large-scale scattering facilities.

Chen, Zhantao (ORCID:0000000319543868)↗

Data acquisition and control software for XRD beamline at Indus-2

X-ray diffraction (XRD) beamline is under commissioning on Indus-2 synchrotron radiation facility. The experimental setup of XRD beamline consists of a six-circle diffractometer and various detector systems such as scintillation detector, ionization chamber and image plate. The diffractometer can be controlled via EIA232 serial interface or Ethernet. Standard data acquisition software with a graphical user interface has been developed using LabVIEW. A firm safety and error handling scheme is implemented for failsafe operation of the experimental station. This paper describes in detail the data acquisition and control software for the experimental station.