Search NASA⌕ Search

SEARCH · Search NASA

Results for “size exclusion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Analysis of a MIL-L-27502 lubricant from a gas-turbine engine test by size-exclusion chromatography

Size exclusion chromatography was used to determine the chemical degradation of MIL-L-27502 oil samples from a gas turbine engine test run at a bulk oil temperature of 216 C. Results revealed a progressive loss of primary ester and additive depletion and the formation of higher molecular weight products with time. The high molecular weight products absorbed strongly in the ultraviolet indicating the presence of chromophoric groups.

Jones, W. R., Jr.↗

Nanofluidic Size-Exclusion Chromatograph

Efforts are under way to develop a nanofluidic size-exclusion chromatograph (SEC), which would be a compact, robust, lightweight instrument for separating molecules of interest according to their sizes and measuring their relative abundances in small samples. About as large as a deck of playing cards, the nanofluidic SEC would serve, in effect, as a laboratory on a chip that would perform the functions of a much larger, conventional, bench-top SEC and ancillary equipment, while consuming much less power and much smaller quantities of reagent and sample materials. Its compactness and low power demand would render it attractive for field applications in which, typically, it would be used to identify and quantitate a broad range of polar and nonpolar organic compounds in soil, ice, and water samples. Size-exclusion chromatography is a special case of high-performance liquid chromatography. In a conventional SEC, a sample plug is driven by pressure along a column packed with silica or polymer beads that contain uniform nanopores. The interstices between, and the pores in, the beads collectively constitute a size-exclusion network. Molecules follow different paths through the size-exclusion network, such that characteristic elution times can be related to sizes of molecules: basically, smaller molecules reach the downstream end of the column after the larger ones do because the smaller ones enter minor pores and stay there for a while, whereas the larger ones do not enter the pores. The volume accessible to molecules gradually diminishes as their size increases. All molecules bigger than a pore size elute together. For most substances, the elution times and sizes of molecules can be correlated directly with molecular weights. Hence, by measuring the flux of molecules arriving at the downstream end as a function of time, one can obtain a liquid mass spectrum for the molecules present in a sample over a broad range of molecular weights.

Feldman, Sabrina↗

Nano-fabricated size exclusion chromatograph

This paper describes the development of a nano-fabricated size exclusion chromatograph (nSEC) based on the principle that molecules traveling through amicrocolumn containing nano-fabricated features will have characteristic elution times that directly correlate to molecular weight. Compared to conventional size exclusion chromatography, the nSEC offers greater control over the size exclusion process; mass fabrication; integration of the separation column with associated valves, pumps, and detectors; and dramatic reductions in instrument mass and power requirements.

nanofluids lab-on-a-chip chromatograph separation↗

Nanofluidic size exclusion chromatograph for in site macrometer analyses

We are developing a nanofluidic size exclusion chromatograph system that can be incorporated into a miniature lab-on-a-chip devices which will provide detailed information on the geochemical and biological history of soil, ice, and water samples by identifying and qualifying a broad range of macromolecular polar and nonpolar organic compounds.

size exclusion chromatograph↗

Evaluating size exclusion chromatography for nucleic acid removal in Klebsiella pneumoniae cell surface polysaccharide purification

Cell surface-associated polysaccharides in Klebsiella are major virulence determinants and crucial targets for developing vaccines. Traditionally, the purification of these cell surface polysaccharides from Klebsiella pneumoniae involves a multi-step process comprising phenol extraction, nuclease digestion, ultracentrifugation, and repeated ethanol extractions. In this study, we evaluated size exclusion chromatography for effectively eliminating nucleic acid contamination while purifying high molecular weight cell surface-associated polysaccharides. Post-initial extraction, the nucleic acid content remains significantly elevated, and kinetic analysis reveals that DNase I and RNase A digestion is neither economically viable nor effective for removing these contaminants. Employing an appropriate size exclusion resin removes over 99 % of nucleic acid contamination, as confirmed by nucleic acid content analysis and agarose gel electrophoresis. Purity and structural analysis using 1H 1D-NMR and 2D-NMR demonstrate that the cell surface-associated polysaccharide purified with this study is highly homogeneous and identified as antigenic O-polysaccharide. This approach streamlines the purification process by removing the need for nuclease digestion and additional ethanol precipitation steps.

60 APPLIED LIFE SCIENCES↗

Designer Metal–Organic Frameworks for Size–Exclusion–Based Hydrocarbon Separations: Progress and Challenges

The separation of hydrocarbons is of primary importance in the petrochemical industry but remains a challenging process. Hydrocarbon separations have traditionally relied predominantly on costly and energy intensive heat-driven procedures such as low temperature distillations. Adsorptive separation based on porous solids represents an alternative technology that is potentially more energy efficient for the separation of some hydrocarbons. Great efforts have been made recently not only on the development of adsorbents with optimal separation performance but also towards the subsequent implementation of adsorption-based separation technology. Emerging as a relatively new class of multifunctional porous materials, metal-organic frameworks hold substantial promise as adsorbents for highly efficient separation of hydrocarbons. This is because of their exceptional and intrinsic porosity tunability which enables size-exclusion based separations that render the highest possible separation selectivity. In this review, we highlight the recent advances in the development of MOFs for separation of selected groups of hydrocarbons, including methane/C2 hydrocarbons, normal alkanes, alkane isomers, alkane/alkene/alkyne, and C8 alkylaromatics, with a particular focus on separations based on size-exclusion mechanism. Insights into tailor-made structures, material design strategies, and structure-property relations will be elucidated. In addition, the existing challenges and possible future directions of this important research field will be discussed.

36 MATERIALS SCIENCE↗

A fast and sensitive size-exclusion chromatography method for plasma extracellular vesicle proteomic analysis

Extracellular vesicles (EVs) carry diverse biomolecules derived from their parental cells, making their components excellent biomarker candidates. However, purifying EVs is a major hurdle in biomarker discovery since current methods require large amounts of samples, are time-consuming and typically have poor reproducibility. Here we describe a simple, fast, and sensitive EV fractionation method using size exclusion chromatography (SEC) on a fast protein liquid chromatography (FPLC) system. Our method uses a Superose 6 Increase 5/150, which has a bed volume of 2.9 mL. The FPLC system and small column size enable reproducible separation of only 50 µL of human plasma in 15 min. To demonstrate the utility of our method, we used longitudinal samples from a group of individuals who underwent intense exercise. A total of 838 proteins were identified, of which, 261 were previously characterized as EV proteins, including classical markers, such as cluster of differentiation (CD)9 and CD81. Quantitative analysis showed low technical variability with correlation coefficients greater than 0.9 between replicates. The analysis captured differences in relevant EV proteins involved in response to physical activity. Our method enables fast and sensitive fractionation of plasma EVs with low variability, which will facilitate biomarker studies in large clinical cohorts.

59 BASIC BIOLOGICAL SCIENCES↗

Nano-fabricated size exclusion chromatograph

This poster describes the development of a nano-fabricated size exclusion chromatograph (nSEC) based on the principle that molecules traveling through a microcolumn containing nano-fabricated features will have characteristics elution times that directly correlate to molecular weight.

Nanofluidics microfluidics lab-on-a-chip↗

Structures of HIV-1 Neutralizing Antibody 10E8 Delineate the Mechanistic Basis of Its Multi-Peak Behavior on Size-Exclusion Chromatography

Antibody 10E8 is capable of effectively neutralizing HIV through its recognition of the membrane-proximal external region (MPER), and a suitably optimized version of 10E8 might have utility in HIV therapy and prophylaxis. However, 10E8 displays a three-peak profile on size-exclusion chromatography (SEC), complicating its manufacture. Here we show cis-trans conformational isomerization of the Tyr-Pro-Pro (YPP) motif in the heavy chain 3rd complementarity-determining region (CDR H3) of antibody 10E8 to be the mechanistic basis of its multipeak behavior. We observed 10E8 to undergo slow conformational isomerization and delineate a mechanistic explanation for effective comodifiers that were able to resolve its SEC heterogeneity and to allow an evaluation of the critical quality attribute of aggregation. We determined crystal structures of single and double alanine mutants of a key di-proline motif and of a light chain variant, revealing alternative conformations of the CDR H3. We also replicated both multi-peak and delayed SEC behavior with MPER-antibodies 4E10 and VRC42, by introducing a Tyr-Pro (YP) motif into their CDR H3s. Our results show how a conformationally dynamic CDR H3 can provide the requisite structural plasticity needed for a highly hydrophobic paratope to recognize its membrane-proximal epitope.

60 APPLIED LIFE SCIENCES↗

Size Exclusion Chromatography Studies of the Initial Self-Association Steps of Chicken Egg White Lysozyme Nucleation

Nucleation is one of the least understood aspects of crystallogenesis. In the case of macromolecule nucleation, this understanding is further hampered by uncertainty over what precisely is being discussed. We define the process of solute self-association (aggregation, oligomerization, interaction, clustering, etc.) whereby n-mers (n > or = 2) having a crystallographic or nascent crystallographic arrangement leading to the critical nucleus reversibly form in the solution, to be part of the nucleation process. This reversible self-association process is a fundamental part of the nucleation process, and occurs as a function of the solute concentration. In the case of chicken egg white lysozyme, a considerable body of experimental evidence leads us to the conclusion that it also forms the crystal growth units. Size exclusion chromatography is a simple and direct method for determining the equilibrium constants for the self-association process. A Pharmacia FPLC system was used to provide accurate solution flow rates. The column, injection valve, and sample loop were all mounted within a temperature-controlled chamber. Chromatographically re-purified lysozyme was first dialyzed against the column equilibration buffer, with injection onto the column after several hours pre-incubation at the running temperature. Preliminary experiments, were carried out using a Toyopearl HW-50F column (1 x 50cm), equilibrated with 0.1 M sodium acetate, 5% sodium chloride, pH 4.6, at 15C. Protein concentrations from 0.1 to 4 mg/ml were employed (C(sub sat) = 1.2 mg/ml). The data from several different protein preparations consistently shows a progressively decreasing elution volume with increasing protein concentration, indicating that reversible self-association is occurring. The dotted line indicates the monomeric lysozyme elution volume. However, lysozyme interacts with the column matrix in these experiments, which complicates data analysis.Accordingly, we are testing silica-based HPLC columns in an effort to eliminate this problem and substantially reduce the column volume and experimental run time. The results and data analysis from these and subsequent experiments will be presented.

Ewing, Felecia↗

Pore Aperture Control Toward Size‐Exclusion‐Based Hydrocarbon Separations

Abstract Metal–organic frameworks (MOFs) have been proposed as a promising material for non‐thermal chemical separations owing to their high structural diversity and tunability. Here, we report the synthesis of a zinc‐based MOF containing a three‐dimensional (3D) linker, bicyclo[2.2.2]octane‐1,4‐dicarboxylic acid, with high thermal stability towards the separation of hexane isomers. The incorporation of the 3D linker enhances the structural stability and provides well‐defined pore apertures/channels with sub‐Ångstrom precision. This precision allowed for the separation of similarly sized hexane isomers based on subtle differences in their kinetic diameters. Multi‐component liquid phase batch experiments confirmed the separation of hexanes mixture into linear, monobranched, and dibranched isomers. This work represents a significant milestone in the construction of stable Zn‐based MOFs and the incorporation of 3D linkers as a potential solution to challenging separations.

Lal, Bhajan↗

Pore Aperture Control Toward Size‐Exclusion‐Based Hydrocarbon Separations

Metal–organic frameworks (MOFs) have been proposed as a promising material for non-thermal chemical separations owing to their high structural diversity and tunability. Here, we report the synthesis of a zinc-based MOF containing a three-dimensional (3D) linker, bicyclo[2.2.2]octane-1,4-dicarboxylic acid, with high thermal stability towards the separation of hexane isomers. The incorporation of the 3D linker enhances the structural stability and provides well-defined pore apertures/channels with sub-Ångstrom precision. This precision allowed for the separation of similarly sized hexane isomers based on subtle differences in their kinetic diameters. Multi-component liquid phase batch experiments confirmed the separation of hexanes mixture into linear, monobranched, and dibranched isomers. This work represents a significant milestone in the construction of stable Zn-based MOFs and the incorporation of 3D linkers as a potential solution to challenging separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pillared Laminar Vermiculite Membranes with Tunable Monovalent and Multivalent Ion Selectivity

Effective membrane separation of Li + from Na + and Mg 2+ is crucial for lithium extraction from water yet challenging for conventional polymeric membranes. Two dimensional (2D) membranes with ordered laminar structures and tunable physicochemical properties offer distinctive ion-sieving capabilities promising for lithium extraction. Recently, phyllosilicates are introduced as abundant and cost-effective source materials for such membranes. However, their water instability and low inherent ion transport selectivity hinder practical applications. Herein, a new class of laminar membranes with excellent stability and tunable ion sieving is reported by incorporating inorganic alumina pillars into vermiculite interlayers. Crosslinking vermiculite flakes with alumina pillars significantly strengthens interlamellar interactions, resulting in robust water stability. Doping of Na + before the pillaring process reverses the membrane's surface charge, substantially boosting Li + separation from multivalent cations via electrostatic interactions. Lithium extraction is often complicated by the presence of co-existing monovalent cations (e.g., Na + ) at higher concentrations. Here, by introducing excess Na + into the membrane after the pillaring process, the separation of Li + from monovalent cations is enhanced through steric effects. This work realizes both monovalent/multivalent and monovalent/monovalent selective ion sieving with the same membrane platform. A separation mechanism is proposed based on Donnan exclusion and size exclusion, providing new insights for membrane design for resource recovery applications.

2D materials↗

Modifying the resolving cysteine affects the structure and hydrogen peroxide reactivity of peroxiredoxin 2

Peroxiredoxin 2 (Prdx2) is a thiol peroxidase with an active site Cys (C52) that reacts rapidly with H 2 O 2 and other peroxides. The sulfenic acid product condenses with the resolving Cys (C172) to form a disulfide which is recycled by thioredoxin or GSH via mixed disulfide intermediates or undergoes hyperoxidation to the sulfinic acid. C172 lies near the C terminus, outside the active site. It is not established whether structural changes in this region, such as mixed disulfide formation, affect H 2 O 2 reactivity. To investigate, we designed mutants to cause minimal (C172S) or substantial (C172D and C172W) structural disruption. Stopped flow kinetics and mass spectrometry showed that mutation to Ser had minimal effect on rates of oxidation and hyperoxidation, whereas Asp and Trp decreased both by 100-fold. To relate to structural changes, we solved the crystal structures of reduced WT and C172S Prdx2. The WT structure is highly similar to that of the published hyperoxidized form. C172S is closely related but more flexible and as demonstrated by size exclusion chromatography and analytical ultracentrifugation, a weaker decamer. Size exclusion chromatography and analytical ultracentrifugation showed that the C172D and C172W mutants are also weaker decamers than WT, and small-angle X-ray scattering analysis indicated greater flexibility with partially unstructured regions consistent with C-terminal unfolding. We propose that these structural changes around C172 negatively impact the active site geometry to decrease reactivity with H 2 O 2 . This is relevant for Prdx turnover as intermediate mixed disulfides with C172 would also be disruptive and could potentially react with peroxides before resolution is complete.

59 BASIC BIOLOGICAL SCIENCES↗