Search NASA⌕ Search

SEARCH · Search NASA

Results for “size sieving”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Centrifugal Size-Separation Sieve for Granular Materials

A centrifugal sieve and method utilizes centrifugal force in rapidly-rotated cylindrical or conical screens as the primary body force contributing to size segregation. Within the centrifugal acceleration field, vibration and/or shearing flows are induced to facilitate size segregation and eventual separation of the fines from the coarse material. Inside a rotating cylindrical or conical screen, a separately-rotated screw auger blade can be used to transport material along the rotating cylinder or conical wall and to induce shearing in the material.

Walton, Otis↗

Laser Diffraction Techniques Replace Sieving for Lunar Soil Particle Size Distribution Data

Sieving was used extensively until 1999 to determine the particle size distribution of lunar samples. This method is time-consuming, and requires more than a gram of material in order to obtain a result in which one may have confidence. This is demonstrated by the difference in geometric mean and median for samples measured by [1], in which a 14-gram sample produced a geometric mean of approx.52 micrometers, whereas two other samples of ~1.5 grams resulted in gave means of approx.63 and approx.69 micrometers. Sample allocations for sieving are typically much smaller than a gram, and many of the sample allocations received by our lab are 0.5 to 0.25 grams in mass. Basu [2] has described how the finest fraction of the soil is easily lost in the sieving process, and this effect is compounded when sample sizes are small.

Cooper, Bonnie L.↗

Survivability of Microbes in Mars Wind Blown Dust Environment

Although the probability of Earth microbes growing (dividing) in the Martian environment is extremely low, the probability of their survival on the Martian surface is unknown. During the course of landed missions to Mars terrestrial microbes may reach the surface of Mars via inadequately sterilized spacecraft landers, rovers, or through accidental impact of orbiters. This investigation studied the potential for Earth microbes to survive in the windblown dust on the surface of Mars. The rationale for the study comes from the fact that Mars regularly has huge dust storms that engulf the planet, shading the surface from solar UV radiation. These storms serve as a mechanism for global transfer of dust particles. If live organisms were to be transported to the surface of Mars they could be picked up with the dust during a dust storm and transported across the planet. Washed, dried spores of Bacillus subtilis strain HA 101 were aseptically mixed with sterile sieved (size range of 1-5microns) Mars soil standard (obtained from NASA Johnson Space Center, Houston, Texas, USA), or Fe-montmorillonite such that the number of microbes equals 5 x 10(exp 6)/g dry wt soil. The microbe soil mixture was placed in a spherical 8 L Mars simulation chamber equipped with a variable speed rotor, gas ports and an Oriel deuterium UV lamp emitting light of wave lengths 180-400 nm. The chamber was sealed, flushed with a simulated Martian atmosphere (96.9% CO2, 3% O2, 0.1% H2O), and the pressure brought to 10 torr. The lamp and rotor were switched on to begin the experiment. Periodically samples were collected from the chamber, and the numbers of microbial survivors g soil was determined using plate counts and the most probable number method (MPN). The data indicate that Bacillus subtilis spores dispersed with Mars analog soil in a Mars atmosphere (wind blown dust) survive exposure to 5.13 KJ m-2 UV radiation, suggesting that Mars wind blown dust has potential to the protect microbes from solar UV radiation.

Mancinelli, Rocco L.↗

High-Speed Transport of Fluid Drops and Solid Particles via Surface Acoustic Waves

A compact sampling tool mechanism that can operate at various temperatures, and transport and sieve particle sizes of powdered cuttings and soil grains with no moving parts, has been created using traveling surface acoustic waves (SAWs) that are emitted by an inter-digital transducer (IDT). The generated waves are driven at about 10 MHz, and it causes powder to move towards the IDT at high speed with different speeds for different sizes of particles, which enables these particles to be sieved. This design is based on the use of SAWs and their propelling effect on powder particles and fluids along the path of the waves. Generally, SAWs are elastic waves propagating in a shallow layer of about one wavelength beneath the surface of a solid substrate. To generate SAWs, a piezoelectric plate is used that is made of LiNbO3 crystal cut along the x-axis with rotation of 127.8 along the y-axis. On this plate are printed pairs of fingerlike electrodes in the form of a grating that are activated by subjecting the gap between the electrodes to electric field. This configuration of a surface wave transmitter is called IDT. The IDT that was used consists of 20 pairs of fingers with 0.4-mm spacing, a total length of 12.5 mm. The surface wave is produced by the nature of piezoelectric material to contract or expand when subjected to an electric field. Driving the IDT to generate wave at high amplitudes provides an actuation mechanism where the surface particles move elliptically, pulling powder particles on the surface toward the wavesource and pushing liquids in the opposite direction. This behavior allows the innovation to separate large particles and fluids that are mixed. Fluids are removed at speed (7.5 to 15 cm/s), enabling this innovation of acting as a bladeless wiper for raindrops. For the windshield design, the electrodes could be made transparent so that they do not disturb the driver or pilot. Multiple IDTs can be synchronized to transport water or powder over larger distances. To demonstrate the transporting action, a video camera was used to record the movement. The speed of particles was measured from the video images.

Bar-Cohen, Yoseph↗

Centrifugal Sieve for Gravity-Level-Independent Size Segregation of Granular Materials

Conventional size segregation or screening in batch mode, using stacked vibrated screens, is often a time-consuming process. Utilization of centrifugal force instead of gravity as the primary body force can significantly shorten the time to segregate feedstock into a set of different-sized fractions. Likewise, under reduced gravity or microgravity, a centrifugal sieve system would function as well as it does terrestrially. When vibratory and mechanical blade sieving screens designed for terrestrial conditions were tested under lunar gravity conditions, they did not function well. The centrifugal sieving design of this technology overcomes the issues that prevented sieves designed for terrestrial conditions from functioning under reduced gravity. These sieves feature a rotating outer (cylindrical or conical) screen wall, rotating fast enough for the centrifugal forces near the wall to hold granular material against the rotating screen. Conventional centrifugal sieves have a stationary screen and rapidly rotating blades that shear the granular solid near the stationary screen, and effect the sieving process assisted by the airflow inside the unit. The centrifugal sieves of this new design may (or may not) have an inner blade or blades, moving relative to the rotating wall screen. Some continuous flow embodiments would have no inner auger or blades, but achieve axial motion through vibration. In all cases, the shearing action is gentler than conventional centrifugal sieves, which have very high velocity differences between the stationary outer screen and the rapidly rotating blades. The new design does not depend on airflow in the sieving unit, so it will function just as well in vacuum as in air. One advantage of the innovation for batch sieving is that a batch-mode centrifugal sieve may accomplish the same sieving operation in much less time than a conventional stacked set of vibrated screens (which utilize gravity as the primary driving force for size separation). In continuous mode, the centrifugal sieves can provide steady streams of fine and coarse material separated from a mixed feedstock flow stream. The centrifugal sieves can be scaled to any desired size and/or mass flow rate. Thus, they could be made in sizes suitable for small robotic exploratory missions, or for semi-permanent processing of regolith for extraction of volatiles of minerals. An advantage of the continuous-mode system is that it can be made with absolutely no gravity flow components for feeding material into, or for extracting the separated size streams from, the centrifugal sieve. Thus, the system is capable of functioning in a true microgravity environment. Another advantage of the continuous-mode system is that some embodiments of the innovation have no internal blades or vanes, and thus, can be designed to handle a very wide range of feedstock sizes, including occasional very large oversized pieces, without jamming or seizing up.

Walton, Otis R.↗

Achromatic Emission Velocity Measurements in Luminous Flows

A new velocity measurement instrument for luminous flows was developed by Science Research Laboratory for NASA. The SIEVE (Segmented Image Emission VElocimeter) instrument uses broadband light emitted by the flow for the velocity measurement. This differs from other velocimetry techniques in that it does not depend on laser illumination and/or light scattering from particles in the flow. The SIEVE is a passive, non-intrusive diagnostic. By moving and adjusting the imaging optics, the SIEVE can provide three-dimensional mapping of a flow field and determine turbulence scale size. A SIEVE instrument was demonstrated on an illuminated rotating disk to evaluate instrument response and noise and on an oxy-acetylene torch to measure flame velocities. The luminous flow in rocket combustors and plumes is an ideal subject for the SIEVE velocity measurement technique.

Schneider, S. J.↗

Mechanism for Particle Transport and Size Sorting via Low-Frequency Vibrations

There is a need for effective sample handling tools to deliver and sort particles for analytical instruments that are planned for use in future NASA missions. Specifically, a need exists for a compact mechanism that allows transporting and sieving particle sizes of powdered cuttings and soil grains that may be acquired by sampling tools such as a robotic scoop or drill. The required tool needs to be low mass and compact to operate from such platforms as a lander or rover. This technology also would be applicable to sample handling when transporting samples to analyzers and sorting particles by size.

Sherrit, Stewart↗

Three-Body Abrasion Testing Using Lunar Dust Simulants to Evaluate Surface System Materials

Numerous unexpected operational issues relating to the abrasive nature of lunar dust, such as scratched visors and spacesuit pressure seal leaks, were encountered during the Apollo missions. To avoid reoccurrence of these unexpected detrimental equipment problems on future missions to the Moon, a series of two- and three-body abrasion tests were developed and conducted in order to begin rigorously characterizing the effect of lunar dust abrasiveness on candidate surface system materials. Two-body scratch tests were initially performed to examine fundamental interactions of a single particle on a flat surface. These simple and robust tests were used to establish standardized measurement techniques for quantifying controlled volumetric wear. Subsequent efforts described in the paper involved three-body abrasion testing designed to be more representative of actual lunar interactions. For these tests, a new tribotester was developed to expose samples to a variety of industrial abrasives and lunar simulants. The work discussed in this paper describes the three-body hardware setup consisting of a rotating rubber wheel that applies a load on a specimen as a loose abrasive is fed into the system. The test methodology is based on ASTM International (ASTM) B611, except it does not mix water with the abrasive. All tests were run under identical conditions. Abraded material specimens included poly(methyl methacrylate) (PMMA), hardened 1045 steel, 6061-T6 aluminum (Al) and 1018 steel. Abrasives included lunar mare simulant JSC- 1A-F (nominal size distribution), sieved JSC-1A-F (<25 m particle diameter), lunar highland simulant NU-LHT-2M, alumina (average diameter of 50 m used per ASTM G76), and silica (50/70 mesh used per ASTM G65). The measured mass loss from each specimen was converted using standard densities to determine total wear volume in cm3. Abrasion was dominated by the alumina and the simulants were only similar to the silica (i.e., sand) on the softer materials of aluminum and PMMA. The nominal JSC- 1A-F consistently showed more abrasion wear than the sieved version of the simulant. The lunar dust displayed abrasivity to all of the test materials, which are likely to be used in lunar landing equipment. Based on this test experience and pilot results obtained, recommendations are made for systematic abrasion testing of candidate materials intended for use in lunar exploration systems and in other environments with similar dust challenges.

Kobrick, Ryan L.↗

The Development of an Edible Peanut Protein Film

The peanut is one of the crops chosen for use in NASA's Advanced Life Support Program (ALS). The peanut is a source of both oil and protein. After oil is extracted from the peanut, a protein rich flour remains. An edible peanut protein film is one use for this flour. Two types of film are developed for this study, one set of film contains 10% fat while the other set contains no fat. For film without fat the defatting of the peanut by the Soxhlet method is the first step in the manufacturing process of the film. Secondly, the protein is precipitated at its isoelectric point (pH 4.5) and centrifuged to separate the protein from the non-protein. After freeze-drying the protein it is milled in a ceramic ball mill to decrease particle size and sifted through a series of sieves to determine particle size distribution. Those particles retained on the 100 mesh sieves are utilized for film formation. Larger particles are re-ground and sifted. Five grams of protein is mixed with 50 mL of distilled water, 70 mL of 80% ethanol, 15 mL of 6N ammonium hydroxide and a plasticizer. This mixture is heated for 30 minutes until the temperature reaches 70 C. The mixture is then poured onto a level Teflon coated glass surface. After allowing the film to form overnight under a ventilation hood, it is manually removed from the plate. The processes and methods adopted have created flexible films of uniform thickness that are free of air bubbles. Thickness of films made from defatted peanut protein and partially defatted peanut protein were 0.10 Lm and 0.13 Lm respectively. Films with natural peanut fat are approximately three times as flexible and almost four times as strong as the films made without fat. Further research will be performed to evaluate its mechanical properties. This paper will greatly contribute to food preservation and waste management. Potential applications of this film are edible/biodegradable containers, wrapping for food preservation (against water, oxygen and oil), storage packets for seasonings or other ingredients and encapsulation for pharmaceutical use.

Patrick, N.↗

Effect of osteoblastic culture conditions on the structure of poly(DL-lactic-co-glycolic acid) foam scaffolds

Poly(DL-lactic-co-glycolic acid) (PLGA) foams are an osteoconductive support that holds promise for the development of bone tissue in vitro and implantation into orthopedic defects. Because it is desirable that foams maintain their shape and size, we examined a variety of foams cultured in vitro with osteoblastic cells. Foams were prepared with different porosities and pore sizes by the method of solvent casting/porogen leaching using 80, 85, and 90 wt% NaCl sieved with particle sizes of 150-300 and 300-500 microm and characterized by mercury intrusion porosimetry. Foams seeded with cells were found to have volumes after 7 days in static culture that decreased with increasing porosity: the least porous exhibited no change in volume while the most porous foams decreased by 39 +/- 10%. In addition, a correlation was observed between decreasing foam volume after 7 days in culture and decreasing internal surface area of the foams prior to seeding. Furthermore, foams prepared with the 300-500 microm porogen had lower porosities, greater mean wall thicknesses between adjacent pores, and larger volumes after 7 days in culture than those prepared with the smaller porogen. Two culture conditions for maintaining cells, static and agitated (in a rotary vessel), were found to have similar influences on foam size, cell density, and osteoblastic function for 7 and 14 days in culture. Finally, we examined unseeded foams in aqueous solutions of pH 3.0, 5.0, and 7.4 and found no significant decrease in foam size with degradation. This study demonstrates that adherent osteoblastic cells may collapse very porous PLGA foams prepared by solvent casting/particulate leaching: a potentially undesirable property for repair of orthopedic defects.

NASA Program Fundamental Space Biology↗

Apollo 16: Core 60004 - Preliminary study of less than 1 mm fines

The article studies the possible variation of mineralogy as a function of both grain size and depth within the core of less than 1 mm fines, for the core section 60004 from Apollo 16. Twelve samples of the fines were dry sieved. The grain size analysis showed a bimodal distribution for all samples, indicating a competing process of grain size degeneration and agglutinate formation. Approximately 99% of the minerals in the samples examined consisted of plagioclase feldspar, pyroxene and olivine, with plagioclase the dominant phase. The various minerals were analyzed, using standard electron microprobe techniques, as a function of size range for each sample, and the representative analyses are presented. Several types of glass were also analyzed, ranging in color from orange through yellow and green to colorless. The investigation of the chemical variations of mineral and lithic clasts from the top and the bottom of the core suggests that although minor variations are present, the regolith was derived from fairly homogeneous sources.

Meyer, H. O. A.↗

Thermal conductivity measurements of particulate materials under Martian conditions

The mean particle diameter of surficial units on Mars has been approximated by applying thermal inertia determinations from the Mariner 9 Infrared Radiometer and the Viking Infrared Thermal Mapper data together with thermal conductivity measurement. Several studies have used this approximation to characterize surficial units and infer their nature and possible origin. Such interpretations are possible because previous measurements of the thermal conductivity of particulate materials have shown that particle size significantly affects thermal conductivity under martian atmospheric pressures. The transfer of thermal energy due to collisions of gas molecules is the predominant mechanism of thermal conductivity in porous systems for gas pressures above about 0.01 torr. At martian atmospheric pressures the mean free path of the gas molecules becomes greater than the effective distance over which conduction takes place between the particles. Gas particles are then more likely to collide with the solid particles than they are with each other. The average heat transfer distance between particles, which is related to particle size, shape and packing, thus determines how fast heat will flow through a particulate material.The derived one-to-one correspondence of thermal inertia to mean particle diameter implies a certain homogeneity in the materials analyzed. Yet the samples used were often characterized by fairly wide ranges of particle sizes with little information about the possible distribution of sizes within those ranges. Interpretation of thermal inertia data is further limited by the lack of data on other effects on the interparticle spacing relative to particle size, such as particle shape, bimodal or polymodal mixtures of grain sizes and formation of salt cements between grains. To address these limitations and to provide a more comprehensive set of thermal conductivities vs. particle size a linear heat source apparatus, similar to that of Cremers, was assembled to provide a means of measuring the thermal conductivity of particulate samples. In order to concentrate on the dependence of the thermal conductivity on particle size, initial runs will use spherical glass beads that are precision sieved into relatively small size ranges and thoroughly washed.

Presley, M. A.↗

Electrostatic Beneficiation of Lunar Simulant

Electrostatic beneficiation of lunar regolith is a method allowing refinement of specific minerals in the material for processing on the moon. The use of tribocharging the regolith prior to separation was investigated on the lunar simulant MLS-I by passing the dust through static mixers constructed from different materials; aluminum, copper, stainless steel, and polytetrafluoroethylene (PTFE). The amount of charge acquired by the simulant was dependent upon the difference in the work function of the dust and the charging material. XPS and SEM were used to characterize the simulant after it was sieved into five size fractions (> 100 pm, 75-100 pm, 50- 75 pm, 50-25 pm, and < 25 pm), where very little difference in surface composition was observed between the sizes. Samples of the smallest (< 25 pm) and largest (> 100 pm) size fractions were beneficiated through a charge separator using the aluminum (charged the simulant negatively) and PTFE (charged positively) mixers. The mass fractions of the separated simulant revealed that for the larger particle size, significant unipolar charging was observed for both mixers, whereas for the smaller particle sizes, more bipolar charging was observed, probably due to the finer simulant adhering to the inside of the mixers shielding the dust from the charging material. Subsequent XPS analysis of the beneficiated fractions showed the larger particle size fraction having some species differentiation, but very little difference for the smaller.size. Although MLS-1 was made to have similar chemistry to actual lunar dust, its mineralogy is quite different. On-going experiments are using NASA JSC-1 lunar simulant. A vacuum chamber has been constructed, and future experiments are planned in a simulated lunar environment.

Trigwell, Steve↗

Filter Bed of Packed Spheres

Spheres sized and treated for desired sieve properties. Filter constructed from densely packed spheres restrained by screens. Hollow gas-filled plastic or metal spheres normally used. Manufactured within one percent or better diameter tolerance. Normally, all spheres in filter of same nominal diameter. Filter used as sieve to pass only particles smaller than given size or to retain particles larger than that size. Options available under filter concept make it easy to design for specific applications.

Elleman, D. D.↗

Surface-Correlated Nanophase Iron Metal in Lunar Soils: Petrography and Space Weathering Effects

Space weathering is a term used to include all of the processes that act on material exposed at the surface of a planetary or small body. In the case of the Moon, it includes a variety of processes that formed the lunar regolith, caused the maturation of lunar soils, and formed patina on rock surfaces. The processes include micrometeorite impact and reworking, implantation of solar wind and flare particles, radiation damage and chemical effects from solar particles and cosmic rays, interactions with the lunar atmosphere, and sputtering erosion and deposition. Space weathering effects collectively result in a reddened continuum slope, lowered albedo, and attenuated absorption features in reflectance spectra of lunar soils as compared to finely comminuted rocks from the same Apollo sites. Understanding these effects is critical in order to fully integrate the lunar sample collection with remotely sensed data from recent robotic missions (e.g., Lunar Prospector, Clementine, Galileo). Our objective is to determine the origin of space weathering effects in lunar soils through combined electron microscopy and microspectrophotometry techniques applied to individual soil particles from <20 pm size factions (dry-sieved) of mature lunar soils. It has been demonstrated that it is the finest size fraction (<25 pm) of lunar soils that dominates the optical properties of the bulk soils.

Keller, Lindsay P.↗

Using X-Ray Computed Tomography to Catalog Rock Fragments in Apollo Drive Tube 73002

Overview: The Apollo missions collected 382 kg of rock, regolith, and core samples from six locations on the nearside of the Moon. Approximately 84% by mass of the Apollo collection remains in pristine condition within the curation facility at Johnson Space Center (i.e., never allocated, continuously stored in dry-N2 purged cabinets, exposure history restricted to Teflon, stainless steel, and Al-metal). Although most Apollo samples have been well characterized, there are several types of samples that have remained wholly or largely unstudied since their return, and/or that have been cu-rated under special conditions, e.g., frozen samples, samples stored in He-purged environment, and previously unopened drive tubes. NASA solicited proposals for the Apollo Next Generation Sample Analysis Pro-gram (ANGSA), and 9 teams were selected to study a subset of the unopened and frozen samples [1]. The first sample opened as part of the ANGSA pro-gram was drive tube 73002. This was originally a ~30 cm long, 4 cm diameter drive tube collected on a land-slide deposit near Lara Crater at the Apollo 17 landing site. It was part of a ~60 cm long double drive tube collected, and the bottom half of the tube (73001) was sealed under vacuum on the Moon [2]. Prior to opening sample 73002, the sample was imaged with a high resolution X-ray Computed Tomography (XCT) scan of the entire tube [3], which provided invaluable information during the dissection process [4]. In addition to the pre-dissection XCT scans, individual >4 mm particles were separated from the 73002 regolith during processing and scanned at high resolution by XCT. Here we pre-sent the initial lithologic classification of 134 individual >4 mm rock fragments separated from the 73002 core during the dissection process. Methodology: Drive tube 73002 was manually dissected in 0.5 cm depth intervals in three passes (Fig. 1) [4,5]. Each interval from pass 1 and 2 was sieved to <1 mm and >1 mm size fractions, and >1 mm particles were further manually subdivided into 1-2, 2-4, 4-10, and >10 mm size fractions. Pass 3 was not sieved, but >10 mm clasts were separated manually. Each 4-10 mm and >10 mm fragment was individually weighed, triply bagged in Teflon, and scanned by XCT. There are 60 rock fragments in Pass 1, 64 rock fragments in Pass 2 (from the 4-10 mm and >10 mm size fractions), and 8 rock fragments from Pass 3 (>10 mm size fraction). Each individually bagged rock fragment was scanned using the 180 kV nano-focus transmission source on the Nikon XTH 320 XCT system at NASA Johnson Space Center [6]. Scanning conditions varied considerably for individual particles, in large part be-cause of the large variation in size (0.008-19.623 g). All scans fell within the following range of scan conditions: 2.8-20.6 um voxel size; 90-155 kV voltage; 18-39 uA current; 1891-3141 projections; and 902-2000 slices. Results and Discussion: The 132 rock fragments from sample 73002 fall into the following general cat-gories: agglutinates (n = 6); basalts (13); impact melts (5); impact melt breccias (IMB; 42); regolith breccias (62); and soil breccias (4); see Figure 2 for representative examples of each lithology. Within most of these broad lithologic groups are recognizable subgroups. For example, a significant portion of regolith breccia fragments contain some agglutinate-like glass (n = 9) or are dilithologic (7) because they contain a single large clast (~50% or more by volume). Subgroups can be based on similarities to previously identified lunar lithologies, such as high-Ti basalts (9) and VLT basalts (4; Fig. 3), or based on commonly seen features within the fragments, such as poikilitic ilmenite IMB (10), ilmenite-lath IMB (12), or vesicular IMB (11) “groups”. Particles in the same “group” are not necessarily intended to be genetically related, but rather identify particles that are similar and that follow-up studies can classify in more detail [7]. Conclusion: Identification of lithologies based on XCT is a powerful tool, but a more absolute classification will sometimes require additional textural information from thin sections (e.g., glassy-matrix regolith vs. impact-melt vs. granulitic breccia) or quantitative mineral compositions (e.g., basalt vs. monomict breccia).

R A Zeigler↗

Provenance of KREEP and the exotic component - Elemental and isotopic studies of grain size fractions in lunar soils

Sieve fraction analyses of lunar soils reveal the presence of a fine-grained exotic component enriched in K, Rb, Sr, Ba, and in radiogenic Sr in all soils. The probable source of this exotic component is the areas of high-surficial radioactivity observed by orbital gamma ray spectrometry, such as those at Fra Mauro and Archimedes. If the exotic component is fine-grained KREEP, the origin and distribution of KREEP fragments in the soils are identified. It is suggested that the exotic component represents trace element enriched material located at some depth in the Imbrium area which was surficially deposited during Imbrium excavation.

Evensen, N. M.↗

A Study of Particle Size Metrics Using Non-Spherical Feedstock for Metal Additive Manufacturing

The goal of this work was to determine which standard particle size metric derived from optical analysis most closely approximates the sieved weight percent of irregularly shaped powder intended to be used for directed energy deposition. In this investigation, equivalent circle diameter, maximum diameter, minimum diameter, and perimeter are used as metrics to “virtually sieve” the particles in samples of irregularly shaped powder into the following particle size bins: <45 µm, 45 µm - 150 µm, and >150 µm. The percentage in the 45 µm - 150 µm bin is then compared to the weight percent of the powder mechanically sieved into this size range. The absolute difference between the virtually sieved percentage and the mechanically sieved percentage was assessed for 81 samples of mechanically-generated stainless steel 316L powder all produced under different processing conditions in an oscillation ball mill. This difference was found to be on average, the least with the minimum diameter assessed as an area percentage, followed by the equivalent diameter assessed as an area percentage, and then the maximum diameter assessed as a percentage of the total number of particles ranked third. These findings may be used by powder production process engineers and quality assurance personnel to assist in process control as more diverse additive manufacturing feedstocks become utilized.

Marcus Jackson↗