Search NASA⌕ Search

SEARCH · Search NASA

Results for “slice sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Estane Molecular Weight Analysis in PBX 9501 Samples; Slice 'N Dice Study

T Division is creating a model of aging in PBX 9501 that will benefit from molecular weight mapping of hemispherical charges (“hemi’s”) that have been in the stockpile. Two hemi’s were prepared at Pantex by machining out sections and then machining those sections into cubes, which is why the project is referred to as a “Slice ‘N Dice” study. Two sections were cut from each hemi. One section was used for density mapping and the other was for molecular weight analysis. The molecular weight section pieces were cut so that both Pantex and LANL would be able to analyze cubes from approximately the same areas in order to compare results. Pantex analyzed all of their samples earlier in 2011. LANL’s Slice ‘N Dice samples were received in February of 2012 where they were inventoried, weighed and prepared by WX-7 and analyzed by both WX-7 and MST-7.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of the α -decay half-life of Po 210 based on film and slice bismuth samples at room temperature

For this research, the α decay rate of 210 Po was measured in a film sample ( 210 Po@Bi 2 O 3 ) and a slice sample ( 210 Po@Bi metal), respectively. The former was used as a reference sample. The half-lives of 210 Po@Bi 2 O 3 and 210 Po@Bi metal environments were observed to be (138.40 ± 0.21 d) and (138.87 ± 0.87 d) at room temperature, respectively. It was found that the half-life of 210 Po is consistent with international recommendations within the uncertainty limits, and we did not find any deviation of the α decay rate of 210 Po between film sample ( 210 Po@Bi 2 O 3 ) and slice sample ( 210 Po@Bi metal).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TH-EF-BRA-08: A Novel Technique for Estimating Volumetric Cine MRI (VC-MRI) From Multi-Slice Sparsely Sampled Cine Images Using Motion Modeling and Free Form Deformation

Purpose: To develop a technique to estimate on-board VC-MRI using multi-slice sparsely-sampled cine images, patient prior 4D-MRI, motion-modeling and free-form deformation for real-time 3D target verification of lung radiotherapy. Methods: A previous method has been developed to generate on-board VC-MRI by deforming prior MRI images based on a motion model(MM) extracted from prior 4D-MRI and a single-slice on-board 2D-cine image. In this study, free-form deformation(FD) was introduced to correct for errors in the MM when large anatomical changes exist. Multiple-slice sparsely-sampled on-board 2D-cine images located within the target are used to improve both the estimation accuracy and temporal resolution of VC-MRI. The on-board 2D-cine MRIs are acquired at 20–30frames/s by sampling only 10% of the k-space on Cartesian grid, with 85% of that taken at the central k-space. The method was evaluated using XCAT(computerized patient model) simulation of lung cancer patients with various anatomical and respirational changes from prior 4D-MRI to onboard volume. The accuracy was evaluated using Volume-Percent-Difference(VPD) and Center-of-Mass-Shift(COMS) of the estimated tumor volume. Effects of region-of-interest(ROI) selection, 2D-cine slice orientation, slice number and slice location on the estimation accuracy were evaluated. Results: VCMRI estimated using 10 sparsely-sampled sagittal 2D-cine MRIs achieved VPD/COMS of 9.07±3.54%/0.45±0.53mm among all scenarios based on estimation with ROI-MM-ROI-FD. The FD optimization improved estimation significantly for scenarios with anatomical changes. Using ROI-FD achieved better estimation than global-FD. Changing the multi-slice orientation to axial, coronal, and axial/sagittal orthogonal reduced the accuracy of VCMRI to VPD/COMS of 19.47±15.74%/1.57±2.54mm, 20.70±9.97%/2.34±0.92mm, and 16.02±13.79%/0.60±0.82mm, respectively. Reducing the number of cines to 8 enhanced temporal resolution of VC-MRI by 25% while maintaining the estimation accuracy. Estimation using slices sampled uniformly through the tumor achieved better accuracy than slices sampled non-uniformly. Conclusions: Preliminary studies showed that it is feasible to generate VC-MRI from multi-slice sparsely-sampled 2D-cine images for real-time 3D-target verification. This work was supported by the National Institutes of Health under Grant No. R01-CA184173 and a research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

An interoperable implementation of collective‐variable based enhanced sampling methods in extended phase space within the OpenMM package

Collective variable (CV)-based enhanced sampling techniques are widely used today for accelerating barrier-crossing events in molecular simulations. A class of these methods, which includes temperature accelerated molecular dynamics (TAMD)/driven-adiabatic free energy dynamics (d-AFED), unified free energy dynamics (UFED), and temperature accelerated sliced sampling (TASS), uses an extended variable formalism to achieve quick exploration of conformational space. These techniques are powerful, as they enhance the sampling of a large number of CVs simultaneously compared to other techniques. Extended variables are kept at a much higher temperature than the physical temperature by ensuring adiabatic separation between the extended and physical subsystems and employing rigorous thermostatting. Here, in this work, we present a computational platform to perform extended phase space enhanced sampling simulations using the open-source molecular dynamics engine OpenMM. The implementation allows users to have interoperability of sampling techniques, as well as employ state-of-the-art thermostats and multiple time-stepping. This work also presents protocols for determining the critical parameters and procedures for reconstructing high-dimensional free energy surfaces. As a demonstration, we present simulation results on the high dimensional conformational landscapes of the alanine tripeptide in vacuo, tetra-N-methylglycine (tetra-sarcosine) peptoid in implicit solvent, and the Trp-cage mini protein in explicit water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of early hydration temperature on hydration product and strength development of magnesium phosphate cement (MPC)

This paper investigates the effect of early hydration temperatures on hydration products and strength development of magnesium phosphate cement (MPC). MPC paste specimens with borate contents of 3%, 6%, 9% and 12% are prepared and cured in different air temperatures and in the adiabatic condition. The internal hydration temperatures are measured by pre-embedded temperature probes. MPC samples with different hydration temperatures are also obtained by using thin slice samples. The hydration products in MPC samples with different hydration temperatures are analyzed by X-ray diffractometer (XRD) and scanning electron microscope (SEM) and the strength development is also measured. The results show that NH{sub 4}MgPO{sub 4}·6H{sub 2}O is the major hydration product and beneficial to strength development of MPC at hydration temperature below 70 °C. NH{sub 4}MgPO{sub 4}·H{sub 2}O is another major product, which significantly decreases the strength, when the temperature is higher than a critical temperature between 70 °C and 75 °C. NH{sub 4}MgPO{sub 4}·H{sub 2}O can directly form in the MPC paste, and comes from the decomposition of NH{sub 4}MgPO{sub 4}·6H{sub 2}O when the temperature is above 75 °C. With temperature elevation and duration extension, NH{sub 4}MgPO{sub 4}·6H{sub 2}O decomposes rapidly, and even entirely when the temperature is above 100 °C. The borate content has no effect on the types of major hydration products and the critical temperature.

36 MATERIALS SCIENCE↗

Imaging of cochlear tissue with a grating interferometer and hard X-rays

This article addresses an important current development in medical and biological imaging: the possibility of imaging soft tissue at resolutions in the micron range using hard X-rays. Challenging environments, including the cochlea, require the imaging of soft tissue structure surrounded by bone. We demonstrate that cochlear soft tissue structures can be imaged with hard X-ray phase contrast. Furthermore, we show that only a thin slice of the tissue is required to introduce a large phase shift. It is likely that the phase contrast image of the soft tissue structures is sufficient to image the structures even if surrounded by bone. For the present set of experiments, structures with low-absorption contrast have been visualized using in-line phase contrast imaging and a grating interferometer. The experiments have been performed at the Advanced Photon Source at Argonne National Laboratories, a third generation source of synchrotron radiation. The source provides highly coherent X-ray radiation with high-photon flux (>10{sup 12} photons/s) at high-photon energies (5-70 keV). Radiographic and light microscopy images of the gerbil cochlear slice samples were compared. It has been determined that a 20-{micro}m thick tissue slice induces a phase shift between 1/3{pi} and 2/3{pi}.

43 PARTICLE ACCELERATORS↗

X-Ray Tomographic Reconstruction

Tomographic scans have revolutionized imaging techniques used in medical and biological research by resolving individual sample slices instead of several superimposed images that are obtained from regular x-ray scans. X-Ray fluorescence computed tomography, a more specific tomography technique, bombards the sample with synchrotron x-rays and detects the fluorescent photons emitted from the sample. However, since x-rays are attenuated as they pass through the sample, tomographic scans often produce images with erroneous low densities in areas where the x-rays have already passed through most of the sample. To correct for this and correctly reconstruct the data in order to obtain the most accurate images, a program employing iterative methods based on the inverse Radon transform was written. Applying this reconstruction method to a tomographic image recovered some of the lost densities, providing a more accurate image from which element concentrations and internal structure can be determined.

Schmittberger, Bonnie↗

Synchrotron X-ray topographic study on nature of threading mixed dislocations in 4H–SiC crystals grown by PVT method

Synchrotron X-ray Topography is a powerful technique to study defects structures particularly dislocation configurations in single crystals. Complementing this technique with geometrical and contrast analysis can enhance the efficiency of quantitatively characterizing defects. In this study, the use of Synchrotron White Beam X-ray Topography (SWBXT) to determine the line directions of threading dislocations in 4H–SiC axial slices (sample cut parallel to the growth axis from the boule) is demonstrated. This technique is based on the fact that the projected line directions of dislocations on different reflections are different. Another technique also discussed is the determination of the absolute Burgers vectors of threading mixed dislocations (TMDs) using Synchrotron Monochromatic Beam X-ray Topography (SMBXT). This technique utilizes the fact that the contrast from TMDs varies on SMBXT images as their Burgers vectors change. By comparing observed contrast with the contrast from threading dislocations provided by Ray Tracing Simulations, the Burgers vectors can be determined. Thereafter the distribution of TMDs with different Burgers vectors across the wafer is mapped and investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of dislocation configurations in SiC crystals through X-ray topography aided by ray tracing simulations

Silicon carbide as a wide bandgap semiconductor is of great research interest for its widespread deployment in a range of electronic and optoelectronic devices, particularly in power electronics. However, defects in silicon carbide crystals are still major concerns that is hampering the development of high-performance devices. X-ray topography, particularly using the synchrotron beam has been instrumental in characterizing and analyzing defect configurations in silicon carbide crystals to optimize crystal growth as well as understand the effect of defects on device performance. Here, in recent years, the use of ray-tracing simulation technique based on the orientation contrast mechanism to simulate contrast of defects observed on actual X-ray topographs has proven to be an effective approach to investigate the nature of crystallographic defects in various semiconductors. This review discusses the principle of ray-tracing simulation and its application and modifications to incorporate the effects of surface relaxation and photoelectric absorption to better simulate different dislocations observed in 4H–SiC as well as 6H–SiC crystals of various orientations. The adaptation to weak beam topography and plane wave topography is also discussed. The application of ray-tracing simulation in dislocation characterization of silicon carbide of different polytypes is systematically reviewed including different types of dislocations observed in both off-axis wafers and axial-sliced samples through synchrotron X-ray topography under various beam conditions, recording geometries and reflections. The result of ray-tracing simulation is further utilized in other studies including the investigation of effective penetration depth of all types of dislocations lying on the basal plane on grazing-incidence X-ray topography.

Engineering↗

SHOCK INITIATION EXPERIMENTS ON THE TATB BASED EXPLOSIVE RX-03-GO WITH IGNITION AND GROWTH MODELING

Shock initiation experiments on the TATB based explosive RX-03-GO (92.5% TATB, 7.5% Cytop A by weight) were performed to obtain in-situ pressure gauge data, characterize the run-distance-to-detonation behavior, and calculate Ignition and Growth modeling parameters. A 101 mm diameter propellant driven gas gun was utilized to initiate the explosive sample with manganin piezoresistive pressure gauge packages placed between sample slices. The RX-03-GO formulation utilized is similar to that of LX-17 (92.5% TATB, 7.5% Kel-f by weight) with the notable differences of a new binder material and TATB that has been dissolved and recrystallized in order to improve the purity and morphology. The shock sensitivity will be compared with that of prior data on LX-17 and other TATB formulations. Ignition and Growth modeling parameters were obtained with a reasonable fit to the experimental data.

36 MATERIALS SCIENCE↗

Robust sampling for weak lensing and clustering analyses with the Dark Energy Survey

Recent cosmological analyses rely on the ability to accurately sample from high-dimensional posterior distributions. A variety of algorithms have been applied in the field, but justification of the particular sampler choice and settings is often lacking. Here, we investigate three such samplers to motivate and validate the algorithm and settings used for the Dark Energy Survey (DES) analyses of the first 3 yr (Y3) of data from combined measurements of weak lensing and galaxy clustering. We employ the full DES Year 1 likelihood alongside a much faster approximate likelihood, which enables us to assess the outcomes from each sampler choice and demonstrate the robustness of our full results. We find that the ellipsoidal nested sampling algorithm multinest reports inconsistent estimates of the Bayesian evidence and somewhat narrower parameter credible intervals than the sliced nested sampling implemented in polychord. We compare the findings from multinest and polychord with parameter inference from the Metropolis–Hastings algorithm, finding good agreement. We determine that polychord provides a good balance of speed and robustness for posterior and evidence estimation, and recommend different settings for testing purposes and final chains for analyses with DES Y3 data. Our methodology can readily be reproduced to obtain suitable sampler settings for future surveys.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diamond as a solid state micro-fission chamber for thermal neutron detection at the VR-1 research reactor

Diamond exhibits a combination of properties which makes it attractive for neutron detection in hostile conditions. In the particular case of detection in a nuclear reactor, it is resilient to radiation, exhibits a natural low sensitivity to gamma rays, and its small size (as compared with that of gas ionisation chambers) enables fluency monitoring with a high position resolution. We report here on the use of synthetic CVD diamond as a solid state micro-fission chamber with U-235 converting material for in-core thermal neutron monitoring. Two types of thin diamond detectors were developed for this application. The first type of detector is fabricated using thin diamond membrane obtained by etching low-cost commercially available single crystal CVD intrinsic diamond, so called 'optical grade' material. Starting from a few hundred of micrometre thick samples, the sample is sliced with a laser and then plasma etched down to a few tenths of micrometre. Here we report the result obtained with a 17 μm thick device. The detection surface of this detector is equal to 1 mm{sup 2}. Detectors with surfaces up to 1 cm{sup 2} can be fabricated with this technique. The second type of detector is fabricated by growing successively two thin films of diamond, by the microwave enhanced chemical vapour deposition technique, on HPHT single crystal diamond. A first, a film of boron doped (p+) single crystal diamond, a few microns thick, is deposited. Then a second film of intrinsic diamond with a thickness of a few tens of microns is deposited. This results in a P doped, Intrinsic, Metal structure (PIM) structure in which the intrinsic volume id the active part of the detector. Here we report the results obtained with a 20 μm thick intrinsic whose detection surface is equal to 0.5 mm{sup 2}, with the possibility to enlarge the surface of the detector up to 1 cm{sup 2}. These two types of detector were tested at the VR-1 research reactor at the Czech Technical University in Prague. The Training Reactor VR-1 is a pool type (light water) reactor based on UO{sub 2} low enriched uranium. It has a nominal power of 1 kW, and can be operated for a short period up to 5 kW. The arrangement of the reactor pool reactor facilitates access to the core, setting and removal of various experimental samples and detectors, and safe and easy handling of fuel assemblies. The reactor is equipped with two horizontal channels (radial and tangential) and 10 vertical channels, of varying diameters, which can be loaded into various core positions, and one pneumatic transfer system. It is also equipped with several specifically designed educational instrumentation systems that can be used to supply complementary measurements and characterization around the reactor. The reactor is operated by the Department of Nuclear Reactors of the Faculty of Nuclear Sciences and Physical Engineering of the Czech Technical University in Prague. The two detectors were placed in-core through one of the vertical insertion channel. They were coupled to remote placed (5 m BNC cable) classical nuclear charge sensitive electronics. Detection properties of both sensors, including: pulse height spectra of U-235 fission fragments (response linearity with neutron flux, count rate, gamma background, were evaluated varying the power of the reactor from 0.005 W to 500 W. The evolution of the counting rate of the thinned optical grade detector as a function of counting rate of a gas ionization chamber used currently for reactor monitoring shows the very good linearity of the detector over the 5 decades. Similar results were obtained with the PIM detector. Additionally fast transient current signals of the detectors were recorded on a digital storage oscilloscope (DSO) using broad-band amplifier and with a simple bias-T, showing potential use of such sensors for neutron counting with no need of an amplification stage, since non-amplified signals from fission fragments exceeded 4 mV in amplitude. Therefore, one can think of simple neutron counting system by feeding diamond detectors signals directly to the low threshold discriminators. The results obtained on the VR1 will be described and discussed in detail in the paper and associated presentation. The results demonstrate that diamond micro-fission chambers can be used for in-core neutron monitoring, where robust, simple and compact devices are required.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of X-ray Microscopy at IPOE

In order to meet the different requirements of applications in synchrotron radiation and plasma diagnosis in China, focusing and imaging optics based on Kirkpatrick-Baez (KB) mirrors, compound refractive lenses (CRLs), and multilayer Laue lenses (MLLs) were studied in our lab. A one-dimensional KB microscope using mirrors with a dual-periodic multilayer coating was developed. The multilayer mirror can reflect both 4.75 keV (Ti K-line) and 8.05 keV (Cu K-line) simultaneously, which makes alignment easier. For hard x-ray microscopy, CRL was studied. Using a SU-8 resist planar parabolic CRL, a focal line of 28.8-{mu}m width was obtained. To focus hard x-rays to nanometer levels efficiently, an MLL was fabricated using a WSi{sub 2}/Si multilayer. The MLL consists of 324 alternating WSi{sub 2} and Si layers with a total thickness of 7.9 {mu}m. (Recently, a much thicker multilayer has been deposited with a layer number of n = 1582 and a total thickness of 27 {mu}m.) After deposition, the sample was sliced and polished into an approximate ideal aspect ratio (depth of the zone plate to outmost layer thickness); the measured results show an intact structure remains, and the surface roughness of the cross section is about 0.4 nm after grinding and polishing processes.

43 PARTICLE ACCELERATORS↗

EPICS Controlled Collimator for Controlling Beam Sizes in HIPPO

Controlling the beam spot size and shape in a diffraction experiment determines the probed sample volume. The HIPPO - High-Pressure-Preferred Orientation– neutron time-offlight diffractometer is located at the Lujan Neutron Scattering Center in Los Alamos National Laboratories. HIPPO characterizes microstructural parameters, such as phase composition, strains, grain size, or texture, of bulk (cm-sized) samples. In the current setup, the beam spot has a 10 mm diameter. Using a collimator, consisting of two pairs of neutron absorbing boron-nitride slabs, horizontal and vertical dimensions of a rectangular beam spot can be defined. Using the HIPPO robotic sample changer for sample motion, the collimator would enable scanning of e.g. cylindrical samples along the cylinder axis by probing slices of such samples. The project presented here describes implementation of such a collimator, in particular the motion control software. We utilized the EPICS (Experimental Physics Interface and Control System) software interface to integrate the collimator control into the HIPPO instrument control system. Using EPICS, commands are sent to commercial stepper motors that move the beam windows.

43 PARTICLE ACCELERATORS↗

Artifacts from manganese reduction in rock samples prepared by focused ion beam (FIB) slicing for X-ray microspectroscopy

The spatial distribution oftransition metal valence states is of broad interest in the microanalysis ofgeological and environmental samples. An example is rock varnish, a naturalmanganese (Mn)-rich rock coating, whose genesis mechanism remains a subjectof scientific debate. We conducted scanning transmission X-ray microscopywith near-edge X-ray absorption fine-structure spectroscopy (STXM-NEXAFS)measurements of the abundance and spatial distribution of different Mnoxidation states within the nano- to micrometer thick varnish crusts. Suchmicroanalytical measurements of thin and hard rock crusts require samplepreparation with minimal contamination risk. Focused ion beam (FIB) slicingwas used to obtain ~100–1000 nm thin wedge-shaped slices of thesamples for STXM, using standard parameters. Yet, while this preparationis suitable for investigating element distributions and structures in rocksamples, we observed artifactual modifications of the Mn oxidation states atthe surfaces of the FIB slices. Our results imply that the preparationcauses a reduction of Mn 4+ to Mn 2+ . We draw attention tothis issue, since FIB slicing, scanning electron microscopy (SEM) imaging,and other preparation and visualization techniques operating in thekilo-electron-volt range are well-established in geosciences, but researchersare often unaware of the potential for the reduction of Mn and possibly otherelements in the samples.

58 GEOSCIENCES↗

HipGISAXS

Implementation of a flexible Grazing Incidence Small-Angle Scattering (GISAXS). Simulation code based on the Distorted Wave Born Approximation (DWBA) theory that effectively utilizes the parallel processing power provided by graphic processors and multicore processors. This constitutes a handy tool for experimentalists facing a massive flux of data, allowing them to accurately simulate the GISAXS process and analyze the produced data. The software computes the diffraction image for any given super position of custom shapes or morphologies in a user-defined region of the reciprocal space for all possible grazing incidence angles and in-plane sample rotations. This flexibility then allows to easily tackle a wide range of possible sample structures such as nanoparticles o top of or embedded in a substrate or a multilayered structure. In cases where the sample displays regions of significant refractive index contrast, an algorithm has been implemented to perform a slicing of the sample along the vertical direction and compute the averaging refractive index profile to be used as the reference geometry of the unpertubed system. Preliminary tests show good agreement with experimental data for a variety of commonly encountered nanostructures.

Xiaoye, Sherry Li↗