Search NASA⌕ Search

SEARCH · Search NASA

Results for “smear samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Stack Characterization System Development and Testing

Oak Ridge National Laboratory, as well as the rest of the U.S. Department of Energy community, has numerous off-gas stacks that need to be decommissioned, demolished, and packaged for disposal. Disposal requires a waste disposition determination phase. Process knowledge typically makes a worst-case scenario decision that may place lower-level waste into a more expensive higher-level waste disposal category. Truly useful radiological and chemical sampling can be problematic on old stacks due to their inherent height and access hazards, and many of these stacks have begun to deteriorate structurally. A remote stack characterization system (SCS) that can manage sample and data collection removes people from the hazards and provides an opportunity for access to difficult to reach internal stack areas. The SCS is a remotely operated articulated radiological data recovery system designed to deploy down into off-gas stacks from the top via crane. The battery-powered SCS is designed to stabilize itself against the stack walls and move various data recovery systems into areas of interest on the inner stack walls. Stabilization is provided by a tripod structure; sensors are mounted in a rotatable bipod underneath the tripod. Sensors include a beta/gamma/alpha detector, a removable contaminant multi-sample automated sampler, and a multi-core remote core drill. Multiple cameras provide remote task viewing, support for sampling, and video documentation of the process. A delay in funding has delayed project delivery somewhat. Therefore, this paper describes the technology and shows fabrication and testing progress to the extent that data is available.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Transportation of Low-Level Radioactive Waste from KAERI to the Final Repository - 18179

The Korea Atomic Energy Research Institute (KAERI) collects the radioactive wastes generated during the operation of nuclear facilities and R and D processes. Radioactive wastes are treated and repackaged according to the national radioactive waste management policy, and then transferred to the final disposal site at the Korea Radioactive Waste Agency (KORAD). After 2015, the wastes delivered to the final disposal site have consisted of spent filters and combustible wastes such as clothes and gloves generated during R and D or facility operation processes at KAERI. The wastes generated by each facility are collected at the radioactive waste treatment facility, then treated and repackaged in 200 L drums according to their generation characteristics, i.e. each drum contains waste of the same type from the same facility, and with the same date of generation. Then, a radionuclide inventory is obtained for the repackaged drum by using a direct measurement method such as the drum assay system, radiochemical analysis through random sampling or an indirect measurement method such as applying a scaling factor. When performing sampling of the radioactive waste drums, the waste samples with a high contamination are selected in a conservative approach as representative. The radioactive waste drums are inspected and checked for acceptability by the Quality Management Division of KAERI, and a preliminary inspection is carried out on-site by KORAD. At this time, the acceptability of the radioactive waste drums is assessed through visual inspection, the appropriateness of their nuclide analysis value is confirmed, and a survey or smear test of sample drums is performed. Drums that meet the acceptance criteria are transferred to KORAD after a radiation environmental impact assessment of the transportation. Since 2015, 1,084 low-level operational radioactive wastes have been transferred from KAERI to the final disposal site, and further preparation work is now being made for the transportation of additional drums. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A search for anisotropy in the arrival directions of ultra high energy cosmic rays recorded at the Pierre Auger Observatory

Observations of cosmic ray arrival directions made with the Pierre Auger Observatory have previously provided evidence of anisotropy at the 99% CL using the correlation of ultra high energy cosmic rays (UHECRs) with objects drawn from the Véron-Cetty Véron catalog. In this paper we report on the use of three catalog independent methods to search for anisotropy. The 2pt–L, 2pt+ and 3pt methods, each giving a different measure of self-clustering in arrival directions, were tested on mock cosmic ray data sets to study the impacts of sample size and magnetic smearing on their results, accounting for both angular and energy resolutions. If the sources of UHECRs follow the same large scale structure as ordinary galaxies in the local Universe and if UHECRs are deflected no more than a few degrees, a study of mock maps suggests that these three methods can efficiently respond to the resulting anisotropy with a P-value = 1.0% or smaller with data sets as few as 100 events. Using data taken from January 1, 2004 to July 31, 2010 we examined the 20,30,...,110 highest energy events with a corresponding minimum energy threshold of about 49.3 EeV. The minimum P-values found were 13.5% using the 2pt-L method, 1.0% using the 2pt+ method and 1.1% using the 3pt method for the highest 100 energy events. In view of the multiple (correlated) scans performed on the data set, these catalog-independent methods do not yield strong evidence of anisotropy in the highest energy cosmic rays.

79 ASTRONOMY AND ASTROPHYSICS↗

Lensing Constraints on the Mass Profile Shape and the Splashback Radius of Galaxy Clusters

The lensing signal around galaxy clusters can, in principle, be used to test detailed predictions for their average mass profile from numerical simulations. However, the intrinsic shape of the profiles can be smeared out when a sample that spans a wide range of cluster masses is averaged in physical length units. This effect especially conceals rapid changes in gradient such as the steep drop associated with the splashback radius, a sharp edge corresponding to the outermost caustic in accreting halos. We optimize the extraction of such local features by scaling individual halo profiles to a number of spherical overdensity radii, and apply this method to 16 X-ray-selected, high-mass clusters targeted in the Cluster Lensing And Supernova survey with Hubble. By forward-modeling the weak- and strong-lensing data presented by Umetsu et al., we show that, regardless of the scaling overdensity, the projected ensemble density profile is remarkably well described by a Navarro–Frenk–White (NFW) or Einasto profile out to R∼2.5 h{sup −1} Mpc, beyond which the profiles flatten. We constrain the NFW concentration to c{sub 200c}=3.66±0.11 at M{sub 200c}≃1.0×10{sup 15} h{sup −1} M{sub ⊙}, consistent with and improved from previous work that used conventionally stacked lensing profiles, and in excellent agreement with theoretical expectations. Assuming the profile form of Diemer and Kravtsov and generic priors calibrated from numerical simulations, we place a lower limit on the splashback radius of the cluster halos, if it exists, of R{sub sp}{sup 3D}/r{sub 200m}>0.89 (R{sub sp}{sup 3D}>1.83 h{sup −1} Mpc) at 68% confidence. The corresponding density feature is most pronounced when the cluster profiles are scaled by r{sub 200m}, and smeared out when scaled to higher overdensities.

79 ASTRONOMY AND ASTROPHYSICS↗

Phase-weighted slant stacking for surface wave dispersion measurement

SUMMARY Surface wave retrieval from ambient noise records using seismic interferometry techniques has been widely used for multiscale shear wave velocity (Vs) imaging. One key step during Vs imaging is the generation of dispersion spectra and the extraction of a reliable dispersion curve from the retrieved surface waves. However, the sparse array geometry usually affects the ability for high-frequency (>1 Hz) seismic signals’ acquisition. Dispersion measurements are degraded by array response due to sparse sampling and often present smeared dispersion spectra with sidelobe artefacts. Previous studies usually focus on interferograms’ domain (e.g. cross-correlation function) and attempt to enhance coherent signals before dispersion measurement. We propose an alternative technique to explicitly deblur dispersion spectra through use of a phase-weighted slant-stacking algorithm. Numerical examples demonstrate the strength of the proposed technique to attenuate array responses as well as incoherent noise. Three different field examples prove the flexibility and superiority of the proposed technique: the first data set consists of ambient noise records acquired using a nodal seismometer array; the second data set utilizes distributed acoustic sensing (DAS) and a marine fibre-optic cable to acquire a similar ambient noise data set; the last data set is a vibrator-based active-source surface wave data. The enhanced dispersion measurements provide cleaner and higher-resolution spectra without distortions which will assist both human interpreters as well as ML algorithms in efficiently picking curves for subsequent Vs inversion.

58 GEOSCIENCES↗

Energetic electrons in the magnetophere of Saturn

The energy spectra and angular distributions of electrons observed by Pioneer 11 as a function of radial distance in the inner magnetosphere of Saturn are reanalyzed and phase space densities are then calculated. The radial dependence of phase space density requires a distributed loss process. The loss is greatest in the region of the E ring (5.5 less than L less than 8.5) and is attributed to collisions with the ring particles in agreement with earlier work by Van Allen et al. (1980b). Quantitative analysis yields the following properties of the E ring: the particle radii are in the range of 4 x 10(exp -5) to 3.2 x 10(exp -4) cm and the thickness of the ring is approximately 3 R(sub s). Between the inner edge of the E ring (5.5 R(sub s)) and the outer edge of the A ring (2.3 R(sub s)) there are more energetic electrons than can be supplied by radial diffusion from an external source. Detailed calculations show that a cosmic ray albedo neutron decay (CRAND) source in the A and B rings is a plausible source for this excess. The radial diffusion coefficient required to explain the E ring absorption and CRAND source for electrons is 1 x 10(exp -12) greater than D(sub 0) greater than 3 x 10(exp -12) R(sub s)(exp 2)/s, assuming that D(sub LL) = D(sub 0)L(exp 3). As part of the reanalysis program, a method for the deconvolution of pitch angle distributions observed by simple detectors on a rotating spacecraft is developed. This process removes the instrumental response and rotational smear due to finite sampling periods and yields true angular distributions.

Randall, B. A.↗

Energetic electrons in the magnetosphere of Saturn

The energy spectra and angular distributions of electrons observed by Pioneer 11 as a function of radial distance in the inner magnetosphere of Saturn are reanalyzed and phase space densities are then calculated. The radial dependence of phase space density requires a distributed loss process. The loss is greatest in the region of the E ring (5.5 less than L less than 8.5) and is attributed to collisions with the ring particles in agreement with earlier work by Van Allen et al. (1980). Quantitative analysis yields the following properties of the E ring: the particle radii are in the range of 4 x 10(exp -5) to 3.2 x 10(exp -4) cm and the thickness of the ring is approximately 3 R(sub s). Between the inner edge of the E ring (5.5 R(sub s)) and the outer edge of the A ring (2.3 R(sub s)) there are more energetic electrons than can be supplied by radial diffusion from an external source. Detailed calculations show that a cosmic ray albedo neutron decay (CRAND) source in the A and B rings is a plausible source for this excess. The radial diffusion coefficient required to explain the E ring absorption and CRAND source for electrons is 1 x 10(exp -12) greater than D(sub 0) greater than 3 x 10(exp -12) R(exp 2, sub s)/s, assuming that D(sub LL) = D(sub 0)L(exp 3). As part of the reanalysis program, a method for the deconvolution of pitch angle distributions observed by simple detectors on a rotating spacecraft is developed. This process removes the instrumental response and rotational smear due to finite sampling periods and yields true angular distributions.

Randall, B. A.↗

Compact, Automated Centrifugal Slide-Staining System

The Directional Acceleration Vector-Driven Displacement of Fluids (DAVD-DOF) system, under development at the time of reporting the information for this article, would be a relatively compact, automated, centrifugally actuated system for staining blood smears and other microbiological samples on glass microscope slides in either a microgravitational or a normal Earth gravitational environment. The DAVD-DOF concept is a successor to the centrifuge-operated slide stainer (COSS) concept, which was reported in Slide-Staining System for Microgravity or Gravity (MSC-22949), NASA Tech Briefs, Vol. 25, No. 1 (January, 2001), page 64. The COSS includes reservoirs and a staining chamber that contains a microscope slide to which a biological sample is affixed. The staining chamber is sequentially filled with and drained of staining and related liquids from the reservoirs by use of a weighted plunger to force liquid from one reservoir to another at a constant level of hypergravity maintained in a standard swing-bucket centrifuge. In the DAVD-DOF system, a staining chamber containing a sample would also be sequentially filled and emptied, but with important differences. Instead of a simple microscope slide, one would use a special microscope slide on which would be fabricated a network of very small reservoirs and narrow channels connected to a staining chamber (see figure). Unlike in the COSS, displacement of liquid would be effected by use of the weight of the liquid itself, rather than the weight of a plunger.

Feeback, Daniel L.↗

BATSE analysis techniques for probing the GRB spatial and luminosity distributions

The Burst And Transient Source Experiment (BATSE) has measured homogeneity and isotropy parameters from an increasingly large sample of observed gamma-ray bursts (GRBs), while also maintaining a summary of the way in which the sky has been sampled. Measurement of both of these are necessary for any study of the BATSE data statistically, as they take into account the most serious observational selection effects known in the study of GRBs: beam-smearing and inhomogeneous, anisotropic sky sampling. Knowledge of these effects is important to analysis of GRB angular and intensity distributions. In addition to determining that the bursts are local, it is hoped that analysis of such distributions will allow boundaries to be placed on the true GRB spatial distribution and luminosity function. The technique for studying GRB spatial and luminosity distributions is direct. Results of BATSE analyses are compared to Monte Carlo models parameterized by a variety of spatial and luminosity characteristics.

Hakkila, Jon↗

Independent Verification Survey of the High Flux Beam Reactor, Building 802 Fan House Brookhaven National Laboratory Upton, New York (Final Report)

On May 9, 2011, ORISE conducted verification survey activities including scans, sampling, and the collection of smears of the remaining soils and off-gas pipe associated with the 802 Fan House within the HFBR (High Flux Beam Reactor) Complex at BNL. ORISE is of the opinion, based on independent scan and sample results obtained during verification activities at the HFBR 802 Fan House, that the FSS (final status survey) unit meets the applicable site cleanup objectives established for as left radiological conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radioactive Waste Characterization Strategies; Comparisons Between AK/PK, Dose to Curie Modeling, Gamma Spectroscopy, and Laboratory Analysis Methods- 12194

In the coming fiscal years of potentially declining budgets, Department of Energy facilities such as the Los Alamos National Laboratory (LANL) will be looking to reduce the cost of radioactive waste characterization, management, and disposal processes. At the core of this cost reduction process will be choosing the most cost effective, efficient, and accurate methods of radioactive waste characterization. Central to every radioactive waste management program is an effective and accurate waste characterization program. Choosing between methods can determine what is classified as low level radioactive waste (LLRW), transuranic waste (TRU), waste that can be disposed of under an Authorized Release Limit (ARL), industrial waste, and waste that can be disposed of in municipal landfills. The cost benefits of an accurate radioactive waste characterization program cannot be overstated. In addition, inaccurate radioactive waste characterization of radioactive waste can result in the incorrect classification of radioactive waste leading to higher disposal costs, Department of Transportation (DOT) violations, Notice of Violations (NOVs) from Federal and State regulatory agencies, waste rejection from disposal facilities, loss of operational capabilities, and loss of disposal options. Any one of these events could result in the program that mischaracterized the waste losing its ability to perform it primary operational mission. Generators that produce radioactive waste have four characterization strategies at their disposal: - Acceptable Knowledge/Process Knowledge (AK/PK); - Indirect characterization using a software application or other dose to curie methodologies; - Non-Destructive Analysis (NDA) tools such as gamma spectroscopy; - Direct sampling (e.g. grab samples or Surface Contaminated Object smears) and laboratory analytical; Each method has specific advantages and disadvantages. This paper will evaluate each method detailing those advantages and disadvantages including; - Cost benefit analysis (basic materials costs, overall program operations costs, man-hours per sample analyzed, etc.); - Radiation Exposure As Low As Reasonably Achievable (ALARA) program considerations; - Industrial Health and Safety risks; - Overall Analytical Confidence Level. The concepts in this paper apply to any organization with significant radioactive waste characterization and management activities working to within budget constraints and seeking to optimize their waste characterization strategies while reducing analytical costs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determination of Small Animal Long Bone Properties Using Densitometry

Assessment of bone structural property changes due to loading regimens or pharmacological treatment typically requires destructive mechanical testing and sectioning. Our group has accurately and non-destructively estimated three dimensional cross-sectional areal properties (principal moments of inertia, Imax and Imin, and principal angle, Theta) of human cadaver long bones from pixel-by-pixel analysis of three non-coplanar densitometry scans. Because the scanner beam width is on the order of typical small animal diapbyseal diameters, applying this technique to high-resolution scans of rat long bones necessitates additional processing to minimize errors induced by beam smearing, such as dependence on sample orientation and overestimation of Imax and Imin. We hypothesized that these errors are correctable by digital image processing of the raw scan data. In all cases, four scans, using only the low energy data (Hologic QDR-1000W, small animal mode), are averaged to increase image signal-to-noise ratio. Raw scans are additionally processed by interpolation, deconvolution by a filter derived from scanner beam characteristics, and masking using a variable threshold based on image dynamic range. To assess accuracy, we scanned an aluminum step phantom at 12 orientations over a range of 180 deg about the longitudinal axis, in 15 deg increments. The phantom dimensions (2.5, 3.1, 3.8 mm x 4.4 mm; Imin/Imax: 0.33-0.74) were comparable to the dimensions of a rat femur which was also scanned. Cross-sectional properties were determined at 0.25 mm increments along the length of the phantom and femur. The table shows average error (+/- SD) from theory of Imax, Imin, and Theta) over the 12 orientations, calculated from raw and fully processed phantom images, as well as standard deviations about the mean for the femur scans. Processing of phantom scans increased agreement with theory, indicating improved accuracy. Smaller standard deviations with processing indicate increased precision and repeatability. Standard deviations for the femur are consistent with those of the phantom. We conclude that in conjunction with digital image enhancement, densitometry scans are suitable for non-destructive determination of areal properties of small animal bones of comparable size to our phantom, allowing prediction of Imax and Imin within 2.5% and Theta within a fraction of a degree. This method represents a considerable extension of current methods of analyzing bone tissue distribution in small animal bones.

Breit, Gregory A.↗

Defined PEG smears as an alternative approach to enhance the search for crystallization conditions and crystal-quality improvement in reduced screens

An alternative strategy for PEG sampling is suggested through the use of four newly defined PEG smears to enhance chemical space in reduced screens with a benefit towards protein crystallization. The quest for an optimal limited set of effective crystallization conditions remains a challenge in macromolecular crystallography, an issue that is complicated by the large number of chemicals which have been deemed to be suitable for promoting crystal growth. The lack of rational approaches towards the selection of successful chemical space and representative combinations has led to significant overlapping conditions, which are currently present in a multitude of commercially available crystallization screens. Here, an alternative approach to the sampling of widely used PEG precipitants is suggested through the use of PEG smears, which are mixtures of different PEGs with a requirement of either neutral or cooperatively positive effects of each component on crystal growth. Four newly defined smears were classified by molecular-weight groups and enabled the preservation of specific properties related to different polymer sizes. These smears not only allowed a wide coverage of properties of these polymers, but also reduced PEG variables, enabling greater sampling of other parameters such as buffers and additives. The efficiency of the smear-based screens was evaluated on more than 220 diverse recombinant human proteins, which overall revealed a good initial crystallization success rate of nearly 50%. In addition, in several cases successful crystallizations were only obtained using PEG smears, while various commercial screens failed to yield crystals. The defined smears therefore offer an alternative approach towards PEG sampling, which will benefit the design of crystallization screens sampling a wide chemical space of this key precipitant.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Analysis of Waste Isolation Pilot Plan (WIPP) Underground and MGO Samples by the Savannah River National Laboratory (SRNL)

Analysis of the recent WIPP samples are summarized in this report; WIPP Cam Filters 4, 6, 9 (3, 7, 11 were analyzed with FAS-118 in a separate campaign); WIPP Drum Lip R16 C4; WIPP Standard Waste Box R15 C5; WIPP MgO R16 C2; WIPP MgO R16 C4; WIPP MgO R16 C6; LANL swipes of parent drum; LANL parent drum debris; LANL parent drum; IAEA Swipe; Unused “undeployed” Swheat; Unused “undeployed” MgO; and Masselin cloth “smears”. Analysis showed that the MgO samples were very pure with low carbonate and water content. Other samples showed the expected dominant presence of Mg, Na and Pb. Parent drum debris sample was mildly acidic. Interpretation of results is not provided in this document, but rather to present and preserve the analytical work that was performed. The WIPP Technical Analysis Team is responsible for result interpretation which will be written separately.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nodal Quasiparticle Meltdown in Ultra-High Resolution Pump-Probe Angle-Resolved Photoemission

High-T{sub c} cuprate superconductors are characterized by a strong momentum-dependent anisotropy between the low energy excitations along the Brillouin zone diagonal (nodal direction) and those along the Brillouin zone face (antinodal direction). Most obvious is the d-wave superconducting gap, with the largest magnitude found in the antinodal direction and no gap in the nodal direction. Additionally, while antin- odal quasiparticle excitations appear only below T{sub c}, superconductivity is thought to be indifferent to nodal excitations as they are regarded robust and insensitive to T{sub c}. Here we reveal an unexpected tie between nodal quasiparticles and superconductivity using high resolution time- and angle-resolved photoemission on optimally doped Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+{delta}} . We observe a suppression of the nodal quasiparticle spectral weight following pump laser excitation and measure its recovery dynamics. This suppression is dramatically enhanced in the superconducting state. These results reduce the nodal-antinodal dichotomy and challenge the conventional view of nodal excitation neutrality in superconductivity. The electronic structures of high-Tc cuprates are strongly momentum-dependent. This is one reason why the momentum-resolved technique of angle-resolved photoemission spectroscopy (ARPES) has been a central tool in the field of high-temperature superconductivity. For example, coherent low energy excitations with momenta near the Brillouin zone face, or antinodal quasiparticles (QPs), are only observed below T{sub c} and have been linked to superfluid density. They have therefore been the primary focus of ARPES studies. In contrast, nodal QPs, with momenta along the Brillouin zone diagonal, have received less attention and are usually regarded as largely immune to the superconducting transition because they seem insensitive to perturbations such as disorder, doping, isotope exchange, charge ordering, and temperature. Clearly, finding any strong dependencies of the nodal QPs will alter the conventional view and enrich our understanding of high temperature superconductivity. Time resolution through pump-and-probe techniques adds a new dimension to ARPES by directly measuring how the electronic structure of a material responds to perturbations on femtosecond time scales. Here we report a unique ultrafast time-resolved ARPES study of a high-T{sub c} cuprate superconductor. Compared to previous time-resolved studies, the primary advantage of this work is an unprecedented momentum (angular) resolution ({Delta} k~ 0.003 vs. 0.05 { Angstrom}{sup -1}), on par with that of state-of-the-art ARPES. This has allowed the time-resolved measurement of signi cantly sharper QP spectral peaks with strikingly larger peak-to-background ratios than previously reported.16 Additionally, a lower pump fluence is used (<40{micro} J/cm{sup 2} vs. 100 {micro}J/cm{sup 2}), which reduces pump-induced sample temperature increase and related thermal smearing of spectral features. This allows us to uncover a surprising meltdown of nodal QP spectral weight following pump laser excitation. This meltdown is only observed in the superconducting state and for QPs with binding energy less than the kink energy,19 revealing a link between nodal QPs and superconductivity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Independent Confirmatory Survey Results of Soils Associated with the Argyle Street Sewer Line at the United Nuclear Corporation Naval Products Site, New Haven, Connecticut (Letter Report)

Oak Ridge Institute for Science and Education (ORISE) personnel visited the United Nuclear Corporation (UNC) Naval Products site on three separate occasions during the months of October and November 2011. The purpose of these visits was to conduct confirmatory surveys of soils associated with the Argyle Street sewer line that was being removed. Soil samples were collected from six different, judgmentally determined locations in the Argyle Street sewer trench. In addition to the six soil samples collected by ORISE, four replicate soil samples were collected by Cabrera Services, Inc. (CSI) for analysis by the ORISE laboratory. Replicate samples S0010 and S0011 were final status survey (FSS) bias samples; S0012 was an FSS systematic sample; and S0015 was a waste characterization sample. Six soil samples were also collected for background determination. Uranium-235 and uranium-238 concentrations were determined via gamma spectroscopy; the spectra were also reviewed for other identifiable photopeaks. Radionuclide concentrations for these soil samples are provided. In addition to the replicate samples and the samples collected by ORISE, CSI submitted three soil samples for inter-laboratory comparison analyses. One sample was from the background reference area, one was from waste characterization efforts (material inside the sewer line), and one was a FSS sample. The inter-laboratory comparison analyses results between ORISE and CSI were in agreement, except for one sample collected in the reference area. Smear results For Argyle Street sewer pipes are tabulated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improved particulate-sampling filter

Small surface indentations entrain larger and more representative sampling than conventional petri-dish smeared with smooth layer adhesive. Filter is assembled from perforated disk and flat backing plate with sticky surface. Due to design-created currents, particulates come in contact with surface for longer time and have greater probability of being trapped. Filter is useful in air-quality monitoring at industrial sites, in mines, and in and around nuclear power plants.

Hoffman, A. R.↗

A Novel and Cost Effective Approach to the Decommissioning and Decontamination of Legacy Glove Boxes - Minimizing TRU Waste and Maximizing LLW Waste - 13634

This paper describes the process of decommissioning two gloveboxes at the Argonne National Laboratory (ANL) that were employed for work with plutonium and other radioactive materials. The decommissioning process involved an initial phase of clearing tools and materials from the glove boxes and disconnecting them from the laboratory infrastructure. The removed materials, assessed as Transuranic (TRU) waste, were packaged into 55 gallon (200 litre) drums and prepared for ultimate disposal at the Waste Isolation Pilot Plant (WIPP) at Carlsbad New Mexico. The boxes were then sampled to determine the radioactive contents by means of smears that were counted with alpha and beta detectors to determine the residual surface contamination, especially in terms of alpha particle emitters that are an indicator of TRU activity. Paint chip samples were also collected and sent for laboratory analysis in order to ascertain the radioactive contamination contributing to the TRU activity as a fixed contamination. The investigations predicted that it may be feasible to reduce the residual surface contamination and render the glovebox structure low level waste (LLW) for disposal. In order to reduce the TRU activity a comprehensive decontamination process was initiated using chemical compounds that are particularly effective for lifting and dissolving radionuclides that adhere to the inner surfaces of the gloveboxes. The result of the decontamination process was a reduction in the TRU surface activity on the inner surfaces of the gloveboxes by four orders of magnitude in terms of disintegrations per unit area (DPA). The next phase of the process involved a comprehensive assay of the gloveboxes using a combination of passive neutron and gamma ray scintillation detectors and a shielded and collimated high purity Germanium (HPGe) gamma ray detector. The HPGe detector was used to obtain gamma ray spectra for a variety of measurement positions within the glovebox. The spectra were used to determine the TRU content of the boxes by assessing the activity of Am-241 (59 keV) and Pu-241 (414 keV). Using the data generated it was possible for qualified subject matter experts (SME) to assess that the gloveboxes could be consigned for disposition as LLW and not as TRU. Once this determination was assessed and accepted the gloveboxes were prepared for final disposition to the Nevada National Security Site (NNSS) - formerly the Nevada Test Site (NTS). This preparation involved fixing any remaining radioactive contamination within the gloveboxes by filling them with a foam compound, prior to transportation. Once the remaining contamination was fixed the gloveboxes were removed from the laboratory and prepared for transported by road to NNSS. This successful glovebox decontamination and decommissioning process illustrates the means by which TRU waste generation has been minimized, LLW generation has been maximized, and risk has been effectively managed. The process minimizes the volume of TRU waste and reduced the decommissioning time with significant cost savings as the result. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗