Search NASA⌕ Search

SEARCH · Search NASA

Results for “smooth pursuit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Evaluation of Saccadic Component Measure on Smooth Pursuit Tests

ABSTRACT Introduction Despite the advancement of eye-tracking technology for smooth pursuit (SP) eye movement evaluation, qualitative observation offers much information that is not captured by computers; hence, both objective and qualitative information should be utilized to evaluate SP. This study examined the consistency among our clinicians when evaluating SP using normal (N), grossly normal (GN), mildly abnormal (MA), and abnormal (AB) as classifications. We then evaluated the effect of combining GN and MA into a single subclinical (SUBC) category. We also evaluated the computerized percent saccade (PS) metric by determining its sensitivity and specificity in classifying SP. Materials and Methods Retrospective horizontal and vertical SP test videos and numerical data for 70 participants were obtained from the Neuro Kinetics Neuro-Otologic Test Center and de-identified. From this, eye-tracking videos, time plots of eye-tracking positional data, and tables of SP eye-tracking performance data were generated for 0.1, 0.3, and 0.5 Hz in both horizontal and vertical planes, totaling 6 tests per subject. Three clinicians rated each subject’s SP performance as N, GN, MA, or AB for a total of 6 ratings (3 frequencies, horizontal and vertical). This process was repeated using N, SUBC, and AB as rating categories. Clinicians also provided an overall SP rating for each plane as follows: AB if the results were abnormal for 2 or more frequencies tested. Alternatively, if fewer than 2 frequencies presented with a rating of AB, then an overall rating of MA, GN, or N was determined at the respective clinician’s discretion. Results When the 3 clinicians were tasked with classifying SP videos using 4 clinical categories, fair overall agreement was demonstrated. However, when MA and GN categories were combined into an SUBC category, the overall agreement for the 3 clinicians improved slightly for both horizontal SP (HSP) and vertical SP (VSP). This pattern of agreement did not differ considerably when comparing HSP versus VSP, and good consistency and reliability was observed across clinicians. Again, inter-rater consistency was smaller for VSP versus HSP despite the reduction in clinical categories. Cut-off values were generated for the PS metric and demonstrated good specificity and sensitivity when they were exceeded for 2 or more frequencies in a particular plane when evaluating a subject’s SP test. Conclusions

General & Internal Medicine↗

Normative Ranges for Oculomotor and Reaction Time Tests in U.S. Military Service Members and Veterans

AbstractBackground Oculomotor and reaction time tests are frequently used assessments of vestibular symptoms, traumatic brain injury (TBI), or other neurological disorders in both clinical and research contexts. When interpreting these tests it is important to have a reference interval (RI) as a comparison for what constitutes a typical/expected response; however, the current body of research has only limited information regarding normative ranges calculated according to established standards or for a military-specific sample.Purpose The purpose of the present study was to describe RIs for oculomotor and reaction time tests in a cohort of service members and veterans (SMVs) for use as comparators by clinicians and scientists.Research Design Descriptive.Study Sample Participants were prospectively enrolled in the Defense and Veterans Brain Injury Center-Traumatic Brain Injury Center of Excellence 15-year Longitudinal Traumatic Brain Injury Study. Only SMVs without a history of TBI or blast exposure were included in the RI calculations.Data Collection and Analysis The test paradigms included in this analysis were: smooth pursuit, prosaccades, antisaccades, saccades and reaction time, predictive saccades, optokinetic nystagmus, auditory reaction time, and visual reaction time. Nonparametric methods, based on the U.S. Food and Drug Administration's recognized consensus standards, were used to calculate 95% RIs. A comparison between the calculated RIs and those available from previously published research is provided.Results Summary statistics and RIs were calculated for 47 outcome parameters from 13 oculomotor and reaction time tests. Sample sizes and age ranges varied across outcome parameters depending on the availability of reference values for RI calculations. The sample sizes used to calculate RIs ranged from 51 to 69. The age of SMVs included in each RI ranged from 19 to 61 years with mean ages ranging from 37 to 39 years. Similarities/differences between the RIs in the present study and those in previously published research are highly dependent on the outcome parameter; however, in general, the RIs in the present study tended to be somewhat wider.Conclusion The RIs provided in this paper can serve as comparisons for clinicians and scientists who are utilizing these oculomotor and reaction time testing paradigms in similar cohorts of patients or research participants.

Audiology & Speech-Language Pathology↗

Surrogate model for third-integer resonance extraction at the Fermilab Delivery Ring

We present an ongoing work in which a surrogate model is being developed to reproduce the response dynamics of the third-integer resonant extraction process in the Delivery Ring (DR) at Fermilab. This is in pursuit of smoothly extracting circulating beam to the Mu2e Experiment’s production target, whereby the goal is to extract a uniform slice of the circulating 1e12 protons in the DR over 25,000 turns (43 ms). The DR contains 3 harmonic sextupoles that excite a third-integer resonance and three fast, tune-ramping quadrupole magnets that drive the horizontal tune towards the 29/3 resonance. In our initial work, the surrogate model trains on a semi-analytical simulation provided in the same format as live data. Using Reinforcement Learning (and other potential ML methods), the trained surrogate acts as the “environment” in which a simple ML control agent could learn to dynamically adjust the quadrupole ramp at 430 break points within the 43 microsecond spill window. The controller will be hosted on a dedicated Arria 10 FPGA. In this work, we report the accuracy and fidelity of the surrogate model in comparison to the response dynamics of the physics simulator.

Narayanan, Aakaash [Fermilab]↗

Surrogate Modelling of 3rd Integer Resonant Extraction at Fermilab Delivery Ring

We present an ongoing work in which a surrogate model is being developed to reproduce the response dynamics of the third-integer resonant extraction process in the Delivery Ring (DR) at Fermilab. This effort is in pursuit of smoothly extracting circulating beam to the Mu2e Experiment s production target, wherein the goal is to extract a uniform slice of the circulating $1e12$ protons in the DR over 25,000 turns (43~ms). The DR contains 3 harmonic sextupoles which excite a third-integer resonance as well as three fast, tune-ramping quadrupole magnets which drive the horizontal tune towards the $29/3$ resonance. In our initial work the surrogate model trains on a semi-analytical simulation provided in the same format as live data. Using Reinforcement Learning (and other potential ML methods), the trained surrogate acts as the environment in which a simple ML control agent could learn to dynamically adjust the quadrupole ramp at 430 break points within the 43 microsecond spill window. The control agent will be hosted on a dedicated Arria 10 FPGA, introducing its own requirements on control agent architecture. In this work we report the accuracy and fidelity of surrogate models in comparison to the response dynamics of the physics simulator.

Narayanan, Aakaash [Fermilab] (ORCID:0000000157944↗