Search NASA⌕ Search

SEARCH · Search NASA

Results for “software designs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

User-Centered Software Design in the All Hazards Analysis Application

To design good software, you must always keep the end user in mind. Some benefits of incorporating the user-centered design process include saving users time and effort and helping them to utilize all capabilites of an application. In my work on the All Hazards Analysis (AHA) application, I employed principles of user-centered design to make the application easier for new users to navigate. This poster describes user-centered software design in general and showcases some of my user-centered design work on the AHA application.

58 GEOSCIENCES↗

Insights From the Software Design of a Multiphysics Multicomponent Scientific Code

Using simulations for scientific discovery requires that the software used in the simulations undergoes a rigorous design and development process similar to that of the lab instruments in the experimental sciences. To devise a good design methodology, it is critical to understand the requirements, constraints, and challenges. Furthermore, this article describes insights from the long-term stewardship of a multiphysics multicomponent software, FLASH, that was designed more than 20 years ago for astrophysics, now serves multiple communities, and has been successful in adapting to the changing world of high-performance computing.

97 MATHEMATICS AND COMPUTING↗

MIRaGE: Design Software for Metamaterials

Metamaterials are artificial optical structures that allow control of light in ways not found in, or offered by, naturally occurring materials. Sandia's Multiscale Inverse Rapid Group-theory for Engineered-metamaterials (MIRaGE) software, which won an R&D100 award in 2019, allows researchers to deterministically design and produce metamaterials with unique characteristics. MIRaGE also provides powerful autonomous optimization techniques for real-world performance in a rigorous, robust, and accurate manner.

36 MATERIALS SCIENCE↗

Isotopic analysis of plutonium measured with very thick absorbers and high-granularity spectra

FRAM is LANL-designed software designed to extract plutonium and uranium isotopic information from gamma ray spectra. This is an important capability for NEST and STAB; however, FRAM performance has been poor when applied to field data collected in these programs. FRAM Version 5 (commercially available) was fine-tuned and validated for laboratory quality measurements but not for measurements of the high-mass and heavily shielded SNM items encountered in NEST. FRAM is untested for spectra collected with high-granularity lower resolution instruments such as the new 8-MeV Detective-X favored by STAB or the new custom electrocooled systems coming into use for NEST. FRAM Version 6.1 (unreleased) has improvements in physics capabilities, and parameter sets may be adapted that are more specific to NEST and STAB, which is what we have attempted for this assignment. Thick shielding attenuates gamma rays profoundly, especially those at low energy, making them too weak to be measured. The missing low-energy peaks force the analysis to employ only the highest-energy peaks. We adapted FRAM 6.1 for analysis of plutonium spectra obtained with very thick Pb filters (a surrogate for NEST-type configurations). New parameter sets employing only very high energy peaks were created for the analysis. High granularity and low resolution make deconvolution of the 600-keV region particularly challenging, and we have worked to optimally extract information from this region. The results shown in this paper give high confidence that we are on the right track. We used a combination of real and synthetically-modified data. Remaining work includes testing the new software and parameters against genuine data collected with Detective-X and new NEST systems, but such datasets at the moment are unavailable. It also remains to develop and test parameter sets specific to uranium and the new detectors.

07 ISOTOPE AND RADIATION SOURCES↗

COG Software Architecture Design Description Document

This COG Software Architecture Design Description Document describes the organization and functionality of the COG Multiparticle Monte Carlo Transport Code for radiation shielding and criticality calculations, at a level of detail suitable for guiding a new code developer in the maintenance and enhancement of COG. The intended audience also includes managers and scientists and engineers who wish to have a general knowledge of how the code works. This Document is not intended for end-users.

61 RADIATION PROTECTION AND DOSIMETRY↗

CARD: CFD for Advanced Reactor Design

Software Tools and Expertise To Address Multiphase Flow Challenges in<p>Research, Design, and Optimization</p><p>This is the annual CARD project update to be presented at the 2024 FECM/NETL Spring R&amp;D Project Review Meeting.</p>

Dietiker, Jeff↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report (DOE 2023) provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

42 ENGINEERING↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Review of Software for Designing and Operating Quantum Networks

Quantum networks development is crucial to realizing a production-grade network that can support distributed sensing, secure communication, and utility-scale quantum computation. However, the transition from laboratory demonstration to deployable networks requires software implementations of architectures and protocols tailored to the unique constraints of quantum systems. This paper reviews the current state of software implementations for quantum networks, organized around a three-plane abstraction of infrastructure, logical, and control/service planes. We cover software for both designing quantum network protocols (e.g., SeQUeNCe, QuISP, and NetSquid) and operating testbeds, with a focus on essential control/service plane functions such as entanglement, topology, and resource management, in a proposed taxonomy. Our review highlights a persistent gap between theoretical architecture and protocol proposals and their realization in simulators or testbeds, particularly in dynamic topology and network management. We conclude by outlining open challenges and proposing a roadmap for developing scalable software architectures to enable hybrid, large-scale quantum networks.

Network Design↗

Multiphysics for nuclear energy applications using a cohesive computational framework

With the recent development of advanced numerical algorithms, software design, and low-cost high-performance computer hardware, reliance on coupled multiphysics to predict the behavior of complex physical systems is beginning to become standard practice. This is especially true in nuclear energy applications where strong nonlinear interdependencies exist between reactor physics, radiation transport, multi-scale nuclear fuels performance, thermal fluids, etc. Resolving these nonlinear dependencies requires choices in multiphysics software approaches. Two main multiphysics modeling and simulation approaches have emerged. The first is based upon "code coupling" where disparate physics codes of different software design, code languages, and spatial and temporal integration schemes are coupled together with relatively complex data passing interfaces. The second multiphysics software approach is to employ a "cohesive" framework where all physics applications are developed with a common software design, i.e., data structures, syntax, input format, integrated spatial and temporal discretization schemes, etc. In this paper we present the Multiphysics Object-Oriented Simulation Environment (MOOSE) development and runtime framework and describe the framework's cohesive modeling and simulation multiphysics approach. Then, a "cohesive-like" extension of the MOOSE framework is presented where MOOSE-based physics software applications are efficiently coupled to non-MOOSE (external) physics codes to form multiphysics applications using MOOSE's unique interface capabilities. Finally, several examples of MOOSE's cohesive and cohesive-like multiphysics applications will be demonstrated. These multiphysics demonstrations will incorporate both MOOSE-based applications and external codes, including Nek5000, RELAP-7, TRACE, BISON, and Pronghorn.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Perspective on Quantum Computing Applications in Quantum Chemistry Using 25-100 Logical Qubits

The intersection of quantum computing and quantum chemistry represents a promising frontier for achieving quantum utility in domains of both scientific and societal relevance. Owing to the exponential growth of classical resource requirements for simulating quantum systems, quantum chemistry has long been recognized as a natural candidate for quantum computation. This perspective focuses on identifying scientifically meaningful use cases where early fault-tolerant quantum computers, which are considered to be equipped with approximately 25-100 logical qubits, could deliver tangible impact. While recent advances in classical computing have pushed the boundaries of tractable simulations to unprecedented scales, this logical-qubit regime represents the first window where quantum devices can pursue qualitatively distinct strategies, such as polynomial-scaling phase estimation, direct simulation of quantum dynamics, and active-space embedding, that remain challenging for classical solvers, such as multireference charge-transfer and conical-intersection states central to photochemistry and materials design. We highlight near-term opportunities in algorithm and software design, discuss representative chemical problems suited for quantum acceleration, and propose strategic roadmaps and collaborative pathways for advancing practical quantum utility in quantum chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Prediction of stability constants of metal–ligand complexes by machine learning for the design of ligands with optimal metal ion selectivity

The new LOGKPREDICT program integrates HostDesigner molecular design software with the machine learning (ML) program Chemprop. By supplying HostDesigner with predicted log K values, LOGKPREDICT enhances the computer-aided molecular design process by ranking ligands directly by metal–ligand binding strength. Harnessing reliable experimental data from a historic National Institute of Standards and Technology (NIST) database and data from the International Union of Pure and Applied Chemistry (IUPAC), we train message passing neural net algorithms. The multi-metal NIST-based ML model has a root mean square error (RMSE) of 0.629 ± 0.044 (R 2 of 0.960 ± 0.006), while two versions of lanthanide-only IUPAC-based ML models have, respectively, RMSE of 0.764 ± 0.073 (R 2 of 0.976 ± 0.005) and 0.757 ± 0.071 (R 2 of 0.959 ± 0.007). For relative log K predictions on an out-of-sample set of six ligands, demonstrating metal ion selectivity, the RMSE value reaches a commendably low 0.25. Here we showcase the use of LOGKPREDICT in identifying ligands with high selectivity for lanthanides in aqueous solutions, a finding supported by recent experimental evidence. We also predict new ligands yet to be verified experimentally. Therefore, our ML models implemented through LOGKPREDICT and interfaced with the ligand design software HostDesigner pave the way for designing new ligands with predetermined selectivity for competing metal ions in an aqueous solution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗