Search NASA⌕ Search

SEARCH · Search NASA

Results for “software obsolescence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Electronic Component Obsolescence

Electronic component obsolescence occurs when parts are no longer available to support the manufacture and/or repair of equipment still in service. Future instrumentation containing complex components WILL face obsolescence issues as technology advances. This paper describes hardware and software obsolescence as well as factors to consider when designing new instrumentation.

99 GENERAL AND MISCELLANEOUS↗

Upgrade of Core Conduction Cooldown Test Facility Control System

The CCCTF was designed and installed at ORNL in the 1990s for high-temperature gas-cooled reactor accident simulation. It is located within a modular hot cell housed in the IFEL facility. In 2008 and 2009, modifications were made to the CCCTF in preparation for AGR safety testing. A new airlock was designed and installed to better support periodic exchange of the fission product deposition cups while maintaining the fuel at safety test temperature, and modifications were made to add routines to the existing user interface software for computer-controlled automation of the He sweep gas flow and liquid nitrogen supply to the 85Kr cold traps. However, the furnace control hardware and software remained essentially unchanged. At the conclusion of the AGR-1 and AGR-2 PIE campaigns, continued use of the CCCTF was in question because of the gradual obsolescence of the hardware and software used to control the furnace and ancillary systems that make up the CCCTF. Therefore, an effort was undertaken to replace all the obsolete components with new hardware and update the software to increase system reliability and ensure this capability’s maintenance for future research and fuel qualification efforts. The modifications included creating a new National Instruments (NI) LabVIEW-based control system with a graphical user interface (GUI).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Upgrade of Gamma Spectrometry Systems for ORNL TRISO Fuel PIE

Gamma spectrometry is a key element in much of the post-irradiation examination (PIE) work performed under the Advanced Gas Reactor Fuel Development and Qualification (AGR) Program (Demkowicz et al. 2015; Stempien et al. 2021). Gamma spectrometers are integrated into three major capabilities used at the Oak Ridge National Laboratory (ORNL) Irradiated Fuels Examination Laboratory (IFEL) for PIE of tristructural-isotropic (TRISO) coated particles and fuel compacts: the Core Conduction Cooldown Test Facility (CCCTF), the Vertical Counting System (VCS), and the Irradiated Microsphere Gamma Analyzer (IMGA). The CCCTF includes liquid-nitrogen-cooled traps to extract 85 Kr out of the He sweep gas that passes through the furnace in which the fuel compacts are heated during safety testing. Analysis of the 85 Kr activity in the traps is the primary indicator for TRISO failure during safety testing. The VCS is a system used to accurately measure gamma emission from components placed in a lead-shielded chamber. It is used to count the CCCTF deposition cups after removal from furnace. Each cup resides in the CCCTF furnace for typically 12–24 h and is periodically replaced with a fresh cup throughout the safety test. Metallic fission products collect on the water-cooled cups and several gamma-emitting isotopes ( 110 mAg, 134 Cs, 137 Cs, 154 Eu, and 155 Eu) are often measured and provide indication of the retention performance of the TRISO coatings. The VCS is also used to measure the presence of these isotopes on the CCCTF tantalum liner and sweep gas inlet tube for the determination of cup collection efficiency, as well as support other gamma spectrometry needs related to calibration of the 85 Kr fission gas traps and various other special PIE tasks. The IMGA uses gamma spectrometry to measure the inventory of gamma-emitting isotopes in individual TRISO particles. An automated particle handling system within the IMGA hot cell removes each particle from a source vial and positions it in front of a gamma detector, and output from the gamma spectrometer is used by the IMGA software to determine a destination vial such that particles are sorted according to their inventory and retention characteristics. At the conclusion of the AGR-1 and AGR-2 PIE campaigns, the gamma spectrometer systems used at ORNL to support that PIE had reached the end of its life cycle due to gradual obsolescence of the hardware and software. Upgrade of the Canberra Genie 2000 software used by these systems to a Windows 10 version was not a viable option, because the newest Windows 10 version offered by Mirion (the new owner of the Canberra technology) did not include the dynamic-link libraries (DLLs) needed for integration with the custom PIE software used with the CCCTF and IMGA, and Mirion had no current plans for development and release of Windows 10 versions of these DLLs with the Model S560 Genie 2000 Programming Library. Ultimately a switch was made to ORTEC gamma spectrometry systems, which appeared to be a more sustainable solution due to more proactive vendor support. The ORTEC conversion involved replacing the aging detector preamplifier and multichannel analyzer (MCA) hardware, upgrading the obsolete Windows 7 computers to Windows 10 compatible models, adopting ORTEC GammaVision software, and extensive modification of the ORNL-developed Visual Basic .NET (VB.NET) programs that provide the CCCTF and IMGA user interfaces.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards a Robust System-of-Systems Control Architecture for Robotics - 18359

This paper presents the methodology and results of developing and implementing a system-of-systems architecture for controlling many robotic systems within the context of industrial facilities, where the life of the facility will be far longer than the life of the robotics, due to software updates and accelerated digital obsolescence. The use cases are the JET and ITER fusion research reactors. Remote maintenance is both device defining and mission critical for a future fusion reactor and we foresee the need to utilise a considerable number of robotic devices within an overall digital control architecture. The paper will explore the challenges of long term management of digital complexity using the real experience of JET over the last 20 years. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Decade of NSTX Operations Using Collaborative Software

Since the beginning of the National Spherical Torus Experiment's (NSTX) research activities in 1999, open-source and collaborative software have been used extensively for experimental operations. The software included Experimental Physics and Industrial Control System (EPICS) and the Model Data System plus (MDSplus). This paper will begin with a retrospective of ten years of integrated computing, control, and data analysis on NSTX. A variety of practical issues will be reviewed such as: system reliability, availability, and maintainability; using open source software with commercialoff- the-shelf (COTS) hardware; obsolescence and remaining current. Recent improvements, current status, and emerging issues will be presented. Numerous proposals for NSTX upgrades have been made that will extend the performance and operating lifetime of NSTX. In light of this, a collective strategy for improving NSTX's collaborative software model for a new decade of operations will be examined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Insights Gained for Updating an Analog I&C System to a Digital System

Licensees at both Nuclear Power Plants (NPPs) and Non-Power Reactors (NPRs) are increasing their use of state-of-the-art digital technology in instrumentation and control (I&C) systems because digital systems offer improved reactor control, information processing, and information storage over analog. Digital I&C systems can range from experimental systems for reactor control research (at NPRs), to measurement and display systems, to complete reactor console replacements. Because of the increasing difficulty in finding spare parts for their original analog I&C systems, many licensees have begun or have plans to upgrade, refurbish, or replace their old analog I&C systems with digital systems. The perception is that upgrading to a digital I&C system will solve all of a facility s obsolescence problems. However, licensees need to be aware of several issues associated with upgrading to a digital system including obsolescence of the digital system (hardware and software) because of the short product life cycle and the associated cost to acquire, store, and maintain a long-term supply of spare parts. Configuration management and cyber security are also vitally important for any upgrade. Further, it must be recognized that the introduction of software and microprocessors could create new failure mechanisms, such as software errors and increased susceptibility to electromagnetic interference. In fact, experience has shown that these failure mechanisms may cause the reactor to malfunction in a way not previously considered. Thus, a conversion from analog to digital I&C systems solves some problems while potentially introducing others. Recognition of the additional risks coupled with good design, engineering, review, and testing can identify and minimize these risks.

Adams, A.↗

Modernizing the SNS Control System

The Spallation Neutron Source at Oak Ridge National Laboratory has been operating since 2006. An upgrade to double the machine power from 1.4 MW to 2.8 MW is currently underway and a project to add a second target station is in the preliminary design phase. While each project will add the controls needed for their specific scope, the existing control system hardware, software, and infrastructure require upgrades to maintain high availability and ensure the system will meet facility requirements into the future. While some systems have received new hardware due to obsolescence, much of the system is original apart from some maintenance and technology refresh. Software will also become obsolete and must be upgraded for sustainability. Further, requirements for system capacity can be expected to increase as more subsystems upgrade to smarter devices capable of higher data rates. This paper covers planned improvements to the integrated control system with a focus on reliability, sustainability, and future capability.

White, Karen S.↗

Strengthening the Security of Operational Technology: Understanding Contemporary Bill of Materials

The evolution of cyber-physical infrastructure has made its security more challenging. The last few years have witnessed a convergence of hardware and software segments in various domains, including operational technology (OT) which is responsible for carrying out critical tasks such as monitoring and controlling power grids, nuclear plants, transportation, and emergency services. Both hardware and software encapsulate numerous open source and proprietary subcomponents, making it crucial for end-users to understand the composition of the products they are using. For example, wind turbines incorporate thousands of lines of code (software) used for the turbine's design, planning, operation, and analytics in addition to the numerous hardware subcomponents that construct it. Due to the highly complex nature of software and hardware, knowledge of the components and subcomponents is required to mitigate cyber vulnerabilities and defend against cyberattacks. There has also been a transformation from a traditional linear supply chain into a global, dynamic, diverse, and interconnected system. The digitization of the supply chain makes it easier to find and exploit vulnerabilities. Critical infrastructures (e.g., power grids, oil, natural gas, water, and wastewater) rely on OT to function, and if the OT is compromised, equipment damage and potential interruption of services could result. A significant security measure to protect OT systems from disruption is to develop a supply chain bill of materials (BoM) corresponding to the software and hardware used in OT, along with attestations amongst vendors and asset owners. A supply chain BoM is a proactive way to understand the inherent vulnerabilities in the system and mitigate them in advance of being exploited. BoMs bolster the trust placed in the digital infrastructure and enhance software supply chain security by sustaining the management of component obsolescence and compliance, along with the seclusion of unsafe segments of a specific product. Adopting BoM tools is becoming increasingly important across various government sectors, as evidenced by the recent U.S. executive order on cybersecurity (NIST 2021). This paper aims to classify BoMs based on structure, functionality, component type, and architecture. The work also discusses case studies to further highlight the benefits of BoMs. In addition, it identifies missing pieces in existing BoM implementations so that future research may identify bounds on where it could expect to make improvements and directly enable researchers to identify promising areas for exploration. Further, the authors provide valuable recommendations to tool developers, researchers, and standardizing organizations (policymakers), additionally benefitting critical infrastructure owners and government executives. This aids in paving a path for future work, thereby, providing suggestions to determine a tool for consumers that best suit their needs.

97 MATHEMATICS AND COMPUTING↗

Design of a signal conditioner for the Fermilab Magnet Test Facility

This thesis describes the design of a remotely-programmable signal conditioner for the harmonic measurement of accelerator magnets. A 10-channel signal conditioning circuit featuring bucking capabilities was designed from scratch and implemented to the level of the printed circuit board layout. Other system components were chosen from those available on the market. Software design was started with the definition of routine procedures. This thesis is part of an upgrade project for replacing obsolescent automated test equipment belonging to the Fermilab Magnet Test Facility. The design started with a given set of requirements. Using a top-down approach, all the circuits were designed and their expected performances were theoretically predicted and simulated. A limited prototyping phase followed. The printed circuit boards were laid out and routed using a CAD software and focusing the design on maximum electromagnetic interference immunity. An embedded board was selected for controlling and interfacing the signal conditioning circuitry with the instrumentation network. Basic low level routines for hardware access were defined. This work covered the entire design process of the signal conditioner, resulting in a project ready for manufacturing. The expected performances are in line with the requirements and, in the cases where this was not possible, approval of trade-offs was sought and received from the end users. Part I deals with the global structure of the signal conditioner and the subdivision in functional macro-blocks. Part II treats the hardware design phase in detail, covering the analog and digital circuits, the printed circuit layouts, the embedded controller and the power supply selection. Part III deals with the basic hardware-related routines to be implemented in the final software.

43 PARTICLE ACCELERATORS↗

New controller for high voltage converter modulator at spallation neutron source

The Spallation Neutron Source (SNS) has developed a new control system for the High Voltage Convertor Modulator (HVCM) at the SNS to replace the original control system which is approaching obsolescence. The original system was based on controllers for similar high voltage systems that were already in use [1]. The new controller, based on National Instruments PXI/FlexRIO Field Programmable Gate Array (FPGA) platform, offers enhancements such as modular construction, flexibility and non-proprietary software. The new controller also provides new capabilities like various methods for modulator pulse flattening, waveform capture, and first fault detection. This paper will discuss the design of the system, including the human machine interface, based on lessons learned at the SNS and other projects. It will also discuss performance and other issues related to its operation in an accelerator facility which requires high availability. To date, 73% of the operational HVCMs have been upgraded to with the new controller, and the remainder are scheduled for completion by mid-2017.

Wezensky, Mark W↗

Spallation Neutron Source Proton Power Upgrade Low-Level RF Control System Development

The Proton Power Upgrade (PPU) Project is approved for the Spallation Neutron Source at Oak Ridge National Laboratory and will double the proton beam power capability from 1.4 MW to 2.8 MW with 2 MW beam power available to the first target station. A second target station is planned and will utilize the remaining beam power in the future. The proton power increase will be supported with the addition of twenty-eight new superconducting cavities powered by 700 kW peak power klystrons to increase beam energy while increases to the beam current will be done with a combination of existing RF margin, and DTL HPRF upgrades. The original low-level RF control system has proven to be reliable over the past 15 years of operations, but obsolescence issues mandate a replacement system be developed for the PPU project. The replacement system is realized in a µTCA.4 platform using a combination of commercial off-the-shelf boards and custom hardware to support the requirements of PPU. This paper presents the prototype hardware, firmware, and software development activities along with preliminary testing results of the new system.

Crofford, Mark↗

Quantitative evaluation of common cause failures in high safety-significant safety-related digital instrumentation and control systems in nuclear power plants

Digital instrumentation and control (DI&C) systems at nuclear power plants (NPPs) have many advantages over analog systems. They are proven to be more reliable, cheaper, and easier to maintain given obsolescence of analog components. However, they also pose new engineering and technical challenges, such as possibility of common cause failures (CCFs) unique to digital systems. Here this paper proposes a Platform for Risk Assessment of DI&C (PRADIC) that is developed by Idaho National Laboratory (INL). A methodology for evaluation of software CCFs in high safety-significant safety-related DI&C systems of NPPs was developed as part of the framework. The framework integrates three stages of a typical risk assessment—qualitative hazard analysis and quantitative reliability and consequence analyses. The quantified risks compared with respective acceptance criteria provide valuable insights for system architecture alternatives allowing design optimization in terms of risk reduction and cost savings. A comprehensive case study performed to demonstrate the framework's capabilities is documented here in this paper. Results show that the PRADIC is a powerful tool capable to identify potential digital-based CCFs, estimate their probabilities, and evaluate their impacts on system and plant safety.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development and application of FPGA-based logic controller - 357

The control systems of nuclear power plants contain many components which are becoming obsolete at an increasing rate. Nowadays maintenance for analog-based protection systems may be difficult as analog parts become obsolete or hard to obtain. Various studies have been conducted to address this control system hardware obsolescence issue. Those control systems of nuclear power plants have been replaced with modern digital control systems such as the programmable logic controller (PLC) and the distributed control system (DCS). The central processing unit (CPU)- based platforms such as the PLC and the DCS require an operating system (OS) and application software, and thus they might result in a common-cause failure when a problem occurs in the operating system or application software. The field programmable gate array (FPGA) is highlighted as an alternative to the conventional protection or control systems. This paper presents the development of an FPGA-based logic controller (FLC) and a diverse protection system (DPS) with the FLC platform. Protection functions for the DPS were implemented in FPGAs without any CPU or OS. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

TRAM v. 1.1 Alpha

TRAM is the Technology Refreshment Assessment Model, a computer software application that provides analysts and executives with the ability to perform optimal Technology Management decision making over the life-cycle of a technologically sophisticated, high value system or system-of-systems. The tool allows for the development of optimal technology management strategies and technology roadmaps over long-term time horizons, factoring in performance, cost, schedule, risk and obsolescence.

EDDY, JOHN↗

Technical Specification Surveillance Interval Extension of Digital Equipment in Nuclear Power Plants: Review and Research. Light Water Reactor Sustainability Program report

The nuclear industry has been slow to incorporate digital technology into nuclear plant designs for several reasons, including: The high cost of design change modifications to implement them, versus simply replacing them with like for like technology when the components fail; Digital technology qualification issues, particularly in safety related applications that are susceptible to software common cause failure. This is a concern both for current operating plants as well as new builds; and, General familiarity and comfort with the existing analog technology on the part of the nuclear plant engineering staff, in spite of the superior performance and reduced maintenance costs of the digital replacements. At the same time, the nuclear industry is under significant cost pressure in the electric marketplace due to the abundance of natural gas generation and renewables. The industry would benefit by investment in new technologies that could lower future operating costs while addressing obsolescence and reliability issues of the current analog technologies. However, the industry has been unable to formulate the business cases to take advantage of these labor savings and production reliability improvements. This paper discusses another potential cost savings benefit of a transition to digital technology, extending the surveillance intervals of technical specification required equipment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of quantitative methods for reliability testing of a nuclear power plant digital rod position indication diagnostic system - 391

Obsolescence, aging, reliability, and performance issues are driving nuclear facilities to replace conventional analog Instrumentation and Control (I and C) systems with digital technologies. In addition, the designs of the next generation of nuclear reactors, including Small Modular Reactors (SMRs), will incorporate digital I and C for most, if not all, of their safety and non-safety related functions. As part of an on-going research and development (R and D) effort under the auspices of the U.S. Department of Energy (DOE), Analysis and Measurement Services Corporation (AMS) is developing a platform to provide automated testing of digital I and C systems and create a standard method of evaluation for reliability assessments. This hands-on R and D effort has produced a Software Reliability Tester (SRT), which is a set of software and hardware tools designed to automate the testing of digital I and C systems to measure and quantify how well the systems perform under normal operating conditions and in the presence of faults. Furthermore, the SRT provides the foundation for a practical tool to automate verification and validation (V and V) activities and reduce the amount of testing time of digital I and C systems. When combined with its capabilities of integrating both reliability and fault tolerance quantification, the SRT can be used to ensure that digital I and C implementations are both safe and cost-effective for the nuclear industry. This paper describes the application of the SRT to perform V and V of a new Digital Rod Position Indication (DRPI) diagnostic system. The DRPI diagnostic system is a digital system that monitors the rod address and rod position data bus voltages of typical DRPI systems in nuclear power plants to detect and diagnose faults. For this application, the SRT was configured to exercise the inputs of the DRPI diagnostic system, and test cases were generated for common system faults such as address and data bit errors, bus voltage, and timing problems. These test cases were applied by the SRT hardware as voltage inputs to the DRPI diagnostic system and the outputs were compared to expected values generated by a model of the DRPI diagnostic system. Included in the paper is a description of the overall design of the SRT including the hardware and software architectures. Methodologies for automating test cases are also described. V and V using the SRT demonstrates the benefits of automated testing and qualification to provide a quantitative assessment of reliability and cost effective implementation of digital I and C in existing and next generation nuclear power plants. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗