Search NASA⌕ Search

SEARCH · Search NASA

Results for “solar siting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Solar site test module

A solar site test module using the Rockwell AIM 65microcomputer is described. The module is designed to work at any site where an IBM site data acquisition system (SDAS) is installed and is intended primarily as a troubleshooting tool. It collects sensor information (temperatures, flow rates, etc.) and displays or prints it immediately in calibrated engineering units. It will read one sensor on demand, periodically read up to 10sensors or periodically read all sensors. Performance calculations can also be included with sensor data. Unattended operation is possible to, e.g., monitor a group of sensors once per hour. Work is underway to add a data acquisition system to the test module so that it can be used at sites which have no SDAS.

Kissel, R. R.↗

Solar-site test module

Report describes small test set which interrogates solar-energy data acquisition systems. Lightweight, portable set includes microcomputer with keyboard, alphanumeric display, printer, cassette recorder/player for storing programs and data, and cable for connection to Site Data Acquisition System (SDAS). Unit is operated by BASIC program and Assembly language. Report is specific to DOE/NASA application yet contains general information to assist in designing similar units.

Kissel, R. R.↗

Siting solar thermal power experiments

The Small Community Solar Thermal Power Experiment will test a point-focusing, distributed receiver system in a small community, electric utility application. Site planning is becoming increasingly important for solar experiments as well as all kinds of development due to increased competition for desirable sites and increased complexity of regulatory requirements. Siting issues can be categorized as: (1) resources and physical environmental at this site; (2) acquisition, permits and regulations; and (3) development requirements and costs. These issues are addressed with respect to the unique requirements of solar thermal power experiments.

Holbeck, H. J.↗

Georgia Energy III Project Summary - Identifying Habitat and Solar Site Conflict in Georgia by Developing an Environmental Sensitivity Public Mapping Too

The rapid expansion of the solar industry across the state of Georgia has a detrimental effect on the habitats of keystone and threatened species, such as the gopher tortoise (Gopherus polyphemus) and the American black bear (Ursus americanus). NASA DEVELOP collaborated with the Georgia Chapter of The Nature Conservancy (TNC) and the Georgia Department of Natural Resources to continue the research from two previous NASA DEVELOP projects in 2017. The team worked to assess the conflict between solar suitability and environmentally sensitive areas with the Land-Use Conflict Identification Strategy (LUCIS) and to determine how conflict has changed since the 2017 analysis. The project utilized Terra/Aqua Clouds and the Earth's Radiant Energy System (CERES) satellite data and other ancillary datasets to conduct and compare a general statewide LUCIS analysis from 2017 to 2019 and to complete an in-depth LUCIS analysis of Georgia’s fastest-growing solar counties—Taylor, Twiggs, Decatur, and Brooks. The analysis indicated that between 2017 and 2019, the entire state saw high conflict areas increase by 38%. Project partners will use these findings to target areas for promotion of conservation policy and education efforts. The team also provided the TNC with a publicly available web application, called the Environmental Sensitivity Mapping Tool (ESMT), that can be updated as new data are released. The ESMT will be used to educate interest groups, such as solar developers and conservationists, to help them recognize and mitigate the negative effects of solar development on the environment.

DEVELOP Project Summary↗

Subsystem design package for the on-site monitor at solar heating and cooling sites

The on-site monitor is a portable device which can be easily connected to a Site Data Acquisition Subsystem to allow readouts of realtime sensor data in voltage or engineering units at instrumented solar heating and cooling sites. The design package consists of the performance specification, performance requirements cross reference, and the acceptance test procedure.

Source record↗

Three computer codes to read, plot and tabulate operational test-site recorded solar data

Computer programs used to process data that will be used in the evaluation of collector efficiency and solar system performance are described. The program, TAPFIL, reads data from an IBM 360 tape containing information (insolation, flowrates, temperatures, etc.) from 48 operational solar heating and cooling test sites. Two other programs, CHPLOT and WRTCNL, plot and tabulate the data from the direct access, unformatted TAPFIL file. The methodology of the programs, their inputs, and their outputs are described.

Stewart, S. D.↗

Determination of potential solar power sites in the United States based upon satellite cloud observations

The use of cloud images in the visual spectrum from the SMS/GOES geostationary satellites to determine the hourly distribution of sunshine on a mesoscale in the continental United States excluding Alaska is presented. Cloud coverage and density as a function of time of day and season are evaluated through the use of digital data processing techniques. Low density cirrus clouds are less detrimental to solar energy collection than other types; and clouds in the morning and evening are less detrimental than those during midday hours of maximum insolation. Seasonal geographic distributions of cloud cover/sunshine are converted to langleys of solar radiation received at the earth's surface through relationships developed from long term measurements at six widely distributed stations.

Hiser, H. W.↗

A THEMIS Survey of Flux Ropes and Traveling Compression Regions: Location of the Near-Earth Reconnection Site During Solar Minimum

A statistical study of flux ropes and traveling compression regions (TCRs) during the Time History of Events and Macroscale Interactions during Substorms (THEMIS) second tail season has been performed. A combined total of 135 flux ropes and TCRs in the range GSM X approx -14 to -31 R(sub E) were identified, many of these occurring in series of two or more events separated by a few tens of seconds. Those occurring within 10 min of each other were combined into aggregated reconnection events. For the purposes of this survey, these are most likely the products of reconnect ion occurring simultaneously at multiple, closely spaced x-lines as opposed to statistically independent episodes of reconnection. The 135 flux ropes and TCRs were grouped into 87 reconnection events; of these, 28 were moving tailward and 59 were moving Earthward. The average location of the near-Earth x-line determined from statistical analysis of these reconnection events is (X(sub GSM), Y*(sub GSM)) = (-30R(sub E), 5R(sub E)), where Y* includes a correction for the solar aberration angle. A strong east-west asymmetry is present in the tailward events, with >80% being observed at GSM Y* > O. Our results indicate that the Earthward flows are similarly asymmetric in the midtail region, becoming more symmetric inside - 18 R(sub E). Superposed epoch analyses indicate that the occurrence of reconnection closer to the Earth, i.e., X > -20 R(sub E), is associated with elevated solar wind velocity and enhanced negative interplanetary magnetic field B(sub z). Reconnection events taking place closer to the Earth are also far more effective in producing geomagnetic activity, judged by the AL index, than reconnection initiated beyond X approx -25 R(sub E).

Imber, S. M.↗

Operations manual: On Site Monitor (OSM), solar heating and cooling systems

The on-site monitor is a portable device which, when connected to a solar system site data acquisition subsystem; allows readouts of clock and sensor data in voltage or engineering units at instrumented solar heating and cooling sites. The unit is described and procedures for its proper operation are presented.

Source record↗

The IRIS network site at the Wilcox Solar Observatory

The site for the International Research on the Interior of the Sun (IRIS) instrument housed at the Wilcox Solar Observatory at Stanford University (near San Francisco, USA) is described together with the instrument operation procedure. The IRIS instrument, which measures global oscillations of the sun, operates continuously every clear day since it was installed in August 1987.

Hoeksema, J. T.↗

Modifications and testing of a 4-95 Stirling engine for solar applications

The modifications and testing of a standard Stirling engine, required for connection to a 25 kW induction alternator, for use with a solar thermal parabolic dish electric module is described. Power was absorbed by a GE induction alternator connected to the utility grid. Also included are the results from recent testing of another solar engine at the DOE-Georgia Tech solar site. It was done in parallel with the testing at Edwards for the purpose of comparing performance of two solar-only receivers, which were based on the standard 4-95 involute heat exchanger.

Nelving, H. G.↗

Thermal power systems small power systems application project: Siting issues for solar thermal power plants with small community applications

The siting issues associated with small, dispersed solar thermal power plants for utility/small community applications of less than 10 MWe are reported. Some specific requirements are refered to the first engineering experiment for the Small Power Systems Applications (SPSA) Project. The background for the subsequent issue discussions is provided. The SPSA Project and the requirements for the first engineering experiment are described, and the objectives and scope for the report as a whole. A overview of solar thermal technologies and some technology options are discussed.

Holbeck, H. J.↗

Lunar surface solar wind observations at the Apollo 12 and Apollo 15 sites

The solar wind-lunar magnetic field interaction is examined by comparing Apollo 12 and Apollo 15 solar wind spectrometric data. The instrumentation and data analysis methods are described along with the observations at the Apollo 15 site, and the data from the two sites are compared. The results show no noticeable differences between the properties of the upstream solar wind and the plasma observed at the Apollo 15 site (where the local magnetic field is relatively weak) and strong perturbations in the solar wind at the Apollo 12 site (where the field is relatively strong), which include deceleration, deflection, and heating of solar wind protons, focusing or defocusing of the ion flux, and an increased level of plasma parameter fluctuations. These effects are shown to require a charge-separated electric field above the lunar surface and a scale size of about 5 km for the local magnetic field at the Apollo 12 site and to suggest that local lunar magnetic field regions cause lunar limb compression waves which should be more noticeable for low solar wind dynamic pressures.

Clay, D. R.↗

Validation of the solar heating and cooling high speed performance (HISPER) computer code

Developed to give a quick and accurate predictions HISPER, a simplification of the TRNSYS program, achieves its computational speed by not simulating detailed system operations or performing detailed load computations. In order to validate the HISPER computer for air systems the simulation was compared to the actual performance of an operational test site. Solar insolation, ambient temperature, water usage rate, and water main temperatures from the data tapes for an office building in Huntsville, Alabama were used as input. The HISPER program was found to predict the heating loads and solar fraction of the loads with errors of less than ten percent. Good correlation was found on both a seasonal basis and a monthly basis. Several parameters (such as infiltration rate and the outside ambient temperature above which heating is not required) were found to require careful selection for accurate simulation.

Wallace, D. B.↗