Failure Analysis of Solder Joints
Soldering is a critical filler material joining process found in nearly all modern electronics. Ensuring solder joint reliability is crucial for the safety, performance, and cost-effectiveness of microelectronics.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Soldering is a critical filler material joining process found in nearly all modern electronics. Ensuring solder joint reliability is crucial for the safety, performance, and cost-effectiveness of microelectronics.
Tin-lead-antimony (50Sn–47Pb–3Sb wt.%) soldered assemblies were mechanically tested approximately 30 years after initial production and found to have solder joints of reduced strength. The microstructure of this solder alloy exhibits a ternary eutectic structure with Sn-rich, Pb-rich, and SnSb phases. Accelerated aging was performed to evaluate solder microstructural coarsening and associated strength of laboratory solder joints to correlate these properties to the “naturally aged” solder joints. Isothermal aging was conducted at room temperature, 55, 70, 100, and 135 °C and aging times that ranged from 0.1 to 365 days. The coarsening kinetics of the Pb-rich phase were determined through optical microscopy and image analysis methods established in previous studies on binary Sn–Pb solder. A kinetic equation was developed with time exponent n of 0.43 and activation energy of 24000 J/mol, suggesting grain boundary diffusion or other fast diffusion pathways controlling the microstructural evolution. Compression testing and Vickers microhardness showed significant strength loss within the first 20–30 days after soldering; then, the microstructure and mechanical properties changed more slowly over long periods of time. Further, by combining accelerated aging data and the microstructure-based kinetics, strength predictions were made that match well with the properties of the actual soldered assemblies naturally aged for 30 years. However, aging at the highest temperature of 135 °C produced anomalous behavior suggesting that extraneous aging mechanisms are active. Therefore, data obtained at this temperature or higher should not be used. Overall, the combined microstructural and mechanical property methods used in this study confirmed that the observed reduction in strength of ~ 30-year-old solder joints can be accounted for by the microstructural coarsening that takes place during long-term solid-state aging.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
This thesis studies drop durability of electronic assemblies when the acceleration vector is oriented at 45° to the out-of-plane direction of the circuit card. The off-axis drop tests are accomplished with a skewed fixture and are conducted as a proxy for multiaxial drop testing. Advanced shock testing and vibration test methods have been developed over the last few decades to better represent real-world field environments during ground-based laboratory testing. However, many of these test methods require expensive and specialized equipment not available in most laboratories. An alternative approach for approximating simultaneous loading along multiple axes on conventional equipment utilizes skewed fixtures which have seen use in off-axis random vibration and drop impact testing. These methods generally rely on the conversion of a uniaxial input load from the test equipment (using a uniaxial drop tower or shaker) into a multiaxial load when resolved in the reference frame of the test article (mounted on a skewed fixture). Skewed fixture design is presented and recommendations for conducting skewed angle drop testing are introduced based on local measurements along the skewed face of the fixture to accurately monitor the impact event. Characterization tests were performed with a skewed fixture, at simultaneous acceleration loads from 500 to 3,000 g in two (in-plane and out-of-plane) directions, while meeting standard time domain tolerances. Upon experimental characterization, drop shock durability tests were conducted on a printed circuit assembly (PCA). Mean drops-to-failure were measured and quantified with Weibull statistics. Dominant solder joint failure modes were identified via failure analysis. Prior work on inclined angle impact testing is limited, and the majority of solder joint interconnect level fatigue studies are conducted considering perpendicular loading normal the circuit card. Low-cycle fatigue curves are generated based on plastic strain and plastic work density within the solder joint. A multiscale nonlinear finite element model is used to relate board-level flexure to solder joint interconnect level plastic strain. A high strain rate solder constitutive model allows for accurate modeling of solder plasticity resulting from high-impact drop shock. Fatigue parameters are computed from the Coffin-Manson relation and Palmgren-Miner damage accumulation. This work serves to apply established low-cycle fatigue methods for conventional drop shock loading (impact normal to circuit card) to non-perpendicular loading with a skewed fixture.
Eutectic alloys, such as Pb-free Bi-Sn-Ag or Sn-Ag-Cu, are essential for their low melting points in solder joints but suffer from brittle intermetallic phases, reducing reliability. Traditional solder design relies on equilibrium phase diagrams, often neglecting the kinetic influence of crystalline anisotropy during solidification. This study hypothesizes that the energetics at the solid-solid-liquid trijunction dictate crystalline facet selection. Using the Al-Al 3 Ni alloy as a model, this project combines atomistic simulations and experimental methods to understand interfacial energies and develop predictive models. This approach aims to mitigate the negative effects of intermetallics, enhancing component reliability in electronic applications.
Brazing and soldering are metallurgical joining techniques that use a wetting molten metal to create a joint between two faying surfaces. Here, the quality of the brazing process depends strongly on the wetting properties of the molten filler metal, namely the surface tension and contact angle, and the resulting joint can be susceptible to various defects, such as run-out and underfill, if the material properties or joining conditions are not suitable. In this work, we implement a finite element simulation to predict the formation of such defects in braze processes. This model incorporates both fluid–structure interaction through an arbitrary Eulerian–Lagrangian technique and free surface wetting through conformal decomposition finite element modeling. Upon validating our numerical simulations against experimental run-out studies on a silver-Kovar system, we then use the model to predict run-out and underfill in systems with variable surface tension, contact angles, and applied pressure. Finally, we consider variable joint/surface geometries and show how different geometrical configurations can help to mitigate run-out. This work aims to understand how brazing defects arise and validate a coupled wetting and fluid–structure interaction simulation that can be used for other industrial problems.
MARCO will be a superconducting solenoid for a new particle physics detector of the upcoming Electron Ion Collider (EIC) at Brookhaven National Laboratory (NY, USA). The design field at the interaction point is 2.0 T with a nominal current of about 4 kA at 4.5 K. For this magnet, an aluminumstabilized conductor was considered at the very preliminary design phase. After that, since the lack of manufacturers able to deal with aluminum extrusion, copper has been chosen as stabilizer. Thanks to a dedicated design effort, the copper stabilizer and accompanying material choices provided acceptable hadronic interaction length. The conductor is based on a NbTi Rutherford cable that is soldered in a U-shaped copper profile. Here, this paper goes through the definition of the conductor crosssection according to the project requirements and the supplier capabilities. Its characteristics will be detailed and discussed, in particular the RRR and the yield strength of the copper channel needed for protection and mechanics respectively. Finally, a proposal on how to make the joint between two conductors is presented.
Abstract A low AC loss Rare Earth Barium Copper Oxide (REBCO) cable, based on the VIPER cable technology has been developed by Commonwealth Fusion Systems for use in high field, REBCO based tokamaks. The new cable is composed of partitioned and transposed copper ‘petals’ shaped to fit together in a circular pattern with each petal containing a REBCO tape stack and insulated from each other to reduce AC losses. A stainless steel jacket adds mechanical robustness—also serving as a vessel for solder impregnation—while a tube runs through the middle for cooling purposes. Additionally, fiber optic sensors are placed under the tape stacks for quench detection. To qualify this design, a series of experiments were conducted as part of the SPARC tokamak Central Solenoid Model Coil program—to retire the risks associated with full scale, fast ramping, high flux HTS Central Solenoid (CS) and Poloidal Field (PF) coils for tokamak fusion power plants and net energy demonstrators. These risk study and risk reduction experiments include (1) AC loss measurement and model validation in the range of ~5 T/s, (2) an IxB electromagnetic loading of over 850 kN/m at the cable level and up to 300 kN/m at the stack level, (3) a transverse compression resilience of over 350 MPa, (4) manufacturability at tokamak relevant speeds and scales, (5) cable to cable joint performance, (6) fiber optic based quench detection speed, accuracy, and feasibility, and (7) overall winding pack integration and magnet assembly. The result is a cable technology, now referred to as PIT VIPER, with AC losses that measure fifteen times lower (at ~5 T/s) than its predecessor technology; a 2% or lower degradation of critical current (Ic) at high IxB electromagnetic loads; no detectable Ic degradation up to 570 MPa of transverse compression on the cable unit cell; end to end magnet manufacturing, consistently producing Ic values within 7% of the model prediction; cable to cable joint resistances at 20 K on the order of ~15 nΩ; and fast, functional quench detection capabilities that do not involve voltage taps. This cable technology will be tested comprehensively in a Central Solenoid Model Coil to prove its readiness for compact, high field tokamak operation.