Search NASA⌕ Search

SEARCH · Search NASA

Results for “solenoid-free plasma current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Improvements to the High-Field-Side Transient CHI System on QUEST

Transient coaxial helicity injection (CHI) is a promising candidate for solenoid-free plasma current start-up in a low-aspect-ratio tokamak in support of developing fully non-inductive scenarios. The aim of the transient CHI research on QUEST is to develop a reactor-relevant CHI design. On QUEST, a CHI discharge is initiated by driving current along magnetic field lines that connect an electrically insulated electrode plate (which is referred to as a bias electrode) to a vessel component at the bottom region of the spherical tokamak. In the first application of CHI on QUEST, the electrically insulated electrode plate was biased with respect to the outer vessel in a configuration referred to as low-field-side (LFS) injection. To maintain a narrow injector flux footprint width throughout the discharge, QUEST is now developing a high-field-side (HFS) injection configuration, in which the electrically insulated electrode plate is biased with respect to the inner vessel components. Through the implementation of a CHI-dedicated gas injection system, studies in the HFS injection configuration have now demonstrated good magnetic flux evolution into the vacuum vessel. Toroidal currents up to 43 kA have been achieved, and the generated current has increased in proportion to the magnetic flux connecting the electrodes. Finally, these results which show agreement with the CHI-scaling suggest that much higher levels of toroidal current can be generated on QUEST in an optimized CHI system in which the magnetic flux connecting the CHI electrodes is further increased.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

$\mathrm{T}$ransient $\mathrm{CHI}$ System Design Studies for $\mathrm{P}$ EGASUS -$\mathrm{III}$

We report transient coaxial helicity injection (transient CHI), first developed on the Helicity Injected Torus-II (HIT-II) and later on the National Spherical Torus Experiment (NSTX) for implementing solenoid-free plasma current startup capability in a spherical tokamak (ST), is now planned to be tested on the Pegasus-III ST using a novel double-biased configuration. Such a configuration is likely needed for transient CHI deployment in a reactor. The transient CHI system optimization will be studied on Pegasus-III to enable startup toroidal persisting currents at the limits permitted by the external poloidal field coils. A transient CHI discharge is generated by driving injector current along magnetic field lines that connect the inner and outer divertor plates on one end of the ST. Simulations using the Tokamak Simulation Code are used to assess the transient CHI toroidal current generation potential and electrode gap location on the Pegasus-III. While past transient CHI systems have used high-voltage, oil-filled capacitors for driving the injector current, for improved safety, Pegasus-III will use a high-current capacitor bank based on low-voltage electrolytic capacitors. The designed and fabricated system is capable of over 32 kA. The modular design features permit the system to be upgraded to higher currents, as needed, to meet the future needs of the Pegasus-III facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design considerations for optimizing the transient CHI injector on QUEST

Transient coaxial helicity injection (transient CHI) on the QUEST (Q-shu University Experiment with Steady-State ST) spherical tokamak (ST) has recently validated the floating biased electrode configuration for solenoid-free plasma startup. In support of a significant divertor upgrade on QUEST, the details of the transient CHI injector geometry on QUEST have been examined more closely using tokamak simulation code (TSC) simulations. QUEST uses a HIT-II-like (Helicity Injected Torus) injector configuration in which the injector region is comprised of coaxial injector electrodes located in the lower part of the machine. TSC simulations indicate high injector flux operation may benefit from an increased gap between the coaxial electrodes. This is the first study to examine the differences between an open and closed electrode configuration for solenoid-free plasma startup using transient CHI. Results show that both configurations can generate similar levels of closed flux, but the closed configuration may be easier to implement in some ST designs as a much smaller portion of the injector needs to be close to the injector flux coil. Results show that increasing the electrode gap width from the present 10.8 cm to about 15–20 cm would increase the closed flux fraction by about 40%. The results presented in this paper are generally applicable to the CHI design for other STs.

coaxial helicity injection↗

Modeling of injected current stream-induced 3D perturbations in local helicity injection plasmas

Solenoid-free tokamak startup techniques are essential for spherical tokamaks and offer a pathway to cost reduction and design simplification in fusion energy systems. Local helicity injection (LHI) is one such approach, employing compact edge current sources to drive open field line current that initiates and sustains tokamak plasmas. The recently commissioned Pegasus-III Experiment provides a platform for advancing this and other solenoid-free startup methods. This study investigates the effect of LHI on magnetic topology in Pegasus-III plasmas. A helical filament model represents the injected current, and the linear plasma response to its three-dimensional field is calculated with M3D-C1. Poincaré mapping reveals substantial flux surface degradation in all modeled cases. The onset of overlapping magnetic structures and large-scale surface deformation begins near Ψ N ≈ 0.37, indicating a broad region of perturbed topology extending toward the edge. In rotating plasmas, both single-fluid and two-fluid models exhibit partial screening of the n = 1 perturbation, with two-fluid calculations showing stronger suppression near the edge. In contrast, the absence of rotation leads to strong resonant field amplification in the single-fluid case, while the two-fluid case with zero electron rotation mitigates this amplification and preserves edge screening. Magnetic probe measurements indicate that modeling the stream with spatial spreading—representing distributed current and/or oscillatory motion—better reproduces measured magnetic power profiles than a rigid filament model. The results underscore the role of rotation and two-fluid physics in screening stream perturbations and point to plasma flow measurements and refined stream models as key steps toward improving predictive fidelity.

Schaefer, Carolyn E. [Univ. of Wisconsin, Madison,↗

Efficient electron cyclotron current drive regime for plasma current start-up in fusion reactors

We report an accessibility enhanced efficient fundamental X-mode electron cyclotron heating (ECH) current start-up regime was identified for a reactorlike toroidal magnetic field range which has more than 100 times higher current drive efficiency compared to more conventional ECH methods for the relevant start-up temperature range. Very high current drive efficiency is possible due to the strong cyclotron interaction only with unidirectional passing electrons constrained by the wave accessibility conditions. This efficient electron cyclotron current drive regime may help facilitate the design of innovative economical solenoid-free tokamak fusion reactor systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of transient CHI startup using a floating biased electrode configuration

Abstract Results from the successful solenoid-free plasma startup using the method of transient coaxial helicity injection (transient CHI) in the QUEST spherical tokamak (ST) are reported. Unlike previous applications of CHI on HIT-II and on NSTX which required two toroidal insulating breaks to the vacuum vessel, QUEST uses a first of its kind, floating single biased electrode configuration, which does not use such a vacuum break. Instead, the CHI electrode is simply insulated from the outer lower divertor plate support structure. This configuration is much more suitable for implementation in a fusion reactor than the previous configurations. Transient CHI generated toroidal currents of 135 kA were obtained. The toroidal current during the formation of a closed flux configuration was over 50 kA. These results bode well for the application of transient CHI in a new generation of compact high-field STs and tokamaks in which the space for the central solenoid is very restricted.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Efficient ECCD non-inductive plasma current start-up, ramp-up, and sustainment for an ST fusion reactor

The elimination of the need for an Ohmic heating solenoid may be the most impactful design driver for the realization of economical compact fusion tokamak reactor systems. However, this would require fully non-inductive start-up and current ramp-up from zero plasma current and low electron temperature of sub-keV to the full plasma current of ~10–15 MA at 20–30 keV electron temperature. To address this challenge, an efficient solenoid-free start-up and ramp-up scenario utilizing a low-field-side-launched extraordinary mode at the fundamental electron cyclotron harmonic frequency (X–I) is proposed, which has more than two orders of magnitude higher electron cyclotron current drive (ECCD) efficiency than the conventional ECCD for the sub-keV start-up regime. A time dependent model was developed to simulate the start-up scenarios. For the Spherical Tokamak Advanced Reactor (STAR) (Menard et al 2023 Next-Step Low-Aspect-Ratio Tokamak Design Studies (IAEA)), it was found that to fully non-inductively ramp-up to 15 MA, it would take about 25 MW of EC power at 170 GHz. Because of the relatively large plasma volume of STAR, radiation losses must be considered. It is important to make sure that high Z impurities are kept sufficiently low during the early current start-up phase where the temperature is sub-keV range. Since the initial current ramp up takes place at a factor of ten lower density compared to the sustained regimes, it is important to transition into a higher bootstrap fraction discharge at lower density to minimize the ECCD power requirement during the densification. For the sustainment phase an array of eight gyrotron launchers with a total of about 60 MW of fundamental O-mode was found to be sufficient to provide the required axis-peaked external current drive. High efficiencies between 19–57 kA MW –1 were found with optimal aiming, and these were resilient to small changes in aiming angles and density and temperature profiles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Taylor limit studies for local helicity injection plasma startup

Solenoid-free tokamak startup techniques can simplify the design and reduce the cost of tokamak-based fusion energy systems. The newly commissioned Pegasus-III spherical tokamak provides a dedicated platform for developing a scalable solenoid-free startup approach. Local helicity injection (LHI) is one promising technique being developed on Pegasus-III, which uses compact edge current sources to drive open field line current I inj that is redistributed via helicity-conserving instabilities to initiate tokamak plasmas. These instabilities relax the system toward a minimum energy state described by Taylor relaxation theory. This relaxation process imposes a global current limit for LHI plasmas, referred to as the Taylor limit I TL ⁠, which can dictate the plasma current I p evolution. Experiments on Pegasus and Pegasus-III show that increasing this limit leads to more effective utilization of the available helicity input and higher I p plasmas. Initial Pegasus-III experiments have verified the expected I TL $\varpropto$ ( I inj B T ) 1/2 scaling holds for B T and I inj up to 0.3 T on axis and 12 kA ⁠, respectively. Additionally, data from different injector arrays show that the width of the injector aperture directly alters I TL and can be leveraged for future injector design optimization. Throughout these scaling studies, discharges were overdriven at I p = I TL by providing excess helicity input. Intermittent bursts of n = 1 magnetic activity consistent with large-scale reconnection events occurred more often as the system was increasingly overdriven leading to a flattening of the λ = μ 0 J ∥ / |B| profile, where J ∥ is the parallel current density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overview of recent results from the ST40 compact high-field spherical tokamak

ST40 is a compact, high-field ($B_{\mathrm{T0}}\unicode{x2A7D} 2.1\,\,\,\textrm{T}$) spherical tokamak (ST) with a mission to expand the physics and technology basis for the ST route to commercial fusion. The ST40 research programme covers confinement and stability; solenoid-free start-up; high-performance operating scenarios; and plasma exhaust. In 2022, ST40 obtained central deuterium ion temperatures of $9.6 \pm 0.4\ \textrm{keV}$, demonstrating for the first time that pilot plant relevant ion temperatures can be reached in a compact, high-field ST. Analysis of these high-ion temperature plasmas is presented, including a summary of confinement, transport and microstability characteristics, and energetic particle instabilities. Recent scenario development activities have focused on establishing diverted H-mode plasmas across a range of toroidal fields and plasma currents, along with scenarios with high non-inductive current fractions. In future operations, beginning in 2025, a 1 MW dual frequency (104/137 GHz) electron cyclotron (EC) system will be installed to enable the study of EC and electron Bernstein wave plasma start-up and current drive. Predictive modelling of the potential performance of these systems is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of Injected Current Streams on MHD Equilibrium Reconstruction of Local Helicity Injection Plasmas in a Spherical Tokamak

Open field line currents are intrinsic to DC helicity injection plasma startup and pose a challenge for inferring the plasma equilibrium with standard reconstruction analysis. Local helicity injection (LHI) is a type of DC helicity injection which uses small, modular current sources to drive force-free current along helical field lines to produce tokamak plasmas. MHD modeling and magnetic measurements during LHI indicate the injected current streams remain coherent as helical structures on the outboard edge of a core toroidal plasma that is tokamak-like in a toroidally averaged sense. To extract core plasma equilibrium properties, external magnetic diagnostics corrected for contributions from the injected current streams are fitted by a standard Grad-Shafranov equilibrium code. An iterative approach for estimating and subtracting the stream contributions from the diagnostic signals is described and applied to a model equilibrium database to reduce systematic errors introduced by the streams. Convergence is usually attained with 2 to 4 iterations, with derived equilibrium parameters matching the prescribed axisymmetric core values to within estimated experimental uncertainties. Accurate recovery of core parameters occurs when the ratio of the net toroidal windup current from the streams to the core plasma current is less than 0.2, which is typically satisfied in most experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Public Data Set: Effects of Injected Current Streams on MHD Equilibrium Reconstruction of Local Helicity Injection Plasmas in a Spherical Tokamak

This public data set contains openly-documented, machine readable digital research data corresponding to figures published in J.D. Weberski et al., 'Effects of Injected Current Streams on MHD Equilibrium Reconstruction of Local Helicity Injection Plasmas in a Spherical Tokamak,' Journal of Fusion Energy 43, 72 (2024).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A magnetic diagnostic suite for the Pegasus-III experiment

Pegasus-III is an ultralow aspect ratio spherical tokamak providing a dedicated US experiment for comparative solenoid-free startup studies. A new magnetic diagnostic suite for equilibrium and low frequency (<200 kHz) magnetohydrodynamic mode analysis has been installed. These new diagnostics address the significant challenges of measuring magnetic field in a high noise environment with the majority constrained to fit in an 8 mm diagnostic gap on the high field side. Electrostatic switching noise generated by the 16 independent current feedback-controlled power supplies produces dV cm /dt ~ 1 kV/μs and volt level common mode noise on the magnetics. Immunity to this switching noise is accomplished through differential signal runs and signal processing, along with end-to-end electromagnetic interference shielding. The magnetic measurements are simultaneously digitized at 1 MHz and conditioned by precision 8 pole Butterworth filters with a corner frequency of 200 kHz to prevent aliasing down to the 16-bit level over the full passband. Ex-vessel calibrations of the B p coils were completed with a typical uncertainty of <0.5%. Stray toroidal field pickup from coil misalignment or positioning errors is corrected using a physics-based model. Comparisons of the corrected measurements to modeling agree to within 1.3% on average. This is within the 1.5% measurement uncertainty that a sensitivity analysis determined is needed for accurate fast boundary and equilibrium reconstruction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗