Search NASA⌕ Search

SEARCH · Search NASA

Results for “solenoidal spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Tritium targets for use in solenoidal spectrometers

Nucleon adding and removing reactions are an ideal probe to study the single-particle foundations of nuclear structure. For experiments far away from the valley of stability, one needs to use radioactive beams in inverse kinematics. To maintain excellent resolution, solenoidal spectrometers like HELIOS at Argonne National Laboratory (ANL), ISS at CERN or SOLARIS at the Facility for Rare Isotope Beams (FRIB) are used. Typically, deuterated plastic foils are the targets of choice. Depending on the energy deposited, these targets might degrade quickly in beam. The potential of using tritium-implanted targets in conjunction with the solenoidal spectrometers was realized for access to even more exotic nuclei with outstanding resolving power. While no tritiated polyethylene is commercially available at the moment, tritium-containing titanium targets have been produced in the past. Unfortunately the loading fraction of tritium for the latter was often very low and not reproducible. The progress in the production of tritium-containing targets is presented, including the characterization of the foils.

Müller-Gatermann, Claus↗

Kinematics reconstruction in solenoidal spectrometers operated in active target mode

Here, we discuss the reconstruction of low-energy nuclear reaction kinematics from charged-particle tracks in solenoidal spectrometers working in Active Target Time Projection Chamber mode. In this operation mode, reaction products are tracked within the active gas medium of the Active Target with a three dimensional space point cloud. We have inferred the reaction kinematics from the point cloud using an algorithm based on a linear quadratic estimator (Kalman filter). The performance of this algorithm has been evaluated using experimental data from nuclear reactions measured with the Active Target Time Projection Chamber (AT-TPC) detector.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of the galactic cosmic ray and geomagnetic transmission models

A very high-momentum resolution particle spectrometer called the Alpha Magnetic Spectrometer (AMS) was flown in the payload bay of the Space Shuttle in a 51.65 degrees x 380-km orbit during the last solar minimum. This spectrometer has provided the first high statistics data set for galactic cosmic radiation protons, and helium, as well as limited spectral data on carbon and oxygen nuclei in the International Space Station orbit. First measurements of the albedo protons at this inclination were also made. Because of the high-momentum resolution and high statistics, the data can be separated as a function of magnetic latitude. A related investigation, the balloon borne experiment with a superconducting solenoid spectrometer (BESS), has been flown from Lynn Lake, Canada and has also provided excellent high-resolution data on protons and helium. These two data sets have been used here to study the validity of two galactic cosmic ray models and the geomagnetic transmission function developed from the 1990 geomagnetic reference field model. The predictions of both the CREME96 and NASA/JSC models are in good agreement with the AMS data. The shape of the AMS measured albedo proton spectrum, up to 2 GeV, is in excellent agreement with the previous balloon and satellite observations. A new LIS spectrum was developed that is consistent with both previous and new BESS 3He observations. Because the astronaut radiation exposures onboard ISS will be highest around the time of the solar minimum, these AMS measurements and these models provide important benchmarks for future radiation studies. AMS-02 slated for launch in September 2003, will provide even better momentum resolution and higher statistics data. Published by Elsevier Science Ltd.

unmanned↗

𝑁 = 8 Shell Breaking in 12 Be from a Single-Particle Perspective

Experimental observations of the low-lying states in 12 Be and their accurate modeling play an essential role in understanding the disappearance of the 𝑁 = 8 magic number. Long-standing experimental ambiguities have been clarified using an one-neutron adding (𝑑, 𝑝) reaction on 11 Be using the ISOLDE Solenoidal Spectrometer at CERN’s HIE-ISOLDE facility. The single-particle energies of 1⁢𝑠 1/2 , 0⁢𝑑 5/2 , and 0⁢𝑝 1/2 orbitals in 12 Be have been determined from the extracted spectroscopic factors. A significant reduction between the separation of 1⁢𝑠 1/2 and 0⁢𝑝 1/2 orbitals is found in comparison with the carbon isotones, highlighting the breakdown of the 𝑁 = 8 shell. These observations serve as an important test of different effects incorporated in theoretical models. It is found that two synergistic mechanisms, core deformation and weak binding, are responsible for the 𝑁 = 8 shell breaking and the exotic near-threshold phenomena observed in 12 Be, including the narrow unnatural-parity resonance $0^{-}_1$ and the possible halolike nature of the $0^+_2$ isomer.

Chen, Jie [Southern University of Science and Tech↗

Study of multiple cycles valves

A discussion is presented regarding valves which can be cycled repeatedly and are available from industry for application in the inlet system for the Pioneer Venus Probe mass spectrometer. Both solenoid type and latching type valves are considered. The study is divided into two principal areas: (1) preparation of a valve specification reflecting the requirements of the inlet system cyclic valves for the Pioneer Venus Probe mass spectrometer and the submittal of this specification to potential valve suppliers for their response and proposal; (2) preparation of a design layout of an optimum cyclic valve meeting all of the valve specification requirements.

Wichmann, H.↗

Longitudinal Solid P Longitudinal Solid Polarized Target for CL get for CLAS12 and Study of Spin AS12 and Study of Spin Structure of Nucleons

A suite of experiments measuring target-spin observables in electron-nucleon scattering (dubbed Run Group C) was conducted at Jefferson Lab's Hall B in Newport News, VA with a new polarized nuclear target known as 'APOLLO' (Ammonia POLarized LOngitudinally). This innovative target is engineered to seamlessly integrate with the advanced 12GeV CEBAF (Continuous Electron Beam Accelerator Facility) accelerator and the Hall B CLAS12 (12 GeV CEBAF Large Acceptance Spectrometer) detector array. The 'APOLLO' target harnesses the power of Dynamic Nuclear Polarization (DNP) to achieve longitudinal polarization of solid ammonia, thereby creating a net polarization in both protons (NH3) and deuterons (ND3). These samples are subjected to a 5 Tesla magnetic field produced by the CLAS12 spectrometer central solenoid, cooled to 1 K using helium evaporation, and subsequently exposed to microwave radiation at a frequency of 140 GHz. This project was made possible through a collaborative partnership between the Jefferson Lab Target Group, Old Dominion University, University of Virginia, Christopher Newport University, and the CLAS Collaboration. Integrating the APOLLO target into CLAS12 presented unique challenges because of its specific spatial and dimensional constraints. This dissertation will highlight the innovative solutions developed to address these challenges, including the creation of a new target material transport system, the incorporation of superconducting magnetic correction coils, and the development of a customized Nuclear Magnetic Resonance (NMR) system. In addition to a detailed description of the development and operation of APOLLO, and an overview of RGC, this document also describes the global data fitting of proton asymmetries in the Deep Inelastic scattering (DIS) and the Resonance regions, and it offers insights into the comprehensive analysis of target polarization data.

Pandey, Pushpa↗

Oak Ridge National Laboratory Neutron Spin Echo Beamline on NB-2

Neutron Spin Echo (NSE) spectroscopy uniquely measures the Q-dependence of slow relaxation dynamics, and having such a machine at HFIR will advance polarized neutron spectroscopy and promote the study of biophysical and energy materials using neutrons. The 2018 Instrument Advisory Board (IAB) advises Neutron Sciences Directorate, ORNL to upgrade the cold neutron delivery system at HFIR, addressing geometrical challenges in neutron transfer from the bright cold source. This is being optimized now: the entrance to the guide system is moving closer to the source, and more guides are being added. However, there are still significant challenges to making the cold flux at the sample world-class. With the proposed guide system, NB-2 can deliver more than 10 6 polarized neutrons per cm 2 /sec below 8Å, and probably 10Å with further optimization. With no potential for running user experiments with neutrons longer than 15Å, the utility of such a machine for biological studies is limited. However, there is a large demand for this class of spectrometer in materials science, chemical engineering, and nanotechnology. Workshops held over the past decade and the three-source vision have highlighted the community's need for a low-angle, high-energy resolution spectrometer at HFIR. A detailed design study of this spectrometer is needed, focusing on optimizing the neutron delivery system for SANS-type studies. This neutron spectrometer would complement studies already performed on both SNSNSE and BASIS by overlapping and extend the dynamic range accessible, while acknowledging the proposed machine, EXPANSE, at the Second Target Station. Two technologies currently exist for such a spectrometer: traditional DC solenoids like those on BL-15 at SNS and IN15 at the ILL, and RF-flipper-based machines similar to RESEDA at FRMII. Either instrument would satisfy the scientific justification. However, there are strong business and scientific cases to utilize the thermal flux, the resonant expertise developed at ORNL, and the potential to utilize an entangled beam of neutrons to probe quantum matter by adopting the neutron resonant spin-echo configuration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the Jefferson Lab Eta Factory (JEF) experiment

The Jefferson Lab Eta Factory (JEF) experiment is an experiment running in Hall D at Jefferson Lab that focuses on studying the decays of the ¿ meson. These decays provide a rich laboratory for searching for new charge conjugation violating / parity conserving (CVPC) processes, looking for hints of Beyond Standard Model physics, and probing higher order terms in Chiral Perturbation Theory. The flagship channel is the rare decay ¿ ¿ p0¿¿, the measurement of which required an upgrade to the existing equipment in Hall D. The experiment uses the GlueX detector, a fixed-target large acceptance spectrometer based on a solenoid magnet containing drift chambers for tracking charged particles and a lead-scintillator barrel calorimeter in the central region and an array of 4 × 4 × 45 cm3 lead glass blocks in the forward region for detecting neutral particles. During the last two years the inner 80×80 cm2 region of the forward calorimeter has been replaced by an array of 2 × 2 × 20 cm3 lead tungstate crystals, which provide factors of two improvement in energy and position resolution. The first round of data taking with this configuration took place this year. A first look at the data will be presented.

Taylor, Simon [Thomas Jefferson National Accelerat↗

Degradation of REBCO coated conductors due to a combination of epoxy impregnation, thermal cycles, and quench: Characteristics and a method of alleviation

REBa2Cu3Ox (REBCO) coated conductors are an enabling technology for >1 GHz nuclear magnetic resonance spectrometers that need >23.5 T solenoids, compact high-field fusion reactors beyond the International Thermonuclear Experimental Reactor, and 20 T class accelerator magnets. An in-depth understanding of stress and strain management is critically needed for these applications. Here, we report experimental data and an analysis of damages of REBCO-coated conductors in several scenarios relevant for their applications in high-field magnets and unique to their multi-layer thin film structure. The examined scenarios include failure induced by quench, failure induced by epoxy impregnation, and failure induced by a combination of epoxy impregnation and quench. The root cause is film blistering and peeling induced by thermally interfacial stresses characteristic of multilayered heteroepitaxial thin film structures on thick substrates utilized. The quantitative stress analysis is introduced using simple and easy to use formulas and clearly indicates how materials and structural characteristics affect the magnitude and the distribution of stresses and deflections. Finally, a simple method is introduced for removing degradation of REBCO coated conductors due to epoxy impregnation. Our data and analysis help our understanding of the practical limit of REBCO-coated conductors and can be utilized as a guidance for the physical design of REBCO coated conductors and high-current cables assembled from them and for minimizing damages.

Yin, Shijian (ORCID:0000000224312274)↗

Probing charged lepton flavor violation with a positron beam at CEBAF (JLAB)

The addition of a high intensity 11 GeV polarized positron beam at the Continuous Electron Beam Accelerator Facility (CEBAF) at JLAB would allow for a search of Charged Lepton Flavor Violation (CLFV) via the process $e^+N \rightarrow \mu^+ X$. The proposed Solenoidal Large Intensity Detector (SoLID) spectrometer, in the configuration with muon chambers, would be ideal for such CLFV searches. Various new physics scenarios, including the phenomenologically convenient Leptoquark (LQ) framework, predict CLFV rates that are within reach of current or planned experiments. A positron beam with instantaneous luminosity, ${\cal L}\sim 10^{38}$ cm$^{-2}$s$^{-1}$, could improve on existing HERA limits by two or three orders of magnitude. The availability of positron beam polarization would also allow for distentangling CLFV effects mediated by left-handed vs. right-handed LQs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electronics integration for the GE2/1 and ME0 GEM detector systems for the CMS phase-2 muon system upgrade

Abstract The Large Hadron Collider is currently undergoing its High Luminosity upgrade, which is set to increase the instantaneous luminosity by about a factor of five. Consequently, the Compact Muon Solenoid experiment is upgrading its muon spectrometer to cope with the increased muon flux in the forward region. The GE2/1 triple-gas electron multiplier detector, which has recently entered the mass production phase, and the ME0 triple-GEM detector system, which is in the late prototyping phase, are undergoing electronics integration. These proceedings briefly discuss the frontend electronics for the GE2/1 and ME0 detector systems, the electronics integration testing process, and the future plans for the frontend electronics of these two detector systems by the CMS GEM collaboration.

Instruments & Instrumentation↗

The Jefferson Lab Eta Factory (JEF) experiment

The Jefferson Lab Eta Factory (JEF) experiment is an upcoming experiment designed to run in Hall D at Jefferson Lab using an upgraded GlueX spectrometer to study various decays of the ? meson. The GlueX spectrometer consists of a ?2 Tesla solenoid magnet housing a liquid hydrogen target and drift chambers used for tracking charged particles and an array of lead glass blocks (the Forward Calorimeter (FCAL)) downstream of the magnet for detecting neutral particles. The decays of the ? meson can be used to measure the light quark mass ratio via the ???+???0 channel and allow access to higher-order terms in Chiral Perturbation Theory via the ???0?? channel. The decays can also be used to constrain new charge-conjugation violating/parity conserving (CVPC) reactions and to search for signatures of dark matter. In particular, the ???0?? channel can be used to search for lepto-phobic dark vector (B) bosons in the reaction ??B? (B??0?) or dark scalar (S) bosons in the reaction ???0S (S???). Studying the rare radiative decay channel ???0?? requires replacing the 4×4×45 cm3 lead glass blocks in the inner region of the FCAL with 2×2×20 cm3 lead tungstate crystals, which will provide twice better position and energy resolution. This talk will describe the JEF physics program and the upgrade to the FCAL.

Taylor, Simon↗

Time Variations of Cosmic-Ray Helium Isotopes with BESS-Polar I

The Balloon-borne Experiment with a Superconducting Spectrometer (BESS) is configured with a solenoidal superconducting magnet and a suite of precision particle detectors, including time-of-flight hodoscopes based on plastic scintillators, a silica-aerogel Cherenkov detector, and a high resolution tracking system with a central jet-type drift chamber. The charges of incident particles are determined from energy losses in the scintillators. Their magnetic rigidities (momentum/charge) are measured by reconstructing each particle trajectory in the magnetic field, and their velocities are obtained by using the time-of-flight system. Together, these measurements can accurately identify helium isotopes among the incoming cosmic-ray helium nuclei up to energies in the GeV per nucleon region. The BESS-Polar I instrument flew for 8.5 days over Antarctica from December 13th to December 21st, 2004. Its long-duration flight and large geometric acceptance allow the time variations of isotopic fluxes to be studied for the first time. The time variations of helium isotope fluxes are presented here for rigidities from 1.2 to 2.5 GV and results are compared to previously reported proton data and neutron monitor data.

Cosmic-ray flux time variations↗

Direct reactions with the AT-TPC

Direct reactions are crucial tools for accessing properties of the atomic nucleus. Fundamental and exotic phenomena such as collective modes, pairing, weakbinding effects and evolution of single-particles energies can be investigated in peripheral collisions between a heavy nucleus and a light target. The necessity of using inverse kinematics to reveal how these structural properties change with isospin imbalance renders direct reactions a challenging technique when using the missing mass method. In this scenario, Active Target Time Projection Chambers (AT-TPC) have demonstrated an outstanding performance in enabling these types of reactions even under conditions of very low beam intensities. The AT-TPC of the Facility for Rare Isotope Beams (FRIB) is a next generation multipurpose Active Target. When operated inside a solenoidal magnet, direct reactions benefit from the measurement of the magnetic rigidity that enables particle identification and the determination of the excitation energy with high resolution without the need of auxiliary detectors. Additionally, the AT-TPC can be coupled to a magnetic spectrometer improving even further its spectroscopic investigation capability. In this contribution, we discuss inelastic scattering and transfer reaction data obtained via the AT-TPC and compare them to theory. In particular, we present the results for the 14 C(p,p′) and 12 Be (p,d) 11 Be reactions. For 14 C, we compare the experimental excitation energy of the first 1 – excited state with coupled-cluster calculationsbased on nuclear interactions from chiral effective field theory and with available shell-model predictions. For 12 Be, we determine the theoretical spectroscopic factors of the 12 Be (p,d) 11 Be transfer reaction in the shell modeland compare them to the experimental excitation spectrum from a qualitative standpoint.

active target↗

Performance of prototype GE1/1 chambers for the CMS muon spectrometer upgrade

The high-luminosity phase of the Large Hadron Collider (HL-LHC) will result in ten times higher particle background than measured during the first phase of LHC operation. In order to fully exploit the highly-demanding operating conditions during HL-LHC, the Compact Muon Solenoid (CMS) Collaboration will use Gas Electron Multiplier (GEM) detector technology. The technology will be integrated into the innermost region of the forward muon spectrometer of CMS as an additional muon station called GE1/1. The primary purpose of this auxiliary station is to help in muon reconstruction and to control level-1 muon trigger rates in the pseudo-rapidity region 1.6 ≤ |η| ≤ 2.2. The new station will contain trapezoidal-shaped GEM detectors called GE1/1 chambers. The design of these chambers is finalized, and the installation is in progress during the Long Shutdown phase two (LS-2) that started in 2019. Several full-size prototypes were built and operated successfully in various test beams at CERN. Here, we describe performance measurements such as gain, efficiency, and time resolution of these prototype chambers, developed after years of R&D, and summarize their behavior in different gas compositions as a function of the applied voltage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A low-cost molecular-leak value

Solenoid operated modular-leak and shutoff valve has been developed for small portable, automated, mass spectrometer used to measure trace constituents of air or other gases. Valve costs much less to produce than precision needle-in-foil type. Yet its performance closely matches that version.

Judson, C. M.↗

Scintillating crystals for the Neutral Particle Spectrometer in Hall C at JLab

This report discusses the quality and performance of currently available PbWO crystals of relevance to high-resolution electromagnetic calorimetry, e.g. detectors for the Neutral Particle Spectrometer at Jefferson Lab or those planned for the Electron–Ion Collider. Since the construction of the Compact Muon Solenoid (CMS) at the Large Hadron Collider (LHC) and early PANDA (The antiProton ANnihilations at DArmstadt) electromagnetic calorimeter (ECAL) the worldwide availability of high quality PbWO 4 production has changed dramatically. We report on our studies of crystal samples from SICCAS/China and CRYTUR/Czech Republic that were produced between 2014 and 2019.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Cosmic Ray Electron Excess

This slide presentation reviews the possible sources for the apparent excess of Cosmic Ray Electrons. The presentation reviews the Advanced Thin Ionization Calorimeter (ATIC) instrument, the various parts, how cosmic ray electrons are measured, and shows graphs that review the results of the ATIC instrument measurement. A review of Cosmic Ray Electrons models is explored, along with the source candidates. Scenarios for the excess are reviewed: Supernova remnants (SNR) Pulsar Wind nebulae, or Microquasars. Each of these has some problem that mitigates the argument. The last possibility discussed is Dark Matter. The Anti-Matter Exploration and Light-nuclei Astrophysics (PAMELA) mission is to search for evidence of annihilations of dark matter particles, to search for anti-nuclei, to test cosmic-ray propagation models, and to measure electron and positron spectra. There are slides explaining the results of Pamela and how to compare these with those of the ATIC experiment. Dark matter annihilation is then reviewed, which represent two types of dark matter: Neutralinos, and kaluza-Kline (KK) particles, which are next explained. The future astrophysical measurements, those from GLAST LAT, the Alpha Magnetic Spectrometer (AMS), and HEPCAT are reviewed, in light of assisting in finding an explanation for the observed excess. Also the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) could help by revealing if there are extra dimensions.

Chang, J.↗