Search NASA⌕ Search

SEARCH · Search NASA

Results for “solid sorbents”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Solid-Sorbent Air Sampler

Portable unit takes eight 24-hour samples. Volatile organic compounds in air collected for analysis by portable, self-contained sampling apparatus. Sampled air drawn through sorbent material, commercial porous polymer of 2, 3-diphenyl-p-phenylene oxide. High-boiling-point organic compounds adsorbed onto polymer, while low-boiling-point organics pass through and returned to atmosphere. Sampler includes eight sample tubes filled with polymeric sorbent. Organic compounds in atmosphere absorbed when air pumped through sorbent. Designed for checking air in spacecraft, sampler adaptable to other applications as leak detection, gas-mixture analysis, and ambient-air monitoring.

Galen, T. J.↗

Solid sorbent air sampler

A fluid sampler for collecting a plurality of discrete samples over separate time intervals is described. The sampler comprises a sample assembly having an inlet and a plurality of discreet sample tubes each of which has inlet and outlet sides. A multiport dual acting valve is provided in the sampler in order to sequentially pass air from the sample inlet into the selected sample tubes. The sample tubes extend longitudinally of the housing and are located about the outer periphery thereof so that upon removal of an enclosure cover, they are readily accessible for operation of the sampler in an analysis mode.

Galen, T. J.↗

6S Return Samples: Assessment of Air Quality in the International Space Station (ISS) Based on Solid Sorbent Air Sampler (SSAS) and Formaldehyde Monitoring Kit (FMK) Analyses

The toxicological assessments of SSAS and FMK analytical results are reported. Analytical methods have not changed from earlier reports. Surrogate standard recoveries from the SSAS tubes were 66-76% for 13C-acetone, 85-96% for fluorobenzene, and 73-89% for chlorobenzene. Post-flight flows were far below pre-flight flows and an investigation of the problem revealed that the reduced flow was caused by a leak at the interface of the pump inlet tube and the pump head. This resulted in degradation of pump efficiency. Further investigation showed that the problem occurred before the SSAS was operated on orbit and that use of the post-flight flows yielded consistent and useful results. Recoveries from formaldehyde control badges were 86 to 104%. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 and formaldehyde contributions). The T values will not be reported for these data due to the flow anomaly. Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols (including acetone) are also shown for each sample. Octafluoropropane (OFP) is not efficiently trapped by the sorbents used in the SSAS. Because formaldehyde is quantified from sorbent badges, its concentration is also listed separately. These five indices of air quality are summarized.

James, John T.↗

(Preliminary) Effects of Ball Milling Zeolite Powders for Use in Additively Manufactured Solid Sorbents

Zeolite 13X is favorable to be used as an adsorbent in carbon dioxide (CO2) removal from the spacecraft cabin air. Reducing the size of the zeolite particles and particle size distribution is thought to increase the capacity of CO2 adsorption of the zeolite 13X powder, and potentially increase its manufacturability as a paste for additive manufacturing or slip casting. This paper will go into detail on the process of using ball milling in order to reduce particle size and particle size distribution of commercial zeolite 13X powder, as well as to characterize CO2 adsorption and manufacturability of the milled powder. Both dry and wet ball milling was analyzed during the experiment. Studies were also ran on the amount of time the powder was milled, rotational speed of the milling machine, ball to powder ratio, ball to jar ratio, and ethanol to powder ratio. The processed powder was then characterized through laser diffraction, SEM, and surface measurement techniques to show that particle size and particle size distribution could be reduced, and to show the effect of the reduced particle size and particle size distribution on CO2 adsorption and manufacturability.

zeolite↗

CO2 removal by solid amine sorbents. 1: Experimental studies of amine resin IR-45 with regard to spacecraft applications. 2: Computer program for predicting the transient performance of solid amine sorbent systems

The sorbent behavior of solid amine resin IR-45 with regard to potential use in regenerative CO2-removal systems for manned spacecraft is considered. Measurements of equilibrium sorption capacity of IR-45 for water and for CO2 are reported, and the dynamic mass transfer behavior of IR-45 beds is studied under conditions representative of those expected in a manned spacecraft. A digital computer program was written for the transient performance prediction of CO2 removal systems comprised of solid amine beds. Also evaluated are systems employing inorganic molecular-sieve sorbents. Tests show that there is definitely an effect of water loading on the absorption rate.

Wright, R. M.↗

Efficacy of FTIR Analysis in Determining CO2 Loading on Diglycolamine

In support of advanced air revitalization technologies to enable human spaceflight beyond low earth orbit, performance studies have been conducted using a liquid amine, Diglycolamine (DGA) between teams at NASA?s Johnson Spaceflight Center (JSC) and Ames Research Center (ARC). Liquid amines have been used in regenerable earth-based systems to remove CO2 from industrial systems as well as for closed-environment air revitalization because they can be regenerated at lower temperatures than solid sorbent systems. As an additional advantage to solid sorbent based systems, liquid sorbents can be cycled between an adsorbing contactor and degassing chamber, thereby reducing system complexity by operation in a continuous loop. In an effort to inform a regeneration system design for micro-gravity applications, ARC has performed a number of tests to characterize the degas mechanics of DGA. In order to accurately measure the amount of CO2 captured or released by the amine, methods such as gravimetric weighing and chemical decomposition are reasonable, however the initial design for a scaled down degas system required analysis on small sample sizes. In order to accomplish CO2 loading measurements with a sample size of approximately 500µL, Fourier-transform infrared spectroscopy (FTIR) was used. Calibration against acid decomposition showed relatively good correlation and test data showed reasonable adherence to expected trends, however more extensive testing should be conducted to fully validate the usage of FTIR to determine CO2 loading on DGA.

Diglycolamine↗

Novel Liquid Sorbent C02 Removal System for Microgravity Applications

Removing Carbon Dioxide (CO2) from a spacecraft environment for deep space exploration requires a robust system that is low in weight, power, and volume. Current state-of-the-art microgravity compatible CO2 removal systems, such as the carbon dioxide removal assembly (CDRA), utilize solid sorbents that demand high power usage due to high desorption temperatures and a large volume to accommodate for their comparatively low capacity for CO2. Additionally, solid sorbent systems contain several mechanical components that significantly reduce reliability and contribute to a large overall mass. A liquid sorbent based system has been evaluated as an alternative is proposed to consume 65% less power, weight, and volume than solid based CO2 scrubbers. This paper presents the design of a liquid sorbent CO2 removal system for microgravity applications.

Rogers, Tanya↗

NASA Exploration Systems & Habitation (X-Hab)Academic Innovation Challenge 2020: Microgravity Gas/Liquid Separator for the CO2 Revitalization System Final Report

This report outlines the efforts of UNT X-Hab Team on a project titled, Microgravity Gas/Liquid Separator for the CO2 Revitalization System. The project is executed as a senior design project during academic year 2019-2020. The X-Hab 2020 Academic Innovation Challenge has selected eleven senior design teams from colleges across the US to demonstrate working prototypes for exploration systems and habitation. UNT has been tasked with the creation of a gas-liquid separator for an air revitalization system. Air revitalization technology has been used to support spaceflight by removing CO2 from enclosed systems in order to maintain breathable air. Solid sorbents such as zeolites or lithium hydroxide have been used in the past for these systems but are difficult to handle in microgravity environments and require a large amount of energy. This challenge aims to demonstrate vortex phase separator (VPS) technology for removing H2O from a CO2 stream. However, VPS technology also has the capability of using liquid sorbents for removing CO2 from an air stream. Further research could be done on liquid sorbents, such as liquid amine, in use with VPS systems. This would potentially be an alternative technology in replacing use of solid sorbents in CO2 removal systems. In 2019, NASA proposed a design that uses a gas/liquid contactor to allow for efficient contact between the two fluid phase. This was integrated into an overall CO2 removal system. The subsystems for gas-liquid separation and storage in NASA’s previous models for CO2 removal system could be replaced with a VPS. Innovative vortex separator technology is expected to allow for high throughput flow and highly efficient CO2 removal compared to other gas-liquid separation technologies. VPS relies on centripetal driven buoyancy forces to form a gas-liquid vortex within a fixed, right circular cylinder. The gas stream enters the separator through a tangential nozzle and breaks into very small bubbles (<<1 mm) resulting in a very large contact surface area for interaction with the liquid stream via energy and mass exchange. VPS technology can handle mismatches in inlet and outlet flow rates and system volume changes through the range of liquid thickness held in the separator (i.e., buffering and accumulating capability), and requires low pressure differences (<5-10 in H2O in most cases) for operation. The X-Hab 2020 team leverages these characteristics to investigate VPS technology as an alternative CO2 removal technology.

Alyssa Sarvadi↗

Efficacy of FTIR Analysis in Determining CO2 Loading on Diglycolamine

In support of advanced air revitalization technologies to enable human spaceflight beyond low earth orbit, performance studies have been conducted using a liquid amine, Diglycolamine (DGA) between teams at NASA's Johnson Spaceflight Center (JSC) and Ames Research Center (ARC). Liquid amines have been used in regenerable earth-based systems to remove CO2 from industrial systems as well as for closed-environment air revitalization because they can be regenerated at lower temperatures than solid sorbent systems. As an additional advantage to solid sorbent-based systems, liquid sorbents can be cycled between an adsorbing contactor and degassing chamber, thereby reducing system complexity by operation in a continuous loop. In an effort to inform a regeneration system design for micro-gravity applications, ARC has performed a number of tests to characterize the degas mechanics of DGA. In order to accurately measure the amount of CO2 captured or released by the amine, methods such as gravimetric weighing and chemical desorption are reasonable, however the first iteration test setup for a scaled down degas system required analysis on small sample sizes. Fourier-transform infrared spectroscopy (FTIR) analysis was experimentally evaluated to analyze CO2 concentration because it can produce measurements with sample sizes on the order of 100's of μL. Calibration against chemical desorption showed relatively good correlation and test data showed reasonable adherence to expected trends, however more extensive testing should be conducted to fully validate the usage of FTIR to determine CO2 loading on DGA.

Diglycolamine↗

Absorption of carbon dioxide by solid hydroxide sorbent beds in closed-loop atmospheric revitalization system

The reactions of carbon dioxide with various metals are discussed. The equations which govern the rates of CO2 removal from the atmosphere in spacecraft environmental control systems are discussed. Results from performance testing of various Space Shuttle environmental control systems are presented with the correlation of the equations to the performance given.

Davis, S. H., Jr.↗

Improvements in Ionic Liquid Technology for Carbon Dioxide Removal Applications

Carbon dioxide removal from cabin air continues to be of vital importance for future space missions. Current and proposed approaches have employed solid sorbents, hollow fiber membrane separators, and direct liquid sorbent contactors. Recent developments in ionic liquids have potential to improve performance in all three of these technologies. Efficient encapsulation of ionic liquids by polymeric shell can enable their use in a solid sorbent-like configuration without significant integration intervention to the current space technology. Poly(ionic liquid)-ionic liquid membranes have the potential to cross over the Robeson selectivity-permeability upper bound, and thereby outperform traditional membranes used in hollow fibers. Advances in ionic liquid chemistry enables performance improvements in liquid sorbent contactors owing to the tunable gravimetric CO2 capacity, reaction enthalpy and liquid viscosity. This paper will describe recent work in each of these areas.

Ionic Liquid,Carbon Dioxide,Air Revitalization↗

CO2 Capacity Sorbent Analysis Using Volumetric Measurement Approach

In support of air revitalization system sorbent selection for future space missions, Ames Research Center (ARC) has performed CO2 capacity tests on various solid sorbents to complement structural strength tests conducted at Marshall Space Flight Center (MSFC). The materials of interest are: Grace Davison Grade 544 13X, Honeywell UOP APG III, LiLSX VSA-10, BASF 13X, and Grace Davison Grade 522 5A. CO2 capacity was for all sorbent materials using a Micromeritics ASAP 2020 Physisorption Volumetric Analysis machine to produce 0 C, 10 C, 25 C, 50 C, and 75 C isotherms. These data are to be used for modeling data and to provide a basis for continued sorbent research. The volumetric analysis method proved to be effective in generating consistent and repeatable data for the 13X sorbents, but the method needs to be refined to tailor to different sorbents.

Huang, Roger↗

CO2 Capacity Sorbent Analysis Using Volumetric Measurement Approach

In support of air revitalization system sorbent selection for future space missions, Ames Research Center (ARC) has performed CO2 capacity tests on various solid sorbents to complement structural strength tests conducted at Marshall Space Flight Center (MSFC). The materials of interest are: Grace Davison Grade 544 13X, Honeywell UOP APG III, LiLSX VSA-10, BASF 13X, and Grace Davison Grade 522 5A. CO2 capacity was for all sorbent materials using a Micromeritics ASAP 2020 Physisorption Volumetric Analysis machine to produce 0C, 10C, 25C, 50C, and 75C isotherms. These data are to be used for modeling data and to provide a basis for continued sorbent research. The volumetric analysis method proved to be effective in generating consistent and repeatable data for the 13X sorbents, but the method needs to be refined to tailor to different sorbents.

Air Revitalization↗

The development and testing of a volatile organics concentrator for use in monitoring Space Station water quality

The Volatile Organics Concentrator (VOC) system, designed to attach to a gas chromatograph/mass spectrometer (GC/MS) for the analyses of volatile organic compounds in water on Space Station Freedom, is described. Organic volatiles are collected and concentrated in the VOC by means of two primary solid sorbent tubes and desorbed into the GC/MS system. The paper describes the results of testing the VOC breadboard using a GC/MS system. Evaluations performed on 39 organic compounds recovered from water samples were compared with data for these compounds using direct injection/GC/MS and purge and trap/GC/MS procedures. The results demonstrate that the VOC/GC/MS system's detection limits for the 39 compounds analyzed are comparable to those of the EPA Method 524.2, and for many compounds reaching a factor of 5 lower.

Bodek, Itamar↗

Membrane Separation Processes at Low Temperatures

The primary focus of Kennedy Space Center's gas separation activities has been for carbon dioxide, nitrogen, and argon used in oxygen production technologies for Martian in-situ resource utilization (ISRU) projects. Recently, these studies were expanded to include oxygen for regenerative life support systems. Since commercial membrane systems have been developed for separation of carbon dioxide, nitrogen, and oxygen, initially the studies focused on these membrane systems, but at lower operating temperatures and pressures. Current investigations art examining immobilized liquids and solid sorbents that have the potential for higher selectivity and lower operating temperatures. The gas separation studies reported here use hollow fiber membranes to separate carbon dioxide, nitrogen, and argon in the temperature range from 230 to 300 K. Four commercial membrane materials were used to obtain data at low feed and permeate pressures. These data were used with a commercial solution-diffusion modeling tool to design a system to prepare a buffer gas from the byproduct of a process to capture Martian carbon dioxide. The system was designed to operate, at 230 K with a production rate 0.1 sLpm; Feed composition 30% CO2, 44% N2, and 26% Ar; Feed pressure 104 kPa (780); and Permeate pressure 1 kPa (6 torr); Product concentration 600 ppm CO2. This new system was compared with a similar system designed to operate at ambient temperatures (298 K). The systems described above, along with data, test apparatus, and models are presented.

Parrish, Clyde↗

Multisorbent tubes for collecting volatile organic compounds in spacecraft air

The sampling capability of Tenax-TA tubes, used in the National Aeronautics and Space Administration's solid sorbent air sampler to trap and concentrate contaminants from air aboard spacecraft, was improved by incorporating two sorbents within the tubes. Existing tubes containing only Tenax-TA allowed highly volatile compounds to "break through" during collection of a 1.5 L air sample. First the carbon molecular sieve-type sorbents Carboxen 569 and Carbosieve S-III were tested for their ability to quantitatively trap the highly volatile compounds. Breakthrough volumes were determined with the direct method, whereby low ppm levels of methanol or Freon 12 in nitrogen were flowed through the sorbent tubes at 30 mL/min, and breakthrough was detected by gas chromatography. Breakthrough volumes for methanol were about 9 L/g on Carboxen 569 and 11 L/g on Carbosieve S-III; breakthrough volumes for Freon 12 were about 7 L/g on Carboxen 569 and > 26 L/g on Carbosieve S-III. Next, dual-bed tubes containing either Tenax-TA/Carbosieve S-III, Tenax-TA/Carboxen 569, or Carbotrap/Carboxen 569 to a 10-component gas mixture were exposed, in dry and in humidified air (50% relative humidity), and percentage recoveries of each compound were determined. The Tenax-TA/Carboxen 569 combination gave the best overall recoveries (75-114% for the 10 compounds). Acetaldehyde had the lowest recovery (75%) of the 10 compounds, but this value was still an improvement over either the other two sorbent combinations or the original single-sorbent tubes.

NASA Center JSC↗

Assessment of Air Quality in the International Space Station (ISS) and Space Shuttle Based on Samples Returned Aboard STS-ll1 (UF2) in June 2002

The toxicological assessments of grab sample canisters (GSCs) and 2 solid sorbent air samplers (SSASs) returned aboard STS-111 are reported. Analytical methods have not changed from earlier reports. Surrogate standard recoveries from the GSCs were 86-106% and 62% to 136 % from the SSASs; 2 tubes with low surrogate recoveries were not reported. Pressure tracking indicated no leaks in the canisters during analysis. Recoveries from lab and trip controls for formaldehyde analyses ranged from 87 to 96%. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 and formaldehyde contributions). Because of the inertness of Freon 218 (octafluoropropane, OFP), Its contribution to the NMVOC is subtracted and tabulated separately. Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols (including acetone) are also shown for each sample. Because formaldehyde is quantified from sorbent badges, its concentration is listed separately. The table shows that the air quality in general was acceptable for crew respiration; however, certain values shown in bold require further explanation. The 1.05 T value on 2/28/02 was caused by an unusually high measurement ofhexamethylcyc1otrisiloxane (T value = 0.50), which is not a concern. The MPLM T value of 1.42 and the alcohol level of 7.5 mg/cu m were due to an overall polluted atmosphere, which was expected at first entry. The major T-value component was carbon monoxide at a contribution of 0.44 units. Since the crew was only exposed momentarily to the polluted atmosphere, no health effects are expected. The formaldehyde value of 0.060 mg/cu m found in the Lab sample from 3/27/02 is cause for concern because the Lab consistently shows higher concentrations of formaldehyde than the SM and occasionally the concentrations are above the acceptable guideline. Levels of OFP have remained low, suggesting that no further leaks of the SM air conditioner have occurred.

James, John T.↗

Assessment of Air Quality in the Shuttle and International Space Station (ISS) Based on Samples Returned by STS-104 at the Conclusion of 7A

The toxicological assessment of air samples returned at the end of the STS-l04 (7 A) flight to the ISS is reported. ISS air samples were taken in June and July 2001 from the Service Module, FGB, and U.S. Laboratory using grab sample canisters (GSCs) and/or formaldehyde badges. Preflight and end-of-mission samples were obtained from Atlantis using GSCs. Solid sorbent air sampler (SSAS) samples were obtained from the ISS in April, June, and July. Analytical methods have not changed from earlier reports, and all quality control measures were met.

James, John T.↗