Search NASA⌕ Search

SEARCH · Search NASA

Results for “solid state streak camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Solid state streak camera prototype performance testing and future upgrades

Streak Cameras are an essential diagnostic tool used in shock physics and high energy density physics experiments. Such experiments require well calibrated temporally resolving diagnostics for studying events that occur on the nanosecond to microsecond time scales. The Nevada National Security Site (NNSS) and Sandia National Laboratories (SNL) have built a 42-channel solid state streak camera (SSSC) prototype as a proof of concept for use as a streak camera replacement. This work is part of an ongoing project to develop the technology to a level competitive with analog streak cameras. This manuscript discusses the device concept, results from electronic and laser testing, and recent improvements to increase the device’s dynamic range.

Plasma diagnostics - interferometry, spectroscopy ↗

Solid State Streak Camera Prototype Electronic Performance Testing and Characterization

Streak Cameras are an essential diagnostic tool used in shock physics and high energy density physics experiments. Such experiments require well calibrated temporally resolved diagnostics for studying events that occur in the nanosecond to microsecond time scales. Although streak cameras are among the most common detectors used within the high energy density physics community, they require frequent calibration and typically lack reproducibility in the fine detail. A solid state device with similar temporal performance characteristics could provide several advantages to current streak camera systems by utilizing discrete spatial resolution set by the sensor diodes. National Security Technologies (NSTec) has built a multi-channel solid state streak camera (SSSC) prototype, in collaboration with Sandia National Laboratories, as part of an ongoing project to develop the technology to a level competitive with analog streak cameras. The device concept and results from electronic testing of our first prototypes will be discussed in this manuscript. These measurements will be used as a base for future SSSC development projects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The ultrafast pixel array camera system and its applications in high energy density physics

Diagnostics in high energy density physics, shock physics, and related fields are primarily driven by a need to record rapidly time-evolving signals in single-shot events. These measurements are often limited by channel count and signal degradation issues on cable links between the detector and digitizer. Here we present the Ultrafast Pixel Array Camera (UPAC), a compact and flexible detector readout system with 32 waveform-recording channels at up to 10 Gsample/s and 1.8 GHz analog bandwidth. The compact footprint allows the UPAC to be directly embedded in the detector environment. A key enabling technology is the PSEC4A chip, an eight-channel switch-capacitor array sampling device with up to 1056 samples/channel. The UPAC system includes a high-density input connector that can plug directly into an application-specific detector board, programmable control, and serial readout, with less than 5 W of power consumption in full operation. We present the UPAC design and characterization, including a measured timing resolution of ~20 ps or better on acquisitions of sub-nanosecond pulses with minimal system calibrations. Example applications of the UPAC are also shown to demonstrate operation of a solid-state streak camera, an ultrafast imaging array, and a neutron time-of-flight spectrometer.

47 OTHER INSTRUMENTATION↗

Impact of laser phase and amplitude noises on streak camera temporal resolution

Streak cameras are now reaching sub-picosecond temporal resolution. In cumulative acquisition mode, this resolution does not entirely rely on the electronic or the vacuum tube performances but also on the light source characteristics. The light source, usually an actively mode-locked laser, is affected by phase and amplitude noises. In this paper, the theoretical effects of such noises on the synchronization of the streak system are studied in synchroscan and triggered modes. More precisely, the contribution of band-pass filters, delays, and time walk is ascertained. Methods to compute the resulting synchronization jitter are depicted. The results are verified by measurement with a streak camera combined with a Ti:Al{sub 2}O{sub 3} solid state laser oscillator and also a fiber oscillator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Self‐Trapped and Free Exciton Dynamics in Vacuum‐Deposited Cesium Copper Iodide Thin Films

Abstract Highly photoluminescent, lead‐free perovskites are of interest for displays and solid‐state light‐emitting devices. In this report, streak camera‐based time‐resolved emission and transient absorption spanning visible to deep‐ultraviolet (UV) wavelengths are utilized to study self‐trapped and free exciton dynamics in vacuum‐deposited cesium copper halide thin films of CsCu 2 I 3 and Cs 3 Cu 2 I 5 . Self‐trapped exciton emission of CsCu 2 I 3 exhibits more noticeable changes with time in the peak position and width than Cs 3 Cu 2 I 5 . UV‐to‐blue emission is detectable for both compositions, where free exciton emission is distinct for CsCu 2 I 3 . Transient absorption shows loss of ground‐state bleach signals at early time delays for both, and the bleach signal shifts toward higher energy as time delay increases, likely due to strains induced by the newly created self‐trapped excitons. Global analysis performed on the transient absorption results yields time constants in these materials that build an overall dynamic scheme. This work aids in building a complete picture regarding light emission in these promising materials.

36 MATERIALS SCIENCE↗

An optically passive method that rate doubles 2-GHz timing fiducials

Solid-state optical comb-pulse generators provide a convenient and accurate method to include timing fiducials in a streak camera image for time base correction. Commercially available vertical-cavity surface-emitting lasers (VCSEL’s) emitting in the visible currently in use can be modulated up to 2 GHz. An optically passive method is presented to interleave a time-delayed path of the 2-GHz comb with itself, producing a 4-GHz comb. This technique can be applied to VCSEL’s with higher modulation rates. A fiber-delivered, randomly polarized 2 GHz VCSEL comb is polarization split into s polarization and p polarization paths. One path is time delayed relative to the other by twice the 2-GHz rate with 1-ps accuracy; the two paths then recombine at the fiber-coupled output. High throughput (≥90%) is achieved by carefully using polarization beam-splitting cubes, a total internal reflection beam-path–steering prism, and antireflection coatings. The glass path-length delay block and turning prism are optically contacted together. The beam polarizer cubes that split and recombine the paths are precision aligned and permanently cemented into place. We expect the palm-sized, inline fiber-coupled, comb-rate–doubling device to maintain its internal alignment indefinitely.

optical comb-pulse generators, timing fiducials, s↗

A rate-doubled 10-GHz fiducial comb generator for precision optical timing calibration

Solid-state optical fiducial timing pulse generators provide a convenient and accurate method to include timing fiducials in a streak-camera image for time-base correction. Current commercially available vertical-cavity surface-emitting lasers (VCSEL’s) emitting in the visible range can be amplitude modulated up to 5 GHz. An optically passive method is utilized to interleave a time-delayed path of the 5-GHz pulsed light with itself, producing a 10-GHz pulsed fiducial, or comb. Comb pulse rates at 0.5, 1.0 and 2.5 GHz can also be selected. The instrument presented is a self-contained and portable generator with primary use for streak-camera temporal calibration. Applications can also be extended to many other optical timing needs. The VCSEL output is fiber optic coupled at a wavelength of 680 nm (visible red) with a nearly Gaussian pulse shape. The peak power of each ~50-ps FWHM comb pulse at 5-GHz operation, or picket, is approximately 5 mW. The low phase noise of the internal microwave modulation drive source provides low pulse to pulse jitter. An external reference frequency standard can be utilized to synchronize the output to external timing equipment. A selectable internal reference frequency crystal oscillator is incorporated for stand-alone operation.

42 ENGINEERING↗

Visualization of expanding warm dense gold and diamond heated rapidly by laser-generated ion beams

With the development of several novel heating sources, scientists can now heat a small sample isochorically above 10,000 K. Although matter at such an extreme state, known as warm dense matter, is commonly found in astrophysics (e.g., in planetary cores) as well as in high energy density physics experiments, its properties are not well understood and are difficult to predict theoretically. This is because the approximations made to describe condensed matter or high-temperature plasmas are invalid in this intermediate regime. A sufficiently large warm dense matter sample that is uniformly heated would be ideal for these studies, but has been unavailable to date. We have used a beam of quasi-monoenergetic aluminum ions to heat gold and diamond foils uniformly and isochorically. For the first time, we visualized directly the expanding warm dense gold and diamond with an optical streak camera. Furthermore, we present a new technique to determine the initial temperature of these heated samples from the measured expansion speeds of gold and diamond into vacuum. We anticipate the uniformly heated solid density target will allow for direct quantitative measurements of equation-of-state, conductivity, opacity, and stopping power of warm dense matter, benefiting plasma physics, astrophysics, and nuclear physics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Absolute Hugoniot measurements from a spherically convergent shock using x-ray radiography

Here, the canonical high pressure equation of state measurement is to induce a shock wave in the sample material and measure two mechanical properties of the shocked material or shock wave. For accurate measurements, the experiment is normally designed to generate a planar shock which is as steady as possible in space and time, and a single state is measured. A converging shock strengthens as it propagates, so a range of shock pressures is induced in a single experiment. However, equation of state measurements must then account for spatial and temporal gradients. We have used x-ray radiography of spherically converging shocks to determine states along the shock Hugoniot. The radius-time history of the shock, and thus its speed, was measured by radiographing the position of the shock front as a function of time using an x-ray streak camera. The density profile of the shock was then inferred from the x-ray transmission at each instant of time. Simultaneous measurement of the density at the shock front and the shock speed determines an absolute mechanical Hugoniot state. The density profile was reconstructed using the known, unshocked density which strongly constrains the density jump at the shock front. The radiographic configuration and streak camera behavior were treated in detail to reduce systematic errors. Measurements were performed on the Omega and National Ignition Facility lasers, using a hohlraum to induce a spatially uniform drive over the outside of a solid, spherical sample and a laser-heated thermal plasma as an x-ray source for radiography. Absolute shock Hugoniot measurements were demonstrated for carbon-containing samples of different composition and initial density, up to temperatures at which K-shell ionization reduced the opacity behind the shock. Here we present the experimental method using measurements of polystyrene as an example.

47 OTHER INSTRUMENTATION↗

Pulsed power driven cylindrical wire array explosions in different media

Cylindrical copper wire array explosions were carried out in de-ionized water, sodium polytungstate solution, nitromethane, and polyester in order to obtain high energy density conditions in the vicinity of implosion using the generated converging shock waves. The utilization of different materials in which the array is immersed can contribute to this goal with higher density resulting in higher shock velocities and possible combustion. The generated shock waves were captured by a framing and a streak camera and shock velocities were calculated and compared. Pressure behind the shock front was calculated using known hydrodynamic relations (for water, polytungstate, and polyester) and compared to two-dimensional hydrodynamic simulations coupled with equations of state (for water and polyester). It was demonstrated that despite lower shock wave velocity in polytungstate solution than water, the pressures generated are similar in both materials. In polyester, both shock velocities and generated pressures are 2-4 times higher than in water. Furthermore, it was shown that it is possible to carry out these explosions in a solid which has several advantages compared to liquids, such as not relying on waterproof systems and easier transportation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High Energy Density Physics Experiments with Intense Heavy Ion Beams

The US heavy ion fusion science program has developed techniques for heating ion-beam-driven warm dense matter (WDM) targets. The WDM conditions are to be achieved by combined longitudinal and transverse space-charge neutralized drift compression of the ion beam to provide a hot spot on the target with a beam spot size of about 1 mm, and pulse length about 1-2 ns. As a technique for heating volumetric samples of matter to high energy density, intense beams of heavy ions are capable of delivering precise and uniform beam energy deposition dE/dx, in a relatively large sample size, and the ability to heat any solid-phase target material. Initial experiments use a 0.3 MeV K+ beam (below the Bragg peak) from the NDCX-I accelerator. Future plans include target experiments using the NDCX-II accelerator, which is designed to heat targets at the Bragg peak using a 3-6 MeV lithium ion beam. The range of the beams in solid matter targets is about 1 micron, which can be lengthened by using porous targets at reduced density. We have completed the fabrication of a new experimental target chamber facility for WDM experiments, and implemented initial target diagnostics to be used for the first target experiments in NDCX-1. The target chamber has been installed on the NDCX-I beamline. The target diagnostics include a fast multi-channel optical pyrometer, optical streak camera, VISAR, and high-speed gated cameras. Initial WDM experiments will heat targets by compressed NDCX-I beams and will explore measurement of temperature and other target parameters. Experiments are planned in areas such as dense electronegative targets, porous target homogenization and two-phase equation of state.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗