Search NASA⌕ Search

SEARCH · Search NASA

Results for “solutions center”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Clean Energy Solutions Center Services

The Clean Energy Solutions Center is a web-based resource that helps governments design and adopt policies and programs that support the deployment of clean energy technologies. The Solutions Center's three main offerings are Ask an Expert policy assistance, training and peer-to- peer learning forums and a rich library of technical tools and publications. These services are provided at no cost to users.

ask an expert↗

Development of new techniques for the characterization of crystals and their growth solutions: Center director's discretionary fund

The solubility measurement system and the laser scattering microscope system were designed, built, and utilized for the study of crystal growth solutions and crystal characterization measurements. Solubility measurements and crystal defect maps were made with this equipment for a number of new materials. In some cases, where there have been published solubility data (i.e., TGS), more accurate measurements were made and discrepancies in the published data were resolved. The design of these instruments is presented along with a description of their use and some typical data generated using them.

Kroes, Roger L.↗

Advancing Energy Efficiency Through Workforce Training

This Final Technical Report summarizes the work done on to develop and implement the Energy Basics Training Tool with industry partners and the Pacific Northwest National Laboratory. This project leveraged existing infrastructure and content developed by DOE in the Building America Solution Center (BASC) and Building Science Education Solution Center (BSESC) to design model content sets for use in entry-level construction programs at the high school certificate, boot camp, and other entry level training programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scaling a Smart Sub-metered Electrical Data Solution for the Center

Currently, there is no single Center-level point solution that enables facility systems data to be collected and stored from buildings on-site, on-demand, and through a faceted search capability that would enable the cultivation of deeper insights into incipient facility-related issues that would otherwise be overlooked. Such insights would represent a powerful and very valuable tool to aid in data-driven decision making and informing actionable steps for remediation and resolution of these problems. Access to electrically sub-metered data via hardware upgrades is in the process of being restored for Building N232, Sustainability Base, but this is only the first step. The native software capabilities that were originally part of a proposed Agencywide Smart Center initiative project can unlock the ability to access actionable insights. This work would also nicely complement many initiatives that are actively being pursued, under consideration, or pending submission to this same call at the Center. This project is poised to support an NRSAA with Verdigris Technologies, as well as in support of an Agencywide Smart Center initiative. Monitoring electrical consumption usage at the most granular level in Bldg. N232 will be instrumental in accurately quantifying potential utility costs and investments, and monitoring usage trends, as it is being converted into hoteling spaces, to help. This will also help with determining how the capability can scale more broadly across the Center and Agency at large.

Rodney Alexander Martin↗

Scaling a Smart Sub-metered Electrical Data Solution for the Center

Currently, there is no single Center-level point solution that enables facility systems data to be collected and stored from buildings on-site, on-demand, and through a faceted search capability that would enable the cultivation of deeper insights into incipient facility-related issues that would otherwise be overlooked. Such insights would represent a powerful and very valuable tool to aid in data-driven decision making and informing actionable steps for remediation and resolution of these problems. Access to electrically sub-metered data via hardware upgrades is in the process of being restored for Building N232, Sustainability Base, but this is only the first step. The native software capabilities that were originally part of a proposed Agencywide Smart Center initiative project can unlock the ability to access actionable insights. This work would also nicely complement many initiatives that are actively being pursued, under consideration, or pending submission to this same call at the Center. This project is poised to support an NRSAA with Verdigris Technologies, as well as in support of an Agencywide Smart Center initiative. Monitoring electrical consumption usage at the most granular level in Bldg. N232 will be instrumental in accurately quantifying potential utility costs and investments, and monitoring usage trends, as it is being converted into hoteling spaces, to help. This will also help with determining how the capability can scale more broadly across the Center and Agency at large.

Rodney Alexander Martin↗

CAD-based Energy & Cost Models Prove Affordable Net Zero Energy Performance for WonderWindows + 24" On-center Framing

Windows are thermally the “weakest link” in the building envelope. Increasing the thermal resistance of windows can make buildings more energy efficient and reduce the cost of electricity needed for conditioning the building. The proper design and placement of framing can also help to reduce the thermal bridging that occurs near the window frame area. This study investigates the energy performance of multi-pane acrylic windows fitting 24" on-center framing. Initial parametric analysis is done for a single zone accessory dwelling unit (ADU). Then, an energy model was developed for three types of wood-framed buildings: townhomes, stacked flats and hotels. A whole building energy simulation is performed for each of these building types in hot-humid Houston, mixed-humid New York, and cold-humid Minneapolis climates. The results show up to a 39% reduction in heating, ventilation, and air-conditioning (HVAC) related electricity consumption for the cold climate compared to the Base case which has window and wall properties based on ASHRAE standard 90.1 2019. In the hot climate, a modest increase in electricity consumption was seen due to an increase in cooling electricity demand. The ADU achieved Net Zero Energy performance in all 3 Climate Zones despite having the highest exterior surface area-to-floor area ratio: the ADU also had the highest PV kW to floor area ratio compared to the other multi-story building types. The townhomes, hotel and stacked flats respectively met 73, 52 and 57 % of electrical use in Houston, 71, 48 and 56 % in New York, and 63, 40 and 53 % in Minneapolis from energy produced by rooftop solar. If 400 W solar panels are used instead of 320 W panel used for energy simulation, it is estimated that in the townhomes, hotel and stacked flats rooftop solar can meet 91, 65 and 71 % of electrical use in Houston; 89, 60 and 70% in New York, and 79, 50 and 66 % in Minneapolis. A preliminary evaluation of cost shows that such superior performance can potentially be achieved at less first cost with this 24"on-center solution than conventional construction. All the building types at the three locations used for simulation had net energy use intensity under 20 kBtu/sf/year with 320 W solar panel and under 17 kBtu/sf/year with 400 W solar panel. Further tailoring of building envelope R-values and window solar heat gain to particular Climate Zone locations for each building type shows promise in reducing the HVAC electricity use that comprises almost half of building energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Root genetics in the field to understand drought adaptation and carbon sequestration (Final Scientific/Technical Report)

For all crop plants, roots play a critical role in growth. Roots anchor the plants, and are the primary site of nutrient and water uptake. Roots are also the main source of C to soil in the form of root tissues and exudates, and thus greatly influence SOM stocks. To perform these functions, primary roots extend into soil, producing a network of branching roots of characteristic form, known as its root system architecture (RSA). RSA varies among species, and among varieties within a species that are adapted to different environments. Root traits are major targets for the second green revolution because of their potential to improve crop productivity, increase drought tolerance and nutrient acquisition, and increase C capture of soil. Improving the quality of roots in maize will be particularly valuable, since this crop is planted on over 92 million acres annually in the US. The future sustainability of agricultural systems relies on their ability to enhance soil organic matter (SOM) storage and reduce GHG emissions, while maintaining or enhancing productivity. This program had two components, Sensors and Models. For the first component, we designed and built a high-throughput phenotyping platform for root pulling of maize plants. This eliminated the physical labor of manually pulling up plants and reduced the number of personnel required down to one. The standardized pulling mechanism allowed recording force curves during the pulling process, providing additional information. We validated that the maximum force for pulling the root system was well-correlated with the root system mass and provided root crowns for further RSA analysis. These root crowns identified significant correlations with 2D root area and root depth, along with 3D root volume, total root length and number of root tips. We then used this system for field-based studies in maize on the genetics of root system architecture and its relation to nitrogen-use efficiency (NUE), including using lines relevant to the Corteva breeding program. Varieties were also evaluated at Corteva sites in the cornbelt and Danforth farm in Missouri, to establish responses across sites. From these studies we have identified genetic loci associated with root traits and created mutant lines for these loci and correlations of root traits with NUE. For the Models component, we worked to incorporate root and soil characteristics into the MEMS 2.0 soil and ecosystem biogeochemical model. Existing soil C models, such as Century, are unable to represent specific root trait interactions with the soil environment and therefore to accurately forecast the potential C sequestration benefits of root breeding under different climatic and soil type conditions. We have developed the MEMS 2.0 ecosystem biogeochemical model to improve quantification of farm-scale soil carbon and greenhouse gas emissions. The new knowledge and large datasets produced by this project will be used to develop and drive an innovative model capable of forecasting the impacts on soil C stocks and nutrient dynamics. An innovation was to use the empirical data from the field studies (in 1, above) to model genetic variation in nitrogen use efficiencies and soil C input. Our work demonstrated that maize root-derived C rapidly replaces existing soil C and after 3 years of continuous maize, up to 20% of soil organic C in the topsoil (0-15cm) and 3% in the subsoil (15-30cm) was contributed by maize. However, this contribution did not entirely represent a net increase. Root C contribution to soil was affected by maize genetics. We have analyzed soils derived from the CSU field trials for C and N stocks, in the different soil physical fractions represented by the MEMS model, using both physical fractionation with elemental analyses, and Fourier transformed infrared spectroscopy. Data will be used to link crop nitrogen use efficiencies with soil C sequestration and provide data to bridge the field trials with the model development, for verification of model predictions. The project had a number of successful outcomes: we have used the new phenotyping platform to identify new genetic loci that can enhance root phenotypes; we have partnered with multiple maize seed companies phenotype varieties in their breeding programs; we have developed the MEMS model that can help inform industry on the potential for carbon sequestration in the agricultural sector, and which is now available at the CSU Soil Carbon Solutions Center for use.

59 BASIC BIOLOGICAL SCIENCES↗

Diurnal CO variations in the Venus mesosphere from CO microwave spectra

Microwave spectra of CO in the Venus mesosphere were measured and analyzed in order to provide mixing profiles. The results indicate that there is a significant dependence of the observed spectra on the phase of Venus. This dependence is tied to a diurnal variation in the vertical profile of CO mixing ratios with the local solar zenith angle. Spectra of the nightside hemisphere are characterized by very little absorption in the wings of the spectra, yet very deep absorption in the line center. Dayside spectra exhibit considerably greater absorption in the line wings and less absorption in the line center. Solutions for the CO mixing profile derived from spectra show that the nightside atmosphere contains two to four times the CO abundance above about 95 km relative to the dayside atmosphere above 95 km. Conversely, the dayside atmosphere between 80 and 90 km shows two to four times the CO abundance for the same altitude region in the nightside atmosphere.

Clancy, R. T.↗

Signal Isolators

The City of Dubuque, Iowa's new Water Division computer system was experiencing failures of the analog inputs ranging from signals out of tolerance by more than 30 percent to intermittent and sometimes complete loss of signals. The problem stemmed from a lack of signal isolation of the analog input cards, which made the inputs vulnerable to interference from storms and machinery. Electronic technician Bob Ervolino read an article in Tech Briefs describing an Ames Research Center solution to a similar problem. He studied the Technical Support Package and contacted the vendor; the information saved the Water Division more than 50 percent of the cost of commercial isolators.

Source record↗

Resource Adequacy in Decarbonizing Power Systems

Decarbonization of the power sector is instrumental to reducing emissions worldwide. Following the 13th Clean Energy Ministerial conference (CEM13) in 2022, several governments signaled their intention to develop power sector decarbonization action plans. The 21st Century Power Partnership (21CPP), in coordination with all Clean Energy Ministerial power workstreams and collaborators, is providing technical support on critical focus areas as these countries prepare their action plans. Countries will present the action plans at the upcoming CEM14 in India. Brought to you by the Clean Energy Solutions Center and 21CPP, this webinar will focus on resource adequacy and grid flexibility, key themes in the CEM14 action plans and critical topics for integrating variable renewable energy into the grid while ensuring system reliability. Global energy experts will discuss how grid planners can ensure stable supply while rapidly decarbonizing the power system and how various policies can increase the power grid's flexibility.

emissions↗

Internet Protocol Display Sharing Solution for Mission Control Center Video System

With the advent of broadcast television as a constant source of information throughout the NASA manned space flight Mission Control Center (MCC) at the Johnson Space Center (JSC), the current Video Transport System (VTS) characteristics provides the ability to visually enhance real-time applications as a broadcast channel that decision making flight controllers come to rely on, but can be difficult to maintain and costly. The Operations Technology Facility (OTF) of the Mission Operations Facility Division (MOFD) has been tasked to provide insight to new innovative technological solutions for the MCC environment focusing on alternative architectures for a VTS. New technology will be provided to enable sharing of all imagery from one specific computer display, better known as Display Sharing (DS), to other computer displays and display systems such as; large projector systems, flight control rooms, and back supporting rooms throughout the facilities and other offsite centers using IP networks. It has been stated that Internet Protocol (IP) applications are easily readied to substitute for the current visual architecture, but quality and speed may need to be forfeited for reducing cost and maintainability. Although the IP infrastructure can support many technologies, the simple task of sharing ones computer display can be rather clumsy and difficult to configure and manage to the many operators and products. The DS process shall invest in collectively automating the sharing of images while focusing on such characteristics as; managing bandwidth, encrypting security measures, synchronizing disconnections from loss of signal / loss of acquisitions, performance latency, and provide functions like, scalability, multi-sharing, ease of initial integration / sustained configuration, integration with video adjustments packages, collaborative tools, host / recipient controllability, and the utmost paramount priority, an enterprise solution that provides ownership to the whole process, while maintaining the integrity of the latest technological displayed image devices. This study will provide insights to the many possibilities that can be filtered down to a harmoniously responsive product that can be used in today's MCC environment.

Brown, Michael A.↗

Solution of multi-center molecular integrals of Slater-type orbitals

The troublesome multi-center molecular integrals of Slater-type orbitals (STO) in molecular physics calculations can be evaluated by using the Fourier transform and proper coupling of the two center exchange integrals. A numerical integration procedure is then readily rendered to the final expression in which the integrand consists of well known special functions of arguments containing the geometrical arrangement of the nuclear centers and the exponents of the atomic orbitals. A practical procedure was devised for the calculation of a general multi-center molecular integrals coupling arbitrary Slater-type orbitals. Symmetry relations and asymptotic conditions are discussed. Explicit expressions of three-center one-electron nuclear-attraction integrals and four-center two-electron repulsion integrals for STO of principal quantum number n=2 are listed. A few numerical results are given for the purpose of comparison.

Tai, H.↗

Numerical studies of the margin of vortices with decaying cores

The merging of vortices to a single one is a canonical incompressible viscous flow problem. The merging process begins when the core sizes or the vortices are comparable to their distances and ends when the contour lines of constant vorticity lines are circularized around one center. Approximate solutions to this problem are constructed by adapting the asymptotic solutions for distinct vortices. For the early stage of merging, the next-order terms in the asymptotic solutions are added to the leading term. For the later stage of merging, the vorticity distribution is reinitialized by vortices with overlapping core structures guided by the 'rule of merging' and the velocity of the 'vortex centers' are then defined by a minimum principle. To show the accuracy of the approximate solution, it is compared with the finite-difference solution.

Liu, G. C.↗